• 제목/요약/키워드: RC 보-기둥 접합부

검색결과 76건 처리시간 0.022초

기둥관통형 RC 기둥-철골 보 접합부에 관한 실험적 연구 (An Experimental Study on Column Penetration Joint of RC Column-Steel Beam)

  • 김승훈;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.475-480
    • /
    • 1998
  • The composite framed structures, consisting of RC columns and steel beams more popular in korea because of their efficiency and quality. However the force transfer mechanisms between the column and beam may by very complicated since the materials of columns and beams are different. This study develops "the column penetration joint" which the web of steel beam doesn't penetrate and which could improve the strength, deformation, and energy dissipation capacities compared to existing composite joints. It is the concrete-filled square tube joint with the exterior diaphragms and the cruciform stiffening plates. This study evaluated the strength of RC column penetration to steel beam connection by analyzing the results of partial experiments, and reviewed the applicability the strength formula through the comparison of tested results of joint experiment.

  • PDF

철근 콘크리트 기둥과 철골 보 접합부의 거동 평가틀 위한 해석적 연구 (The Analytical Study on the Structural Performance of Beam-Column Connections of RC Column and Steel Beam)

  • 홍성헌;한상환;류천;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.110-116
    • /
    • 1998
  • The three-dimensional nonlinear analysis on the partial tension experiment of Beam-Column connections in hybrid connections with RC columns and S beams is simulated. In this paper, mechanical characteristics between steel plates and concrete is investigated. Also the stress transfer mechanism prior to beam-column connection analysis was considered by using joint element.

  • PDF

부착-슬립을 고려한 철근콘크리트 접합부의 이력 손상 모델 개발 (Hysteretic Damage Model for Reinforced Concrete Joints Considering Bond-Slip)

  • 김도연;최인길
    • 대한토목학회논문집
    • /
    • 제28권4A호
    • /
    • pp.517-528
    • /
    • 2008
  • 이 논문에서는 철근과 콘크리트 사이의 부착-슬립을 실제적으로 고려한 철근콘크리트 접합부의 이력 손상 모델을 제안하였다. 슬립을 가시화하기 위해 콘크리트와 철근의 변위장이 서로 다른 프레임 요소를 개발하였다. 파이버 단면 개념으로부터 콘크리트, 철근 그리고 부착에 대한 적합방정식을 정의하였다. 부분적인 제하 및 재재하 상태를 고려하기 위해 철근 이력곡선의 수정이 이루어졌다. 단조증가 상태의 국부적 부착응력-슬립 관계는 손상 계수에 따라 슬립이 역전될 때마다 갱신하였다. 구속된 콘크리트에 매입된 철근 시험체와 기초에 정착된 철근콘크리트 기둥 시험체, 그리고 보-기둥 부재의 수치해석을 통해 모델의 정확성을 검증하였고, 부착-슬립 효과를 고려함으로써 하중 이력에 따른 에너지 소산 정도를 평가할 수 있었다.

지진하중을 받는 철근콘크리트 접합부의 강도 (Strength of Reinforced Concrete Beam-Column Assembles Subjected to Seismic Loading)

  • 이정윤;채희대
    • 한국지진공학회논문집
    • /
    • 제10권5호
    • /
    • pp.25-33
    • /
    • 2006
  • 본 논문에서는 지진하중을 받는 내부 및 외부 철근콘크리트 보-기둥 접합부의 강도 및 연성능력을 평가하였다. 접합부에 인접한 보에 소성힌지가 발생한 이후 접합부가 파괴할 경우 접합부 내력은 보의 소성힌지의 영향을 받아 감소하게 된다. 보에 소성힌지가 발생하면 보의 부재축방향 변형률은 급격하게 증가하게 되며, 증가된 부재축방향 변형률은 접합부의 변형에 영향을 주어 접합부의 강도를 저감시킨다. 이 논문에서는 보에 소성힌지가 발생하기 이전에 파괴하는 접합부의 내력과 보에 소성힌지가 발생한 이후에 파괴하는 접합부의 연성능력을 접합부의 변형능력 및 스트럿의 강도저감을 이용하여 평가하였다. 제시한 평가법은 52개의 접합부 실험체를 이용하여 검증하였다.

U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel)

  • 하수경;손국원;유승룡;주호성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.18-28
    • /
    • 2015
  • 이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는데 있다. 1개의 무 보강 보-기둥 실험체와 U형 PC 패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커 접합부 실험체는 전단 파괴될 것으로 해석되었고 철판 용접 접합부 실험체는 휨 파괴할 것으로 예측되었다. 실험체의 종국 내력은 상부 접합부의 전단 내력과 PC 패널 절곡 부 휨 위험단면에서 휨 내력 중 약한 것으로 결정되었다. 이 실험체에서, 한쪽 RC기둥이 가 하중(미는 실험 하중)을 받아 PC 패널 부재를 밀게 된다면, 다른 쪽 내부 수직부재는 상부 전단 접합부로부터 부 하중(당기는 실험 하중)을 받게 되어있었다. 가 하중을 받는 2개의 부재는 합성 휨 거동이 지배적이므로 합성단면의 휨 내력이 실험체의 최종 내력을 결정하게 되지만, 이 경우 최종 내력에 대하여 상부 전단 접합부 강도의 직접적인 영향은 없다고 볼 수 있다. 그러나 부 하중(당기는 하중)을 받는 RC 기둥과 PC 패널 부재는 비합성 거동이 지배적이고 실험체의 최종 내력은 상부 전단 접합부 전단내력의 크기에서 직접 영향을 받는 것으로 파악되었다. ACI 318M-11 Appendix-D 앵커 전단설계에 기초한 전단내력 그리고 실험에서 얻은 최대하중을 적용하여 마이다스 젠 탄성설계에 의하여 계산한 전단 외력에 대한 비교 해석결과는 실험결과와 일치하는 해석결과를 보여주었다.

CFRP로 보강된 비내진 철근콘크리트 보-기둥 접합부의 내진성능 실험 (Experimental evolution of RC beam-column joints strengthened with CFRP)

  • 김민;이기학;이재홍;우성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.106-109
    • /
    • 2006
  • It has been shown that many reinforced concrete(RC) structures designed without seismic details have experienced brittle shear failures in the beam-column joint area and may result in large permanent deformations and structural collapse. In this study, experimental investigations for RC beam-column joints strengthened with the carbon fiber-reinforced polymer(CFRP) under cyclic loadings were presented. The use of CFRP in the joint was varied to determine the effective way of improving the structural performances of RC joints. Ten RC beam-column joints were designed and tested with cyclic loadings. The experimental results showed that the use of CFRP in RC joints would be very effective solutions to improve the seismic performances of the non-seismic RC joints. All of the non-seismic design specimens strengthened with CFRP sheets showed the significant increase of strength and ductility.

  • PDF

내진성능평가시 횡보강근이 없는 RC 보-기둥 접합부의 전단내력 평가 (Seismic Assessment of Shear Capacity of RC Beam-Column Joints Without Transverse Re-bars)

  • 이영욱
    • 한국지진공학회논문집
    • /
    • 제23권5호
    • /
    • pp.249-259
    • /
    • 2019
  • To study the seismic resistance of the shear capacity of the RC beam-column joints of two-story and four-story RC buildings, sample buildings are designed with ordinary moment resisting frame. For the shear capacity of joints, the equations of FEMA 356 and NZ seismic assessment are selected and compared. For comparison, one group of buildings is designed only for gravity loads and the other group is designed for seismic and gravity loads. For 16 cases of the designed buildings, seismic performance point is evaluated through push-over analysis and the capacity of joint shear strength is checked. Not only for the gravity designed buildings but also for seismic designed buildings, the demand of joint shear is exceeding the capacity at exterior joints. However, for interior joint, the demand of joint shear exceeds the capacity only for one case. At exterior joints, the axial load stress ratio is lower than 0.21 for gravity designed buildings and 0.13 for seismic designed buildings.

혼합구조로 이루어진 보-기둥 접합부의 구조적 거동 특성 (The Properties for Structural Behavior of Beam-Column Joint Consisting of Composite Structure)

  • 이승조;박정민;김화중
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.445-455
    • /
    • 2000
  • 본 연구는 최근의 건설 환경 변화에 따른 여러 가지 제문제점들에 대한 구조적 측면에서의 대응책의 하나로서 새로운 구조 시스템 전개를 위해 이종구조부재로 구성된 보기둥 접합부 모델을 제안한 것이다. 본 연구에서는 장스팬 S보의 강성을 향상시키기 위해 S조의 단부를 RC조로 보강하여 강성 및 내력증대를 꾀하였으며, 이종구조 사이의 원활한 응력 전달을 목적으로 SRC조 단부의 보 주근은 U자형 갈고리 모양으로 정착하여 철골 플랜지에 용접 접합하였다. 일련의 실험을 통해 접합부 강성 및 내력 특성을 고찰하였고 본 접합부의 가능성을 제시하였다.

  • PDF

베라이트 시멘트를 이용한 고강도 철근콘크리트 보-기둥 접합부의 이력특성 (Hysteretic Behavior of RC Beam-Column Joint for High Strength Structures using Belite Cement)

  • 배흥한;이상원;윤정배;김기수;이세웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.582-588
    • /
    • 1998
  • The experimental study for the interior beam-column joint for high strength conccrete using Belite cement is presented. Test parameters are compressive strength, flexual strength ratio and joint shear stresslevel. The results from cyclic loading tests show different behaviors from the various parameters. Also, The different behaviors on beam-column joint can be achived by the different concrete strength.

  • PDF

반복하중을 받는 강섬유 보강 철근콘크리트 외부 접합부의 거동 특성 (Behavior of Steel Fiber-Reinforced Concrete Exterior Connections under Cyclic Loads)

  • 권우현;김우석;강현구;홍성걸;곽윤근
    • 콘크리트학회논문집
    • /
    • 제23권6호
    • /
    • pp.711-722
    • /
    • 2011
  • 횡보강근이 적게 포함된 보통강도 철근콘크리트 보-기둥 접합부에서 강섬유의 보강효과에 관한 실험적 연구를 진행하였다. 이를 규명하기 위해 총 10개의 접합부 실험체를 제작하였으며, 접합부 횡보강근량과 강섬유 혼입률($V_f$ = 0%, 1%, 1.5%)을 주요변수로 실험하였다. 실험은 총 19싸이클의 반복주기하중의 형태로 가력되었으며 각 싸이클의 반복회수는 2싸이클씩 준정적 지진하중의 형태로 적용되었다. 실험 결과를 통해 보통 강도 철근콘크리트 보-기둥 접합부에 강섬유를 보강함으로써 횡보강근 감소에 따른 피해정도를 어느 정도 줄일 수 있다는 결론을 얻었고, 또한 강섬유 보강으로 접합부 전단강도를 증가시킬 수 있고 동시에 에너지소산능력을 향상시킬 수 있다는 결론을 도출하였다. 보다 정량적인 평가를 위해 이 연구의 시험체들과 기존의 보-기둥 접합부 RC 시험체들에서 측정된 최대 접합부 전단강도값과 ACI 352R-02의 설계기준식, Jiuru et al.의 제안식, 그리고 Kim et al.의 제안식을 비교 분석하였다. 이러한 분석 결과 Jiuru et al.의 전단강도 제안식이 실험 결과를 과대평가하는데 반해 Kim et al.의 전단강도 제안식은 모든 시험체에 대해 안정적인 결과와 적은 오차범위를 나타내었다. 따라서, 이 연구를 바탕으로 해서 적절한 접합부 배근상세와 함께 강섬유 보강 철근콘크리트 보-기둥 접합부에 대한 추가적인 연구가 진행된다면, 횡보강근의 감소를 통한 시공의 어려움 해소 및 내진성능의 향상이 가능할 것으로 판단된다.