• 제목/요약/키워드: R2-MRI

검색결과 167건 처리시간 0.027초

Preliminary study of presumptive intradural-intramedullary intervertebral disc extrusion in 20 dogs

  • Kim, Jaehwan;Kim, Hyoju;Hwang, Jeongyeon;Eom, Kidong
    • Journal of Veterinary Science
    • /
    • 제21권4호
    • /
    • pp.52.1-52.11
    • /
    • 2020
  • Background: Intradural-intramedullary intervertebral disc extrusion (IIVDE) is a rare condition of intervertebral disc disease. However, the diagnosis of IIVDE is challenging because the prognosis and imaging characteristics are poorly characterized. Objectives: We aimed to describe the clinical and imaging characteristics of tentatively diagnosed IIVDE in dogs to assess the prognostic utility of neurological grade and magnetic resonance imaging (MRI) findings. Methods: Twenty dogs were included in this retrospective cohort study. Results: Nonchondrodystrophic breeds (n = 16) were more predisposed than chondrodystrophic breeds. Most dogs showed acute onset of clinical signs. Neurological examination at admission showed predominant non-ambulatory paraparesis (n = 9); paresis (n = 16) was confirmed more frequently than paralysis (n = 4). Follow-up neurological examination results were only available for 11 dogs, ten of whom showed neurological improvement and 8 showed successful outcomes at 1 month. The characteristic MRI findings include thoracic vertebra (T)2 hyperintense, T1 hypointense, intramedullary linear tracts with reduced disc volume, and cleft of the annulus fibrosus. None of the MRI measurements were significantly correlated with neurological grade at admission. Neurological grade did not differ according to the presence of parenchymal hemorrhage, parenchymal contrast enhancement, and meningeal contrast enhancement. Neurological grades at admission showed a statistical correlation with those observed at the 1-month follow-up (r = 0.814, p = 0.02). Conclusions: IIVDE is a rare form of disc extrusion commonly experienced after physical activity or trauma and most frequently affects the cranial-cervical and thoracolumbar regions of nonchondrodystrophic dog breeds. Neurological score at admission emerged as a more useful prognostic indicator than MRI findings in dogs with suspected IIVDE.

3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정 (Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System)

  • 류정규;오장훈;김혁기;이선정;서미리내;장건호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2014
  • 목적: $T_2{^*}$이완시간은 조직의 고유한 특징을 반영하는 자화율 정보를 내재하고 있다. 본 연구는 3테슬러 자기공명영상 기기에서 유방의 정상 유선조직과 지방조직의 $T_2{^*}$이완시간을 알아보고자 하였다. 대상과 방법: 52명의 여자환자에서 (나이, $49{\pm}12 $세; 범위, 25세~75세) 삼차원 경사에코연쇄를 이용하여 각 일곱 개 에코 자기공명영상들을 얻었다. 에코시간은 3.91 ms단계에서 2.28 ms에서 25.72 ms사이 범위였다. 화적소를 기초로 $T_2{^*}$이완시간과 $R_2{^*}$이완율 지도는 각 개체에서 선형곡선맞춤을 이용하여 계산되었다. $T_2{^*}$값과 $R_2{^*}$값을 얻기 위하여 유방의 정상 유선조직과 지방조직에 삼차원 관심영역을 표시하였다. 모든 개체에서 이러한 변수들의 평균치를 계산하였다. 결과: 유방의 정상 유선조직과 지방조직에 삼차원 관심영역 크기는 각각 $4818{\pm}4679$ 화적소와 $1455{\pm}785$ 화적소 였다. 평균 $T_2{^*}$ 값은 유방의 정상 유선조직과 지방조직에서 각각, $22.40{\pm}5.61ms$$36.36{\pm}8.77ms$였다. 평균 $R_2{^*}$값은 유방의 정상 유선조직과 지방조직에서 각각, $0.0524{\pm}0.0134/ms$$0.0297{\pm}0.0069/ms$ 였다. 결론: 유방의 정상 유선조직과 지방조직에서 $T_2{^*}$값과 $R_2{^*}$값을 측정하였다. 유방의 정상 유선조직의 $T_2{^*}$값은 지방조직의 $T_2{^*}$값보다 짧게 나타났다. $T_2{^*}$이완시간의 측정은 유방암과 정상 유방조직에서의 자화율 효과를 이해하는데 도움을 줄 것이다.

요추 주변 근육 단면적과 척추전방전위증의 상관성에 대한 후향적 연구 (The Correlation between Cross-sectional Area of Lumbar Paraspinal Muscles and Sponylolisthesis; A Retrospective Study)

  • 박혜성;김제인;김고운;조재흥;송미연
    • 한방재활의학과학회지
    • /
    • 제26권1호
    • /
    • pp.95-102
    • /
    • 2016
  • Objectives To investigate correlation between slip percentage (SP) of spondylolisthesis and cross-sectional area (CSA) of lumbar paraspinal muscles; psoas major (PM), multifidus (MU) and erector spinae (ES). Methods A retrospective study was carried out in 120 spondylolisthesis patients who had visited the Spine center of Kyung Hee University Hospital at Gangdong and had taken lumbar MRI. CSA of lumbar paraspinal muscles was measured from axial T2-weighted MRI and divided by CSA of vertebral body to avoid weight's influence. SP was also measured from sagittal MRI. Results SP increase has significant correlation with decreased CSA-MU (r=0.37, p<0.01) and increased CSA-ES (r=0.19, p<0.05). There was no significant correlation between SP and CSA-PM. Conclusions MU atrophy and ES hypertrophy have significant correlation with SP of spondylolisthesis. CSA of lumbar paraspinal muscles can be a risk factor of progression of spondylolisthesis and compensation for the instability.

Magnetic resonance imaging texture analysis for the evaluation of viable ovarian tissue in patients with ovarian endometriosis: a retrospective case-control study

  • Lee, Dayong;Lee, Hyun Jung
    • Journal of Yeungnam Medical Science
    • /
    • 제39권1호
    • /
    • pp.24-30
    • /
    • 2022
  • Background: Texture analysis has been used as a method for quantifying image properties based on textural features. The aim of the present study was to evaluate the usefulness of magnetic resonance imaging (MRI) texture analysis for the evaluation of viable ovarian tissue on the perfusion map of ovarian endometriosis. Methods: To generate a normalized perfusion map, subtracted T1-weighted imaging (T1WI), T1WI and contrast-enhanced T1W1 with sequences were performed using the same parameters in 25 patients with surgically confirmed ovarian endometriosis. Integrated density is defined as the sum of the values of the pixels in the image or selection. We investigated the parameters for texture analysis in ovarian endometriosis, including angular second moment (ASM), contrast, correlation, inverse difference moment (IDM), and entropy, which is equivalent to the product of area and mean gray value. Results: The perfusion ratio and integrated density of normal ovary were 0.52±0.05 and 238.72±136.21, respectively. Compared with the normal ovary, the affected ovary showed significant differences in total size (p<0.001), fractional area ratio (p<0.001), and perfusion ratio (p=0.010) but no significant differences in perfused tissue area (p=0.158) and integrated density (p=0.112). In comparison of parameters for texture analysis between the ovary with endometriosis and the contralateral normal ovary, ASM (p=0.004), contrast (p=0.002), IDM (p<0.001), and entropy (p=0.028) showed significant differences. A linear regression analysis revealed that fractional area had significant correlations with ASM (r2=0.211), IDM (r2=0.332), and entropy (r2=0.289). Conclusion: MRI texture analysis could be useful for the evaluation of viable ovarian tissues in patients with ovarian endometriosis.

Role of Chemical Exchange Saturation Transfer and Magnetization Transfer MRI in Detecting Metabolic and Structural Changes of Renal Fibrosis in an Animal Model at 3T

  • Anqin Li;Chuou Xu;Ping Liang;Yao Hu;Yaqi Shen;Daoyu Hu;Zhen Li;Ihab R. Kamel
    • Korean Journal of Radiology
    • /
    • 제21권5호
    • /
    • pp.588-597
    • /
    • 2020
  • Objective: To investigate the value of combined chemical exchange saturation transfer (CEST) and conventional magnetization transfer imaging (MT) in detecting metabolic and structural changes of renal fibrosis in rats with unilateral ureteral obstruction (UUO) at 3T MRI. Materials and Methods: Thirty-five Sprague-Dawley rats underwent UUO surgery (n = 25) or sham surgery (n = 10). The obstructed and contralateral kidneys were evaluated on days 1, 3, 5, and 7 after surgery. After CEST and MT examinations, 18F-labeled fluoro-2-deoxyglucose positron emission tomography was performed to quantify glucose metabolism. Fibrosis was measured by histology and western blots. Correlations were compared between asymmetrical magnetization transfer ratio at 1.2 ppm (MTRasym(1.2ppm)) derived from CEST and maximum standard uptake value (SUVmax) and between magnetization transfer ratio (MTR) derived from MT and alpha-smooth muscle actin (α-SMA). Results: On days 3 and 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of contralateral kidneys (p < 0.05). On day 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of sham-operated kidneys (p < 0.05). The MTRasym(1.2ppm) of UUO renal medulla was fairly negatively correlated with SUVmax (r = -0.350, p = 0.021), whereas MTR of UUO renal medulla was strongly negatively correlated with α-SMA (r = -0.744, p < 0.001). Conclusion: CEST and MT could provide metabolic and structural information for comprehensive assessment of renal fibrosis in UUO rats in 3T MRI and may aid in clinical monitoring of renal fibrosis in patients with chronic kidney disease.

새로운 자기공명영상촬영용 Quadrature Breast RF 코일 (A New Quadrature Breast RF Coil for MRI)

  • 김선경;양윤정;이덕래;이윤;안창범;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.291-293
    • /
    • 1997
  • A new quadrature RF coil is designed for Breast MR Imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by "$\sqrt{2}$" using two orthogonal RF coils in combination. A modified Breast Quadrature coil is designed. It is a modified type of the high-pass birdcage coil. To reduce the field distortion, by using current feeding, the field pattern is optimized to achieve a quadrature circularly-polarized field pattern. The coil has been implemented for receive-only mode, and tested by phantom imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

Dixon 정량 화학적 변위 자기공명영상을 이용한 척추 골수 지방함량과 이중에너지 방사선 흡수법의 BMD 값의 비교 (Correlation Between Vertebral Marrow Fat Fraction Measured Using Dixon Quantitative Chemical Shift MRI and BMD Value on Dual-energy X-ray Absorptiometry)

  • 윤인영;이화연;김재균
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.16-24
    • /
    • 2012
  • 목적: Dixon 정량 화학적 변위 자기공명영상(QCSI)의 척추 골수 지방함량과 이중에너지 방사선 흡수법 (DXA)를 통한 BMD 값과의 상관성을 알아본다. 대상과 방법: QCSI와 간의 화학적 변위영상을 포함한 전신 자기공명영상(MRI)과 요추의 DXA를 시행한 68명의 건강한 사람들[평균연령, 50.7세; 범위, 25-76세; 남/여=36/32]을 대상으로 후향적 연구를 시행하였다. 성별과 T-score에 따라 정상(남/여=27/23)과 골감소증(남/여=9/9)집단으로 나누고, MRI로 척추골수와 간의 지방함량을 측정하였다. 각 집단의 나이, 체질량지수(BMI), 골수 지방함량과 간의 지방함량을 비교하였고, 여성에서는 폐경 전후 각 변수들의 비교를 추가하여 Spearman's 상관계수로 평가하였다. 결과: 남성의 나이, BMI, 척추 골수와 간의 지방함량은 정상과 골감소증 집단 사이에 큰 차이를 보이지 않았다. 여성에서는, 골감소증 집단의 평균 나이가 정상집단에 비해 높았고(p=0.01), 폐경된 경우가 많았으나[폐경 전, 26.1%(6/23); 후, 77.8%(7/9); p<0.05], 다른 변수들은 유의한 차이를 보이지 않았다. 골수 지방함량과의 비교에 있어 여성의 나이는 유일한 의미 있는 변수였다(r=0.43, p<0.05). 결론: Dixon QCSI를 통한 척추 골수 지방함량의 측정은 남녀 모두에 있어 DXA BMD 감소를 정확히 반영하지는 않는다.

Synthesis and Magnetic Relaxation Properties of Paramagnetic Gd-complexes of New DTPA-bis-amides. The X-ray Crystal Structure of [Gd(L)(H2O)]·3H2O (L = DTPA-bis(4-carboxylicphenyl)amide)

  • Dutta, Sujit;Kim, Suk-Kyung;Lee, Eun-Jung;Kim, Tae-Jeong;Kang, Duk-Sik;Chang, Yong-min;Kang, Sang-Ook;Han, Won-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권7호
    • /
    • pp.1038-1042
    • /
    • 2006
  • A new type of DTPA-bis-amides (L1-L4) and their Gd(III)-complexes of the type $[Gd(L)(H_2O)]{\cdot}nH_2O$ (5: L1; 6: L2; 7: L3; 8: L4) have been prepared and characterized by analytical and spectroscopic techniques. The X-ray crystal structure of 8 has been determined for structural confirmation. The coordination geometry adopts a tricapped trigonal prism geometry with L4 acting as a chelate octadentate and a water molecule in the coordination sphere. Crystals are monoclinic, $P2_1$, a = 14.468(3), b = 19.235(4), c = 13.527(2) $\AA$ $\beta$ = $107.245(3)^{\circ}$, V = 3595.2(11) $\AA^3$, Z = 4, $D_{calc}$ = 1.570. Significant increases in relaxivities are observed with 6 and 7 as compared with that of $Omniscan^{(R)}$, a commercial MR agent: R1 = 12.46 $mM^{-1}\;s^{-1}$, R2 = 8.76 $mM^{-1}\;s^{-1}$ for 6; R1 = 12.77 nm-1 s-1, R2 = 7.60 mM-1 s-1 for 7; R1 = 4.9 $mM^{-1}\;s^{-1}$, R2 = 4.8 $mm^{-1}\;s^{-1}$ for $Omniscan^{(R)}$. In the case of 5, however, both R1 and R2 are found to be lower to show 2.09 $mM^{-1}\;s^{-1}$, and 1.82 $mM^{-1}\;s^{-1}$, respectively.

선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가 (Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array)

  • 이동훈;홍철표;한봉수;김형진;서재준;김소현;이춘형;이만우
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가 (Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering)

  • 성열훈;주용현;임재동;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.208-215
    • /
    • 2009
  • 2차원의 영상을 이용한 돌출형 전립선 비대증의 부피 평가방법에서 돌출부위를 포함시킬 경우와 포함시키지 않을 경우의 부피변화를 3차원 볼륨 렌더링(volume rendering, VR)을 이용하여 비교 평가하고자 한다. 돌출형 전립선 부피측정을 위한 가상 전립선 모델은 곤약을 이용해 임의로 평균 1 cm 정도로 돌출되도록 하여 10 ml에서 각각 10 ml씩 부피를 변화시켜 100 ml까지 총 10 개의 모델을 제작하였다. 이 때 제작된 모델의 부피측정은 64 channel 전산화단층촬영(computed tomography, CT)과 3.0 Tesla 자기공명영상(magnetic resonance image, MRI)을 이용하여 획득된 3차원 볼륨 영상자료로 계측하였다. 산출한 CT와 MRI영상들의 3차원 볼륨데이터 근접성 평가를 위해 wilcoxon 부호순위(signed rank) 검정을 하였다. 또한 획득한 영상자료는 3차원 영상처리를 통하여 볼륨 렌더링으로 재구성한 후 타원체부피공식법을 이용하여 돌출부위를 포함시킬 때와 포함하지 않을 때의 부피를 구하였다. 이 때 돌출 유무에 따라 각각 측정된 부피와 3차원 볼륨 렌더링의 부피를 wilcoxon 부호순위(signed rank) 검정을 사용하여 유의성을 평가했으며 상관계수(pearson's correlation coefficient, r)를 사용하여 상관관계를 분석하였다. 계측된 가상 전립선 모델의 돌출부위길이는 CT에서 $0.90{\pm}0.18\;mm$, MRI에서 $0.75{\pm}0.11\;mm$이었으며, CT와 MRI에서 계측된 3차원 영상 부피의 p-value는 0.414로 유의한 차이는 없었다. 그러나 MRI에서 측정된 3차원 영상 부피와 2차원 영상에서 돌출부위를 포함시킬 때의 p-value는 0.005인 반면 포함하지 않을 때의 p-value는 0.139로 나타났으며, CT에서도 측정된 3차원 영상 부피와 2차원 영상에서 돌출부위를 포함시킬 때의 p-value는 0.005인 반면 포함하지 않을 때의 p-value는 0.057로 나타났다. 돌출형 전립선의 부피측정은 돌출부위를 제외하고 상하길이를 측정하는 것이 3차원 볼륨 렌더링에 의한 부피 값과 더 가까운 부피 값을 얻을 수 있었다.

  • PDF