• Title/Summary/Keyword: R-peak

Search Result 1,518, Processing Time 0.03 seconds

A Study on the Measurement of the Transformation Fraction of Steel Using an Eddy Current Sensor (와전류 방식에 의한 금속변태율 측정에 관한 연구)

  • Lee, J.R.;Peak, K.N.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.325-326
    • /
    • 1989
  • His paper is concerned on the measurement of transformation fraction of steel using an eddy current sensor. Four stainless duplex samples with different transformation fraction are made and electromagnetic characteristics of the samples are measured.

  • PDF

Development of Zygotic Embryos and Seedlings is Affected by Radiation Spectral Compositions from Light Emitting Diode (LED) System in Chestnut (Castanea crenata S. et Z.)

  • Park, So-Young;Kim, Man-Jo
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.5
    • /
    • pp.750-754
    • /
    • 2010
  • Among the environmental conditions employed in micropropagation, light quality plays an important role in growth, specially morphogenesis and photosynthesis. The effect of radiation quality (350-740 nm) on the development and growth of zygotic embryos and in vitro plantlets of open-pollinated chestnut (Castanea crenata S. et Z.) were studied. Two types of explants were exposed for 4 weeks to cool white (W, as control), monochromatic red (R, peak emission 650 nm), monochromatic blue (B, peak emission 440 nm), red+blue (R+B, 1:1), or red+far-red (R+Fr, 1:1, far-red peak emission 720 nm) radiation from a light-emitting-diode (LED) system. While the zygotic embryos showed positive photoblastic behavior, their germination was inhibited by blue radiation. Hypocotyl elongation and root development were promoted by red radiation. The emergence of primary leaf and its expansion were faster under blue than under red radiation. In the plantlets, red and red+far-red radiation significantly increased the formation and growth of the root, whereas blue light reduced rooting. Therefore, radiation quality appears to influence some steps in the development of zygotic embryos and plantlets in the chestnut.

Property of molecular beam epitaxy-grown ZnSe/GaAs (분자선 에피성장법으로 성장된 ZnSe/GaAs의 특성)

  • Kim, Eun-Do;Son, Young-Ho;Cho, Seong-Jin;Hwang, Do-Weon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.2
    • /
    • pp.52-56
    • /
    • 2007
  • We have installed an ultra high vacuum (UHV) molecular beam epitaxy (MBE) system and investigated into the characteristics of MBE-grown ZnSe/GaAs [001] using scanning electron microscopy (SEM), atomic force microscopy (AFM), we confirmed that layer's surface was dense and uniform of molecular layer. We used x-ray diffractometer (XRD) and confirmed two peaks correspond to GaAs [001] substrate and ZnSe epilayer, respectively. We observed photoluminescence (PL) peak approximately at 437 nm and measured PL mapping of 2 inch ZnSe epilayer.

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • v.7 no.3
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

Measurement of cardiac output during treadmill exercise by impedance cardiography with a new ensemble average (새로운 앙상블 평균법에 의한 임피던스 심장기록법의 트래드밀 운동 중의 심박출량 측정)

  • Kim, Deok-W.;Song, Chul-G.;Oh, In-S.;Hwang, Soo-K.;Kim, Won-K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.05
    • /
    • pp.7-8
    • /
    • 1990
  • In this study, a new ensemble average technique was developed to measure cardiac output during treadmill exercise. Each dZ/dt peak (C point) was used as a starting point for ensemble averaging, instead of conventionally used R wave of ECG in order to prevent the peak dZ/dt waveform from blurring. In ease of using R wave as a reference, time interval from R wave to the peak of dZ/dt varies for each heart beat. Stroke volume, heart rate, and cardiac output of five male were successfully measured with Balke protocol using the new ensemble average technique.

  • PDF

Thermally Assisted Carrier Transfer and Field-induced Tunneling in a Mg-doped GaN Thin Film (Mg가 첨가된 GaN 박막에서 캐리어 전이의 열적도움과 전계유도된 터러링 현상)

  • Chung, Sang-Geun;Kim, Yoon-Kyeom;Shin, Hyun-Gil
    • Korean Journal of Materials Research
    • /
    • v.12 no.6
    • /
    • pp.431-435
    • /
    • 2002
  • The dark current and photocurrent(PC) spectrum of Mg-doped GaN thin film were investigated with various bias voltages and temperatures. At high temperature and small bias, the dark current is dominated by holes thermally activated from an acceptor level Al located at about 0.16 eV above the valence band maximum $(E_v)$, The PC peak originates from the electron transition from deep level A2 located at about 0.34 eV above the $E_v$ to the conduction band minimum $(E_ C)$. However, at a large bias voltage, holes thermally activated from A2 to Al experience the field-in-duces tunneling to form one-dimensional defect band at Al, which determines the dark current. The PC peak associated with the transition from Al to $E_ C$ is also observed at large bias voltages owing to the extended recombination lifetime of holes by the tunneling. In the near infrared region, a strong PC peak at 1.20 eV appears due to the hole transition from deep donor/acceptor level to the valence band.

Study of the Impulse Wave Impinging upon an Inclined Flat Plate (경사판에 충돌하는 펄스파에 관한 연구)

  • Kweon, Y.H.;Lee, D.H.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.438-443
    • /
    • 2001
  • Plate impingement of the impulse wave discharged from the open end of a duct is numerically investigated using a CFD method. Harten-Yee Total Variation Diminishing method is used to solve the unsteady, compressible flow governing equations. The Mach number, the flat plate inclination and the distance between the duct exit and inclined flat plate are changed to investigate their effects on the impinging flow field. The impulse wave impingement on the inclined flat plate depends on Mach number $M_s$ and the plate inclination $\psi$. The pressure distributions on the inclined flat plate show that for a small r/D, the peak pressure at the center of an inclined flat plate decreases with an increase in the plate inclination $\psi$ in the range of $\psi$ from $45^{\circ}$ to $60^{\circ}$ but for a large r/D, the peak pressure decreases with an increase in $\psi$ in the range of $\psi$ from $75^{\circ}$ to $90^{\circ}$. It is also found that for all of r/D, the peak pressure at the center of an inclined flat plate has a maximum value in $\psi=90^{\circ}$.

  • PDF

THE RELATIONSHIP BETWEEN BUFFER INDEX CURVE AND FERMENTATION QUALITY OF SILAGE

  • Kim, K.H;Uchida, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.1
    • /
    • pp.67-71
    • /
    • 1991
  • The purpose of this study was to investigate the possibility of using the buffer index curve as a criterion of silage quality evaluation. The buffer index (or buffer capacity, $\beta$) value is the amount of 0.1N NaOH consumed in titrating from the beginning to the end of the chosen pH step. This value equals the slope of the titration curve at the chosen pH range (${\beta}={\Delta}NaOH/{\Delta}pH$). There were two patterns of buffer index curve. Poorly preserved silages had a peak at pH 5.0, whereas with well preserved silages the peaks tended to rise to the pH 3.75 or 4.00. Well preserved, wilted silages with high pH also appeared to have peak values at pH 3.75 or 4.00. There was a high positive correlationship between the concentration of lactic acid and peak value of good quality silage (r = 0.994, p < 0.01). Also a high positive correlationship (r = 0.899, p < 0.001) was found between the sums of concentration of acetic and butyric acids and the peak values of poor quality silages. The results of these experiments verified the value of the buffer index method as a criterion of silage quality evaluation.

Isolation of the Anti-tumor Promoters from Citrus Peels (감귤과피로부터 발암 promotion 억제활성성분의 분리)

  • Yoon, Chang-Hoon;Jwa, Seung-Mi
    • Applied Biological Chemistry
    • /
    • v.49 no.1
    • /
    • pp.25-29
    • /
    • 2006
  • This study was carried out to isolate the possible anti-tumor promoters from the citrus peel (Citrus natsudaidai Hayata). We fractionated the cold-pressed oil of citrus peel by column chromatography, HPLC and TLC. The analysis on column chromate-graphy yielded seven peaks $(F-I{\sim}F-VII)$, all of which showed single spot on TLC analysis ($R_f$ for $F-I{\sim}VIII$; 0.31, 0.13, 0.13, 0.78, 0.79, 0.69 and 0.84). Among the seven fractions, three fractions (F-I, -II and F-IV) were re-analyzed on HPLC, also showing single peak except for one fraction (F-IV) which was divided two peaks. The retention times $(R_f)$ of F-I and F-II was 3 min. and 2.5 min., respectively, but these of two peaks from F-IV were 2 min. and 4.5 min., respectively. Since the area of the latter peak (4.5 min.) was very smaller than that of the former one (2 min.), it is considered that the latter one did not appear on TLC analysis. The inhibitory effect on tumor promoter 12-O-tetradecanoylphorbol-13-acetate(TPA)-induced Epstein-Barr virus activation in Raji cells was tested for the seven fraction obtained. It decreased in order of F-VI (82.3+1.3%) > F-I (80.4+1.6%) > F-II (77.2+0.9%) > F-III (75.0+1.2%) > F-IV (74.1=1.0%) > F-V (71.0+1.1%) > F-VII (70.2+1.2%). These results imply that some constiuents contained in citrus peels have the inhibitory activity of TPA-induced tumor promotion.

Stability of Triamcinolone Added in Three Oral Liquid Syrups (경구용 시럽제 중 Triamcinolone의 안정성 연구)

  • Yoon, Hee-Young;Lee, Byung-Koo;Gwak, Hye-Sun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.2
    • /
    • pp.176-180
    • /
    • 2012
  • The stability of triamcinolone in three kinds of oral liquid syrups at 4 and $25^{\circ}C$ was studied for 21 days. Twenty tablets of 4 mg triamcinolone were mixed with 100 mL of each oral liquid syrup, which is Levotuss$^{(R)}$Syrup (levodropropizine 6 mg/mL), Ucerax$^{(R)}$Syrup (hydroxyzine 2 mg/mL), and Xyzal$^{(R)}$Liquid (levocetirizine 0.5 mg/mL). The chromatographic analysis after deliberate degradation showed no evidence of any breakdown product likely to interfere with the chromatographic peak of the parent substance. The relationship between triamcinolone concentrations and peak areas was linear from 50 to 1000 ${\mu}g/mL$ ($r^2$ = 0.9998). The analysis method was precise, with coefficients of variation no greater than 5.4%. Triamcinolone was stable for up to 14 and 21 days in Levotuss$^{(R)}$Syrup at 25 and $4^{\circ}C$, respectively; in Ucerax$^{(R)}$Syrup and Xyzal$^{(R)}$Syrup, it was stable for at least 21 days at both temperatures. The percentages of initial triamcinolone concentration remaining after 21 days were $72.3{\pm}3.2$ and $94.9{\pm}6.0%$ and $93.2{\pm}4.9$ and $92.4{\pm}5.7%$, and $92.6{\pm}1.2$ and $92.7{\pm}2.2%$ in Levotuss$^{(R)}$Syrup, Ucerax$^{(R)}$Syrup, and Xyzal$^{(R)}$Syrup at 25 and $4^{\circ}C$, respectively. The pH variations of all test solutions were within 0.8. Based on the results, it was concluded that triamcinolone in three oral liquid syrups which are Levotuss$^{(R)}$syrup, Ucerax$^{(R)}$syrup and Xyzal$^{(R)}$syrup was chemically and physically stable in both states of refrigeration and room temperature for at least 14 days.