• Title/Summary/Keyword: R22

Search Result 5,870, Processing Time 0.037 seconds

Condensation heat transfer characteristics of hydrocarbon. refrigerants inside horizontal tubes (수평평활관내 탄화수소계 냉매의 응축전열 특성에 관한 연구)

  • 이용언;박승준;정진호;장승환;오후규
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.15-20
    • /
    • 2001
  • This study investigated the condensation heat transfer coefficients of R-22, R-290 and R-600a inside horizontal tube. Heat transfer measurements were peformed for smooth tube with outside diameter of 12.7 mm Condensation temperatures and mass velocity were ranged from 308 K to 323 K and $51kg/\textrm{m}^2s$s to $250kg/\textrm{m}^2s$, respectively. The test results showed that the local condensation heat transfer coefficients increased as the mass flux increased, and also the effects of mass velocity on heat transfer coefficients of R-290 and R-600a were less than R-22. Average condensation heat transfer coefficients of natural refrigerants were superior to that of R-22. The present results had a good agreement with Haraguchi's correlation.

  • PDF

Performance Characteristics of Refrigeration and Air Conditioning System Using Hydrocarbon Refrigerants (탄화수소계 냉동공조 시스템의 성능특성에 관한 실험)

  • 이호생;이근태;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.728-734
    • /
    • 2004
  • Environmentally friendly refrigerants with zero ozone layer depletion potential are required to be used in refrigerators and air conditioners due to the difficulties related to ozone layer depletion and global warming. A rigorous study for the system performance with new refrigerants having zero ozone layer depletion potential is inevitable before adopting that as a new fluid. The HFC(Hydrofluorocarbon) potential has been recommended as alternatives. In this paper. system performance in the heat pump facilities were studied using R-290, R-600a. R-1270 as an environment friendly refrigerant. R-22 as a HCFC's refrigerant. The experimental apparatus has been set-up as a conventional vapor compression type heat Pump system. The test section is a horizontal double pipe heat exchanger. A tube diameter of 12.70mm with 1.315mm wall thickness is used for this investigation. The test results showed that the COP of hydrocarbon refrigerants were superior to that of R-22 and the maximum increasing rate of COP was found in R-1270. The refrigeration capacity of hydrocarbon refrigerants were higher than that of R-22. The compressor work was obtained with the maximum value in R-1270 and the minimum one in R-22.

A Study on the Relationship between Working Patterns and Health Conditions and Eating Habits of Workers in the Gyeongnam Area (경남지역 일부 직장인들의 근무형태와 건강상태, 식습관의 관련성 연구)

  • Seo, Eun Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.33 no.3
    • /
    • pp.266-278
    • /
    • 2020
  • This study was conducted with 375 workers in Changwon to examine the effects of working patterns on dietary habits and health. A self-administered questionnaire was conducted July 22 October 30, 2019. According to the results of the dietary habits and health related factors analysis, non-shift administrative workers showed significantly higher rates of green tea intake (p<0.05), and shift production workers showed significantly higher smoking rates (p<0.001) and waist circumferences (p<0.01). According to the results of the Pearson's correlation coefficient analysis, work hours showed negative correlations with job satisfaction (r=0.22, p<0.01) and positive correlations with perceived stress level (r=0.14, p<0.01). Temporary workers showed negative correlations with feel job satisfaction(r=0.14, p<0.01), perceived stress level (r=0.12, p<0.05), and concern about health (r=0.13, p<0.05). Diabetes showed positive correlations with hypertension (r=0.20, p<0.01), low HDL cholesterolemia (r=0.22, p<0.01), abdominal obesity (r=0.13, p<0.05), and hypertriglyceridemia(r=0.22, p<0.01). Based on these results, this researcher proposes that continuous attention and support of industries and communities are necessary for nutritional education and counseling relative to improving workers' dietary lives as well as disease prevention and control.

Effect of Refrigeration Oil on the Condensation Heat Transfer for R-22 and R-407C Refrigerations in Microfin Tube with a U-bend

  • Cho, Keum-Nam;Tae, Sang-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.85-93
    • /
    • 2001
  • The present study experimentally investigated the effect of refrigeration oil on the condensation heat transfer for R-22 and R-407C in a microfin tube with a U-bend. Mineral oil and POE oil were used for R-22 and R-407C respectively. Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to 400 $kg/m^2s$ and an inlet quality from 0.5 to 0.9. The enhancement factors for both R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. The decreased rapidly as the mass flux decreased and the inlet quality increased. The heat transfer coefficients in the U-bend showed the maximum at the 90$^{\circ}$position. the heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficient at the first straight section.

  • PDF

The Condensation Pressure Drop of Alternative Refrigerants for R-22 in Small Diameter Tubes (세관내 R-22 대체냉매의 응축압력강항에 관한 연구)

  • O, Hu-Gyu;Son, Chang-Hyo;Choe, Yeong-Seok;Kim, Gi-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1245-1252
    • /
    • 2001
  • The condensation pressure drop for pure refrigerants R-22, R-134a, and a binary refrigerant mixture R-410A flowing in a small diameter tube was investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and coolant flowing in the annulus. The test section consists of 1220 [mm] length with horizontal copper tube of 3.38 [mm] outer diameter and 1.77 [mm] inner diameter. The refrigerant mass fluxes ranged from 450 to 1050 [kg/(㎡$.$s)] and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main experimental results were summarized as follows : In the case of single-phase flow, the pressure drop of R-134a is much higher than that of R-22 and R-410A for the same Reynolds number. The friction factors for small diameter tubes are higher than those predicted by Blasius equation. In the case of two-phase flow, the pressure drop increases with increasing mass flux and decreasing quality. The pressure drop of R-134a is much higher than that of R-22 and R-410A for the same mass flux. Most of correlations proposed in the large diameter tube showed enormous deviations with experimental data. However, the correlation predicted by Honda et al showed relatively good agreement with experimental data for R-134.

Performance of HFC32/HFC152a Mixture for Water-source Heat Pumps (수열원 히트펌프 용 HFC32/HFC152a 혼합냉매의 성능평가)

  • Kang, Dong-Gyu;Kim, Wook-Jin;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.391-400
    • /
    • 2012
  • In this study, performance of HFC32/HFC152a mixture is measured in the composition range of 20 to 50% R32 with an interval of 10% for the comparison with the conventional HCFC22 in water-source heat pumps. Tests are carried out under the same capacity in a heat pump bench tester equipped with a variable speed compressor at the evaporation and condensation temperatures of 7/$45^{\circ}C$ and -7/$41^{\circ}C$ for summer and winter conditions, respectively. Test results show that the compressor power of the HFC32/HFC152a mixture is 13.7% lower than that of HCFC22 while the coefficient of performance(COP) the HFC32/HFC152a mixture is 15.8% higher than that of HCFC22. Hence, from the view point of energy efficiency, the HFC32/HFC152a mixture is excellent as compared to HCFC22. Compressor discharge temperatures of HFC32/HFC152a mixture are increased up to $15.4^{\circ}C$ as compared to that of HCFC22. The amount of charge for HFC32/HFC152 mixture decrease up to 27% as compared to that of HCFC22. Overall, HFC32/ HFC152a mixture is an excellent long term candidate to replace HCFC22 in water-source heat pumps.

Evaporation Heat Transfer Characteristics of Hydrocarbon Refrigerants R-290 and R-600a in the Horizontal Tubes

  • Roh, Geon-Sang;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.74-83
    • /
    • 2007
  • This paper presents the experimental results of evaporation heat transfer coefficients of HC refrigerants (e.g. R290 and R600a). R-22 as a HCFCs refrigerant and R-l34a as a HFCs refrigerant in horizontal double pipe heat exchangers, having four different inner diameters of 10.07, 7.73, 6.54 and 5.80 mm respectively. The experiments of the evaporation process were conducted at mass flux of $35.5{\sim}210.4 kg/m^2s$ and cooling capacity of $0.95{\sim}10.1 kW$. The main results were summarized as follows : The average evaporation heat transfer coefficient of hydrocarbon refrigerants(R-290 and R-600a) was higher than the refrigerants, R-22 and R-l34a. In comparison with R-22 the evaporation heat transfer coefficient of R-l34a is approximately $-11{\sim}8.1 %$ higher. R-290 is $56.7{\sim}70.1 %$ higher and R-600a is $46.9{\sim}59.7 %$ higher. respectively. In comparison with experimental data and some correlations, the evaporation heat transfer coefficients are well predicted with the Kandlikar's correlation regardless of a type of refrigerants and tube diameters.

Performance Analysis of a Heat Pump Using Refrigerant Mixtures (II) (혼합냉매를 사용한 열펌프의 성능해석 (II))

  • Kim, M.S.;Kim, T.S.;Won, S.P.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.218-225
    • /
    • 1990
  • Studies on the performance of a heat pump using non-azeotropic refrigerant mixtures are done. In order to estimate the thermodynamic properties for the selected non-azeotropic refrigerant mixtures including R22/R152a, R22/R142b, R22/R114 and R13B1/R152a, Peng-Robinson equation of state is adopted. The pressure-enthalpy diagram and the temperature-entropy diagram are plotted for each refrigerant mixture. Considerations on the capacity modulation for the heat pump system using refrigerant mixtures are taken into. Results show that when the heating load varies, the possibility for the capacity modulation is found in the heat pump system using a compressor with constant volume flow rate. Under a constant heating capacity condition in the heat pump system, the coefficient of performance increases when the refrigerant mixtures are used. The volume flow rate decreases as the mass fraction of lower boiler increases in this case.

  • PDF

The Condensation Heat Transfer of Alternative Refrigerants for R-22 in Small Diameter Tubes (세관내 R-22 대체냉매의 응축열전달에 관한 연구)

  • Son, Chang-Hyo;Jeong, Jin-Ho;O, Jong-Taek;O, Hu-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.180-186
    • /
    • 2001
  • The condensation heat transfer coefficients of pure refrigerants R-22, R-134a, and a binary refrigerant mixture R-410A flowing in a small diameter tube were investigated. The experiment apparatus consists of a refrigerant loop and a water loop. The main components of the refrigerant loop consist of a variable-speed pump, a mass flowmeter, an evaporator, and a condenser(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flowmeter. The condenser is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal copper tube of 3.38mm outer diameter and 1.77mm inner diameter. The length of test section is 1220mm. The refrigerant mass fluxes varied from 450 to 1050kg/(㎡$.$s) and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main results were summarized as follows ; in the case of single-phase flow, the heat transfer coefficients increase with increasing mass flux. The heat transfer coefficient of R-410A was higher than that of R-22 and R-134a, and the heat transfer for small diameter tubes were about 20% to 27% higher than those predicted by Gnielinski. In the case of two-phase flow, the heat transfer coefficients also increase with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22 and R-134a. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

Design and Comparison of the Pipelined IFFT/FFT modules for IEEE 802.11a OFDM System (IEEE 802.11a OFDM System을 위한 파이프라인 구조 IFFT/FFT 모듈의 설계와 비교)

  • 이창훈;김주현;강봉순
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.570-576
    • /
    • 2004
  • In this paper, we design the IFFT/FFT (Inverse fast Fourier Transform/Fast Fourier Transform) modules for IEEE 802.11a-1999, which is a standard of the High-speed Wireless LAN using the OFDM (Orthogonal Frequency Division Multiplexing). The designed IFFT/FFT is the 64-point FFT to be compatible with IEEE 802.11a and the pipelined architecture which needs neither serial-to-parallel nor parallel-to-serial converter. We compare four types of IFFT/FFT modules for the hardware complexity and operation : R22SDF (Radix-2 Single-path Delay feedback), the R2SDF (Radix-2 Single-path Delay feedback), R2SDF (Radix-4 Single-path Delay Feedback), and R4SDC (Radix-4 Single-path Delay Commutator). In order to minimize the error, we design the IFFT/FFT module to operate with additional decimal parts after butterfly operation. In case of the R22SDF, the IFFT/FFT module has 44,747 gate counts excluding RAMs and the minimized error rate as compared with other types. And we know that the R22SDF has a small hardware structure as compared with other types.