• Title/Summary/Keyword: R-test

Search Result 10,487, Processing Time 0.039 seconds

Influence of Self-Efficacy and Social Support on Test Anxiety among Nursing Students Taking the National Examination for Registered Nurses (국가고시를 앞둔 간호대학생의 자기효능감과 사회적지지가 시험불안에 미치는 영향)

  • Noh, Yoon Goo;Lee, Young Sook
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.633-643
    • /
    • 2016
  • This study was designed to examine the effects of self-efficacy and social support on test anxiety among nursing students taking the National Examination for Registered Nurses. A convenience sample of 212 nursing students was obtained from three nursing colleges. Data were collected by a self-administered questionnaire during December 2015. Data were analyzed using descriptive statistics, t-test, one-way ANOVA, $Scheff{\acute{e}}$ test, Pearson correlations and multiple regression with SPSS/WIN 18.0. The mean score for test anxiety was located in the middle range, with the score of $2.84{\pm}0.53$; those for self-efficacy and social support were located higher in the 1-5 scale, each scoring $3.50{\pm}0.54$ and $3.72{\pm}0.48$. Test anxiety correlated negatively with self-efficacy (r=-.32, p<.001), social support (r=-.27, p<.001), friends support (r=-.21, p=.002), family support (r=-.25, p<.001) and professor support (r=-.14, p=.038). Self-efficacy, family support and gender explained 13.0% of participants' test anxiety (F=11.01, p<.001). Findings from this study suggests that improving the self-efficacy and family support will be helpful for nursing students to relieve their test anxiety.

Evaporation Heat Transfer and Pressure Drop of Mixture Refrigerant R-407C (혼합냉매 R-407C의 증발 열전달과 압력강하)

  • Roh, Geon-Sang;Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.542-549
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in a horizontal copper tube were investigated experimentally. The main components of the refrigerant loop are a receiver, a compressor, a mass flow meter, a condenser and a double pipe type evaporator (test section). The test section consists of a smooth copper tube of 6.4 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300\;kg/m^2s$ and the saturation temperature of evaporator were $5^{\circ}C$. The evaporation heat transfer coefficients of R-22 and R-407C increase with the increase of mass flux and vapor quality. The evaporation heat transfer coefficients of R-22 is about $5.68{\times}46.6%$ higher than that of R-407C. The evaporation pressure drop of R-22 and R-407C increase with the increase of mass flux. The pressure drop of R-22 is similar to that of R-407C. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of R-22 and R-407C. therefore, it is necessary to develope reliable and accurate predictions determining the evaporation heat transfer coefficient of R-22 and R-407C in a horizontal tube.

Validation of new saliva test using SALIgAE® (사건현장 검사를 위해 변형된 SALIgAE® 타액검사법의 유효성 검토)

  • Lim, Si-Keun;Kwak, Kyung-Don;Choi, Dong-Ho;Han, Myun-Soo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.48-52
    • /
    • 2008
  • A new forensic saliva test method using $SALIgAE^{(R)}$ was evaluated in this study. The sensitivity and specificity of $SALIgAE^{(R)}$ were examined and compared to those of other saliva test methods such as agarose gel diffusion method and $Phadebas^{(R)}$ test sheet method. $SALIgAE^{(R)}$ showed high sensitivity and specificity to human saliva in addition to quickness. Moreover modified $SALIgAE^{(R)}$ method was cheap and easy to use in crime scene and DNA laboratory. $SALIgAE^{(R)}$ was very stable at room temperature and had no effect on STR typing.

A Method of Reliability Growth Management Test Design for Continuous System (연속형 시스템의 신뢰성 성장 관리 시험 설계 방안)

  • Seo, Yang Woo;Yoon, Jung Hwan;Lee, Seung Sang;Um, Chun Sup
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.87-96
    • /
    • 2020
  • In this paper we proposed the test design method of reliability growth management. First, we presented the process for establishing the reliability growth management test design considering the number of failures and the termination test time. Reliability growth analysis of continuous system was performed in accordance with the test design process presented. In case the reliability test result is not met with the reliability target value after more than three failures occurred, the required test times were analyzed that 1,725 hrs for one corrective action, 1,950 hrs for two corrective actions. If the number of failures is less than three, design a reliability demonstration test according to confidence level 80% and 90% was performed using RGA 11 Software. As a result, it is possible to establish the reliability growth management test design with sufficient use of available resources. The results of this study can be used when establishing a test design for assessment of reliability growth management of all continuous systems.

Distributed Translator Part 2: Laboratory Test Results (분산 중계기 Part 2: 실험실 테스트 결과)

  • Park, Sung-Ik;Eum, Ho-Min;Seo, Jae-Hyun;Kim, Heung-Mook;Lee, Soo-In
    • Journal of Broadcast Engineering
    • /
    • v.15 no.1
    • /
    • pp.29-39
    • /
    • 2010
  • This paper presents and analyzes laboratory test results of distributed translator (DTxR) for distributed frequency network (DFN) in the ATSC (Advanced Television Systems Committee) terrestrial digital TV broadcasting system. The DTxR laboratory test is classified to receiving part test and transmitting part test. The receiving part test includes dynamic range, random noise, single echo, and adjacent channel interference. The transmitting part test includes quality of output signal (out-of channel emission, quality of transmitting signal, and phase noise), frequency synchronization among output signals, and TxID (Transmitter Identification) signal's affect to the legacy receiver. By the laboratory test results, the receiving part of DTxR eliminates average -2.5 dB of single echo and has average 17.5 dB at TOV (Threshold of Visibility) under random noise environment. In addition, the transmitting part of DTxR satisfies the specification of US FCC (Federal Communications Commission), and frequency difference among DTxR output signals is less than 0.001 Hz.

A Study on the Test & Evaluation Process of Civil Aircraft for Compliance (적합성 입증을 위한 민항기 시험평가 절차 연구)

  • Kim, Kwang Hae;Choi, Nag Sun;Koh, Dae Woo
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.6 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The Test and Evaluation (T&E) process is an integral part of the Systems Engineering Process. The purpose of Test and Evaluation (T&E) in a system development is to identify the areas of risk to be reduced or eliminated. In this study, when develop aircraft of Civil Aviation with development experience of Military Aircraft, it is that establish Test and Evaluation process. Test and Evaluation for KC-100 small aircraft development can divide to certification test and development test. Certification test is proved compliance about Korea Airworthiness standard (KAS Part 23), through Development Test verify required performance of aircraft. These Test and Evaluation Process is more efficient and optimized.

  • PDF

Dynamic Characteristics Test and Test Model Establish on Double Circuit for Protective Relay Test Using Real Time Digital Simulator (송전선보호계전기 시험을 위한 RTDS센서의 2회선 송전선로 Model구축 및 동특성시험)

  • Jung, Chang-Ho;Lee, Jae-Gyu;Yoon, Nam-Seon;Ahn, Bok-Shin;Kim, Sok-Il
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1038-1040
    • /
    • 1997
  • This paper describes dynamic characteristics test of distance relay and current differential relay using Real Time Digital Simulator on double circuit transmission line. First, The double circuit T/L modeling on RTDS was proposed and the results from the proposed model were compared with those of PSS/E. This comparison shows the possibility of dynamic test using the RTDS. The relay included about 20 test items which are apt to include maloperation of protective relays in critical situations.

  • PDF

Performance Evaluation of HFO-1234yf as a substitute for R-134a in a Household Freezer/Refrigerator (HFO-1234yf를 적용한 가정용 냉동/냉장고의 성능평가)

  • Lee, Jang-Seok;Han, Jun-Soo;Lee, Myung-Ryul;Jeon, Si-Moon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.7
    • /
    • pp.743-748
    • /
    • 2011
  • The performance of HFO-1234yf as a substitute for R-134a was evaluated in a household freezer/refrigerator. A series of tests such as 'refrigerant charging test, pull-down test, cooling speed test, and energy consumption test were carried out under the AHAM (Association of Home Appliance Manufacturers) standard. The results of a drop-in test were compared with those of a test conducted using R-134a. A test under a severe ambient air condition ($43^{\circ}C$) was also conducted. The result shows that the refrigeration cycle performance of HFO-1234yf is as good as that of R-134a ; however, the diameter of capillary tube should be increased in order to improve its performance in the cooling speed test.

Degradation Damage Evaluation for Turbine Structural Components by Electrochemical Reactivation Polarization Test (전기화학적 재활성화 분극시험에 의한 터빈부재의 열화손상 평가)

  • Kwon, Il-Hyun;Baek, Seung-Se;Lyu, Dae-Young;Yu, Hyo-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1241-1249
    • /
    • 2002
  • The extent of materials deterioration can be evaluated accurately by mechanical test such as impact test or creep test. But it is almost impossible to extract a large test specimen from in-service components. Thus material degradation evaluation by non-destructive method is earnestly required. In this paper, the material degradation for virgin and several aged materials of a Cr-Mo-V steel, which is an candidated as structural material of the turbine casing components for electric power plant, is nondestructively evaluated by reactivation polarization testing method. And, the results obtained from the test are compared with those in small punch(SP) tests recommended as a semi-nondestructive testing method using miniaturized specimen. In contrast to the aged materials up to 1,000hrs which exhibit the degradation behaviors with increased ${\Delta}[DBTT]_{SP}$, the improvement of mechanical property can be observed on the 2,000hrs and 3,000hrs aged materials. This is because of the softening of material due to the carbide precipitation, the increase of ferritic structures and the recovery of dislocation microstructure by long-time heat treatment. The reactivation rates($I_R/I_{Crit},\;Q_R/Q_{Crit}$) calculated by reactivation current densityt ($I_R$) and charge($Q_R$) in the polarization curves exhibit a good correlation with ${\Delta}[DBTT]_{SP}$ behaviors.

Evaluation of sperm DNA fragmentation using multiple methods: a comparison of their predictive power for male infertility

  • Javed, Aamir;Talkad, Muralidhar Srinivasaih;Ramaiah, Manjula Kannasandra
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.46 no.1
    • /
    • pp.14-21
    • /
    • 2019
  • Objective: The usual seminal profile has been customarily used for diagnosing male infertility based on an examination of semen samples. However, sperm DNA fragmentation has also been causally linked to reproductive failure, suggesting that it should be evaluated as part of male infertility assessments. To compare the ability of the five most widely utilized methodologies of measuring DNA fragmentation to predict male infertility and reactive oxygen species by Oxisperm kit assay. Methods: In this case-control study, which received ethical committee approval, the participants were divided into fertile and infertile groups (50 patients in each group). Results: The alkaline comet test showed the best ability to predict male infertility, followed by the terminal deoxynucleotidyl transferase dUTP nick end labelling (TUNEL) assay, the sperm chromatin dispersion (SCD) test, and the sperm chromatin structure assay (SCSA), while the neutral comet test had no predictive power. For our patient population, the projected cut-off point for the DNA fragmentation index was 22.08% using the TUNEL assay, 19.90% using SCSA, 24.74% using the SCD test, 48.47% using the alkaline comet test, and 36.37% using the neutral comet test. Significant correlations were found between the results of the SCD test and those obtained using SCSA and TUNEL (r = 0.70 and r = 0.68, respectively; p< 0.001), and a statistically significant correlation was also found between the results of SCSA and the TUNEL assay (r = 0.77, p< 0.001). Likewise, the results of the alkaline comet test showed significant correlations with those of the SCD, SCSA, and TUNEL tests (r = 0.59, r = 0.57, and r = 0.72, respectively; p< 0.001). Conclusion: The TUNEL assay, SCSA, SCD, and the alkaline comet test were effective for distinguishing between fertile and infertile patients, and the alkaline comet test was the best predictor of male infertility.