• Title/Summary/Keyword: R410A air-conditioning cycle

Search Result 19, Processing Time 0.027 seconds

Comparison of Performance Variation between R-22 and R-410A Refrigeration Systems (운전조건 변화에 따른 R-22 냉동사이클과 R-410A 냉동사이클의 성능변화 비교)

  • 박태준;이민규;정지환;장근선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.166-176
    • /
    • 2003
  • Experiments have been conducted in order to make comparisons of a alternative refrigerant (R-410A) cycle characteristic with an existing refrigerant (R-22) cycle characteristic in terms of cooling capacity and coefficient of performance (COP). The parameters examined in the present work include air flow rate, indoor/outdoor air temperatures, and indoor relative humidity. These two refrigeration cycles share all components except compressor, accumulator, oil separator, and piping connecting them. The measurements were made using an air-enthalpy calorimeter. The experimental results show that the R-410A cycle has many advantages over indoor conditions while the R-22 cycle has better performance over outdoor conditions.

Variations in the Thermal Performance of R22 and R410A Refrigeration Systems Depending on Operation Conditions

  • Jeong, Ji-Hwan;Kweon, Young-Chel;Chang, Keun-Sun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.10-20
    • /
    • 2004
  • Experiments have been conducted in order to make comparisons of characteristics of a R410a cycle with a R22 cycle in terms of cooling capacity and coefficient of performance (COP). The parameters examined in the present work include air flow rate, indoor and outdoor air temperatures, and indoor relative humidity. These two refrigeration cycles constructed for this study share all components except compressor, accumulator, oil separator, and piping. The measurements were made using a psychrometric calorimeter. The experimental results show that the R410A cycle has several advantages for indoor units while the R22 cycle yields better performance for outdoor units.

An experimental study on the performance of a window system air-conditioner using R407C and R410B (R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구)

  • Kim, M.H.;Shin, J.S.;Kim, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

A Combined Rotary Compressor-vane Expander (일체형 로타리 압축기-베인 팽창기)

  • Kim, Hyun Jin;No, Young Jae;Kim, Yong Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.12-19
    • /
    • 2015
  • As a means of improving cycle performance of a R410A air-conditioning system, a combined structure of compressor and expander was introduced. A vane rotary type expander was designed to share a common shaft with twin type rolling piston rotary compressor in a housing. Numerical simulation on the performance of the combined compressor and expander was carried out. At ARI condition, the volumetric and total efficiencies of the designed vane expander were 69.37% and 30.23%, respectively. With the application of this expander, the compressor input was reduced by 3.91%, and the cooling capacity was increased by 3.98%. As a result, COP of the air-conditioning system was improved by 8.2%. As the pressure difference between the condenser and the evaporator becomes large, COP improvement increases unless the mass flow rate in the expander exceeds that in the compressor.

The Performance Evaluation of R407C and R410B in a Residential Window Air-Conditioner

  • Kim, Man-Hoe;Shin, Jeong-Seob;Kim, Kwon-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.148-157
    • /
    • 1998
  • This study presents test results of a residential window air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests has been carried out for the basic and liquid-suction heat exchange cycles in a psychometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-suction heat exchange cycle was also considered to improve the system performance. Test results were compared with those for the basic R22 system. The modified system with a liquid-suction heat exchanger increased cooling capacity and energy efficiency by up to 5%.

  • PDF

A Generalized Correlation and Rating Charts for Mass Flow Rate through Capillary Tubes with Several Alternative Refrigerants

  • Choi Jong Min;Jang Yong Hee;Kim Yongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.192-197
    • /
    • 2004
  • A capillary tube, which is a common expansion device in small sized refrig-eration and air-conditioning systems, should be redesigned properly to establish an optimum operation cycle of a refrigerating system with alternative refrigerants. Based on experimental data for R-22, R-290, and R-407C, an empirical correlation is developed to predict mass flow rate through capillary tubes. Dimensionless parameters are derived from the Buckingham Pi theorem, considering the effects of operating conditions and capillary tube geometry on mass flow rate. Approximately $97\%$ of the present data are correlated within a relative deviation of $\pm\;10\%.$ The present correlation also predicts the data obtained from open literature within $\pm\;15\%.$ In addition, rating charts of refrigerant flow rate for R-12, R-22, R-134a, R-152a, R-407C, R-410A, R-290, and R-600a are developed.

Two-Stage compression cycle operating with alternative refrigerant using by EES program (EES를 이용한 대체냉매 작동 2단압축냉동사이클의 성능해석)

  • Park, Chun-Wan;Lee, Dong-Gyu;Choi, Seung-Kil;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.533-538
    • /
    • 2009
  • The present study has been conducted to an analysis of two stage refrigeration cycle with alternative refrigerant R410A. In the analysis, single stage cycle (R22 and R410A) compared to COP changing with supercooling degree. Secondly, two stage refrigeration cycle is investigated to the existence of intercooler or supercooler. At results, supercooler contributes to the increase of cooling capacity and the decrease of COP.

  • PDF

Air-conditioner cycle simulation using tube-by-tube method (관순법을 이용한 공조기 사이클 시뮬레이션)

  • Yoon, Baek;Park, Hyun-Yeon;Yoo, Guk-Chul;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.499-510
    • /
    • 1999
  • A computer program was developed for simulating performance(capacity, power consumption and etc.) of air-conditioners using compressor, fin-tube heat exchanger and capillary tube. The program consists of five modules, condenser, evaporator, compressor, capillary tube simulation modules and properties modules of refrigerant and moist air, The present program is focused on R22 only, however can be easily extended for other refrigerants such as R407C and R410A just by adding property modules. The compressor simulation module utilizes performance maps supplied by manufacturers-map-based model. The condenser and evaporator simulation modules are modeled using tube-by-tube method. Simulation results(capacity and power consumption) were compared with calorimeter test results of actual air-conditioners of window and split types, where more than 82% of the data lied within ${\pm}5$% of the predicted results.

  • PDF

Performance Analysis of Scroll Expander-Compressor Unit for $CO_2$ Transcritical Cycles ($CO_2$ 초임계 사이클을 위한 일체형 스크롤 팽창기-압축기 성능해석)

  • Kim Hyun-Jin;Nam Bo-Young;Ahn Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.434-442
    • /
    • 2006
  • In a two-stage compression $CO_2$ transcritical cycle, application of a scroll expander-compressor unit has been considered in order to improve the cycle COP. For both expander and 1st stage compressor, scroll wrap profile which was originally designed for a R410A air-conditioning cycle mechanism was used with minor modifications: wrap height and involute end angle were adjusted for required displacement volume and built-in volume ratio. For pressure condition of 10 Mpa/3.5 MPa and expander inlet temperature of $35^{\circ}C$, 25% improvement in COP was obtained by using expander-compressor unit. As evaporator pressure increased, COP improvement was lowered mainly due to decreasing compressor peformance.

Performance Characteristics of Cascade Refrigeration System Using R744 and R410A (R744-R410A용 이원 냉동시스템 성능 특성)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1548-1554
    • /
    • 2013
  • This paper presents the analysis on performance characteristics of R744-R410A cascade refrigeration system to offer the basic design data for the operating parameters of this system. The performance of cascade refrigeration system is analyzed by using EES program. The operating parameters include compressor efficiency, and condensing and evaporating temperature in R410A high- and R744 low-temperature cycle, respectively. The COP of this system increases with the decrease of condensing temperature, and increases with the increasing evaporating temperature. And the COP of this system increases with the compression efficiency. Therefore, it can be seen that the compression efficiency, and evaporating and condensing temperature of R744-R410A cascade refrigeration system have an effect on the COP of this system. Also, it can be known that the cascade evaporation temperature with the highest efficiency in each parameter is present. Thus, it is an important to design R744-R410A cascade refrigeration system by considering these parameters.