• Title/Summary/Keyword: RF 차폐

Search Result 41, Processing Time 0.039 seconds

Effects of Sputtering pressure on preferred Orientation of Shielding NbTi Thin Film by RF Magnetron Sputtering (RF 마그네트론 스퍼터링법으로 제조된 차폐용 NbTi박막의 우선방향에 미치는 스퍼터링 압력의 영향)

  • Kim, Bong-Seo;Woo, Byung-Chul;Byun, Woo-Bong;Lee, Hee-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1098-1101
    • /
    • 1995
  • NbTi thin films were prepared on Si wafer and Cu substrate by rf magnetron sputtering in the range of sputtering pressure $3{\times}10^{-2}$torr to $3{\times}10^{-4}$torr at room temperature. The influence of sputtering pressure and substrate type on crystallographic orientation and morphology of NbTi thin films was investigated by using X-ray diffraction(XRD) and scanning electron microscopy(SEM), respectively. And the effect of crystallographic orientation and morphology of NbTi film on electromagnetic behaviors was estimated by measuring critical current in various applied magnetic field. The film morphology changed from porous structure consisting of tapered crystallites to densely deposited film decreasing with sputtering pressure. The change of crystallographic orientation with the sputtering pressure and rf power was calculated from the texture coefficient of(002) plane based on XRD patterns. It was found that a change of texture coefficient of(002) plane increased with decreasing sputtering pressure. From observation of critical current in various applied magnetic field, we have identified that the change of critical current abruptly decrease applying with magnetic field and NbTi film produced at high sputtering pressure does not exhibit superconductivity but at low sputtering pressure shows superconductivity.

  • PDF

A Channel Estimation Method for Multipath Feedback Interference Signal Cancellation of RF Repeaters (RF 중계기의 다중 궤환 간섭 신호 제거를 위한 채널 추정 방식)

  • Lee, Sang-Dae;Park, Jin;Sung, Won-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2A
    • /
    • pp.98-106
    • /
    • 2008
  • To reduce the outage probability and to increase the transmission capacity, the importance of repeaters in cellular systems keeps increasing. Unlike optical repeaters which require wireline connections, RF repeaters are easy to install, have low limitations in location and also have a reduced operational expense such as the optical fiber maintenance cost. On the other hand, RF repeaters suffer the interference due to the feedback signals between the transmitter and receiver antennas, hence require an extra interference cancellation method when the amount of the feedback signal reduction by using the shielding is not sufficient. In this paper, a channel estimation method for two-path feedback interference signals in the ICS (Interference Cancellation System) repeaters using baseband signal processing is proposed and its performance is evaluated. When compared with the conventional method which estimates each multipath individually, the proposed method achieves 10 dB performance gain in terms of the normalized mean-squared-error.

Transmission Line Characteristics of Silicon Based Interconnections with Patterned Ground Shields and its Implication for RF/Microwave ICs (실리콘 공정에서 패턴으로 삭각된 접지(PGS)를 이용한 인터컨넥션의 전송선 특성분석 및 RF/초고주파 집적회로에의 응용)

  • Gwak, Huk-Yong;Lee, Sang-Gug;Cho, Yun-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.6
    • /
    • pp.50-56
    • /
    • 2000
  • The integrated circuit interconnection lines are experimented with patterned ground shields (PGS) at microwave frequencies. Measurement results demonstrate that the PGS can significantly reduce the power loss through the interconnect lines over wide frequency ranges as the PGS shields the lossy silicon substrate. The transmission line characteristics of the PGS interconnect lines are analyzed and identified that the PGS reduces the wave length of the interconnect line.

  • PDF

우수한 광 투과도 지닌 적외선 차폐 단열창호를 위한 상온 ITO 필름에 관한 연구

  • Lee, Dong Hoon;Park, Eun Mi;Suh, Moon Suhk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.342.2-342.2
    • /
    • 2014
  • IZO, ITO, ITO 등의 투명전극들 중 Indium Tin Oxide (ITO) 다른 전극에 비해 높은 광투과도와 낮은 저항으로 인하여 다양한 부분에서 널리 이용되고 있다. 본 연구에서는 우수한 투과도의 멀티 layer 단열 창호를 위한 film 개발을 위해 RF magnetron system을 이용하여 Sodalime Glass와 polyethylene terephthalate (PET) substrate에 ITO를 증착함으로써 전기적 광학적 특성을 조사하였다. 실험은 power 변화와 Ar, O2의 가스 분압비, Working Pressure의 변화를 변수로 두어 진행하였다. 측정은 Ellipsometry를 이용하여 광학적인 두께와 굴절률을 조사하였고 UV visible spectrometer를 통해 광학적인 투과도를 확인하였다. Power는 100 Watt 늘려가며 진행하였고 O2 유량의 변화에 따라 투과도와 면저항, 굴절률 특성이 달라짐을 확인할 수 있었다. O2의 유량에 따라 면저항이 줄어들다가 어느 정도 이상이 되면 급격히 증가함을 확인할 수 있었다. Working Pressure 변화에 따른 전기적 광학적 특성 또한 확인 하였다.

  • PDF

A Study for Shopping Customer's Location Tracking and Moving Line Analysis Using Reference Tag on based RFID (RFID기반의 Reference Tag를 이용한 쇼핑 고객 위치추적 및 동선분석에 관한 연구)

  • Lim, Sang-Min;Lee, Keun-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.151-157
    • /
    • 2009
  • This project would discuss how to improve the limit and enhance the accuracy and confidence and the improved algorithm path searching engine module shelter's interference limit on spot searching and analysing by using real time path finding technology and USB memo교 RF which is fused to a Tag(u-Card).

Test-bed Design for the Evaluation of Wireless Communication System on Small Launch Vehicle (소형 발사체 무선 통신시스템 검증을 위한 테스트 베드 설계)

  • Lee, Dae-Hyun;Oh, TaeckKeun;Park, Dong-Hwa;Lee, Hong-Ki;Park, Dong-Hyun;Song, Ho-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.311-318
    • /
    • 2018
  • In this paper, test-bed for the evaluation of wireless communication system on a small launch vehicle is proposed. The proposed test-bed consists of antenna test-coupler, RF attenuators, and RF switch modules. The antenna test-coupler isolates antennas for each band and transmits / receives wireless signals. The RF attenuator and switch are used for path selection of testing signal path. In design and measurement result of the antenna test-coupler, the antenna test-coupler has shielding effect higher than 39.3, 47.1, 56.1 dB at UHF-, S-, X-band. Through testing on small launch vehicle wireless communication system, we were able to successfully transmit and receive data between each test system and launch vehicle with antenna path switching.

Fabrication and Characteristics of Epoxy Resin-Type Based Neutron Shielding Materials (에폭시수지계 중성자 차폐재 제조 및 특성)

  • Cho, Soo-Haeng;Kim, Ik-Soo;Do, Jae-Bum;Ro, Seung-Gy;Park, Hyun-Soo
    • Korean Journal of Materials Research
    • /
    • v.8 no.5
    • /
    • pp.457-463
    • /
    • 1998
  • New neutron shielding materials, KNS-201, KNS-301 and KNS-601 have been fabricated to be used for radioactive material shipping and storage cask. The base materials are a modified and a hydrogenated bisphenol- A type and novolac type epoxy resin, and aluminium hydroxide and boron carbide are added. These shielding materials offer good fluidity at processing, which makes it possible to form this resin shield into complicated geometric shapes such as radioactive material shipping and storage cask. Several measurements were made for the shielding materials to evaluate the thermal and mechanical properties and radiation resistance. The properties of the shielding materials are as follows: onset temperatures 2S7~28$0^{\circ}C$, thermal conductivities 0.9S~1.14W/m. K, thermal expansion coefficients 0.77~1.26x$10_{-6}{\circ}C_{-1}$, combustion characteristics < 80$0^{\circ}C$, ATB(average time of burning) < 5sec, AEB(average extent of burning) < 5mm, tensile strengths 2.5~3.2kg/$\textrm{mm}^2$, compressive strengths 13.2~1S.2kg/$\textrm{mm}^2$, flexural strengths 5.2 -6.4kg/$\textrm{mm}^2$. In general, the concerned properties of KNS-201, KNS-301 and KNS-601 were revealed to be better than those of NS-4- FR. foreign neutron shielding material. It is also observed that the radiation resistance of KNS- 601 was better than those of KNS-201 and KNS-301.

  • PDF

CMP Properties of ITO with the deposition temperature (기판온도에 따른 ITO박막의 CMP특성)

  • Choi, Gwon-Woo;Lee, Young-Kyun;Lee, Woo-Sun;Jun, Young-Kil;Ko, Pil-Ju;Seo, Yong-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.165-165
    • /
    • 2007
  • 투명전도박막은 ITO, $SnO_2$, ZnO, 등이 있으나 $SnO_2$는 자외선 영역까지 투과시키는 우수한 광학적 특성을 나타내지만, 상당히 큰 전기저항으로 인해 현재는 현재 ITO가 널리 이용되고 있다. ITO(Indium Tin Oxide)박막은 자외선 영역에서 반사율이 높으며 가시광선영역에서는 80%이상의 뛰어난 투과율을 가지고 있다. 또한 낮은 전기저항과 넓은 광학적 밴드갭 때문에 가장 유용한 투과전도성 재료 중에 하나이다. 이러한 특성 때문에 여러 가지 문자 표시소자의 투명전극, 태양전지의 창재료, 정전차폐를 위한 반도체 포장재료, 열반사막, 면발열체, 광전변환 소자에 응용되고 있다. 일반적으로 박막의 제작에는 저항가열법과 전자선가열법, 스퍼터링법의 물리적 증착과 화학적 증착으로 나뉜다. 본 논문에서는 증착온도를 달리 하여 RF-sputtering에 의해 ITO박막을 증착한 후 온도증가에 따른 박막의 특성을 연구하였으며 또한 광역평탄화를 위한 CMP공정을 적용하여 증착온도가 연마에 미치는 영향을 연구하였다. 본 실험에서 사용된 ITO박막은 $2{\times}2Cm$의 Corning glass위에 증착되었으며 타겟은 $In_2O_3$$SnO_2$가 9:1로 혼합된 Purity 99.99%이상의 직경 2 inch인 ITO타겟을 사용하였다. 박막 증착시 기판온도는 상온에M $200^{\circ}C$까지 변화시켰으며 RF power는 100W로 일정하게 하였으며 증착압력은 $8{\times}10^{-2}$Torr이였다. CMP공정조건은 헤드속도 60rpm, 플레이튼 속도 60rpm, 슬러리 주입 유량 60mml/min, 압력 $300g/cm^2$이였다. 전기적 특성은 four point probe를 이용하여 측정하였으며 광학적 특성은 UV-Visible Spectrometer를 이용하여 200~900nm의 파장범위에서 광투과도를 측정하였다.

  • PDF

Development of 1.0 Tesla Compact MRI System (1.0 Tesla 자기 공명 진단 장치의 개발)

  • Lee, H.K.;Oh, C.H.;Ahn, C.B.;Chang, Y.H.;Shin, D.W.;Lee, K.N.;Jang, K.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

Electromagnetic Field Characteristics of the Slotted Coaxial Clables (동축 슬롯케이블의 전자파 특성)

  • 이애경;김두경;김정기
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.4
    • /
    • pp.17-25
    • /
    • 1991
  • Slotted coaxial cables are used for a wide variety of radio communications and control applications within buildings, subways, tunnels and outdoors. They function as continuous antennas to solve RF coverage problems in difficult or confined areas. In this paper the electric and magnetic field distributions inside and outside of axially slotted coaxial cables are analyzed numerically. This paper gets the fields from the equivalent potentials which are obtained by grid relaxation method. The slot electric field configurations are consistent with Essam E. Hassan's results. The field distributions in the slotted coaxial cables show that the TEM mode doesn't propagate any longer in them. But the fields don't variate with the frequencies that are under the first higher order mode cutoff frequency of shielded coaxial cable of the same dimension The fields inside of the tunnel ($3\times4$) including the slotted coaxial cable axially are similar to those of $TE_{10}$ mode at 38.75 MHz. This method offers the basis for theoretical analysis of coaxial cables with nonuniform slots as well as coaxial cables in tunnels and buildings.

  • PDF