• 제목/요약/키워드: RC frame reinforced with damper

검색결과 16건 처리시간 0.027초

철근콘크리트 골조와 강재댐퍼의 강성비 및 내력비에 따른 내진보강 성능 (Performance of Seismic Retrofit According to the Stiffness and Strength Ratios of Steel Damper to Reinforced Concrete Frame)

  • 백은림;오상훈;이상호
    • 한국지진공학회논문집
    • /
    • 제17권4호
    • /
    • pp.171-180
    • /
    • 2013
  • The purpose of this study is to evaluate the effectiveness of the seismic retrofit performance for a reinforced concrete structure with steel damper. The nonlinear static analysis of the RC frame specimens with and without retrofit using the steel damper was conducted and the reliability of the analysis was verified by comparing the analysis and test results. Using this analysis model and method, additional nonlinear analysis was conducted considering varying stiffness and strength ratios between RC frame and steel damper and the failure mode of RC frame. As the result of the study, the total absorbed energy increased and the damage of RC frame was reduced as stiffness and strength ratios increased. The seismic retrofit performance, evaluated by means of the yield strength, increasing ratio of the absorbed energy and damage of the frame, increased linear proportionally with the increase of the strength ratio. In addition, the seismic retrofit performance was stable for stiffness ratios larger than 4~5. The energy absorption capacity of the frame governed by shear failure was better than that of the frame governed by flexure failure.

RC 골조에 보강된 강재프레임과 강재댐퍼의 성능 평가 (Performance Evaluation of Steel Frame and Steel Damper Reinforced in RC frame)

  • 이현호
    • 한국공간구조학회논문집
    • /
    • 제23권1호
    • /
    • pp.77-84
    • /
    • 2023
  • In this study, the performance evaluation of the RC frame specimen (RV2) which was strengthened by a steel frame and a steel damper with the lateral deformation prevention details proceeded. The comparison objects are bare frame specimen (BF), RV2 and AWD, where AWD is a specimen reinforced with steel damper and aramid fiber sheets. In the evaluation of envelope curve, stiffness degradation, and energy dissipation capacity, RV2 was evaluated to have excellent capacity as a whole. To evaluate the strengthening effect of the steel frame based on the maximum strength and energy dissipation capacity, it was evaluated to have a 38% of the RV2's capacity.

S형 스트럿 강재 댐퍼 보강에 의한 RC 골조의 내진성능 향상 (Seismic Resisting Capacity Enhancement by S Type Strut Steel Damper Strengthening)

  • 이현호
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.43-50
    • /
    • 2018
  • The purpose of this study is to improve the seismic performance of RC framed buildings such as piloti buildings and school facilities. For this purpose, a half size RC frame specimen (SFD) was made and the inside of frame was reinforced with steel frame and S type strut steel damper. The experimental results are compared with those of the previous studies under the same conditions. The comparative specimens are non-reinforced specimen (BF) and damper reinforced specimen (AFD) that confined the column with an aramid sheet. As a result of comparing the maximum strength, stiffness degradation and energy dissipation capacity, SFD specimen was evaluated to be better than comparative specimens. According to the experimental results and FE analysis results, it was confirmed that the shear deformation was concentrated in the steel damper. And it was showed that cracks were concentrated at the upper and lower ends of the strut of the S type damper, and the final failure was observed at struts. From this, it was verified that the steel damper appropriately dissipates energy due to the lateral load.

TS 제진공법으로 내진보강된 철근콘크리트 골조의 내진성능(Part 1:해석적 연구) (Seismic Performance of RC Frame System Retrofitted with TS Seismic Strengthening Method (Part 1:Analytical Study))

  • 정명철;송정원;송진규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권2호
    • /
    • pp.141-147
    • /
    • 2018
  • 본 연구에서는 TS 내진보강공법의 내진보강 효과를 검증 할 목적으로 TS 댐퍼(Tension Spring-Damper)를 설치한 철근콘크리트 골조를 대상으로 한 반복 주기하중 재하 실험을 수행 하였다. 실험체는 기준 실험체인 무보강 골조 실험체와 3개의 보강 골조 실험체의 총 4개이며, 실험의 변수는 댐퍼 설치 여부, 댐퍼의 형상 및 시공방법이다. 그 결과 창호 내부 삽입 형식의 시공방법이 강도와 강성의 측면에서 2배가량, 외부 부착형식의 시공 방법이 에너지 소산의 측면에서 2배가량의 성능 향상을 나타내어 TS 내진보강공법이 현장 적용성과 내진보강 효과가 우수한 공법임을 확인 할 수 있었다.

더블 I형 감쇠장치로 보강한 비내진 RC 골조의 내진성능 평가 (Seismic Capacity of Non-seismic Designed RC Framed Building Retrofitted by Double I-type Metallic Damper)

  • 허무원;천영수;황재승;김종호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.10-17
    • /
    • 2015
  • 본 연구에서는 내진설계 이전에 지어진 학교 건물을 대상으로 내진보강효과를 알아보기 위하여 벽체로 지지되는 강재이력형 감쇠장치를 설치하여 기존 비내진 설계된 보강 RC골조 실험결과와 비교 분석하였다. 실험결과, 비내진 설계된 실험체는 좌 우측 기둥의 상 하부에 피해가 집중되면서 급격한 강도저하와 함께 취성적인 전단파괴의 양상을 나타낸 반면, 더블 I형 감쇠장치를 보강한 실험체는 감쇠장치 보강으로 강도 및 강성의 증가와 함께 탄소성 거동을 보이면서 에너지 흡수 능력이 큰 타원형의 이력특성을 나타내었다. 또한, 두 실험체의 강성저하를 비교한 결과 더블 I형 감쇠장치를 보강한 실험체가 강성저하를 방지하는데도 효과적임을 알 수 있었다. 에너지소산능력도 더블 I형 감쇠장치를 보강한 실험체가 비보강 실험체에 비해 약 3.5배의 향상된 결과를 나타내었다. 이러한 에너지소산능력의 증진은 내력과 변형 능력의 증진에 따른 결과라고 사료된다.

유사동적실험에 의한 외부접합형 카고메 트러스 제진장치가 설치된 RC 라멘조 공동주택의 내진성능 평가 (Seismic Performance Evaluation of R/C Frame Apartment Strengthened with Kagome Truss Damper External Connection Method by Pseudo Dynamic Test)

  • 허무원;천영수;황재승;이강석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.23-34
    • /
    • 2015
  • 최근 새로운 3차원 와이어 다공질 형태의 카고메 트러스 이력형 제진장치가 개발되어, 건축물의 내진성능 개선을 위한 제진장치로서의 적용가능성이 재료실험을 통하여 검증되었다. 본 연구에서는 카고메 트러스 이력형 제진장치를 RC 라멘조 공동주택에 외부접합 한 새로운제진구조시스템을 제안하였다. 카고메 외부접합형 제진구조시스템은 대상건물, 카고메 제진장치, 지지구조물로 구성되어 있으며, 기존 층간에 설치된 제진시스템과 달리 외부 지지 구조물과 대상 건축물의 상호작용을 이용하여 제진장치가 지진 에너지를 흡수하는 시스템이다. 본 연구에서 제안한 카고메 외부접합형 제진공법의 유효성을 검증 할 목적으로 LH공사 시범적용용 RC 라멘조 20층 공동주택의 골조를 대상으로 유사동적실험을 실시하여 내진성능 개선효과를 검토하였다. 그 결과, 국내에서 발생 가능한 지진규모 (200gal)에서 비보강 골조는 중규모의 지진피해가 예상되었지만, 카고메 외부접합형 제진보강법으로 보강한 골조는 경미한 지진피해가 예상되었으며, 대규모 지진(300gal)을 상정한 경우에도 중규모 이하의 지진피해가 예상되어 본 연구에서 개발한 카고메 제진보강법의 내진성능 개선 효과의 유효성이 검증되었다고 사료된다.

Performance based plastic design of friction damped RC building

  • Mithu Dey;Md Saniyal Alam
    • Advances in concrete construction
    • /
    • 제17권4호
    • /
    • pp.221-232
    • /
    • 2024
  • As a supplemental energy dissipation device, friction dampers are widely employed to augment the behaviour of buildings under seismic forces. In the current work, a methodology for the design of the friction damping system of RC frame buildings is offered using performance-based plastic design (PBPD) method. Here 2% of maximum interstorey drift ratio for life safety (LS) level is taken into account as a target drift to estimate the design base shear. In this approach, the distribution of friction damper is determined based on the hysteretic energy demand of that storey. Two frames, five storey three bay (5S3B) and eight storey three bay (8S3B) RC frame building with and without friction damping systems are also taken up for the investigation. The suggested design approach is validated by the nonlinear time history analysis (NLTHA) procedure. Inter story drift ratio (ISDR) and storey displacement, which are the more closely related to structural damage during seismic excitation are evaluated. The results show that the friction damping system on a retrofitted RC frame building performs effectively under seismic excitations and that storey displacement and ISDR are within the limit at moderate and high seismic intensities.

내부 철골끼움골조 및 벽체형 마찰댐퍼(WFD)로 보강된 2층 철근콘크리트골조 내진성능에 대한 실험적 연구 (An Experimental Study on Seismic Performance of Two-story Reinforced Concrete Frames Retrofitted with Internal Steel Frame and Wall Type Friction Damper)

  • 유창기;최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.64-72
    • /
    • 2022
  • 본 연구에서는 WFD(Wall Friction Damper)를 보강한 철근콘크리트 골조의 내진성능을 확인하기 위해 2층 철근콘크리트 골조 의 보강방법(무보강, 내부 H- 형철골과 WFD보강)을 주요 변수로 하였다. WFD 내진 보강 공법은 강도 향상과 에너지 소산 공법을 혼합한 것이다. WFD의 충분한 에너지 소산 이전에 보강재와 기존 구조물의 접합부에서 사전 파괴를 방지하기 위해 내부 H형 철골과 보 측면을 관통하는 케미컬 앵커를 사용하여 WFD를 설치하였다. 시험결과 OMF-N 시험체는 최대강도 발현 후 R/C 기둥의 전단력에 의한 취성파괴 양상을 보였다. OMF-ALL(H) 실험체는 핀칭 효과의 감소와 RC 기둥의 파손이 발생함을 보였다. 또한 OMF-ALL(H)의 최대 강도, 누적 에너지 소산 및 연성은 OMF-N의 경우 3.01배, 7.2배 및 1.72배 증가하였다. 그 결과 철근콘크리트 구조물에 시공한 WFD 내진 보강공법이 내진성능을 향상시키고 보강효과가 유효한 것으로 나타났다.

Large-scale cyclic test on frame-supported-transfer-slab reinforced concrete structure retrofitted by sector lead rubber dampers

  • Xin Xu;Yun Zhou;Zhang Yan Chen;Da yang Wang;Ke Jiang;Song Wang
    • Earthquakes and Structures
    • /
    • 제26권5호
    • /
    • pp.383-400
    • /
    • 2024
  • For a conventionally repaired frame-supported-transfer-slab (FSTS) reinforced concrete (RC) structure, both the transfer slab and the beam-to-column and transfer slab-to-column joints remain vulnerable to secondary earthquakes. Aimed at improving the seismic performance of a damaged FSTS RC structure, an innovative retrofitting scheme is proposed, which adopts the sector lead rubber dampers (SLRDs) at joints after the damaged FSTS RC structure is repaired by conventional approaches. In this paper, a series of quasi-static cyclic tests was conducted on a large-scale retrofitted FSTS RC structure. The seismic performance was evaluated and the key test results, including deformation characteristics, damage pattern, hysteretic behaviour, bearing capacity and strains on key components, were reported in detail. The test results indicated that the SLRDs started to dissipate energy under the service level earthquake, and thus prevented damages on the beam-to-column and transfer slab-to-column joints during the secondary earthquakes and shifted the plastic hinges away from the beam ends. The retrofitting scheme of using SLRDs also achieved the seismic design concept of 'strong joint, weak component'. The FSTS RC structure retrofitted by the SLRDs could recover more than 85% bearing capacity of its undamaged counterpart. The hysteresis curves were featured by the inverse "S" shape, indicating good bearing capacity and hysteresis performance. The deformation capacity of the damaged FSTS RC structure retrofitted by the SLRDs met the corresponding codified requirements for the case of the maximum considered earthquake, as set out in the Chinese seismic design code. The stability of the FSTS RC structure retrofitted by the SLRDs, which was revealed by the developed stains of the RC frame and transfer slab, was improved compared with the undamaged FSTS RC structure.

An experimental study on a steel multi-slit damper for seismic retrofit of soft-first story structures

  • Mohammad Mahdi Javidan;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.721-734
    • /
    • 2024
  • In this research, the efficiency of a metallic energy dissipation device for seismic retrofit of an existing structure is evaluated by cyclic loading test. The proposed device, which is called multi-slit damper, is made of weak and strong slit dampers connected in series. Its energy dissipation mechanism consists of two stages: (i) yielding of the weak-slit damper under minor earthquakes; (ii) restraint of further deformations of the weak slit damper and activation of the strong slit damper under major earthquakes using a gap mechanism. A reinforced concrete (RC) frame with characteristics similar to soft-first-story structures is tested under cyclic loading before and after retrofit using the proposed device. The details of the experimental study are described and the test is simulated in an available commercial software to validate the analytical model of the damper. To further verify the applicability of the damper, it is applied to an analysis model of a 4-story structure with soft first story and its seismic performance is evaluated before and after retrofit. The experimental and analysis results show that the multi-slit damper is effective in controlling seismic response of structures.