Abstract
Performance of an airlift bioreactor (ABR) containing the immobilized microorganisms was evaluated in an integrated pilot scale recirculating aquaculture system stocked with Nile tilapia (Oreochromis niloticus) at an initial rearing density of $5\%$ and compared to a rotating biological contactor (RBC) for 40 days. The TAN concentration of rearing tank for ABR and RBC were maintained at $0.4\;g/m^3$ and $0.5\;g/m^3,$ respectively, The nitrite nitrogen was completely removed by the ABR. The ABR's aeration was more stable than the RBC's. On the whole, the feasibility of ABR as an aquacultural water treatment unit was recognized.
Keywords
Airlift bioreactor; Immobilized microorganisms; RBC; Recirculating aquaculture system; Oreochromis niloticus;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Sharma B. and R.C. Ahlert. 1977. Nitrification and nitrogen removal. Water Res., 11, 897-925   DOI   ScienceOn
2 Speece, R.E. 1973. Trout metabolism characteristics and the rational design of nitrification facilities for water reuse in hatcheries. Trans. Ame. Fish. Soc., 102, 323-334   DOI
3 Suh, K.H., Y.H. Kim and B.J. Kim. 1999. Nitrifier consortium immobilized bioreactor for $NH_3$-N removal in synthetic aquaculture water. HWAHAK-KONGHAK, 37(3), 487-493. (in Korean)
4 Wickins, J.F. 1980. Water quality requirements for intensive aquaculture. In: A Review, Symposium on New Developments in the Utilization of Heated Effluents and Recirculation Systems or Intensive Aquaculture. EIFAC, llth Session, Stavanger, Norway, pp. 245-252
5 APHA, AWWA and WEF. 1992. Standard methods for the examination of water and wastewater, 18th Ed., EPS Group, pp. 4382
6 Colt, J. and D.A. Armstrong. 1981. Nitrogen toxicity to crustacean, fish and mollusks. Bio-Engineering Symposium for Fish Culture. FCS Publ., 1, 34-47
7 Hashimoto, S. and K. Furukawa. 1987. Immobilization of activated sludge by PVA-boric acid method. Biotech. Bioeng., 30, 52-59   DOI   ScienceOn
8 Jobling, H.H. 1994. Fish Bioenergetics. Chapman and Hall, London, pp. 120
9 Kim, S.K., J.K. Seo, J.S. Lee, I.S. Kong and K.H. Suh. 1997. Removal of total ammonia-nitrogen (TAN) using immobilized nitrifier consortium J. Kor. Fish. Soc., 30(5), 816-822
10 Liao, P.B. and R.D. Mayo. 1974. Intensified fish culture combine water reconditioning with pollution abatement. Aquaculture, 3, 61-85   DOI   ScienceOn
11 Libey, G.S. 1992. Maximum nitrification with rotating biological contactors (RBCs). In: Proceedings of the Workshop on Design of High Density Recirculating Aquaculture Systems. Louisiana State Univ. Baton Rouge, Louisiana, pp. 40-48
12 Muir, J.F. 1982. Recirculated system in aquaculture. In: Recent Advances in Aquaculture, Vol. 1. Croom Helm and Westview Press, London, pp. 253-268
13 Meade, J.W. 1985. Allowable ammonia for fish culture. Prog. Fish-Culturist, 47, 135-148   DOI
14 Miller, G.E. and G.S. Libey. 1984. Evaluation of a trickling biofilter in a recirculating aquaculture system containing channel catfish. Aquacult. Eng., 3, 39-57   DOI   ScienceOn