• Title/Summary/Keyword: RF 차폐

Search Result 41, Processing Time 0.024 seconds

Actively-Shielded Brain-Only $R^{2}$-Gradient Coil for Localized MRI/MRS (Localized MRI/MRS를 위한 차폐된 두뇌촬영용 $R^{2}$-경사자계코일)

  • Oh, C.H.;Yang, Y.J.;Kim, S.K.;Yi, Y.;Lee, H.K.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.161-164
    • /
    • 1996
  • An actively-shielded $r^{2}$-gradient coil has been developed for brain localized MRI or MRS. Spatial localization is very useful for spatial volume selection in MRI or MR Spectroscopy(MRS). The radial(or $R^{2}-$) gradient coil is useful in reducing the artifact or in improving the SNR by selecting the volume with less number of RF pulses. It is, however, difficult to implement the coil with a gradient intensity strong enough to use it for practical whole-body MRI system. For example, the smallest volume size for selection is just 6 cm in diameter with a 250 Ampere of current driving for a whole-body system (in case of 70-cm-diameter). In this study, an asymetric $r^{2}$-coil with a small diameter of 35 cm has been designed and implemented for brain localized MRI or MRS. An 8-rod high-pass-type birdcage RF coil has also been implemented. The coil set has been developed for 1.0 Tesla Medison MRI system and its performance has been verified experimentally.

  • PDF

Transparent electrode performance of $TiO_2$/ZnS/Ag/ZnS/$TiO_2$ multi-layer for PDP filter ($TiO_2$/ZnS/Ag/ZnS/$TiO_2$ 다층막의 PDP 필터용 전극 특성)

  • Oh, Won-Seok;Lee, Seo-Hee;Jang, Gun-Eik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.217-217
    • /
    • 2010
  • 산화물유전체/금속/산화물유전체(D/M/D) 구조의 투명전극은 우수한 통전성과 투광성을 갖는 동시에 근적외선 및 전자파 차폐가 가능하여 각종 디스플레이 장치로의 응용을 위해 많은 연구가 진행 중이다. 이러한 구조의 다층막의 경우 금속층과 산화물층간 계면에서의 산소확산으로 인한 광학적, 전기적 특성 저하가 문제가 되고 있다. 본 연구에서는 층간 산소확산방지를 통해 다층막의 전기적 특성을 개선하기 위해 $TiO_2$/Ag/$TiO_2$, $TiO_2$/ZnS/Ag/ZnS/$TiO_2$ 구조의 다층막을 DC/RF 마그네트론 스퍼터를 이용하여 제조하여 ZnS 박막이 다층막의 특성에 미치는 영향을 비교 평가하였다. 제조된 박막의 전기적, 광학적, 계면 특성을 4-point probe, Spctrophotometer, AES을 이용하여 분석하였으며 PDP필터용 전극으로의 적용 가능성을 평가하였다.

  • PDF

Preparation of Electromagnetic Wave Shielding Fabrics by Electroless Plating (무전해 도금법에 의한 전자파 차단 의류소재의 제조)

  • Kim Su Mi;Song Wha Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.1 s.139
    • /
    • pp.149-156
    • /
    • 2005
  • The purpose of this study was to produce the high quality of electromagnetic wave shielding fabrics. In this study, we have produced polyester fabrics by electroless Ag plating. The untreated polyester was etched with $4\%$ NaOH solution added accelerant(Benzyl Dimethyl Dodecyl Ammonium Chloride) then it was catalyzed by $SnCl_2$ solution and activated by $PdCl_2$ solution. Electroless Ag plating was carried out by changing conditions such as temperature. time, weight loss rate of polyester and kind of reducing agents. The electromagnetic wave shielding effectiveness of polyester fabric by electroless Ag plating was measured by RF Impedance Analyzer and element of electromagnetic wave shielding substance was measured using Electron probe micro analyzer. The results were as follows; The plating bath using potassium sodium tartrate by reducing agent was excellent electromagnetic wave shielding effectiveness. Element of electromagnetic wave shielding substance was silver. Electromagnetic wave shielding effectiveness was shown over 64dB at the temperature of $40^{\circ}C$, treating time 30min., weight loss rate $20\%$.

Simultaneous Realization of Electromagnetic Shielding and Antibacterial Effect of Al Doped ZnO Thin Films onto Glass Substrate (유리 기판 위에 증착된 Al Doped ZnO 박막을 이용한 전자파 차폐 및 항균 특성의 동시 구현)

  • Choi, Hyung-Jin;Yoon, Soon-Gil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.279-283
    • /
    • 2016
  • In this study, we intended to achieve both antibacterial properties and electromagnetic shielding using the Al-doped ZnO (AZO) films. FTS (Facial Target Sputtering) magnetron sputtering was used for the AZO thin films instead of the conventional RF sputtering because the FTS sputtering could avoid the damage for the plasma as well as fabrication of thin films with a high quality. The 300-nm thick AZO thin films grown on glass substrate showed a resistivity of about $7{\times}10^{-4}{\Omega}-cm$ and a transmittance of about 90% at a wavelength of 550 nm. AZO thin films were investigated for the electromagnetic shielding effectiveness measured by 2-port network method at 1.5 ~ 3 GHz. The AZO (300 nm)/glass films showed an EMI shielding effectiveness of approximately 27 dB. An antibacterial effect was measured by the film attachment method (JIS Z 2801). The percent reductions of bacteria by AZO films were 99.99668% and 99.99999% against Staphylococcus aureus and Escherichia coli, respectively.

High-frequency Magnetic Properties of Ni-Zn-Co Ferrites Used for Mangetic Shielding in NFC (NFC의 자기 차폐용 Ni-Zn-Co 페라이트 자성체의 고주파 자기특성)

  • Ryu, Yo-Han;Kim, Sung-Soo
    • Journal of Powder Materials
    • /
    • v.21 no.6
    • /
    • pp.429-433
    • /
    • 2014
  • This study investigated the magnetic properties and frequency dispersion of complex permeability of Ni-Zn-Co ferrites used for magnetic shielding in near field communication (NFC) system. The sintered specimens of $(Ni_{0.7}Zn_{0.3})_{1-x}Co_xFe_2O_4$ composition were prepared by the conventional ceramic processing. The coercive force and saturation magnetization were measured by vibrating sample magnetometer. The complex permeability was measured by RF impedance analyzer in the range of 1 MHz~1.8 GHz. The coercive force increased and saturation magnetization decreased with increasing the Co substitution. The real and imaginary parts of complex permeability decreased and the resonance frequency increased with Co substitution, which was attributed to the increase in crystal anisotropy field and reduction in saturation magnetization. The effect of Co substitution could be found in reducing the magnetic loss to nearly zero at the operating frequency of NFC (13.56 MHz).

Influence of Sintering Temperature on Magnetic Properties of Ni-Zn-Cu Ferrites Used for Mangetic Shielding in NFC (NFC의 자기차폐용 Ni-Zn-Cu 페라이트의 자기특성에 미치는 소결온도의 영향)

  • Ryu, Yo-Han;Kim, Sung-Soo
    • Journal of Powder Materials
    • /
    • v.23 no.2
    • /
    • pp.132-135
    • /
    • 2016
  • This study investigates the influence of sintering temperature on the magnetic properties and frequency dispersion of the complex permeability of Ni-Zn-Cu ferrites used for magnetic shielding in near-field communication (NFC) systems. Sintered specimens of $(Ni_{0.7}Zn_{0.3})_{0.96}Cu_{0.04}Fe_2O_4$ are prepared by conventional ceramic processing. The complex permeability is measured by an RF impedance analyzer in the range of 1 MHz to 1.8 GHz. The real and imaginary parts of the complex permeability depend sensitively on the sintering temperature, which is closely related to the microstructure, including grain size and pore distribution. In particular, internal pores within grains produced by rapid grain growth decrease the permeability and increase the magnetic loss at the operating frequency of NFC (13.56 MHz). At the optimized sintering temperature ($1225-1250^{\circ}C$), the highest permeability and lowest magnetic loss can be obtained.

Patient Setup Aid with Wireless CCTV System in Radiation Therapy (무선 CCTV 시스템을 이용한 환자 고정 보조기술의 개발)

  • Park, Yang-Kyun;Ha, Sung-Whan;Ye, Sung-Joon;Cho, Woong;Park, Jong-Min;Park, Suk-Won;Huh, Soon-Nyung
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.300-308
    • /
    • 2006
  • $\underline{Purpose}$: To develop a wireless CCTV system in semi-beam's eye view (BEV) to monitor daily patient setup in radiation therapy. $\underline{Materials\;and\;Methods}$: In order to get patient images in semi-BEV, CCTV cameras are installed in a custom-made acrylic applicator below the treatment head of a linear accelerator. The images from the cameras are transmitted via radio frequency signal (${\sim}2.4\;GHz$ and 10 mW RF output). An expected problem with this system is radio frequency interference, which is solved utilizing RF shielding with Cu foils and median filtering software. The images are analyzed by our custom-made software. In the software, three anatomical landmarks in the patient surface are indicated by a user, then automatically the 3 dimensional structures are obtained and registered by utilizing a localization procedure consisting mainly of stereo matching algorithm and Gauss-Newton optimization. This algorithm is applied to phantom images to investigate the setup accuracy. Respiratory gating system is also researched with real-time image processing. A line-laser marker projected on a patient's surface is extracted by binary image processing and the breath pattern is calculated and displayed in real-time. $\underline{Results}$: More than 80% of the camera noises from the linear accelerator are eliminated by wrapping the camera with copper foils. The accuracy of the localization procedure is found to be on the order of $1.5{\pm}0.7\;mm$ with a point phantom and sub-millimeters and degrees with a custom-made head/neck phantom. With line-laser marker, real-time respiratory monitoring is possible in the delay time of ${\sim}0.17\;sec$. $\underline{Conclusion}$: The wireless CCTV camera system is the novel tool which can monitor daily patient setups. The feasibility of respiratory gating system with the wireless CCTV is hopeful.

Research of Communication Coverage and Terrain Masking for Path Planning (경로생성 및 지형차폐를 고려한 통신영역 생성 방법)

  • Woo, Sang Hyo;Kim, Jae Min;Beak, InHye;Kim, Ki Bum
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.407-416
    • /
    • 2020
  • Recent complex battle field demands Network Centric Warfare(NCW) ability to control various parts into a cohesive unit. In path planning filed, the NCW ability increases complexity of path planning algorithm, and it has to consider a communication coverage map as well as traditional parameters such as minimum radar exposure and survivability. In this paper, pros and cons of various propagation models are summarized, and we suggest a coverage map generation method using a Longley-Rice propagation model. Previous coverage map based on line of sight has significant discontinuities that limits selection of path planning algorithms such as Dijkstra and fast marching only. If there is method to remove discontinuities in the coverage map, optimization based path planning algorithms such as trajectory optimization and Particle Swarm Optimization(PSO) can also be used. In this paper, the Longley-Rice propagation model is used to calculate continuous RF strengths, and convert the strength data using smoothed leaky BER for the coverage map. In addition, we also suggest other types of rough coverage map generation using a lookup table method with simple inputs such as terrain type and antenna heights only. The implemented communication coverage map can be used various path planning algorithms, especially in the optimization based algorithms.

Recent Status of Commercial PET Cyclotron and KOTRON-13 (KOTRON-13과 상용 PET 사이클로트론의 최근 기술 동향)

  • Chai, Jong-Seo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This paper is described on the development of KOTRON-13 and recent status of PET cyclotron by commercial cyclotron companies. KIRAMS has developed medical cyclotron which is KIRAMS-13. Samyoung Unitech produces KOTRON-13 with transfered technology by KIRAMS. As a part of Regional Cyclotron Installation Protect, KOTRON-13 cyclotrons and $[18F]FDG$ production modules are being installed at regional cyclotron centers in Korea. The medical concern with radiation technology has been growing for the last several years. Early cancer diagnosis through the cyclotron and PET-CT have been brought to public attention by commercial cyclotron models in the world. The new commercial cyclotron models are introduced compact low energy cyclotrons developed by CTI, GE, Sumitomo in recent. It produces different short-lived radioisotopes, such as $[^{18}F],\;[^{11}C],\;[^{13}N]\;and\;[^{15}O]$. For the better reliability acceleration particle is proton only. The characteristics of new model cyclotrons are changed to lower energy corresponding to less 13 MeV. New models have self-shielding and low power consumption. Design criteria for the different types of commercial cyclotrons are described with reference to hospital demands.

Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF