• Title/Summary/Keyword: RBC system

Search Result 112, Processing Time 0.025 seconds

Treatment of Dairy Wastewater by the Combination of RBC and tapered Aeration (RBC와 점감포기조의 복합구성에 따른 유가공폐수 처리에 관한 연구)

  • Lee, Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1733-1738
    • /
    • 2008
  • The treatment efficiency of rotating biological contactors (RBCs) for the high strength of dairy wastewater was investigated. Two different systems were conducted composing of a single RBC with tapered aeration reactors for the system A and a sequential RBCs following tapered aeration reactors for the system B. Experiments using dairy wastewater were conducted for 50 days period of time, in which hydraulic rates were maintained at the constant ratios of 346L per day and variable BOD concentrations were at the range from 1,358mg/L to 829mg/L, the $COD_{cr}$, concentration of the range were from 2,384mg/L to 1,329mg/L, the range of T-N concentrations was from 66mg/L to 38mg/L, and 50% of internal recycle and 50% of sludge return were performed. Results indicated that the removal efficiencies of the system B were higher than those of the system A. The removal efficiencies of system A for the BOD, $COD_{cr}$, T-N and T-P were 97.8%, 96.7%, 87.2% and 82%, respectively. The removal efficiencies of system B for the BOD, $COD_{cr}$, T-N and T-P were as of 98.5%, 98.5%, 91.3% and 89%.

Effects of Rotational Speed and Hydraulic Residence Time on the Ammonia Removal of a Rotating Biological Contactor (RBC) (회전속도와 수리학적 체류시간이 회전원판식(Rotating Biological Contactor;RBC) 여과조의 암모니아 제거에 미치는 영향)

  • 오승용;조재윤;김종만
    • Journal of Aquaculture
    • /
    • v.16 no.3
    • /
    • pp.142-150
    • /
    • 2003
  • Performance of a biological filter, the rotating biological contactor (RBC), is affected by rotational speed and hydraulic residence time (HRT). A RBC with a disc diameter of 62 cm, total surface area of 48.28 $m^2$, volume of 0.34 ㎥, and submergence ratio of 35.4% was tested for the combinations of five rotational speeds (1, 2, 3, 4 & 5 rpm) and three HRT (0.5, 1.0 & 2.0 hr) to find out the maximum removal efficiencies of total ammonia nitrogen (TAN) and nitrite nitrogen of a simulated recirculating aquaculture system. Ammonia loading rate in the system was 25 g of TAN/ ㎥. day. Removal efficiencies were checked when TAN concentrations in the system stabilized for 3 days in each treatment. The concentration of TAN in the system decreased with increasing rotational speed of the RBC up to 4 rpm in all HRT (P<0.05). At the rotational speed of 5 rpm, the efficiencies decreased in all HRT (P<0.05). When the rotational speeds were 1, 2, 3, 4, and 5 rpm, TAN concentrations in the system were 1.35, 0.94, 0.69, 0.66, and 0.76 mg/L at the 0.5 hr HRT, 2.86, 1.18, 0.96, 0.87, and 1.11 mg/L at the 1.0 hr HRT, and 5.30, 2.44, 1.99, 1.77, and 2.01 mg/L at the 2.0 hr HRT, respectively. The TAN removal efficiencies of the RBC at the rotational speeds of 1, 2, 3, 4, and 5 rpm were 32.9, 49.5, 65.1, 72.9, and 62.9% in 0.5 hr HRT,33.1, 74.1, 87.1, 95.8, and 78.5% in 1.0 hr HRT, and 35.5, 76.7, 89.6, 97.0, and 85.5% in 2.0 hr HRT, respectively. TAN removal efficiency of RBC per pass increased with increasing HRT. However, TAN concentration in the system also increased. The best operating condition among the treatments was obtained at the treatment of 0.5 hr HRT and 4 rpm (P<0.05). The TAN concentration was 0.66 mg/L. Concentrations of nitrite nitrogen (NO$_2$$^{[-10]}$ -N) in the system decreased with increasing rotational speed in all HRT while that in the system increased with increasing HRT in all rotational speeds. The ranges of NO$_2$$^{[-10]}$ -N concentrations at HRT of 0.5, 1.0, and 2.0 hr in the system were 0.26~0.32, 0.31~0.56, and 0.43~l.45 mg/L, respectively. The ranges of daily removal rates of TAN in this system were 20.03~23.0 g TAN/㎥ㆍday and those of nitrite nitrogen were 19.65~30.25 g NO$_2$$^{[-10]}$ -N/㎥ㆍday.

Ammonia removal rate on ammonia loading rates in seawater filtering system using rotating biological contactor (RBC) (회전원판을 이용한 해수 순환여과 시스템에서 암모니아 부하율에 따른 암모니아 제거율)

  • SON Maeng Hyun;JEON Im Gi;CHO Kee Chae;KIM Kang Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.4
    • /
    • pp.367-372
    • /
    • 2000
  • A series of experiment was conducted to investigate the relationship between ammoia removal rate and ammonia loading rates in seawater filtering system using rotating biological contactor (RBC). In this experiment, RBC system was consisted of rotating polyvinyl film disks, which provided $12 m^2$ of total effective surface area in $0.075 m^3$ of volume. $NH_4Cl$ was added by $10{\~}150 g$ as a ammonia nitrogen source to determine ammonia removal rate in RBC system. Relationship between time required for ammonia removal (y: hour) and nitrogen inputted ($x: NH_4-N mg/l$) in RBC system was as followed: $y=3.51+7.76 lnx (r^2=0.936)$. At ammonia concentration $2 mg/l$, it took 10 hour for removal of ammonia in the RBC system. However, at ammonia concentration of $5 and 16.5 mg/l$, it took 16 and 27 hours, respectively. There was a decreasing tencency of an increasing ammonia in the rearing water. Finally, the ammonia removal rate in the RBC system increased with the rise of total ammonia concentration up to $16.5 mg/l$.

  • PDF

Studies on the RBC Alloimmunization after Blood Transfusions

  • Kim Jae-Woo;Kim We-Jong
    • Biomedical Science Letters
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2006
  • Alloimmunization to red blood cell (RBC) antigens may cause a delayed hemolytic transfusion reactions (DHTR) and a delayed serologic transfusion reactions (DSTR). In the present study, the frequency of alloimmunization and its clinical significance were evaluated. Also, transfusions were correlated with antibody formation. Alloimmunization rate was 0.63%. Alloimmunization rate in multiple transfused patients was 24.5%. The most common clinically significant alloantibodies of alloimmunized patients were found to be Rh antibodies (52.6%). Nine patients out of 38 (23.7%) became undetectable after the first detection. To be positive at antibody screening test after RBC transfusion was mean transfused numbers: 3.7 units, mean transfused periods: 56 days, mean transfused frequencies: 1.7 times. The results from antibody specificity and RBC transfusions were comparatively analyzed and it shows that Rh system antibodies were longer than other antibodies (P<0.05). In case of disease group, malignant diseases was longer than other diseases (P<0.05). In order to prevent the formation of RBC alloimmunization, irregular antibody screening tests were performed at propriety intervals in multiple transfused patients.

  • PDF

Development of a Rotating Biological Contactor(RBC) Process for the Advanced Wastewater Treatment (회전원판(回轉圓板) 생물막(生物膜) 공법(工法)을 이용한 하(下)·폐수(廢水)의 고도처리(高度處理) 공정(工程) 개발(開發))

  • Kim, Eung Ho;Park, Jae Lo;Yoon, Jung Ro
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.2
    • /
    • pp.1-11
    • /
    • 1994
  • This study was conducted to develop a new RBC process available for the effective removal of organic matters and nitrogen in sewage. The RBC process for the oxidation organic compounds and nitrification was designed to occur at the 1st-stage and next-stage RBC respectively. Then nitrified water was recycled to the denitrifying RBC located at the lower part of the 1st-stage RBC. Some results were summarized as follows. 1. The loading limitation was represented as $60g{\cdot}COD/gm^2/day$ in experiment of simultaneous removal of organic matter and nitrogen. The maxmum COD % removal was 85% at the load $35g{\cdot}COD/m^2/day$. 2. The $NO_3-N$ % removal was approximately 80% at the load $60g{\cdot}COD/m^2/day$ and the maximum $NO_3-N$ remaval rate was $3.9g{\cdot}COD/m^2/day$ and the overall C/N ratio of 11.0 as required to achive 80% of $NO_3-N$% removal. 3.$NO_3-N$ removal rate was rapidly decreased above the load $7g{\cdot}NH_4{^+}-N/m^2/day$ and the maximum $NO_3-N$ removal rate was $3.7g{\cdot}NO_3-N/m^2/day$. 4. Irrespective of the recycle ratio, the COD % removal at the system of 2-stage RBC unit was nearly constant as 89% while the maximum one in the 1st-stage unit was 77% in the case of 50% recycle. 5. The maximum COD % removal in the 3-stage RBC system was 93% while 1st-stage one being 80%, under the $NH_4{^+}-N$ load of $7.4g/m^2{\cdot}d$. Also maximum percentage of nitrification and denitrification was 69% and 41% respectively, under the same $NH_4{^+}-N$ load.

  • PDF

Characteristics of Wastewater Treatment in Applying RBC Modified Dephanox Process (회전원판법을 적용한 Modified Dephanox 공정의 하수처리특성)

  • Kang, Min-Koo;Kim, Keum-Yong;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.477-486
    • /
    • 2010
  • This study was performed with the object in which it improves the nitrification by using RBC, that is one of the biological waste water treatment process. By applying the Modified Dephanox process to RBC in this research in order to evaluate the improvement of the nitrification by RBC a research was conducted. There is the most conspicuous feature of the process of using RBC. it is that the nitrification can be smoothly performed even if the suspended solid of the high concentration as the interference factor in the nitrification tank is flowed in. Moreover, as a result of experiment, TCOD removal efficiency of the process showed up more than about 90%. when influent TCOD loading rate was 0.04~0.1 kg / $day{\cdot}m^3$. and T-N removal efficiency is high at about 75% in spite of the process operating of the laboratory scale was observed. Also, As increasing influent ${PO_4}^{3-}$-P, T-P loading rate, ${PO_4}^{3-}$-P, T-P removal efficiency was increased. Finally, it was elucidated that the utilization of RBC in external nitrification system resulted in not only high nitrification performance but also stable system operation by minimizing inhibitory effect of overflowed suspended solid (SS).

High Strength Slaughter Wastewater Treatment in a Novel Combined System of Hybrid-Rotating Biological Contactor and Biological Aerated Filter (Hybrid-RBC와 BAF의 조합공정을 이용한 고농도 도축폐수의 처리 특성)

  • Jung, Chan-Il;Ahn, Jo-Hwan;Bae, Woo-Keun;Kim, Seung-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.77-84
    • /
    • 2011
  • This study was conducted to develop a novel combined system of a hybrid rotating biological contactor (RBC) process that was composed of an attached- and suspended- biomass reactor, followed by a settler and a biological aerated filter (BAF) column to treat a high strength slaughter wastewater. Long term influences of organic and nitrogen loading rates were investigated to see how the combined system worked in terms of the removal efficiency. A synthetic wastewater containing a pork cutlet steak source (commercially available) and swine blood was used to feed the combined system. The hybrid RBC process showed excellent removals: about 95% for soluble COD and 85% for ammonium nitrogen. However, the unsettled solids seriously deteriorated the removal efficiency of total COD (TCOD) and total nitrogen (TN) in the RBC process. A significant fraction of the TCOD and suspended solids (SS) was further removed in the BAF column although the effluent quality was still unsatisfactory, giving TCOD 300 mg/L, SS 180 mg/L and TN 59 mg/L. An addition of polyaluminium chloride into the RBC effluent improved the performance of the settler and BAF, producing an excellent quality of final effluent; TCOD 16.5 mg/L, SS 0 mg/L, TN 55.5 mg/L, TP 1.3 mg/L. Therefore, it was confirmed that the combined system of hybrid RBC and BAF could treat a high strength slaughter wastewater excellently.

Treatment of Recirculating Aquacultural Water by an Airlift Bioreactor Containing Immobilized Microorganisms (고정화 미생물을 이용한 공기 부상식 생물반응기에 의한 순환 여과식 양어장의 순환수 처리)

  • SUH Kuen-Hack;KIM Byong-Jin;KIM Sung-Koo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.6
    • /
    • pp.661-668
    • /
    • 2003
  • Performance of an airlift bioreactor (ABR) containing the immobilized microorganisms was evaluated in an integrated pilot scale recirculating aquaculture system stocked with Nile tilapia (Oreochromis niloticus) at an initial rearing density of $5\%$ and compared to a rotating biological contactor (RBC) for 40 days. The TAN concentration of rearing tank for ABR and RBC were maintained at $0.4\;g/m^3$ and $0.5\;g/m^3,$ respectively, The nitrite nitrogen was completely removed by the ABR. The ABR's aeration was more stable than the RBC's. On the whole, the feasibility of ABR as an aquacultural water treatment unit was recognized.

Microchip-based cell aggregometer using stirring-disaggregation mechanism

  • Shin, Se-Hyun;Yang, Yi-Jie;Suh, Jang-Soo
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.3
    • /
    • pp.109-115
    • /
    • 2007
  • A new microchip-based aggregometer that uses a stirring-aided disaggregation mechanism in a microchip was developed to measure red blood cell (RBC) aggregation in blood and RBC suspensions. Conventional methods of RBC disaggregation, such as the rotational Couette system, were replaced with a newly designed stirring-induced disaggregation mechanism. Using a stirrer in a microchip, the aggregated RBCs stored in a microchip can be easily disaggregated. With an abrupt halt of the stirring, the backscattered light intensity can be measured in a microchip with respect to time. The time recording of the backscattered light intensity (syllectogram) shows an exponential decreasing curve representing the RBC aggregation. By analyzing the syllectogram, aggregation indices such as AI and M were determined. The results showed excellent agreement with LORCA. The essential feature of this design is the incorporation of a disposable microchip and the stirring-induced disaggregation mechanism.

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF