• Title/Summary/Keyword: R410A

Search Result 305, Processing Time 0.025 seconds

Numerical Study on the Performance of a Fin-and-Tube Condenser with Non-Uniform Air Distribution and Different Tube Types (불균일 공기분포와 관의 종류에 따른 핀-관 응축기의 성능 특성에 관한 해석적 연구)

  • Cho, Da Young;Hahm, Hyung Chang;Park, Chang Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.12
    • /
    • pp.858-866
    • /
    • 2012
  • A numerical study was performed to predict the performance of a fin-and-tube condenser. A condenser model was developed and verified by comparing the simulation results with experimental data for a R410A condenser in a residential air-conditioning system. The prediction error was 0.07% and -5.77% for the condenser capacity and pressure drop, respectively. In simulation results, the capacity and pressure drop of the condenser with even air velocity distribution were 0.67% and 12.93% higher than those with uneven distribution of air velocity. It was predicted by the model that the refrigerant distribution at the condenser inlet to the two first passes was not significantly influenced by the air distribution. The simulation results presented that the 1.49% of capacity and 64.6% of pressure drop were reduced by replacing helical microfin tubes with smooth tubes for the condenser.

Heating Performance Characteristics of a Heat Pump with a Variable Speed Injection Scroll Compressor (인젝션형 가변속 스크롤 압축기를 적용한 히트펌프의 난방성능 특성에 관한 연구)

  • Ko, Suk-Bin;Heo, Jae-Hyeok;Cho, Il-Yong;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.377-384
    • /
    • 2012
  • Vapor injection technique has been applied to prevent performance degrdation of a heat pump at low ambient temperatures. In this study, the heating performance of a heat pump with a variable speed injection scroll compressor using R-410A was investigated by applying sub-cooler vapor injection(SCVI) and flash tank vapor injection(FTVI). The heating performance of the heat pump was measured by varying compressor frequency and outdoor temperature. The heating capacity of the FTVI system was 8~10% higher than that of the SCVI system at all operating conditions. On the other hand, the heating performance improvement with the increase in the compressor frequency was more prominent in the SCVI system than in the FTVI system.

Purification of a major protein with physiological activities from Panax ginseng C. A. Meyer (고려인삼(Panax ginseng C. A. Meyer)에서 생리활성을 보이는 25 kDa 주요단백질 (GMP)의 분리정제)

  • Kwon, Taek-H.;Oh, Sei-R.;Park, H.;Kim, Kyung-H.
    • Applied Biological Chemistry
    • /
    • v.41 no.6
    • /
    • pp.410-413
    • /
    • 1998
  • The major protein (GMP) from the roots of Panax ginseng C. A. Meyer was purified, using gel filtration and ion exchange chromatography followed by reversed-phase and ion exchange FPLC. Staining analysis indicated that the protein has a carbohydrate moiety, which was also shown by band shift experiments using various glycosidases. Electrophoretic and gel permeation studies showed that GMP has an apparent molecular weight of 63 kDa composed of possibly two subunits of 25 kDa containing carbohydrate moiety. GMP showed an anticomplementary activity on the hemolysis of red blood cells, which is a screening tool for inflammation mediator search.

  • PDF

Study on longitudinal variation of subcooling with high elevated liquid line in a modular heat pump system (모듈형 동시냉난방 열펌프의 장배관/고낙차에 따른 액선 과냉도 변화에 대한 연구)

  • Shin, Kwang-Ho;Kim, Min-Sung;Baik, Young-Jin;Ra, Ho-Sang;Park, Sung-Ryung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1255-1260
    • /
    • 2008
  • This study is simulation of high elevated liquid line of a modular heat pump system to observe longitudinal subcooling variation. In a high elevated tube, subcooled refrigerant(R410A) through a condenser changes its states by heat transfer with surrounding air and by pressure drop from elevation. In this study, the liquid line was simulated through correlations of heat transfer and pressure drop for the variation from single-phase into two-phase flow. Pressure drop, heat transfer rate and vapor quality were calculated as key parameters. Two-phase turning heights and variations of the key parameters were confirmed from the simulation. As a result, high elevation of liquid line has great influence on upward flow, which requires additional equipment to compensate the variation.

  • PDF

Effect of displacement volume ratio on compressor performance for a twin rotary compressor (트윈 로타리 압축기의 행정 체적비가 압축기 성능에 미치는 영향)

  • Ahn, Jong-Min;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.171-176
    • /
    • 2008
  • As one way of design optimization of two-stage two-cylinder rotary compressor used for R410A heat pump application, displacement volume ratio, being defined by the ratio of the second stage cylinder volume to that of the first stage, has been varied and its effect on the compressor performance has been investigated by a computer simulation program. For simplicity, only the cylinder height of the second stage was varied to change the volume ratio. With increasing the volume ratio in the range of VR=$0.55{\sim}0.9$, volumetric efficiency increased monotonically, but adiabatic efficiency showed a maximum at around VR=0.6. Mechanical efficiency was little influenced by the volumetric ratio. As a consequence, maximum improvement of the compressor performance was found at around VR=0.7. Compared to a one-stage two-cylinder rotary compressor with about the same cooling capacity, COP improvement was about 6.96%.

  • PDF

Red fluorescence of oral bacteria interacting with Porphyromonas gingivalis (Porphyromonas gingivalis가 일부 구강미생물의 형광 발현에 미치는 영향)

  • Kim, Se-Yeon;Woo, Dong-Hyeob;Lee, Min-Ah;Kim, Ji-Soo;Lee, Jung-Ha;Jeong, Seung-Hwa
    • Journal of Korean Academy of Oral Health
    • /
    • v.41 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Objectives: Dental plaque is composed of 700 bacterial species. It is known that some oral microorganisms produce porphyrin, and thus, they emit red fluorescence when illuminated with blue light at a specific wavelength of <410 nm. Porphyromonas gingivalis belongs to the genus Porphyromonas, which is characterized by the production of porphyrin. The aim of this study was to evaluate red fluorescence emission of some oral microorganisms interacting with P. gingivalis. Methods: Five bacterial strains (P. gingivalis, Streptococcus mutans, Lactobacillus casei, Actinomyces naeslundii, and Fusobacterium nucleatum) were used for this study. Tryptic soy agar medium supplemented with hemin, vitamin K3, and sheep blood was used as a growth medium. The fluorescence emission of bacterial colonies was evaluated under 405 nm-wavelength blue light using a Quantitative Light-induced Fluorescence Digital (QLF-D) camera system. Each bacterium was cultured alone and co-cultured in close proximity with P. gingivalis. The red/green (R/G) ratio of fluorescence image was calculated and the differences of R/G ratio according to each growth condition were compared using the Mann-Whitney test (P<0.05). Results: Single cultured S. mutans, L. casei and A. naeslundii colonies emitted red fluorescence (R/G ratio=$2.15{\pm}0.06$, $4.31{\pm}0.17$, $5.52{\pm}1.29$, respectively). Fusobacterium nucleatum colonies emitted green fluorescence (R/G ratio=$1.36{\pm}0.06$). The R/G ratios of A. naeslundii and F. nucleatum were increased when P. gingivalis was co-cultured with each bacterium (P<0.05). In contrast, the R/G ratios of S. mutans and L. casei were decreased when P. gingivalis was co-cultured with each bacterium (P=0.002, 0.003). Conclusions: This study confirmed that P. gingivalis could affect the red fluorescence of other oral bacteria under 405 nm-wavelength blue light. Our findings concluded that P. gingivalis has an important role for red fluorescence emission of dental biofilm.

Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Cooling-main Operating Mode (냉방주체 운전모드에서 동시냉난방 열펌프 성능향상에 관한 실험적 연구)

  • Chung, Hyun-Joon;Joo, Young-Ju;Kang, Hoon;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.314-320
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the improved wall insulation. Hence, a multi~heat pump is required to cover heating and cooling simultaneously for each indoor unit. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-main operating mode were investigated experimentally. The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the cooling-main mode, the heating capacity decreased due to reduction of flow rate to the indoor unit under heating mode operation. The EEV opening was adjusted to increase flow rate to the indoor unit under heating mode operation. The total capacity and COP in the cooling-main mode increased by 20.5% and 29.2%, respectively, compared with those in the cooling-only mode.

A four variable refined nth-order shear deformation theory for mechanical and thermal buckling analysis of functionally graded plates

  • Fahsi, Asmaa;Tounsi, Abdelouahed;Hebali, Habib;Chikh, Abdelbaki;Adda Bedia, E.A.;Mahmoud, S.R.
    • Geomechanics and Engineering
    • /
    • v.13 no.3
    • /
    • pp.385-410
    • /
    • 2017
  • This work presents a simple and refined nth-order shear deformation theory for mechanical and thermal buckling behaviors of functionally graded (FG) plates resting on elastic foundation. The proposed refined nth-order shear deformation theory has a new displacement field which includes undetermined integral terms and contains only four unknowns. Governing equations are obtained from the principle of minimum total potential energy. A Navier type analytical solution methodology is also presented for simply supported FG plates resting on elastic foundation which predicts accurate solution. The accuracy of the present model is checked by comparing the computed results with those obtained by classical plate theory (CPT), first-order shear deformation theory (FSDT) and higher-order shear deformation theory (HSDT). Moreover, results demonstrate that the proposed theory can achieve the same accuracy of the existing HSDTs which have more number of variables.

Usability Evaluation of Graphic User Interfaces for a Military Computer-Based Training System

  • Kim, Sungho;Lee, Soojung;Lee, Kiwon;Lee, Baekhee;Lee, Jihyung;Park, Seikwon;You, Heecheon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.401-410
    • /
    • 2015
  • Objective: The present study was to improve the graphic user interface (GUI) of a military computer-based training (CBT) system in terms of usability. Background: Existing studies have focused on usability evaluation of a particular GUI type such as sequence, hierarchy, or context type; however, few research has been conducted which identifies preferred GUI features based on a comparative analysis of different GUI types. Method: A comparative evaluation was conducted by 9 CBT design experts using a 7-point scale (1: very low, 4: neutral, and 7: very high) on hierarchy and context GUI types of a military CBT system in terms of 10 usability criteria. Then, preferred features of the hierarchy and context types being accommodated, a new GUI was developed and validated by 22 CBT users. Results: While the hierarchy type was found preferred by 1.6 times in terms of controllability to the context type, the opposite was found in terms of attractiveness, simplicity, and responsiveness by 0.6, 0.8, and 0.8 times, respectively. The proposed GUI was found superior to the hierarchy and context types in terms of accessibility and informativeness by more than 1.5 times, but inferior to the hierarchy and context type in terms of simplicity by 0.6 and 0.9 times, respectively. Conclusion: The new GUI developed by accommodating the preferred features of the hierarchy and context types improves usability in terms of accessibility and informativeness except simplicity. Application: The comparative analysis of various GUIs can be applied to develop an improved GUI in a systematic manner based on preferred features of the existing GUIs.

1D AND 3D ANALYSES OF THE ZY2 SCIP BWR RAMP TESTS WITH THE FUEL CODES METEOR AND ALCYONE

  • Sercombe, J.;Agard, M.;Struzik, C.;Michel, B.;Thouvenin, G.;Poussard, C.;Kallstrom, K.R.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.187-198
    • /
    • 2009
  • In this paper, three power ramp tests performed on high burn-up Re-crystallized Zircaloy2 - UO2 BWR fuel rods (56 to 63 MWd/kgU) within the SCIP project are simulated with METEOR and ALCYONE 3D. Two of the ramp tests are of staircase type up to Linear Heat Rates of 420 and 520 W/cm and with long holding periods. Failure of the 420 W/cm fuel rod was observed after 40 minutes. The third ramp test consisted of a more standard ramp test with a constant power rate of 80 W/cm/min up to 410 W/cm with a short holding time. The tests were first simulated with the METEOR 1D fuel rod code, which gave accurate results in terms of profilometry and fission gas releases. The behaviour of a fuel pellet fragment and of the cladding piece on top of it was then investigated with ALCYONE 3D. The size and the main characteristics of the ridges after base irradiation and power ramp testing were recovered. Finally, the failure criteria validated for PWR conditions and fuel rods with low-to-medium burn-ups were used to analyze the failure probability of the KKL rodlets during ramp testing.