• 제목/요약/키워드: RC moment-resisting frame

검색결과 56건 처리시간 0.028초

Experimental and numerical investigation on RC moment-Resisting frames retrofitted with NSD yielding dampers

  • Esfandiari, J.;Zangeneh, E.;Esfandiari, S.
    • Advances in concrete construction
    • /
    • 제13권4호
    • /
    • pp.339-347
    • /
    • 2022
  • Retrofitting in reinforced concrete structures has been one of the most important research topics in recent years. There are several methods for retrofitting RC moment-resisting frames. the most important of which is the use of steel bracing systems with yielding dampers. With a proper design of yielding dampers, the stiffness of RC frame systems can be increased to the required extent so that the ductility of the structure is not significantly reduced. In the present study, two experimental samples of a one-third scale RC moment-resisting frame were loaded in the laboratory. In these experiments, the retrofitting effect of RC frames was investigated using Non-uniform Slit Dampers (NSDs). Based on the experimental results of the samples, seismic parameters, i.e., stiffness, ductility, ultimate strength, strength reduction coefficient, and energy dissipation capacity, were compared. The results demonstrated that the retrofitted frame had very significant growth in terms of stiffness, ultimate strength, and energy dissipation capacity. Although the strength reduction factor and ductility decreased in the retrofitted sample. In general, the behavior of the frame with NSDs was evaluated better than the bare frame.

Seismic performance of low and medium-rise RC buildings with wide-beam and ribbed-slab

  • Turker, Kaan;Gungor, Ilhan
    • Earthquakes and Structures
    • /
    • 제15권4호
    • /
    • pp.383-393
    • /
    • 2018
  • In this study, seismic performance of low and medium-rise RC buildings with wide-beam and ribbed-slab were evaluated numerically. Moment resisting systems consisting of moment and dual frame were selected as structural system of the buildings. Sufficiency of moment resisting wide-beam frames designed with high ductility requirements were evaluated. Upon necessity frames were stiffen with shear-walls. The buildings were designed in accordance with the Turkish Earthquake Code (TEC 2007) and were evaluated by using the strain-based nonlinear static method specified in TEC. Second order (P-delta) effects on the lateral load capacity of the buildings were also assessed in the study. The results indicated that the predicted seismic performances were achieved for the low-rise (4-story) building with the high ductility requirements. However, the moment resisting frame with high ductility was not adequate for the medium-rise building. Addition of sufficient amount of shear-walls to the system proved to be efficient way of providing the target performance of structure.

5층 철근콘크리트 모멘트-저항골조 구조물의 내진성능 평가 및 공사원가 분석 (Seismic Performance Evaluation and Economic Analysis of 5-Story RC Moment-Resisting Frames)

  • 강석봉;김성대;박의수;오상묵;손기영
    • 한국건축시공학회지
    • /
    • 제15권6호
    • /
    • pp.569-577
    • /
    • 2015
  • 구조물 내진설계에 대한 개념이 사양중심설계에서 성능기반설계로 변화하고 있다. 구조물 목표성능을 직접 부여하여 설계하는 성능기반설계를 위해서는 구조물 실제 거동을 정확히 예측하기 위한 비탄성 구조해석이 필요하다. 이에 본 연구에서는 KBC2009 기준으로 설계한 5층 철근콘크리트 모멘트-저항골조 시스템 구조물을 대상으로 푸쉬오버해석을 수행하여 내진성능을 평가한 후 직접공사비를 산출하여 경제성을 분석하였다. 분석 결과 보통 및 중간모멘트골조는 요구성능설계기준을 만족하며 직접공사비 또한 유사한 것으로 평가되었다. 하지만, 강 기둥-약 보 기준이 적용되는 특수모멘트골조는 요구성능설계기준을 만족하나 다른 골조시스템 보다 비경제적인 것으로 평가되었다. 따라서 IBC2012에서는 내진설계범주 D 중간모멘트골조 적용을 제한하고 있지만 5층 철근콘크리트 모멘트-저항골조 구조물의 경우, 특수모멘트골조 보다 보통 및 중간모멘트골조로 설계하는 것이 합리적이라고 판단된다.

비내력벽을 가진 RC모멘트저항골조의 취약도 해석 (Fragility Analysis of RC Moment Resisting Frame with Masonry Infill Walls)

  • 고현;박용구;이동근
    • 한국전산구조공학회논문집
    • /
    • 제22권4호
    • /
    • pp.355-362
    • /
    • 2009
  • 국내에 많이 건설되고 있는 빌라형 주택은 건축적인 요구를 위하여 저층부에 필로티를 두고 있는 경우가 많다. 구조물 상층부의 비내력벽에 의하여 저층에 연약층을 유발하고 따라서 지진에 매우 취약하다. 그러나 설계시 일반적인 설계방법과 동일하게 상부층의 칸막이벽은 비구조체로 간주되어 무시된다. 그러므로 설계단계에서 무시되는 비내력벽의 유무에 따라서 건축물이 어떠한 지진거동의 차이점을 보이는지 살펴볼 필요가 있다. 본 연구에서는 대상 건축물의 지진취약도 해석을 통하여 비내력벽의 유무에 따른 건축물의 지진거동을 평가하였다. 비내력벽의 유무에 따른 동일한 골조를 가지는 저층 철근콘크리트 건축물을 적용하여 지진거동에서 비내력벽의 영향을 평가하였다. 비내력벽은 보편화된 모형화 방법인 등가의 대각 압축 스트럿으로 고려하였다. 골조만 있는 모델과 연약층이 있는 모델의 취약도곡선을 비교하였다. 해석 결과로 연약층이 있는 RC 건물의 내진성능은 설계기준에서 제시하고 있는 성능수준을 만족하지 못하며 지진에 취약함을 보여준다.

내진특수상세를 적용한 RC 이중골조 건물의 설계 (Design of RC dual system building using special seismic detail)

  • 이한선;고동우;선성민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.190-193
    • /
    • 2006
  • The definition of the Dual system is that the total seismic force resistance is to be provided by the combination of the moment frame and the shear walls or braced frames in proportion to their stiffness and the moment frame shall be capable of resisting at least 25% of the design force in Korean Building Code 2005 (KBC 2005). But, the definition of moment frame is ambiguous whether the moment frame include the imaginary columns in the shear wall (Case I) or include only the columns outside the shear wall (Case II). 60-story RC building was designed as dual system for Case I and Case II, and the required strength and reinforcement are compared. Moment and axial capacity of the shear wall of Case II decreased about 5% due to the absence of the column in the shear wall. The requirement of upper and bottom reinforcement of slab in Case II increased 13% and 40%, respectively, when compared to those of Case I. The required longitudinal reinforcement in columns for Case II is about 1.5 times larger than that of Case I.

  • PDF

Seismic behavior of steel frames with replaceable reinforced concrete wall panels

  • Wu, Hanheng;Zhou, Tianhua;Liao, Fangfang;Lv, Jing
    • Steel and Composite Structures
    • /
    • 제22권5호
    • /
    • pp.1055-1071
    • /
    • 2016
  • The paper presents an innovative steel moment frame with the replaceable reinforced concrete wall panel (SRW) structural system, in which the replaceable concrete wall can play a role to increase the overall lateral stiffness of the frame system. Two full scale specimens composed of the steel frames and the replaceable reinforced concrete wall panels were tested under the cyclic horizontal load. The failure mode, load-displacement response, deformability, and the energy dissipation capacity of SRW specimens were investigated. Test results show that the two-stage failure mode is characterized by the sequential failure process of the replaceable RC wall panel and the steel moment frame. It can be found that the replaceable RC wall panels damage at the lateral drift ratio greater than 0.5%. After the replacement of a new RC wall panel, the new specimen maintained the similar capacity of resisting lateral load as the previous one. The decrease of the bearing capacity was presented between the two stages because of the connection failure on the top of the replaceable RC wall panel. With the increase of the lateral drift, the percentage of the lateral force and the overturning moment resisted by the wall panel decreased for the reason of the reduction of its lateral stiffness. After the failure of the wall panel, the steel moment frame shared almost all the lateral force and the overturning moment.

철근 콘크리트 특수 모멘트 골조 건물의 비탄성 동적 요구값 (Inelastic Dynamic Demands of a RC Special Moment Frame Building)

  • 김태완
    • 한국지진공학회논문집
    • /
    • 제9권5호
    • /
    • pp.11-19
    • /
    • 2005
  • 건축 구조물의 내진 설계는 탄성 정적 방법에 기초하고 있으나, 강진시 구조물의 실제 거동은 비탄성 동적이기 때문에 설계 규준의 적합성을 판단하기 위해서는 비탄성 동적 해석이 요구된다. 본 논문에서는 철근 콘크리트 특수 모멘트 저항 골조 건물을 선택하여 IBC 2003에 따라 설계한 후, 선택된 부재들의 최대 소성 회전, 소산 에너지를 구하여, 건물의 비탄성 거동이 규준에서 의도한 거동을 보이는 지를 검토함과 동시에 층간변위률 요구값을 구하여 설계 한도를 만족하는 지를 조사하였다. 더불어 비횡력 저항 시스템인 내부 모멘트 저항 골조의 해석시 포함 여부의 영향도 함께 조사하였다. 해석 결과 IBC 2003에 의해 설계된 건물은 규준이 의도한 비탄성 거동을 보여주었으며 층간변위률 또한 설계한도를 만족하였다. 그리고, 내부 모멘트 저항 골조는 지진 해석 결과에 중요한 영향을 미치므로 해석 모델에 반드시 포함되어야 함을 알수 있었다.

Optimum distribution of steel frame assembly for seismic retrofit of framed structures

  • Michael Adane;Seungho Chun;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • 제50권3호
    • /
    • pp.337-345
    • /
    • 2024
  • This research proposed a particle swarm optimization (PSO) based seismic retrofit design of moment frame structures using a steel frame assembly. Two full scale specimens of the steel frame assembly with different corner details were attached to one-story RC frames for seismic retrofit, and the lateral load resisting capacities of the retrofitted frames subjected to cyclic loads were compared with those of a bare RC frame. The open source software framework Opensees was used to develop an analytical model for validating the experimental results. The developed analytical model and the optimization scheme were applied to a case study structure for economic seismic retrofit design, and its seismic performance was assessed before and after the retrofit. The results show that the developed steel frame assembly was effective in increasing seismic load resisting capability of the structure, and the PSO algorithm could be applied as convenient optimization tool for seismic retrofit design of structures.

고층 RC 벽식 비정정 구조물의 지진거동에 관한 실험적 연구 (Experimental Study on the Seismic Response of High-Rise RC Bearing-Wall Structures with Irregularity)

  • 이한선;고동우
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.321-328
    • /
    • 2003
  • The objective of this study is to investigate the seismic response of high-rise RC bearing-wall structures with irregularity. For this purpose, three 1:12 scale 17-story reinforced concrete model structures were constructed according to the similitude law, in which the upper 15 stories have a bearing-wall system while the lower 2-story frames have three different layouts of the plan : The first one is a moment-resisting frame system, the second has a infilled shear wall with symmetric plan and the third has a infilled shear wall with eccentricity, Then, these models were subjected to a series of earthquake excitations. The test results show the followings: 1) the existence of shear wall reduced greatly shear deformation at the piloti frame, but has almost the negligible effect on the reduction of the overturning-moment angle, 2) the frame with shear wall resists most of overturning moment in severe earthquake, 3) the torsional behavior is almost independent of the translational, 4) the absorbed energy due to the overturning deformation has the largest portion in the total absorbed energy.

  • PDF

Seismic progressive collapse assessment of 3-story RC moment resisting buildings with different levels of eccentricity in plan

  • Karimiyan, Somayyeh;Moghadam, Abdolreza S.;Vetr, Mohammad G.
    • Earthquakes and Structures
    • /
    • 제5권3호
    • /
    • pp.277-296
    • /
    • 2013
  • Margin of safety against potential of progressive collapse is among important features of a structural system. Often eccentricity in plan of a building causes concentration of damage, thus adversely affects its progressive collapse safety margin. In this paper the progressive collapse of symmetric and asymmetric 3-story reinforced concrete ordinary moment resisting frame buildings subjected to the earthquake ground motions are studied. The asymmetric buildings have 5%, 15% and 25% mass eccentricity. The distribution of the damage and spread of the collapse is investigated using nonlinear time history analyses. Results show that potential of the progressive collapse at both stiff and flexible edges of the buildings increases with increase in the level of asymmetry in buildings. It is also demonstrated that "drift" as a more easily available global response parameter is a good measure of the potential of progressive collapse rather than much difficult-to-calculate local response parameter of "number of collapse plastic hinges".