• Title/Summary/Keyword: R-test

Search Result 10,543, Processing Time 0.045 seconds

The Effect of Massage Therapy and Exercise Therapy on Body Composition and Blood Cholesterol in the Obese women (마사지 요법과 운동요법이 비만여성의 신체조성과 혈중 콜레스테롤에 미치는 영향)

  • Lee, Mi-Shun;Han, Mi-Jung;Lee, Young-Shun
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.2 no.1 s.1
    • /
    • pp.93-102
    • /
    • 2004
  • The purpose of this study is to examine the effect of massage therapy and exercise therapy on body composition and blood cholesterol in the obese women. Sixteen college women were randomly assigned to aged $20.1{\pm}2.7$ years who had not exercised regurlarly, volunteered to participate in the present study as subjects. They completed a 12 weeks massage therapy and exercise therapy performed 3 times/week, for 60min/session. Massage put in exercise treatment effect of 12 weeks in BMI has shown a significant decrease those are before test $25.1{\pm}2.2$ to after test $23.7{\pm}3.2$(p<0.05). The waist measure/height has a difference by before test r=0.5 to after a test r=0.47, and waist measure/hips measure by before test r=0.8 to after test r=0.75. A total cholesterol(TC) average value has $187.6{\pm}36.9$ before test to $168{\pm}32.4$(p<0.05) after test, a significant difference. Also average value of LDLC has $114{\pm}33.8$ before test to $99.2{\pm}30.4$(p<0.05) that shows a difference, but HDLC was $52{\pm}7.5$ before test to $52.3{\pm}7.7$(p<0.05) after test which means a none difference. HDLC does not have any difference but total cholesterol and LDLC were significantly different. It was a short program of 3 times a week, 60 min/session but, a dance meditation exercise program with high strength self massage had given a big effect in consideration. Using these scientific studies data, wish a program related by obese could make an activation in a beauty part.

  • PDF

A Study on the Drop-in Tests of a Small Ice Maker Using R-404A Replacements R-448A and R-449A (소형 제빙기에 사용되는 R-404A 대체 R-448A, R-449A의 Drop-in Test에 대한 연구)

  • Lee, Byungmoo;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • R-404A, which is used widely in small-scale ice makers, is scheduled to be phased out because of its high global warming potential. In this study, drop-in tests were conducted using R-448A and R-449A, which replace R-404A, to modify the outdoor air and supply water temperatures. The results showed that the daily ice production rate of R-404A was 5.3% higher than that of R-448A and 4.2% higher than that of R-449A. This was attributed to the larger vapor density of R-404A, which resulted in a larger mass flow rate in the system. Between R-448A and R-449A, R-448A yielded a larger amount of ice at low air and water temperatures, whereas R-449A yielded a larger amount of ice at high air and water temperatures. The daily power consumption of R-404A was approximately 10% larger than those of R-448A and R-449A. The resulting COPs of R-448A and R-449A was similar, only 3.0% larger than that of R-404A. The literature survey showed that the condensation or evaporation data of R-448A or R-449A are very limited, and research on this issue is recommended.

The Condensation Pressure Drop of R-22 and R-410A in Small Diameter Tube (세관내 R-22와 R-410A의 응축 압력강하)

  • Son, Chang-Hyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.2
    • /
    • pp.156-162
    • /
    • 2008
  • The condensation pressure drop for R-22 and R-410A flowing in a small diameter tube was investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and coolant flowing in the annulus. The test section consists of 1220 mm length with horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes ranged from 450 to $1050\;kg/m^2{\cdot}s$ and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main experimental results were summarized as follows : In the case of two-phase flow, the pressure drop increases with increasing mass flux and decreasing quality. The pressure drop of R-22 is slightly higher than that of R-410A for the same mass flux. Most of correlations proposed in the large diameter tube showed enormous deviations with experimental data.

Condensing Heat Transfer Characteristics of Propylene Refrigerant (프로필렌 냉매의 응축열전달 특성에 관한 실험적 연구)

  • 이호생;김재돌;윤정인
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.7
    • /
    • pp.639-644
    • /
    • 2004
  • This paper deals with the heat transfer characteristics of R-1270 (Propylene), R-600a (Iso-butane) and R-290 (Propane) as an environment friendly refrigerant and R-22 for condensing. The experimental apparatus has been set-up as a conventional vapor compression type heat pump system. The test section is a horizontal double pipe heat exchanger. A tube diameter of 12.70 mm with 1.32 mm wall thickness is used for this investigation. The test results showed that the local condensing heat transfer coefficients of hydrocarbon refrigerants were higher than that of R-22. The average condensing heat transfer coefficient was obtained with the maximum value in R-1270 and the minimum one in R-22. Comparing the heat transfer coefficient of experimental results with that of other correlations, the presented results had a good agreement with the Cavallini-Zecchin's correlation. It reveals that the natural refrigerants can be used as substitute for R-22.

Usefulness of the Milk Ring Test for the Diagnosis of Brucellosis in Dairy Cattle (유우(乳牛)브루셀라병(病) 진단(診斷)을 위(爲)한 Milk Ring Test의 이용가치(利用價値))

  • Chung, Byung Tack
    • Korean Journal of Veterinary Research
    • /
    • v.9 no.2
    • /
    • pp.55-59
    • /
    • 1969
  • For the establishment of simpler and more reliable methods for the diagnosis of Brucellosis, diagnostic antigen for Milk Ring Test (M.R.T.) was prepared according to working document recommended by Ministry of Agriculture U.S.A., and applied in the field for the test of its's applicability. The results are summarized as follows. 1. Of fifty two dairy cattle ranches in the vicinity of Seoul, five ranges were shown positive reaction to M.R.T. 2. Even though one volume of positive milk was mixed with five to ten volumes of negative milk, the positive reactions were also observed. 3. Antigenicity of the antigen was maintained without deteriolation for 13 months at $5^{\circ}C$ and three months at both $22^{\circ}C$ and $37^{\circ}C$. 4. Three positive cows to M.R.T. were also shown suspective reaction by Serum Agglutination Test.

  • PDF

An experimental investigation of thermodynamic performance of R-22 alternative blends (R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구)

  • Hwang, E.P.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF

Comparative study in fracture strength of zirconia cores fabricated with three different CAD/CAM systems (3종의 CAD/CAM 시스템에서 지르코니아 코어의 파절 강도에 관한 비교 연구)

  • Shin, Eon-Sick;Lee, Young-Soo;Park, Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.22-30
    • /
    • 2008
  • Purpose: The purpose of this study is to compare three different CAD/CAM systems through the fracture strength of zirconia core and to evaluate the clinical availability of each system. Material and methods: The following three groups of 30 maxillary mesial incisor core for all-ceramics(each group 10) were fabricated as follows: group 1. $Adens^{(R)}$ CAD/CAM system, group 2. $Cerasys^{(R)}$ CAD/CAM system, group 3. 3M $Lava^{(R)}$ CAD/CAM system. All specimens were manufactured consistently thickness 0.5mm and relief $40{\mu}m$. Specimens were subjected to compressive loading on the lingual area by Z250/$SN5S^{(R)}$. Each group's mean and standard deviation were calculated and Kruskal Waillis test, Wilcoxon Rank Sum test were utilized to find out the relationship among the groups. Results: The results were as follows: 1. The mean fracture strength of $Adens^{(R)}$ system was $615.89{\pm}156.1N$, the $Cerasys^{(R)}$ system was $863.98{\pm}151.5N$, and the 3M $Lava^{(R)}$ system was $1143.1{\pm}286.6N$. 2. The fracture strength of the systems showed the significant statistical differences in order of 3M $Lava^{(R)}$ system, $Cerasys^{(R)}$ system, $Adens^{(R)}$ system. Conclusion: In this study, in spite of the differences among the groups, every group showed clinically useful results. It is necessary to study further clinical experiments on a long term basis.

A Comparison of Flow Condensation HTCs of R22 Alternatives in the Multi-Channel Tube (다채널 알루미늄 평판관내 R22와 R134a의 흐름 응축 열전달 성능 비교)

  • 서영호;박기정;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.589-598
    • /
    • 2004
  • Flow condensation heat transfer coefficients (HTCs) of R22 and R134a were measured on a horizontal 9 hole aluminum multi-channel tube. The main test section in the refrigerant loop was made of a flat multi-channel aluminum tube of 1.4 mm hydraulic diameter and 0.53 m length. Refrigerant was cooled by passing cold water through an annulus surrounding the test section. Data were obtained in the vapor qualities of 0.1∼0.9 at mass flux of 200∼400 kg/$m^2$s and heat flux of 7.3∼7.7 ㎾/$m^2$ at the saturation temperature of 4$0^{\circ}C$. All popular correlations in single-phase subcooled liquid and flow condensation originally developed for large single tubes predicted the present data of the flat tube within 20% deviation when effective heat transfer area is used in determining experimental data. This suggests that there is little change in flow characteristics and patterns when the tube diameter is reduced down to 1.4 mm diameter range. Thermal insulation for the outer tube section surrounding the test tube for the transport of heat transfer fluid is very important in fluid heat-ing or cooling type heat transfer experimental apparatus.

Characteristics of Undrained Shear Behavior for Nak-Dong River Sand Due to Aging Effect (Aging 효과에 따른 낙동강 모래의 비배수 전단거동 특성)

  • Kim, Young-Su;Kim, Dae-Man
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.916-923
    • /
    • 2005
  • In this study, to observe aging effect of undrained shear behavior for Nak-Dong River sand, undrained static and cyclic triaxial tests were performed with changing relative density ($D_r$), consolidation stress ratio($K_c$) and consolidation time. As a result of the test, the modulus of elasticity to all samples estimated within elastic zone by the micro strain of about 0.05% in case of static shear behavior increased with the lapse of consolidation time significantly, so aging effect was shown largely. Also strength of phase transformation point(S_{PT}$) and strength of critical stress ratio point($S_{CSR}$) increased with the lapse of consolidation time. Undrained cyclic shear strength($R_f$) obtained from the failure strain 5% increased in proportion to relative density($D_r$) and initial static shear stress($q_{st}$), $R_f$ of consolidated sample for 1,000 minutes increased about 10.6% compared to that for 10 minutes at the loose sand, and $R_f$ increased about 7.0% at the medium sand. In situ application range of $R_f$ to the magnitude of earthquake for Nak-Dong River sand was proposed by using a increasing rate of $R_f$ as being aging effect shown from this test result.

  • PDF

Design of Radio Frequency Test Set for TC&R RF Subsystem Verification of LEO and GEO Satellites (저궤도 및 정지궤도위성의 TC&R RF 서브시스템 검증을 위한 RF 시험 장비 설계)

  • Cho, Seung-Won;Lee, Sang-Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.674-682
    • /
    • 2014
  • Radio Frequency Test Set (RFTS) is essential to verify Telemetry, Command & Ranging (TC&R) RF subsystem of both Low Earth Orbit (LEO) and Geostationary Earth Orbit (GEO) satellite during Assembly Integration & Test (AI&T). The existing RFTS was specialized for each project and needed to be modified for each new satellite. The new design enables RFTS to be used in various projects. The hardware and software was designed considering this and therefore it could be directly used in other projects within a similar test period without modification or inconvenience. It will be also easily controlled, modified, and managed through the extension in modularization according to each function and the use of COTS (commercial on-the-self) and this will improve system reliability. A more reliable RF test measurement is also provided in this new RFTS by using an accurate reference clock signal.