• Title/Summary/Keyword: RBC-red blood cell

Search Result 270, Processing Time 0.031 seconds

Shear induced damage of red blood cells monitored by the decrease of their deformability

  • Lee, Sung Sik;Ahn, Kyung Hyun;Lee, Seung Jong;Sun, Kyung;Goedhart, Petrus T.;Hardeman, Max. R.
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.3
    • /
    • pp.141-146
    • /
    • 2004
  • Shear-induced damage of Red Blood Cell (RBC) is an imminent problem to be solved for the practical application of artificial organs in extra corporeal circulation, as it often happens and affects physiological homeostasis of a patient. To design and operate artificial organs in a safe mode, many investigations have been set up to correlate shear and shear-induced cell damage. Most studies were focused on hemolysis i.e. the extreme case, however, it is important as well to obtain a clear understanding of pre-hemolytic mechanical damage. In this study, the change in deformability of RBC was measured by ektacytometry to investigate the damage of RBC caused by shear. To a small magnitude of pre-shear, there is little difference, but to a large magnitude of pre-shear, cell damage occurs and the effect of shear becomes significant depending on both the magnitude and imposed time of shearing. The threshold stress for cell damage was found to be approximately 30 Pa, which is much less than the threshold of mechanical hemolysis but is large enough to occur in vitro as in the extra corporeal circulation during open-heart surgery or artificial heart. In conclusion, it was found and suggested that the decrease of deformability can be used as an early indication of cell damage, in contrast to measuring plasma hemoglobin. As cell damage always occurs during flow in artificial organs, the results as well as the approach adopted here will be helpful in the design and operation of artificial organs.

Statistical Analysis of 3D Volume of Red Blood Cells with Different Shapes via Digital Holographic Microscopy

  • Yi, Faliu;Lee, Chung-Ghiu;Moon, In-Kyu
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.115-120
    • /
    • 2012
  • In this paper, we present a method to automatically quantify the three-dimensional (3D) volume of red blood cells (RBCs) using off-axis digital holographic microscopy. The RBCs digital holograms are recorded via a CCD camera using an off-axis interferometry setup. The RBCs' phase image is reconstructed from the recorded off-axis digital hologram by a computational reconstruction algorithm. The watershed segmentation algorithm is applied to the reconstructed phase image to remove background parts and obtain clear targets in the phase image with many single RBCs. After segmenting the reconstructed RBCs' phase image, all single RBCs are extracted, and the 3D volume of each single RBC is then measured with the surface area and the phase values of the corresponding RBC. In order to demonstrate the feasibility of the proposed method to automatically calculate the 3D volume of RBC, two typical shapes of RBCs, i.e., stomatocyte/discocyte, are tested via experiments. Statistical distributions of 3D volume for each class of RBC are generated by using our algorithm. Statistical hypothesis testing is conducted to investigate the difference between the statistical distributions for the two typical shapes of RBCs. Our experimental results illustrate that our study opens the possibility of automated quantitative analysis of 3D volume in various types of RBCs.

Hematological analysis of the Korean native cattle (Hanwoo) according to the period and method of grazing

  • Choe, Changyong;Jung, Young-Hun;Do, Yoon Jung;Kang, Hee-Sung;Yoo, Jae-Gyu;Kim, Chan-Lan;Kim, Ui-Hyung;Song, Ru-hui;Park, Jinho
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.3
    • /
    • pp.191-196
    • /
    • 2018
  • Blood tests have been used to develop treatment plans, such as disease diagnosis, treatment effect, and prognosis determination in livestock. The present study examined changes in the blood count, including RBCs, WBCs, and platelets, before and after grazing among the Korean native cattle grazing from spring to autumn. The study compared the blood count of livestock group (A, n=34) that returned from the rangeland to cowshed every evening and livestock group (B, n=21) that were not returned from the rangeland to cowshed every evening during the grazing period. Hematological parameters such as RBC, hemoglobin, hematocrit, MCV, and WBC, neutrophil, eosinophil, monocyte, and lymphocyte were determined using a blood cell analyzer. Livestock group (A) showed significant differences in the values of RBC, MCV, MCHC, WBC, EOS, and LYM. Livestock group (B) showed significant differences in the values of RBC, Hb, HCT, MCV, MCH, PLT, NEU, and BAS. In particular, the RBC count decreased after grazing when compared with that before grazing. Compared with that before grazing, low RBC count was maintained from the first to fifth month of grazing. The WBC count increased from the fourth month of grazing, whereas the EOS count increased from the second month of grazing. These results suggest that the values of RBC and WBC vary before and after grazing, and also with the grazing period. Furthermore, it is necessary to develop a detailed feeding management based on these values of blood analysis for livestock that are raised continuously in the rangeland.

The Correlation of Racing Performance with Pre-Race Blood Values in Thoroughbred Horses

  • Lee, Young-woo;Shim, Seung-tae;Song, Hee-eun;Hwang, Hye-shin;Seo, Jong-pil;Lee, Kyoung-kap
    • Journal of Veterinary Clinics
    • /
    • v.35 no.5
    • /
    • pp.190-194
    • /
    • 2018
  • Recently, the horse racing industry in Korea has developed rapidly with good betting turnover. One of the most important factors in enhancing the performance of racehorses is the study of equine exercise physiology. This study was performed to analyze the results of pre-race blood test on race day and evaluate its correlation with the race performance in Thoroughbred racehorses. Twenty-one, healthy 3- to 6-year-old Thoroughbred horses were used to collect blood samples and hematological and biochemical measurements were performed. Results were analyzed to identify its correlation with racing performance. Analysis of hematological profile of pre-race blood of the racehorses revealed that red blood cell indices including RBC, Hb, and PCV levels were elevated. Additionally, levels of AP, AST, and GGT were also elevated in pre-race blood of horses on race day. RBC, Hb, and PCV levels of high performance racehorses were significantly lower than those of low class racehorses. Moreover, the analysis of correlation between blood test results and racing ability-related categories have shown negative correlations for rating, placing strike rate, prize money per race, RBC, Hb, and PCV and positive correlations for G3F and PCV. Additionally, AST value was positively correlated to prize money per race. Thus, the results of this study show that red blood cell indices and AST are good parameters for evaluating racing performance of horses before the race.

Indirect calculation for volume of packed red cell(VPRC) by means of erythrocyte sedimentation rate(ESR) of diluted blood in dogs (개 회석혈의 적혈구침강율(ESR)에 의한 적혈구 침층용적(VPRC)치의 간접계산법)

  • Lee, Bang-whan;Park, Young-jun
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.2
    • /
    • pp.41-49
    • /
    • 1989
  • The study was undertaken to obtain indirect values of volume of packed red cell (VPRC) without centrifugation, using the erythrocyte sedimentation rate (ESR) of diluted blood in dogs. ESRs of diluted blood using the diluent of autologous plasma in which formed numerous RBC-rouleau clumps, autologous serum in which formed a few RBC-rouleau clumps, and 5% dextrose or 6% sucrose solutions in which formed numerous RBC-aggregation clumps, were accelerated. But, ESR of diluted blood using the 0.9% saline, D-S, ACD-B, CDP or D-PBS solutions were sluggish, because erythrocytes were dispersed in these diluents. Reliable values of VPRC on the basis of the correlating regressive equation to the ESR could be derived from values of$60^{\circ}$-angled-micro-ESR/40 min in the mixture, four parts of 5% dextrose solution and one part of whole blood. In the ESR values of diluted blood with low ratio, 1:1~3:1, $60^{\circ}$-micro-ESR was higher than $60^{\circ}$-Wintrobe-ESR. But, in the diluted blood with high ratio, 4:1~5:1, there was no different ESR values. For an aid of practical use, authers suggested a list of the $60^{\circ}$-micro-ESR/40 min in the diluted blood with equivalent VPRC of whole blood.

  • PDF

The Scattering Beam Measurement of the RBC and the Fabrication of the Micro Cell Biochip (적혈구의 산란빔 측정과 마이크로 세포 분석 바이오칩 제작)

  • Byun, In Soo;Kwon, Ki Jin;Lee, Joon Ha
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.116-121
    • /
    • 2014
  • Next future, The bio technology will be a rapidly developing. This paper is the scattering beam measurement of the red blood cell (RBC) and the fabrication of the micro cell biochip using the bio micro electro mechanical system (Bio-MEMS) process technology. The Major process method of Bio-MEMS technology was used the buffered oxide etchant (BOE), electro chemical discharge (ECD) and ultraviolet sensitive adhesives (UVSA). All experiments were the 10 times according to the process conditions. The experiment and research are required the ultraviolet expose, the micro fluid current, the cell control and the measurement of the output voltage Vpp (peak to peak) waveform by scattering angles. The transmitting and receiving of the laser beam was used the single mode optical fiber. The principles of the optical properties are as follows. The red blood cells were injected into the micro channel. The single mode optical fiber was inserting in the guide channel. The He-Ne laser beam was focusing in the single mode optical fiber. The transmission He-Ne laser beam is irradiating to the red blood cells. The manufactured guide channel consists of the four inputs and the four outputs. The red blood cell was allowed with the cylinder pump. The output voltage Vpp waveform of the scattering beam was measured with a photo detector. The receiving angle of the output optical fiber is $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$. The magnitude of the output voltage Vpp waveform was measured in the decrease according to increase of the reception angles. The difference of the output voltage Vpp waveform is due differences of the light transmittance of the red blood cells.

Simultaneous measurements of red blood cell aggregation and blood viscosity in a slit rheometry with light transmission analysis (광 투사법을 이용한 슬릿 점도계에서의 적혈구 응집성 및 점도 측정에 관한 연구)

  • Park, Myung-Su;Ku, Yun-Hee;Shin, Se-Hyun;Suh, Jang-Su
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1678-1681
    • /
    • 2004
  • The light-transmission technique has been applied to a slit rheometer for measuring red blood cell aggregation as well as blood viscosity over a range of shear rates. For measurement of blood viscosity and aggregation, instantaneous pressure and transmit-light intensity are measured with time. Using a precision pressure measurement, one can determine the shear stress and shear rate. In addition, a transmitted light through a blood sample indicates degree of RBC aggregation. With abruptly flowing with high shear rate, RBCs rapidly disaggregate and the intensity of the transmitted light becomes low. When continuously flowing with decreasing shear rate, RBCs tend to re-aggregate and the corresponding transmit-intensity gradually increases with time. The light intensity as a degree of RBC aggregation is plotted against shear rate and compared with blood viscosity. The advantages of this design are dual measurement at a time, simplicity, i.e., ease of operation and no moving parts, low cost, short operating time, and the disposable kit which is contacted with blood sample.

  • PDF

A Genome-wide Association Study of Copy Number Variation in Hematological Parameters in the Korean Population

  • Kim, Ka-Kyung;Cho, Yoon-Shin;Cho, Nam-H.;Shin, Chol;Kim, Jong-Won
    • Genomics & Informatics
    • /
    • v.8 no.3
    • /
    • pp.122-130
    • /
    • 2010
  • Abnormal hematological values are associated with various disorders including cancer and cardiovascular, metabolic, infectious, and immune diseases. We report the copy number variations (CNVs) in clinically relevant hematological parameters, including hemoglobin level, red and white blood cell counts, platelet counts, and red blood cell (RBC) volume. We describe CNVs in several loci associated with these hematological parameters in 8,842 samples from Korean population-based studies. The data that we evaluated included four RBC parameters, one platelet parameter, and one associated with total white blood cell (WBC) count, exceeding the genome-wide significance. We show that CNVs in hematological parameters are associated with some loci, different from previously associated loci reported in single nucleotide polymorphism (SNP) association studies.

Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channel and GMR-SV Device

  • Park, Ji-Soo;Kim, Nu-Ri;Jung, Hyun-Jun;Khajidmaa, Purevdorj;Bolormaa, Munkhbat;Lee, Sang-Suk
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2015.05a
    • /
    • pp.161-163
    • /
    • 2015
  • The micro device, coil, and channel for the biosensor integrated with the GMR-SV device based on the antiferromagnetic IrMn layer was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ passed on the micro channel, the movement of RBC + ${\mu}Beads$ is controlled by the electrical AC input signal. The RBC + ${\mu}Beads$ having a micro-magnetic field captured above the GMR-SV device is changed as the output signals for detection status. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property as the membrane's deformation of RBC coupled to magnetic beads.

  • PDF

Interaction of Calcium with Suramin in Human Red Cell Preparation (사람적혈구막에서의 Calcium과 Suramin의 상호작용)

  • Kang, Bok-Soon;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 1976
  • The trypanocidal drug suramin, an impermeant polyanion, has been shown to be a powerful inhibitor of the calcium uptake and calcium-stimulated ATPase activity of sarcoplasmic reticulum (Fortes et al., 1974). In view of this finding, an attempt was made to investigate the effect of suramin on $Ca^{++}$ transport in resealed red cells and on $Ca^{++}$-activated ATPase in red blood cell membrane fragments (RBCMF). The results obtained are summarized as follows. 1. $Ca^{++}$ outflux from the resealed RBC was inhibited by suramin and the inhibitory action of suramin is proportional to the concentration of drug added inside the RBC preparation. When suramin is added both inside and outside the RBC preparation simultaneously, the magnitude of the inhibitory effect was more pronounced, suggesting that suramin inhibits both active $Ca^{++}-^{45}Ca$ exchange diffusion across the RBC membrane. 2. Suramin inhibits the $Ca^{++}$-activated ATPase of the RBCMF and the effect of inhibition by the drug was also concentration dependent. From the above results, it may be concluded that suramin inhibits $Ca^{++}$ transport across RBC membrane by inhibiting $Ca^{++}$-activated ATPase activity which has been known to be linked with active $Ca^{++}$ transport.

  • PDF