• Title/Summary/Keyword: R410a

Search Result 305, Processing Time 0.024 seconds

An experimental study on the dynamic characteristics of a residential air-conditioner with a R22 alternative refrigerant (R22 대체냉매 에어컨의 동적 특성에 대한 실험적 연구)

  • Kim, Man-Hoe
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.408-415
    • /
    • 1998
  • This study presents experimental results on the shut-down and start-up characteristics of a residential split-system air-conditioner with capillary tube, using R410A as a R22 alternative refrigerant. During shut-down, the transient characteristics are evaluated by measuring the high side and low side pressures and temperatures of the system. The dynamic behavior of the system after start-up is also investigated at the high temperature cooling test condition. All experiments are performed in psychrometric calorimeter. The cooling capacity, power consumption, dehumidification capacity and cycle characteristics after start-up are analyzed.

Constitutive Activating Eel Luteinizing Hormone Receptors Induce Constitutively Signal Transduction and Inactivating Mutants Impair Biological Activity

  • Byambaragchaa, Munkhzaya;Choi, Seung-Hee;Kim, Dong-Wan;Min, Kwan-Sik
    • Development and Reproduction
    • /
    • v.25 no.3
    • /
    • pp.133-143
    • /
    • 2021
  • In contrast to the human lutropin receptor (hLHR) and rat LHR (rLHR), very few naturally occurring mutants in other mammalian species have been identified. The present study aimed to delineate the mechanism of signal transduction by three constitutively activating mutants (designated M410T, L469R, and D590Y) and two inactivating mutants (D383N and Y546F) of the eel LHR, known to be naturally occurring in human LHR transmembrane domains. The mutants were constructed and measured cyclic adenosine monophosphate (cAMP) accumulation via homogeneous time-resolved fluorescence assays in Chinese hamster ovary (CHO)-K1 cells. The activating mutant cells expressing eel LHR-M410T, L469R, and D590Y exhibited a 4.0-, 19.1-, and 7.8-fold increase in basal cAMP response without agonist treatment, respectively. However, inactivating mutant cells expressing D417N and Y558F did not completely impaired signal transduction. Specifically, signal transduction in the cells expressing activating mutant L469R was not occurred with a further ligand stimulation, showing that the maximal response exhibited approximately 53% of those of wild type receptor. Our results suggested that the constitutively activating mutants of the eel LHR consistently occurred without agonist treatment. These results provide important information of LHR function in fish and regulation with regard to mutations of highly conserved amino acids in glycoprotein hormone receptors.

The Performance Analysis of Sea Water Heat Pump applied Low GWP Refrigerants (Low GWP 냉매를 적용한 해수열 히트펌프의 성능해석)

  • Lim, Seung-Taek;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.92-97
    • /
    • 2016
  • In this study, the seawater Heat Pump System using seawater with temperature of annual domestic conditions ($0^{\circ}C$ to $25^{\circ}C$) is designed in order to compare its performance against the Heat Pump using unused heat of seawater. As a potential replacement for current refrigerants that exacerbate global warming and ozone delpetion, a Low GWP refrigerant's performance is analyzed. The basic water to water Heat Pump system is chosen and three commercial refrigerants - R134a, R410a, R32 - are used to compare against new Low GWP refrigerant R1234ze. When seawater with temperature of $25^{\circ}C$ is used, the performance change showed maximal increase in COP, 38.3%. low GWP refrigerant R1234ze, showed great performance characteristics reach to 5.242 and Existing commercial refrigerant, R134a showed only less than 0.03 performance difference against R1234ze. The study confirms notable performance of R1234ze refrigerant through simulation as environmentally friendly refrigerant for domestic seawater Heat Pump.

Dynamic Modeling and Simulation of a Hybrid Heat Pump (하이브리드 열펌프 동적 모델링 및 시뮬레이션)

  • Shin, Younggy;Kim, Jae Hyun;Yoo, Byeong Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.406-412
    • /
    • 2013
  • A hybrid heat pump is under development with the goal of utilizing 120% of primary energy resources. A plate heat exchanger is added between the compressor and air-cooled condenser of an ordinary heat pump to heat water. For successful operation of the heat pump, it is necessary to develop a control algorithm under various operating conditions. As a virtual test bed for that purpose, a dynamic model has been developed, to simulate its dynamic behavior. It was modeled in transient one-dimensions, with varying phase lengths considered. The model was implemented in Matlab and Simulink. Simulation results were effectively applied to design a control algorithm. They also provided physical insight into how to design and operate the system.

Effect of Flow Direction on Two-Phase Flow Distribution of Refrigerants at a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.717-727
    • /
    • 2006
  • The present study experimentally investigated the effect of flow direction and other flow parameters on two-phase flow distribution of refrigerants at a T-junction, and also suggested a prediction model for refrigerant in a T-junction by modifying previous model for air-water flow. R-22, R-134a, and R-410A were used as test refrigerants. As geometric parameters, the direction of the inlet or branch tube and the tube diameter ratio of branch to inlet tube were chosen. The measured data were compared with the values predicted by the models developed for air-water or steam-water mixture in the literature. We propose a modified model for application to the reduced T-junction and vertical tube orientation. Among the geometric parameters, the branch tube direction showed the biggest sensitivity to the mass flow rate ratio for the gas phase, while the inlet quality showed the biggest sensitivity to the mass flow rate ratio among the inlet flow parameters.

Effect of Parameters on the Two-Phase Flow Distribution Characteristics of Refrigerants in a Horizontal T-Junction (수평 T형 분지관 내 냉매 이상유동 분배특성에 미치는 변수들의 영향)

  • Tae Sang-Jin;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.31-37
    • /
    • 2006
  • The present study has been experimentally investigated the effect of geometric and operating parameters on the two-phase flow distribution of refrigerants in a horizontal T-junction. The operating parameters were the kind of refrigerants (R-22, R- l34a, and R-410A), saturated temperature, and the inlet mass flux and quality. The geometric parameters were the tube diameter and the tube diameter ratio. The measured data of refrigerants were compared with the values predicted using the models developed by several researchers for air/water or steani/water two-phase flow. Among the operating parameters, the inlet Quality was the most sensitive to the mass flow rate ratio. Between the geometric parameters, the tube diameter ratio was more sensitive than tube diameter.

Changs of Vitamin A Concentration, Secretion and Ingake of Infants in Transitional Milk during the Lactation (수유초기 이행유중 비타민 A의 함량, 분비량 및 영야의 섭취량의 변화)

  • 이정실
    • Journal of Nutrition and Health
    • /
    • v.28 no.9
    • /
    • pp.855-861
    • /
    • 1995
  • The longitudinal change of vitamin A concentration and secretion in transitional milk of 32 Korean lactating wormen and vitamin A intake of infants were studied 7, 10 and 15 days postpartum. Retinol concentration of the milk averaged 93.6$\pm$47.1, 80.1$\pm$41.6 and 66.7$\pm$33.5$\mu\textrm{g}$/100ml at 7, 10 and 15 days postpartum respectively and showed decreasing trend in total mothers. $\beta$-carotene concentration showed similar decreasing trend averaged 13.4$\pm$10.6, 8.2$\pm$4.6 and 5.3$\pm$3.4$\mu\textrm{g}$/100ml respectively. Vitamin A concentration decreased with the respective amount of 94.9$\pm$47.1, 80.5$\pm$41.5 and 67.3$\pm$33.0 R.E../100ml during the lactation. The average vitamin A secretion in the milk of all mothers appeared 410.0 R.E/day. Vitamin A secretion of multiparae (450.1 R.E./100ml) appeared not significantly higher than those of primiparae(370.0 R.E./100ml). The average vitamin A intake of infants in the milk averaged 333.7 R.E./day and was 95.3% of RDA for infants. Vitamin A intake per body weight of infants in the milk averaged 110.6, 91.9 and 79.2 R.E./kg/day respectively.

  • PDF

일본의 $CO_2$ 냉매를 이용한 열펌프급탕기 개발 동향

  • 김만회
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.7
    • /
    • pp.65-70
    • /
    • 2002
  • 지구의 오존층을 보호하기 위한 몬트리올 의정서가 1987년 채택된 이후 오존층 파괴물질의 사용이 점차 감소되고 있다. 선진국의 경우 1995년 말부터 CFC냉매의 생산을 전폐하였고, HCFC냉매의 경우는 2020년 전폐를 목표로 대체냉매를 이용한 응용 기술개발 및 제품 생산이 진행되고 있다. 가정용 냉장고 및 차량용 에어컨에는 R-12의 대체냉매로 R-134a가 도입되었으며, 유럽을 중심으로 냉장고에는 HC계 냉매인 R-600a도 대체냉매로 사용되고 있다. 가정용 에어컨에는 혼합냉매인 R-407c 와 R-410a가 R-22 냉매를 대체하여 적용되고 있다. 그러나 현재, CFC및 HCFC 대체 냉매로 많이 사용되고 있는 HFC계 냉매도 지구 온난화 지수가 대단히 큰 문제를 가지고 있다. 1997년 채택된 교토의 정서에는 HFC계 냉매가 온실효과가 가스 배출규제물질에 포함되어 있다. 이에 따라서 오존층의 파괴지수가 영이고 지구온난화지수도 거의 없는 자연냉매가 주목을 받게 되었으며, 자연 냉매의 하나인 이산화탄소 ($CO_2$R744) 냉매의 응용기술 및 제품개발 연구가 선진국을 중심으로 폭넓게 진행되고 잇다. 본고에서는 $CO_2$냉매의 일반적인 특성을 간단히 소개하고 일본에서 진행되고 있는 $CO_2$냉매를 적용한 급탕시스템의 제품개발 및 시장현황에 대해서 기술하기로 한다.

  • PDF

Performance Comparison of Two-stage Compression Refrigeration System Using R404A (R410A용 2단 압축 1단 팽창 냉동시스템의 성능 분석)

  • Yoon, Jung-In;Choi, Kwang-Hwan;Son, Chang-Hyo;Jo, Hwan
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.57-62
    • /
    • 2014
  • This paper present the performance characteristics of R404A two-stage compression refrigeration system. The operating parameters considered in this study include evaporating and condensing temperature, subcooling and superheating degree, compressor efficiency. The main results were summarized as follows: The COP of two-stage compression refrigeration system using R404A has an effect on the variation of evaporation temperature, condensation temperature, subcooling degree and compressor efficiency, but not an effect on the superheating degree. R404A two-stage compression refrigeration system is unstable because COP of this system is significantly changed when evaporating temperature and compressor efficiency decreased. In particular, when compressor efficiency decreased, COP is significantly decreased. This is inefficient for long-term use.

A study on the Simultaneous Determination of Chlorpyrifos and Fluvalinate by HPLC (HPLC에 의한 살충제의 동시분리 정량에 관한 연구 -Chlorpyrifos와 Fluvalinate에 대하여-)

  • 고종명;권문주;이창근;유덕열;허흥덕
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.1
    • /
    • pp.79-86
    • /
    • 1992
  • Rapid determination of chlorpyrifos and fluvalinate in mixed insecticide was established by using high performance liquid chromatography. Result were as follows : 1. On Lichrosorb${\circledR}$ RP-8(10 ${\mu}m$) Column with on fluent of acetanitrile : water=75 . 25, sufficient separation of Chlorpyrifos and Fluorinate of base was obtained. 2.410td portion the diluted solution was injected in to the cdumn, and the effluent was monitored by on UV-Detector at 270 nm. 3. Relative Standard Deviation were 0.97% (chlorpyrifos) and 0.5% (fluorinate) under analysis conditions. 4. The UV-Detector response at 270 nm were linear (Y=421.8X-2090, $R^2=0.9997$ : Chlorpyrifos, Y= 1062.7X-4017.7, $R^2=0.9998$ : Fluorinate) over a range of 30~500 ${\mu}g/ml$.

  • PDF