• 제목/요약/키워드: RC T beam

검색결과 61건 처리시간 0.021초

Joint Shear Behavior Prediction for RC Beam-Column Connections

  • LaFave, James M.;Kim, Jae-Hong
    • International Journal of Concrete Structures and Materials
    • /
    • 제5권1호
    • /
    • pp.57-64
    • /
    • 2011
  • An extensive database has been constructed of reinforced concrete (RC) beam-column connection tests subjected to cyclic lateral loading. All cases within the database experienced joint shear failure, either in conjunction with or without yielding of longitudinal beam reinforcement. Using the experimental database, envelope curves of joint shear stress vs. joint shear strain behavior have been created by connecting key points such as cracking, yielding, and peak loading. Various prediction approaches for RC joint shear behavior are discussed using the constructed experimental database. RC joint shear strength and deformation models are first presented using the database in conjunction with a Bayesian parameter estimation method, and then a complete model applicable to the full range of RC joint shear behavior is suggested. An RC joint shear prediction model following a U.S. standard is next summarized and evaluated. Finally, a particular joint shear prediction model using basic joint shear resistance mechanisms is described and for the first time critically assessed.

Fiber method analysis of rc beam retrofitted with turnbuckle external post-tensioning

  • Lejano, Bernardo A.
    • Computers and Concrete
    • /
    • 제17권1호
    • /
    • pp.67-86
    • /
    • 2016
  • Strengthening as well as correcting unsightly deflections of reinforced concrete (RC) beam may be accomplished by retrofitting. An innovative way to do this retrofitting that is proposed in this study utilizes turnbuckle to apply external post-tensioning. This Turnbuckle External Post-Tensioning (T-EPT) was experimentally proven to improve the serviceability and load carrying capacity of reinforced concrete beams. The T-EPT system comprises a braced steel frame and a turnbuckle mechanism to provide the prestressing force. To further develop the T-EPT, this research aims to develop a numerical scheme to analyze the structural performance of reinforced concrete beams with this kind of retrofitting. The fiber method analysis was used as the numerical scheme. The fiber method is a simplified finite element method that is used in this study to predict the elastic and inelastic behavior of a reinforced concrete beam. With this, parametric study was conducted so that the effective setup of doing the T-EPT retrofitting may be determined. Different T-EPT configurations were investigated and their effectiveness evaluated. Overall, the T-EPT was effective in improving the serviceability condition and load carrying capacity of reinforced concrete beam.

Shear strengthening effect by bonded GFRP strips and transverse steel on RC T-beams

  • Panda, K.C.;Bhattacharyya, S.K.;Barai, S.V.
    • Structural Engineering and Mechanics
    • /
    • 제47권1호
    • /
    • pp.75-98
    • /
    • 2013
  • This study focuses on shear strengthening performance of simply supported reinforced concrete (RC) T-beams bonded by glass fibre reinforced polymer (GFRP) strips in different configuration, orientations and transverse steel reinforcement in different spacing. Eighteen RC T-beams of 2.5 m span are tested. Nine beams are used as control beam. The stirrups are provided in three different spacing such as without stirrups and with stirrups at a spacing of 200 mm and 300 mm. Another nine beams are used as strengthened beams. GFRP strips are bonded in shear zone in U-shape and side shape with two types of orientation of the strip at $45^{\circ}$ and $90^{\circ}$ to the longitudinal axis of the beam for each type of stirrup spacing. The experimental result indicates that the beam strengthened with GFRP strips at $45^{\circ}$ orientation to the longitudinal axis of the beam are much more effective than $90^{\circ}$ orientation. Also as transverse steel increases, the effectiveness of the GFRP strips decreases.

Shear behaviour of RC T-beams strengthened with U-wrapped GFRP sheet

  • Panda, K.C.;Bhattacharyya, S.K.;Barai, S.V.
    • Steel and Composite Structures
    • /
    • 제12권2호
    • /
    • pp.149-166
    • /
    • 2012
  • This paper presents an experimental investigation on the performance of 2.5 m long reinforced concrete (RC) T-beams strengthened in shear using epoxy bonded glass fibre fabric. Eighteen (18) full scale, simply supported RC T-beams are tested. Nine beams are used as control beam specimens with three different stirrups spacing without glass fibre reinforced polymer (GFRP) sheet and rest nine beams are strengthened in shear with one, two, and three layers of GFRP sheet in the form of U-jacket around the web of T-beams for each type of stirrup spacing. The objective of this study is to evaluate the effectiveness, the cracking pattern and modes of failure of the GFRP strengthened RC T-beams. The test result indicates that for RC T-beams strengthened in shear with U-jacketed GFRP sheets, increase the load carrying capacity by 10-46%.

CFRP strengthening of continuous RC T-beams at hogging moment zone across the flange

  • Eldin, Mohammad Mohie;Tarabia, Ahmed M.;Hasson, Rahma F.
    • Structural Engineering and Mechanics
    • /
    • 제64권6권
    • /
    • pp.783-792
    • /
    • 2017
  • Carbon Fiber Reinforced Polymer (CFRP) laminates are used widely either for repairing or strengthening of existing structures. When CFRP laminates are used for strengthening of RC continuous T-beams in the Hogging Moment Zone (HMZ); above and around the intermediate supports, it is important to study the expected positions of the laminates across the width of the beam flange. Although, it is traditional to consider CFRP laminates added above the beam web, this is not practical since walls and columns are located in such positions in general. This paper examines the effect of changing the positions of CFRP laminates used for the strengthening of the hogging moment zone across the beam flange of two-span-T-section beams. The Finite Element (FE) Package ANSYS is used to create 3-D theoretical models needed for the study. It can be concluded that changing the position of CFRP strengthening across the beam flange, in the hogging moment zone, is effective upon the overall behavior. The best locations are either above the web or at the flange just beside the web, due to the presence of walls and/or columns.

기둥관통형 RC 기둥-철골 보 접합부에 관한 실험적 연구 (An Experimental Study on Column Penetration Joint of RC Column-Steel Beam)

  • 김승훈;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.475-480
    • /
    • 1998
  • The composite framed structures, consisting of RC columns and steel beams more popular in korea because of their efficiency and quality. However the force transfer mechanisms between the column and beam may by very complicated since the materials of columns and beams are different. This study develops "the column penetration joint" which the web of steel beam doesn't penetrate and which could improve the strength, deformation, and energy dissipation capacities compared to existing composite joints. It is the concrete-filled square tube joint with the exterior diaphragms and the cruciform stiffening plates. This study evaluated the strength of RC column penetration to steel beam connection by analyzing the results of partial experiments, and reviewed the applicability the strength formula through the comparison of tested results of joint experiment.

  • PDF

Influence of shear deformation of exterior beam-column joints on the quasi-static behavior of RC framed structures

  • Costa, Ricardo J.T.;Gomes, Fernando C.T.;Providencia, Paulo M.M.P.;Dias, Alfredo M.P.G.
    • Computers and Concrete
    • /
    • 제12권4호
    • /
    • pp.393-411
    • /
    • 2013
  • In the analysis and design of reinforced concrete frames beam-column joints are sometimes assumed as rigid. This simplifying assumption can be unsafe because it is likely to affect the distributions of internal forces and moments, reduce drift and increase the overall load-carrying capacity of the frame. This study is concerned with the relevance of shear deformation of beam-column joints, in particular of exterior ones, on the quasi-static behavior of regular reinforced concrete sway frames. The included parametric studies of a simple sub-frame model reveal that the quasi-static monotonic behavior of unbraced regular reinforced concrete frames is prone to be significantly affected by the deformation of beam-column joints.

2층 RC 전단벽식 구조물의 내진성능에 대한 정적 실험 (Static Experiment for the Seismic Performance of a 2 Story RC Shear Wall System)

  • 이상호;오상훈;황원태;이경보;이한선
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.55-65
    • /
    • 2010
  • 본 실험 연구의 목적은 횡방향 정적가력을 통하여 2층 R.C 전단벽식 구조의 내진성능을 평가하는 것이다. 본 연구의 실험체는 대상 건물의 개구부를 가지는 T자형 벽체 1층과 2층의 일부분을 대상으로 실물크기의 3/5 크기정도로 축소하였고, 인방보의 유 무를 실험변수로한 2개의 실험체를 제작하여 횡방향의 정적가력 실험을 수행하였다. 인방보 유무에 따른 벽체의 구조적 성능 및 거동의 차이를 비교한 결과, 인방보가 있는 실험체가 인방보가 없는 실험체보다 최대내력과 연성능력 등의 내진성능이 우수한 것으로 판단되었다.

비내진설계된 우리나라 RC 외부 접합부의 횡저항 능력에 관한 실험 (Experiments of the Lateral Loading Capacity of Exterior Joints of Non-seismically Designed RC Frames in Korea)

  • 이영욱;박형권
    • 한국지진공학회논문집
    • /
    • 제14권4호
    • /
    • pp.29-36
    • /
    • 2010
  • 국내 비내진 설계된 RC 골조 외부접합부의 횡저항 능력특성을 연구하기 위하여, 1988년 이후의 건물을 대상으로 실물 크기의 70%의 T형 보-기둥 실험체 4개를 제작하여 보에 횡력을 가력하여 실험을 수행하였다. 작용한 횡력은 총 9단계로 변위를 조절하여 최대 횡변위비 3.5%까지 가력하였고, 각 변위 단계마다 3싸이클의 반복하중을 가력하였다. 실제의 상황과 유사하게 하기 위하여 실험동안 기둥에 압축력을 지속적으로 작용하였다. 실험 결과, 부재가 휨 공칭강도에 도달하여야 하는 내력에 비하여 실험 결과는 85%이하로 나타났고 층간변위비 0.85% 미만에서 모든 실험체의 접합부에서 전단균열이 발생하여 국내 외부접합부가 취약함을 확인할 수 있었다. 또한 접합부 균열발생시 주응력-층간변위비는 Priestly의 제안식과 유사하게 나타났다.

Predicting residual moment capacity of thermally insulated RC beams exposed to fire using artificial neural networks

  • Erdem, Hakan
    • Computers and Concrete
    • /
    • 제19권6호
    • /
    • pp.711-716
    • /
    • 2017
  • This paper presents a method using artificial neural networks (ANNs) to predict the residual moment capacity of thermally insulated reinforced concrete (RC) beams exposed to fire. The use of heat resistant insulation material protects concrete beams against the harmful effects of fire. If it is desired to calculate the residual moment capacity of the beams in this state, the determination of the moment capacity of thermally insulated beams exposed to fire involves several consecutive calculations, which is significantly easier when ANNs are used. Beam width, beam effective depth, fire duration, concrete compressive and steel tensile strength, steel area, thermal conductivity of insulation material can influence behavior of RC beams exposed to high temperatures. In this study, a finite difference method was used to calculate the temperature distribution in a cross section of the beam, and temperature distribution, reduction mechanical properties of concrete and reinforcing steel and moment capacity were calculated using existing relations in literature. Data was generated for 336 beams with different beam width ($b_w$), beam account height (h), fire duration (t), mechanical properties of concrete ($f_{cd}$) and reinforcing steel ($f_{yd}$), steel area ($A_s$), insulation material thermal conductivity (kinsulation). Five input parameters ($b_w$, h, $f_{cd}$, $f_{yd}$, $A_s$ and $k_{insulation}$) were used in the ANN to estimate the moment capacity ($M_r$). The trained model allowed the investigation of the effects on the moment capacity of the insulation material and the results indicated that the use of insulation materials with the smallest value of the thermal conductivities used in calculations is effective in protecting the RC beam against fire.