• Title/Summary/Keyword: R-Curve

Search Result 1,706, Processing Time 0.027 seconds

Determination of bromate in bottled mineral water in Korea (먹는 샘물 중 bromate 분석 및 분포 특성)

  • Ahn, Hye-Sil;Kim, Hyun-Koo;Park, Ju-Hyun;Jung, Dong-Il;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • This study was performed to compare international analytical methods of bromate and applied to determine bromate in bottled mineral water in Korea. Bromate in bottled mineral water was eluted by 10~50 mM potassium hydroxide (KOH) and determined by ion chromatograph-suppressed conductivity detector (ICCD). Sample was purified with on guard Ba-, Ag- and H-cartridges and $0.2\;{\mu}m$ membrane filter. The method detection limit (MDL) and the limit of quantitation (LOQ) of bromate were 0.1 and $0.5\;{\mu}g/L$, respectively. The calibration curve showed good lineality above 0.9998 in the ranges of the $0.5\sim40\;{\mu}g/L$. Bromate from 33 samples among total 157 bottled mineral water samples was detected in the concentration range of $0.5\sim6.5\;{\mu}g/L$. The detected concentrations were within bottled mineral water quality criteria ($10\;{\mu}g/L$) in Korea.

Magnetic Properties of Ti0.96Co0.02Fe0.02O2 (Ti0.96Co0.02Fe0.02O2의 자기적 특성)

  • Kim, E.C.;Lee, S.R.;Kim, S.J.;Han, G.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.43-46
    • /
    • 2007
  • The samples were synthesized by using a solid state reaction. The X-ray diffraction pattern for $Ti_{0.96}Co_{0.02}Fe_{0.02}O_2$ showed a pure rutile phase with tetragonal structures. Mixtures of the proper proportions of the elements sealed in evacuated quartz ampoule were heated at $870{\sim}930^{\circ}C$ for one day and then slowly cooled down to room temperature at a rate of $10^{\circ}C/h$. In order to obtain single phase material, it was necessary to grind the sample after the first firing and to press the powders into pellets before annealing them for a second time in evacuated and sealed quartz ampoule. Magnetic properties have been investigated using the vibrating sample magnetometer(VSM). Room temperature magnetic hysteresis(M-H) curve showed an obvious ferromagnetic behavior and the magnetic moment per Fe atom under the applied of 0.8T was estimated to be about $1.3{\mu}_B/CoFe$. But the magnetic moment per Fe atom under the applied of 0.8T was estimated to be about $0.02{\mu}_B/CoFe$ without Ti-getter.

Age and Growth of the Short Necked Ruditapes philippinarum on the South Coast of Korea (한국 남해안 바지락, Ruditapes philippinarum의 연령과 성장)

  • Yoon, Ho-Seop;An, Yun-Keun;Kim, Sun-Tak;Choi, Sang-Duk
    • The Korean Journal of Malacology
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • Age and growth of the short-necked, Ruditapes philippinarum were collected from Goheung coast in Korea. Relative growth equations among SL, SH, SW and TW of Ruditapes philippinarum were ranged from 0.8059 to 0.8859. The ring radius were estimated from a von Bertalanffy method with the values of $SL_{1.58}=12.51{\pm}2.55\;mm$, $SL_{2.58}=20.27{\pm}3.08\;mm$, $SL_{3.58}=26.90{\pm}2.49\;mm$, $SL_{4.58}=31.35{\pm}3.62\;mm$, $SL_{5.58}=35.45{\pm}3.54\;mm$, $SL_{6.58}=38.78{\pm}4.04\;mm$. Back calculated total weight at the formation of annual ring on the shell of Ruditapes philippinarum with the values $TW_{1.58}$=0.35 g, $TW_{2.58}$ = 4.62 g, $TW_{3.58}$ = 5.84 g, $TW_{4.58}$ = 6.71 g, $TW_{5.58}$ = 7.50 g, $TW_{6.58}$ = 8.14 g. Growth curves for shell height and total weight fitted to the von Bertalanffy equation were expressed as: $SL_t= 51.01(1-e^{-0.1738(t+1.07)})$ $TW_t = 11.65(1-e^{-0.1738(t+1.07)})^{2.9519}$.

The evaluation on the biological safety of diagnostic ultrasound using radiation-induced apoptosis in the external granular layer of mouse cerebellum (마우스 소뇌과립층의 apoptosis를 지표로 한 진단용 초음파의 안전성 검증)

  • Oh, Heon;Lee, Song-eun;Yang, Jung-ah;Jo, Sung-kee;Chung, Chi-young;Son, Chang-ho;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.628-634
    • /
    • 1999
  • We have studied, by a nonisotopic in situ end-labeling(ISEL) technique, frequency of apoptosis in the external granular layer(EGL) of the cerebellum of immature mice by ${\gamma}$-rays irradiation from $^{60}Co$ or diagnostic ultrasound exposure. The total number of normal cells and cells showing morphological features of apoptosis were counted. The frequency of apoptotic cells was expressed as a percentage of the total number of cells in EGL. The extent of changes following 200 cGy(1090 cGy/min) was studied at 2, 4, 6, 8, 12, or 24 hours after exposure. The maximal frequency was found 6~8 hours after exposure. The immature mice that received 18, 36, 54, 108, 198, 396 cGy of ${\gamma}$-rays or diagnostic ultrasound(7.5MHz, 4.2mW, $I_{SPTA}=7.9mW/cm^2$, $I_{SPTA}=114.3W/cm^2$) for 10 or 30 minutes were examined 6 hours after irradiation. Measurements performed after ${\gamma}$-ray irradiation showed a dose-related increase in apoptotic cells in each of the mice studied. The dose-response curves were analyzed by a linear-quadratic model ; frequency of apoptotic cell in the EGL was y = $(0.1349{\pm}0.01175)D$+$(-0.0001522{\pm}0.0000334)D^2$+0.048($r^2$ = 0.981, D = dose in cGy). In the experiment of ultrasound exposure, the frequency of apoptotic cell was $0.106{\pm}0.130$(10 minutes exposure) and $0.167{\pm}0.220$(30 minutes exposure). We estimated the relative dose of the yield from the experiment with ultrasound by substituting the yield from ultrasound exposure into the curve from the ${\gamma}$-irradiation. The relative dose of ultrasound exposure compared with ${\gamma}$-irradiation were 0.432 cGy(10 minutes exposure) and 0.885 cGy(30 minutes exposure). We have found that there is no evidence to indicate that diagnostic ultrasound involves a significant risk.

  • PDF

A Developmont of Numerical Mo del on the Estimation of the Log-term Run-off for the Design of Riverheads Works -With Special Reference to Small and Medium Sijed Catchment Areas- (제수원공 설계를 위한 장기간 연속수수량 추정모형의 개발 - 중심유역을 중심으로)

  • 엄병현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.4
    • /
    • pp.59-72
    • /
    • 1987
  • Although long-term runoff analysis is important as much as flood analysis in the design of water works, the technological level of the former is relatively lower than that of the latter. In this respect, the precise estimation model for the volume of successive runoff should he developed as soon as possible. Up to now, in Korea, Gajiyama's formula has been widely used in long-term runoff analysis, which has many problems in applying in real situation. On the other hand, in flood analysis, unit hydrograph method has been exclusively used. Therefore, this study aims at trying to apply unit hydrograph method in long-term runoff analysis for the betterment of its estimation. Four test catchment areas were selected ; Maesan area in Namlum river as a representative area of Han river system, Cheongju area in Musim river as one of Geum river system, Hwasun area in Hwasun river as one of Yongsan river system, and Supyung area in Geum river as one of Nakdong river system. In the analysis of unit hydrograph, seperation of effective rainfall was carried out firstly. Considering that effective rainfall and moisture condition of catchrnent area are inside and outside of a phenomenon respectively and the latter is not considered in the analysis, Initial base flow(qb)was selected as an index of moisture condition. At the same time, basic equation(Eq.7) was established, in which qb can take a role as a parameter in relating between cumulative rainfall(P) and cumulative loss of rainfall(Ld). Based on the above equation, computer program for estimation model of qbwas seperately developed according to the range of qb, Developed model was applied to measured hydrographs and hyetographs for total 10 years in 4 test areas and effective rainfall was estimated. Estimation precision of model was checked as shown in Tab- 6 and Fig.8. In the next stage, based on the estimated effective rainfall(R) and runoff(Qd), a runoff distribution ratio was calculated for each teat area using by computerised least square method and used in making unit hydrographs in each test area. Significance of induced hydrographs was tested by checking the relative errors between estimated and measured runoff volume(Tab-9, 10). According to the results, runoff estimation error by unit hydrograph itself was merely 2 or 3 %, but other 2 or 3 % of error proved to be transferred error in the seperation of effective rainfall. In this study, special attentioning point is that, in spite of different river systems and forest conditions of test areas, standardized unit hydrographs for them have very similar curve shape, which can be explained by having similar catchinent characteristics such as stream length, catchinent area, slope, and vegetation intensity. That fact should be treated as important factor ingeneralization of unit hydrograph method.

  • PDF

Validation of Analytical Method of Marker Compounds in Extract of Pear Pomace as a Functional Health Ingredient (건강기능식품 원료로서 나주 배박 추출물의 지표성분 분석법 벨리데이션)

  • Cho, Eun-Jung;Bang, Mi-Ae;Cho, Seung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.11
    • /
    • pp.1682-1686
    • /
    • 2015
  • This study was conducted to establish an HPLC analysis method for determination of marker compounds as part of materials standardization for development of health functional food materials from pear pomace. The quantitative determination method of caffeic acid and chlorogenic acid as marker compounds of pear pomace extract (PPE) was optimized by HPLC analysis using a C18 column ($5{\times}250mm$, $5{\mu}m$) with a 0.2% elution gradient of acetic acid and methanol as the mobile phase at a flow rate of 0.8 mL/min and detection wavelength of 330 nm. The HPLC/UV method was applied successfully to the quantification of marker compounds in PPE after validation of the method with linearity, accuracy, and precision. The method showed high linearity of the calibration curve with a coefficient of correlation ($R^2$) of 0.9999, and limit of detection and limit of quantification were $1.14{\mu}g/mL$ (caffeic acid) and $1.61{\mu}g/mL$ (chlorogenic acid) as well as $4.9{\mu}g/mL$ (caffeic acid) and $4.9{\mu}g/mL$ (chlorogenic acid), respectively. Relative standard deviation values from intra- and inter-day precision were less than 3.1% (caffeic acid) and 4.0% (chlorogenic acid), respectively. Recovery rates of caffeic acid and chlorogenic acid at 12.5, 25, and $50{\mu}g/mL$ were 93.66~106.32% and 97.33~105.68%, respectively. An optimized method for extraction of caffeic acid and chlorogenic acid in PPE was established through diverse extraction conditions, and the validation indicated that the method is very useful for evaluation of marker compounds in PPE to develop a health functional food material.

A Linear Change of Leakage Current and Insulation Resistance of 22 kV Cables (22 kV 케이블의 누설전류 및 절연저항의 선형적 변화)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.169-173
    • /
    • 2015
  • This study is to predict the life exponent by measuring, over 7 years, the insulation resistance of high-voltage cables in 22 kV operation for 13 years. We found out the lifetime index in order to determine the time-dependent trend of deteriorating performance of power cables. The insulation resistances decreased according to elapsed time. We found that: the initial measurements of the cable systems were in agreement with the deterioration properties of the Arrhenius Law. By analyzing the life curve of the cable system, we also verified that the value of the life exponent (n) in the v-t characteristics defined by Weibull distribution has values from 10 to 11. When designing the cable system, the initial value of life exponent was chosen as 9 without any grounding. We have verified that the theoretical grounding based on the design safety of n=9 was actually the best one available. In the short term, we apply our research result to the diagnosis and evaluation of the power cables. In the long run, however, we plan to reduce the cost of the installation and management of cable systems in operation at power stations.

Catalpol Content and Antioxidant Activities in Various Cultivars of Rehmannia glutinosa (품종별 지황의 Catalpol 함량 및 항산화능)

  • You, Bo-Ram;Kim, Hye-Ran;Kim, Hyo-Jin;Lee, Ji-Yeon;Lee, Sang-Yong;Song, Mi-Ran;Park, Jong -Yoon;Kim, Mee-Ree
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.4
    • /
    • pp.481-485
    • /
    • 2011
  • This study was to investigate catalpol content and antioxidant activities in five cultivars (Kokang, Suwon 10, Suwon 11, Jiwhang 1 and Korea) of Rehmannia Radix. Catalpol content was analysed by HPLC using $C_{18}$ column ($150{\times}4.6\;mm$, $5{\mu}m$), 1% acetonitrile and a UV detector. The standard curve was found to be a linear regression of y=0.0483x-0.0841 ($R^2$=0.999). The catalpol content ranged from 85.2 mg/g to 144.9 mg/g, of which the Korea was the highest among cultivars. The total phenol content in Rehmannia Radix was 0.358~0.459 mg/g, of which the Korea was the highest among cultivars. The antioxidant activities determined by DPPH and hydroxyl radical scavenging activities were the highest in Korea with $IC_{50}$ of 205.8 mg/g for DPPH radical scavenging activity and $IC_{50}$ of 38.8 mg/g for hydroxyl radical scavenging activity. Based on these results, the Korea among Rehmannia Radix cultivars was suggested to be a potent medicinal plant material for antioxidant activities.

A Stability Analysis of Geosynthetics Reinforced Soil Slopes I. - Slope Stability Analysis Considering Reinforcing Effects - (토목섬유 보강 성토사면의 안정해석 I. - 보강효과를 고려한 사면안정해석 -)

  • Kim Kyeong-Mo;Kim Hong-Taek;Lee Eun-Soo;Kim Young-Yoon;Ahn Kwang-Kuk
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.8
    • /
    • pp.95-105
    • /
    • 2005
  • Generally, a modified version of limit equilibrium method can be used to evaluate a slope stability of the geosynthetic reinforced soil slopes. In most cases, resisting effects of geosynthetic reinforcement are dealt with considering an increased shear strength on the potential slip surface. However, it is not clear that the methods satisfy all three equilibrium equations. As we know, the pattern of normal stress distribution along the slip surface is the key factor in calculating the safety factor of slopes. In this study, the new slope stability analysis method in which not only reinforcing effects of geosynthetics can be considered but also all three equilibrium equations can be satisfied was proposed with assuming the normal stress distribution along the slip surface as quadratic curve with horizontal $\chi-coordinate$. A number of illustrative examples, including published slope stability analysis examples for the reinforced and unreinforced soil slopes, loading test of large scale reinforced earth wall and centrifuge model tests on the geotextile reinforced soil slopes, were analyzed. As a result, it is shown that the newly suggested method yields a relatively accurate factor of safety for the reinforced and unreinforced soil slopes.

The Review of Optimum Level of SDR in Empirical Soil Erosion Model (경험적 토사유실모형에서 SDR의 적정성 검토)

  • Lee, Geun-Sang;Park, Jin-Hyeog;Lee, Eul-Rae;Hwang, Eui-Ho;Chae, Hyo-Sok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.774-778
    • /
    • 2010
  • Upland erosion pollutes surface waters and often causes serious problems when deposition occurs. This study builds a sediment rating curve using the measured sediment yield and the simulated soil erosion by a GIS-embedded empirical model. The coefficient of determination ($R^2$) between the simulated soil erosion and the measurement sediment yields with rainfall amount are 0.427 for Donghyang and 0.667 for Cheonchen, but the values with rainfall intensity are 0.873 and 0.927 respectively. The data are divided into two groups: one for calibration during 2002-2005 (48 months) and the other for estimation during 2006-2008 (36 months). The first data group (2002-2005) was used to derive the SDR with an aid of soil erosion calculated by the USLE and the measured sediment yield. The mean SDR with rainfall amount is 6.273 and 3.353, respectively, while 4.799 and 2.874 for rainfall intensity. But the standard deviation (STD) with rainfall intensity is 0.930 and 0.407, which is much less than that with rainfall amount (3.746 and 2.090) for both sites. The results show the derived SDR provides reasonable accuracy and rainfall intensity gives better performance in calculating soil erosion than rainfall amount.

  • PDF