• 제목/요약/키워드: R32

검색결과 4,130건 처리시간 0.032초

R-404A/POE 오일 혼합물의 증기압과 혼화성 (Vapor Pressure and Miscibility for R474A/POE Oil Mixtures)

  • 이정훈;박영무
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.285-292
    • /
    • 2002
  • The vapor pressure and miscibility measurement apparatus was developed and used to obtain data for refrigerant/oil mixture. The vapor pressure and miscibility data for R-404A/32 ISO VG polyol ester (POE) oil mixture and R-404A/46 ISO VG polyol ester oil mixture are obtained over the temperature range from -20 to $60^{\circ}$ with at $10^{\circ}$ intervals and the oil concentration range from 0 to 70 wt%. Using the experimental data, an empirical model was developed to predict the temperature vapor pressure-concentration relations for R-404A/46 ISO VG polyol ester oil mixtures at equilibrium. In the R-404A/32 ISO VG polyol ester oil mixture, the average root-mean-square deviation between measured data and calculated results from the empirical model is 1.24% and in the R-404A/46 ISO VG polyol ester oil mixture, that is 1.37%. Miscibility for R-404A/32 ISO VG polyol ester oil mixture was observed all over the experimental conditions. Immiscibility for R-404A/So1est 46 oil mixture was observed at the low oil concentrations (20~30 wt%) over the high experimental temperature range (50~$60^{\circ}$).

R-410A/POE 오일 혼합물의 기-액상평형과 상용성에 관한 연구 (Investigation of Vapor-Liquid Equilibrium and Miscibility for R-410A/POE Oil Mixtures)

  • 김창년;송준석;이은호;박영무;유재석;김기현
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.589-598
    • /
    • 2000
  • The vapor-liquid equilibrium and miscibility measurement apparatus was developed and used to obtain data for refrigerant/oil mixture. The vapor-liquid equilibrium and miscibility data for R-410a/POE32 and R-410A/POE46 oil mixtures are obtained over the temperature range from -20 to $60^{\circ}C\;with\;10^{\circ}C$ intervals and the oil concentration range from 0 to 90 wt%. Using the experimental data, an empirical model is developed to predict the temperature-pressure-concentration relations for R-410A/POE oil mixtures at equilibrium. In the R-410A/POE32 oil mixture, the average root-mean-square deviation between measured data and calculated results from the empirical model is 2.00% and in the R-410a/POE46 oil mixture, that is 3.69%. Flory-Huggins theory is also used to predict refrigerant/oil mixture behavior. Miscibility for R-410A/POE32 oil mixture was observed all over the experimental conditions. Immiscibility for R-410A/POE46 oil mixture was observed at the low oil concentrations(10~30 wt%).

  • PDF

대체혼합냉매를 사용하는 Lorentz-Meutzner의 이중 증발기 냉동 시스템의 성능에 관한 연구 (A Study of Lorentz-Meutzner's Two Evaporator Refrigeration System Using Alternative Refrigerant Mixtures)

  • 박영무
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.123-136
    • /
    • 1992
  • A preliminary thermodynamic design model of two-evaporator refrigerator/freezer system is constructed. This system is based on Lorentz-Meutzner cycle using refrigerant mixtures. This model screens alternative refrigerant (R32, R125, R143a, R22, R134a, R152a, R124, R142b, R123) mixtures to select the best performance-giving refrigerant mixtures and its composition for the system. Also, it estimates the effects of cooling temperatures of intercoolers, evaporator's area ratio, cooling load ratio on the performance of the system. The COP of the system ranges from 1.4 to 1.6, which is superior to that of the single evaporator system charged with R12 by 13% to 29%. Among 15 mixtures, R22/R123, R143a/R123, R32/R142b, and R32/R124 (in the order of high COP) are most recommendable. For the case of R22/R123, R22 mass fraction more than 0.5(Load Ratio=1.0) or 0.7(Load Ratio=0.33) is recomended in order to replace R12 without reduction in volumetric capacity when keeping the compressor as the same one. COP has the highest value with X(R22)=0.7 and 0.8, respectively. For the case of R143a/R123, in the similar manner, mass fraction of R143a is more than 0.5 or 0.6 while best performance occurs at X(R143a)=0.8. Higher temperature intercooler is more important for the performance of the system than lower temperature intercooler. The area ratio of evaporators is roughly proportional to load ratio of the evaporators.

  • PDF

Synthetic MR을 이용한 정량적 평가에서 Coil channel 수 변화에 따른 재현성 평가 (Evaluation of Reproducibility According to Variation of Coil Channel in Quantitative Evaluation Using Synthetic MR)

  • 권순용;김성호
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.343-351
    • /
    • 2017
  • 최신 영상 기법인 MAGiC sequence의 RF coil channel 수 변화에 따른 T1, T2 이완 시간 및 T1, T2 이완율을 측정하여 분석하였고 그에 따른 재현성을 평가하였다. Channel 수가 각각 (1, 8, 16, 32)channel 인 RF coil에 조영제 phantom(1.0, 0.6, 0.2, 0mM)을 위치시키고 MAGiC sequence를 이용하여 T1, T2, R1, R2 map을 획득하였다. 그리고 각각의 channel 수와 농도별로 T1, T2, R1, R2 value 그리고 relaxation rate를 측정하였고 이를 기반으로 각 농도에 따른 Relaxivity를 구하였다. 각각의 coil에서 T1, T2, R1, R2 value를 측정한 결과 T1, R1 value는 coil간의 유의한 차이가 없었다(p>0.05). 하지만 T2, R2 value는 유의한 차이가 있는 것으로 나타났다(p<0.05). 사후분석 결과에서는 T2 value의 경우 1 channel coil에서 측정한 결과가 8, 16, 32 channel coil에서 측정한 결과와 유의한 차이가 나타났고(p<0.05) 8, 16, 32 channel coil간의 차이는 나타나지 않았다(p>0.05). R2 value의 경우도 마찬가지로 1 channel coil에서 측정한 결과가 8, 16, 32 channel coil에서 측정한 결과와 유의한 차이가 나타났으며 또한 8 channel coil에서 측정한 결과와 16 channel coil에서 측정한 결과가 유의한 차이가 나타났다(p<0.05). 결론적으로 T1, R1 value는 coil의 channel 수 변화에 따른 차이가 크지 않지만 T2, R2 value는 큰 차이를 나타냈다. 따라서 MAGiC sequence를 이용하여 T2, R2 value를 정량적으로 측정할 경우 재현성을 위해 동일한 channel 수의 coil을 사용해야 할 것으로 사료된다.

RI PHOTOMETRY OF 32 CYGNI

  • Jeong, Jang-Hae;Kim, Yong-Gi;Nha, Il-Seong
    • Journal of Astronomy and Space Sciences
    • /
    • 제9권2호
    • /
    • pp.135-142
    • /
    • 1992
  • Surface activity of the late-type supergiant component of $\zeta$ Aurtype eclipsing binary 32 Cyg has been searched in R and I passbands for 53 nights in the 1991 season. Atmospheric extinctions in these wavelength regions are made and a linear relation between the two coefficients has been found. All the data are standardized and determined the magnitudes and colors of 32 Cyg. R, I and color curves of 32 Cyg at the outside eclipse phase are presented.

  • PDF

여성 노인의 자세 정렬과 시공간 보행 변수 사이의 연관성 (Relationship Between the Postural Alignments and Spatio-temporal Gait Parameters in Elderly Woman)

  • 김성현;신호진;서혜림;정경심;조휘영
    • 대한물리의학회지
    • /
    • 제15권3호
    • /
    • pp.117-125
    • /
    • 2020
  • PURPOSE: Aging causes changes in the postural alignment and gait due to changes in the nervous and musculoskeletal systems. On the other hand, the relationship between the changes in posture alignment and gait is unclear. This study examined the relationship between the postural alignment and spatiotemporal gait parameters in Korean elderly women. METHODS: Thirty-two-healthy elderly women participated in this study. All subjects were assessed for their posture alignment and gait ability. Stepwise multiple linear regression was performed to determine to what extent the postural alignments could explain the spatiotemporal gait parameters. RESULTS: Coronal head angle was moderately correlated with the velocity (r = -.51), normalized velocity (r = -.46) and gait-stability ratio (r = .58) (p < .05). The trunk angle was moderately correlated with the normalized velocity (r = -.32) and gait-stability ratio (r = .32) and weakly correlated with the velocity (r = -.28) (p < .05). The coronal shoulder angle was moderately correlated with the swing phase (r = -.57), stance phase (r = .56), single limb stance (r = -.56) and double limb stance (r = .51) (p < .05). The coronal head angle and trunk angle accounted for 36% of the variance in velocity, 33% variance in normalized velocity and 46% variance in the gait-stability ratio (p < .05). The coronal shoulder angle accounted for 32% variance in the swing phase, 32% variance in the stance phase, 31% variance in the single limb stance and 26% variance in the double limb stance (p < .05). CONCLUSION: Changes in posture alignment in elderly women may serve as a biomarker to predict a decrease in walking ability due to physical aging.

Routley-Meyer Semantics for E-R, Ee-R, Eec-R

  • Yang, Eun-Suk
    • 논리연구
    • /
    • 제6권1호
    • /
    • pp.19-32
    • /
    • 2003
  • In this paper we investigate the relevance logic E-R of the Entailment E without the reductio (R), and its extensions Ee-R, Eec-R: Ee-R is the E-R with the expansion (e) and Eec-R the Ee-R with the chain (c). We give completeness for each E-R, Ee-R, and Eec-R by using Routley-Meyer semantics.

  • PDF

R32를 포함한 R22 대체 혼합냉매의 모세관 유동 특성 (Flow Characteristics of Refrigerant Mixtures with R32 in a Capillary Tube)

  • 장세동;노승탁
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.177-186
    • /
    • 1996
  • The characteristics of the flow of pure HFC refrigerants(R32, R125, and R134a) and their mixtures through capillary tubes were investigated experimentally. Two capillary tubes with 1.2mm and 1.6mm inner diameter and 1.5m length were adopted as test sections. Mass flow rates and temperatures and pressures were measured for several condensing temperatures and degrees of subcooling at capillary tube inlet. The effects of the condensing temperature, inner diameter of capillary tube, and subcooling on the mass flow rate of refrigerants were discussed, and the mass flow rates of HFC refrigerants were compared with that of R22. The pressure and temperature distributions along the capillary tube compared with that of R22. The pressure and temperature distributions along the capillary tube show that there is a metastable equilibrium state in the flow through the tube. Underpressure for vaporization increases as refrigerant mass flux increases and inlet subcooling decreases. Empirical correlation was suggested to predict underpressure for vaporization of the HFC refrigerants.

  • PDF

R12 및 R22대체냉매의 열역학적 물성치 및 냉동기의 성능비교 (Thermodynamic Properties of Alternatives for R12, R22 and Performances of Refrigerator)

  • 장세동;신지영;노승탁
    • 설비공학논문집
    • /
    • 제5권1호
    • /
    • pp.73-83
    • /
    • 1993
  • Thermodynamic properties of alternatives for R12 and R22 were estimated and performances of refrigerating cycle using these refrigerants were compared. In this study, we adopt R134a, R22/R142b, R22/R152a, R22/R152a/R124 as alternatives for R12 and R32/R134a for R22. Thermodynamic properties of these refrigerants were estimated using modified CSD equation of state. Cycle simulations of the refrigerating system considering heat source were carried out in order to compare the performance of the system. R134a shows relatively lower COP than R12 but very similar VCR. R22/R142b(50/50 mass fraction), R22/R152a(10/90), R22/R152a/R124(30/25/45) are good for the substitutes of R12 and R32/R134a(30/70) is appropriate for that of R22 in view of COP and VCR.

  • PDF