• Title/Summary/Keyword: R744

Search Result 120, Processing Time 0.029 seconds

Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region (초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.

A Propose of Design Parameters for the Max. Speed of 250 km/h of Overhead Rigid Conductor System (250 km/h급 강체전차선로 설계파라미터 제시)

  • Lee, Kiwon;Cho, Yong Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.740-744
    • /
    • 2017
  • Overhead Line is divided by two systems which are OCS (Overhead Catenary Line) and R-Bar (Overhead Rigid Conductor system). R-Bar has an advantage of maintenance and economic aspect comparing with OCS. R-Bar in Korea has developed for the max. speed of 120km/h, but it is evaluated up to the max. speed of 250 km/h in Europe. There are lots of mountains and underground sections in korea, it is really necessary to develop the R-Bar for a high-speed line. In the study, design parameters for the max. speed of 250 km/h of R-Bar was proposed. A bracket space, stiffness, and especially an installation tolerance of contact wire height at a bracket were considered as a parameter, and a dynamic behavior between a contact wire and pantograph was predicted by evaluated FEM simulation tool. The installation tolerance and bracket space are more important for the high-speed system. The proposed parameters was decided very conservative. Because the aerodynamic characteristics of a pantograph in tunnel is more severe than an open route and the simulation tool is not considered the such kind of aerodynamic characteristics.

Surface displacements due to tunneling in granular soils in presence and absence of geosynthetic layer under footings

  • Rebello, Nalini E.;Shivashankar, R.;Sastry, Vedala R.
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.739-744
    • /
    • 2018
  • This paper presents the results of numerical modeling studies on the effect of displacements of tunneling in granular soils. Presence of building loads is considered, to find displacement generated at the surface on tunnel. Effect of varying eccentricities of building is simulated, to find influence of building on vertical and horizontal displacement. Studies were carried out in two cases of with and without a geosynthetic layer installed at the bottom of the footing. Results of analysis revealed, the presence of geosynthetic layer under footing, with building placed on centre line, reduced the surface displacements compared to displacement generated without geosynthetic layer. Presence of geosynthetic layer under footing had a dominant effect in reducing displacements in high storey structures. However, when the building was shifted to greater eccentricities from centre line, presence of geosynthetic layer, led to insignificant reduction of displacements on the centre line at the surface.

Crystal Structure Analysis of N,N'-bis(3-chloro-2-methylsalicylidene)-1,4-butanediamine

  • Sharmila, P.;Rajesh, R.;Venkatesan, R.;Ganapathy, Jagadeesan;Aravindhan, S.
    • Journal of Integrative Natural Science
    • /
    • v.9 no.4
    • /
    • pp.255-260
    • /
    • 2016
  • The crystal structure of the saliciline derivatives N,N'-bis(3-chloro-2-methylsalicylidene)-1,4-butanediamine ($C_{20}H_{22}Cl_2N_2O_2$) has been determined from single crystal X-ray diffraction data. In the title compound crystallizes in the triclinic space group $P{\bar{i}}$ with unit cell dimension $a=4.6085(3){\AA}$, $b=5.9747(3){\AA}$ and $c=5.9747(3){\AA}$ [${\alpha}=83.889(4)^{\circ}$, ${\beta}=86.744(5)^{\circ}$ and ${\gamma}=82.085(5)^{\circ}$]. The title compound is essentially planar conformation. The compound lies across a crystallographic inversion centre and adopts E configurations with respect to the C-N bonds. The crystal packing of the molecules of compound is stabilized through weak O-H...N intra molecular interactions

Estimation of deep percolation using field moisture observations and HYDRUS-1D modeling in Haean basin (해안분지의 현장 토양수분 관측과 HYDRUS-1D 모델링을 이용한 지하수 함양 추정)

  • Kim, Jeong Jik;Jeon, Woo-Hyun;Lee, Jin-Yong
    • Journal of the Geological Society of Korea
    • /
    • v.54 no.5
    • /
    • pp.545-556
    • /
    • 2018
  • This study was conducted to estimate the deep percolation using numerical modeling and field observation data based on rainfall in Haean basin. Soil moisture sensors were installed to monitoring at 30, 60 and 90 cm depths in four sites (YHS1-4) and automatic weather station was installed to around YHS3. Soil moisture and meteorological data was observed from March 25, 2017 to March 25, 2018 and May 06, 2016 to May 06, 2018, respectively. Numerical analysis was performed from June to August, 2017 using the HYDRUS-1D. Average soil moisture contents were high to generally in YHS3 for 0.300 to $0.334m^3/m^3$ and lowest in YHS1 for 0.129 to $0.265m^3/m^3$ during the soil moisture monitoring period. The results of soil moisture flow modeling showed that field observations and modeling values were similar but the peak values were larger in the modeling result. Correlation analysis between observation and modeling data showed that r, $r^2$ and RMSE were 0.88, 0.77, and 0.0096, respectively. This show high correlation and low error rate. The total deep percolation was 744.2 mm during the period of modelling at 500 cm depth. This showed that 61.3% of the precipitation amount (1,214 mm) was recharged in 2017. Deep percolation amount was high in the study area. This study is expected to provide basic data for the estimation of groundwater recharge through unsaturated zone.

Evaporative Heat Transfer Characteristics of Carbon Dioxide in a Horizontal Tube (수평관내 이산화탄소의 증발 열전달 특성)

  • Son Chang-Hyo;Lee Dong-Gun;Kim Young-Lyoul;Oh Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1134-1139
    • /
    • 2004
  • The evaporative heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 7.75 mm. The experiments were conducted at mass flux of 200 to 500 kg/m$^2$s, saturation temperature of -5 to 5$^{\circ}C$, and heat flux of 10 to 40kW/m$^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much, and the effect of mass flux on evaporative heat transfer of $CO_2$ is much smaller than that of refrigerant R-22 and R-134a. In comparison with test results and existing correlations, correlations failed to predict the evaporative heat transfer coefficient of $CO_2$, therefore, it is necessary to develope reliable and accurate predictions determining the evaporative heat transfer coefficient of $CO_2$ in a horizontal tube.

Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation

  • Kim, Yeon Soo;Kim, Se Hyung;Ryu, Hwa Sung;Han, Joon Koo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1077-1088
    • /
    • 2018
  • Objective: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. Materials and Methods: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed DECTE images by consensus for qualitative and quantitative CT features. CT attenuation and iodine concentration for the diseased bowel were also measured. Univariate statistical tests were used to evaluate whether there was a significant difference in CTE features between remission and active groups, on the basis of the CDAI score. Pearson's correlation test and multiple linear regression analyses were used to assess the correlation between quantitative CT parameters and CDAI. For external validation, an additional 33 consecutive patients were recruited. The correlation and concordance rate were calculated between real and estimated CDAI. Results: There were significant differences between remission and active groups in the bowel enhancement pattern, subjective degree of enhancement, mesenteric fat infiltration, comb sign, and obstruction (p < 0.05). Significant correlations were found between CDAI and quantitative CT parameters, including number of lesions (correlation coefficient, r = 0.573), bowel wall thickness (r = 0.477), iodine concentration (r = 0.744), and relative degree of enhancement (r = 0.541; p < 0.05). Iodine concentration remained the sole independent variable associated with CDAI in multivariate analysis (p = 0.001). The linear regression equation for CDAI (y) and iodine concentration (x) was y = 53.549x + 55.111. For validation patients, a significant correlation (r = 0.925; p < 0.001) and high concordance rate (87.9%, 29/33) were observed between real and estimated CDAIs. Conclusion: Iodine concentration, measured on detector-based DECTE, represents a convenient and reproducible biomarker to monitor disease activity in CD.

Analysis on the Measurement and Shape Classification of the Bead of Korean Male Children for the Headwear Sizing System (초등학교 남자아동의 모자 제작을 위한 머리부위 측정 및 형태 분석)

  • Kim Son Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.5 s.142
    • /
    • pp.737-744
    • /
    • 2005
  • This study was aimed to provide the measurement data and shape classification of the head of the Korean male children for the headwear sizing systems. Five hundred twenty male children, aged nine to twelve years, participated f3r this study. The 17 regions on the head and height, weight of the subjects were directly measured by the expert experimenters. Factor analysis, cluster analysis, GLM analysis and Tukey HSD test were performed using these data. Through factor analysis, low factors were extracted upon factor scores and those factors comprised $69.76\%$ for the total variances. Three clusters as their head shape were categorized using four factor scores by cluster analysis. Type 1 was characterized by the widest width and Bitragion arc, shortest head length. Type 2 had the longest head length and the widest side width and the highest head length and head circumference. Type 3 was characterized by the smallest head circumstance, head width and side width, and medium head length.

SOAP-based Distributed Processing Scheduling Framework: pyBubble (SOAP기반의 분산처리 스케줄링 프레임웍: pyBubble)

  • ;;;R.S.Ramakrishna
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.742-744
    • /
    • 2004
  • 본 논문은 웹 서비스 프로토콜인 SOAP기반의 병렬처리 프레임웍인 pyBubble의 설계와 구현에 관한 것이다. 그리드 어플리케이션 프로그래밍의 어려움을 덜기 위해 그리드 미들웨어들로부터의 복잡성에 투명성을 제공하는 것을 본 논문의 목표로 한다. 이는 RPC스타일의 프로그래밍 인터페이스를 지원하면서 파이썬 스크립트 언어의 이식성과 확장성을 통해 기존 병렬처리 어플리케이션의 그리드화와 다양한 자원 스케줄링을 연구 할 수 있도록 하는 스케줄링 프레임웍이 주요 기능적 요소이다. 병렬처리를 위해 비동기 SOAP과 이를 이용한 Task-Farming과 DAG기반의 스케줄링의 지원함으로써 고성능의 그리드 계산환경을 제공하고자 한다.

  • PDF

Video Watermarking Based on Wavelet Magnitude Modulus Subband

  • Byun, Jin-Kyung;Moon, Young-Deuk;Lee, Suk-Hwan;Kwon, Seong-Geun;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.6
    • /
    • pp.737-744
    • /
    • 2007
  • This paper proposes the blind watermarking algorithm for digital video based on magnitude modulus subband in wavelet transform domain. After transforming each of frames into wavelet domain, the proposed algorithm divides LH, HL, and HH subbands of 2-level into $3{\times}3$ blocks and calculates average magnitude modulus of all blocks. Then the watermark bit is embedded into a target magnitude modulus comparing with an average magnitude modulus within a block. Experimental results were confirmed that the proposed algorithm has the good robustness against MPEG and frame attacks than the conventional algorithm.

  • PDF