• Title/Summary/Keyword: R-BENCH

Search Result 77, Processing Time 0.023 seconds

Prediction of the Transient Performance of the Passenger Diesel Engine with Turbocharger using HIL (HIL을 이용한 터보과급기 승용 디젤 엔진의 과도 성능 예측)

  • Chung, Jin-Eun;Jin, Young-Wook;Jeong, Dong-Young;Chung, Jae-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.127-132
    • /
    • 2009
  • The transient performance of the passenger diesel engine equipped with the variable geometry turbocharger was simulated using HIL(hardware-in-the-loop) system. The system consists of engine model as software, and the turbocharger test bench as hardware. The engine model is mean value model which is programmed by the Simulink of the Mathworks. The turbocharger test bench is composed of a blower, some sensors, and DAQ boards. A real time simulation is possible since the operating system based on the real time is included. The results show the good response for the transient characteristics. Therefore this HIL system can be used for development of the new turbocharger effectively.

A Performance Modeling of the Lean NOx Trap Catalyst with GT-POWERTM (GT-POWERTM를 이용한 Lean NOx Trap 촉매 성능 모델링)

  • Kim, Hyunjun;Han, Manbae;Jeon, Ji-Yong;Kim, Tae-Min
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.6
    • /
    • pp.64-71
    • /
    • 2013
  • In this study we designed a lean $NO_x$ trap (LNT) model with $GT-POWER^{TM}$ program and then the LNT model was compared to the bench flow reactor test results. This model consists of 9 kinetic reactions to represent the main steps of NO oxidation, $NO_x$ adsorption, $NO_x$ release and then its reduction. The comparison was performed on the operating conditions at the space velocity of 50,000 1/hr and 80,000 1/hr with the temperature range of $200^{\circ}C{\sim}500^{\circ}C$ with the even spaced temperature step of $50^{\circ}C$. The experimental results show that the $NO_x$ conversion efficiency was enhanced by the temperature up to $350^{\circ}C$ and then decayed at higher temperatures. The LNT model predicts the similar trend of the $NO_x$ conversion efficiency to the experimental results below $350^{\circ}C$, but overestimates above $350^{\circ}C$. This overestimation comes from the higher reduction efficiency which was obtained by the different reduction gas composition such as $C_3H_6$ in the model to replace $CH_4$, $C_2H_4$ in the bench test.

A Study on the Fluid H in Automotive Air Conditioning System as an Alternative Refrigerant (자동차 공조용 대체 냉매로서의 H냉매에 대한 연구)

  • Choi, Jeong-Won;Nam, Soo-Byeong;Bang, Scott
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.6
    • /
    • pp.170-176
    • /
    • 2007
  • It is time to prepare the phaseout of R134a, the current refrigerant, in automotive air conditioning system because the EC deadline has been coming with new platform vehicles in 2011 and all vehicles by 2017. Until now a high-pressure carbon dioxide($CO_2$) system is the leading replacement of R134a in European auto-makers but there is no firm agreement in the world automotive market. Recently three new fluids have been announced as the possibilities from Honeywell, DuPont and INEOS Fluor. The new alternative refrigerant should meet the requirements like non flammable, non toxic, no ozone depletion effect and low GWP(under 150 to meet EC regulation). The objectives of this paper are to review the fluid H from Honeywell, the more possible alternative refrigerant in 3 new fluids, compare the properties of R134a & fluid H and see the possibility as a replacement of R134a. In this experimental paper we ran and reviewed the cooling performance data in the bench system, the vehicle and the field test. We found the possibility of fluid H system to meet the R134a system performance with some hardware modifications but agreed that it is still needed to study about the long term safety, environmental effects, material compatibilities and so on.

A Study on the Development of Ship's Stern Tube Sealing System(II) -Based on Face Seals- (선미관 밀봉장치의 개발에 관한 연구 (II) -풰이스 시일을 중심으로-)

  • 김영식;전효중;왕지석;김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.47-54
    • /
    • 1991
  • The lip seals widely used nowadays in stern tube sealing system of ships have radial sealing contact with shafts or liners, on the other hand the face seals of stern tube sealing system have axial sealing contact with seat. Because of axial sealing contact, the face seals have a large number of merits such as durability of life, simplicity of structure, easy fitting and replacement, etc. In this paper, for the purpose of development of face seals, the fundamental properties of axial sealing contact were analyzed and a trial face seal was designed and manufactured using N.B.R. rubber and Thordon which is widely used for bearing materials. The seal proper of trial face seal was made from N.B.R. rubber and the face insert was made from Thordon, thermosetting resins which are three dimensional, cross linked condensation polylmers. The performance test of trial face seal was carried out on the test bench which was specially designed and manufactured. The results were satisfactory enough to be used in practical stern tube sealing system.

  • PDF

Classification of Pathological Voice from ARS using Neural Network (신경회로망을 이용한 ARS 장애음성의 식별에 관한 연구)

  • Jo, C.W.;Kim, K.I.;Kim, D.H.;Kwon, S.B.;Kim, K.R.;Kim, Y.J.;Jun, K.R.;Wang, S.G.
    • Speech Sciences
    • /
    • v.8 no.2
    • /
    • pp.61-71
    • /
    • 2001
  • Speech material, which is collected from ARS(Automatic Response System), was analyzed and classified into disease and non-disease state. The material include 11 different kinds of diseases. Along with ARS speech, DAT(Digital Audio Tape) speech is collected in parallel to give the bench mark. To analyze speech material, analysis tools, which is developed local laboratory, are used to provide an improved and robust performance to the obtained parameters. To classify speech into disease and non-disease class, multi-layered neural network was used. Three different combinations of 3, 6, 12 parameters are tested to obtain the proper network size and to find the best performance. From the experiment, the classification rate of 92.5% was obtained.

  • PDF

Performance of HCFC22 Alternatives R1270, R290, R1270/R290, R290/HFC152a, R1270/R290/RE170 Refrigerants for Air-conditioning and Heat Pump Applications (HCFC22 대체 R290, R1270 및 R1270/R290, R290/HFC152a, R1270/R290/RE170 혼합냉매의 공기조화기와 열펌프 작동범위에서의 성능 평가)

  • Hwang Ji-Hwan;Baek In-Cheol;Jung Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.312-319
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons and 7 mixtures was measured in an attempt to substitute HCFC22 used in air-conditioners and heat pumps. The mixtures were composed of R1270 (propylene), R290 (propane), HFC152a, and RE170 (Dimethyl ether, DME). The pure and mixed refrigerants tested have GWPs of $3{\sim}58$ as compared to that of $CO_2$ and the mixtures are all near-azeotropic showing the gliding temperature difference (GTD) of less than $0.6^{\circ}C$. Thermodynamic cycle analysis was carried out to determine the optimum compositions and actual tests were performed in a laboratory heat pump test bench at the evaporation and condensation temperatures of 7.5 and $45.1^{\circ}C$ respectively. Test results show that the coefficient of performance (COP) of these mixtures is up to 5.7% higher than that of HCFC22. While propane showed 11.5% reduction in capacity, most of the fluids tested had the similar capacity to that of HCFC22. Compressor discharge temperatures were reduced by $11{\sim}17^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 55% as compared to HCFC22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for. residential air-conditioning and heat pumping application.

Performance of HFC32/HFC125 Mixtures for Heat Pumps (HFC32/HFC125 혼합냉매의 히트펌프 성능 평가)

  • Kim, Wook-Jin;Kang, Dong-Gyu;Lee, Yo-Han;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.791-798
    • /
    • 2011
  • In this study, performance of R410A(50%R32/50%R125) and HFC32/HFC125 mixture is measured to examine the effect of composition shift of R410A used for various air-conditioners and heat pumps. The composition of HFC32/HFC125 mixture varies from the reference composition of R410A ${\pm}10%$ with 5% interval. Tests carried out in a heat pump bench tester at the evaporation and condensation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ for summer and winter conditions, respectively. Test results show that both the coefficient of performance (COP) and compressor power of the HFC32/HFC125 mixture have the maximum difference of 2.0% as compared to those of R410A. Compressor discharge temperatures of HFC32/HFC125 mixture are increased up to $6.7^{\circ}C$ as compared to that of R410A. The amount of charge for HFC32/HFC125 mixture vary within 5.6% as compared to that of R410A. Overall, performance of R410A is not appreciably affected by the composition shift of ${\pm}10%$ of R32 under both air-conditioning and heat pumping conditions.

Effects of Refrigerant Oils and Molecular Sieve on Air Conditioner using Alternative Refrigerant (대체냉매를 사용한 에어콘에서 합성오일과 건조제(M/S)의 영향)

  • Choa, S.H.;Hong, C.K.;Kim, C.K.;Yoon, B.;Kang, S.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.473-483
    • /
    • 1996
  • To protect the ozone layer, R22 will be replaced with HFCs. R407C is a leading candidate as alternative refrigerant for air conditioner due to its similar thermodynamic characteristics with R22. In replacing R22 with R407C, the compatibility with lubricating oil is of major concern. Polyol ester (POE) oil among the synthetic oils is considered to be the best lubricant for use with R407C because of good electrical properties and miscibility. However, lubricating ability of mixture of R407C/POE oil is lower than that of R22/mineral oil due to the production of acid by hydrolysis which causes corrosive wear. Therefore, to minimize water content, it is needed to develop a molecular sieve desiccant which is compatible with R407C and ester oil. This paper discusses (1) the change of properties of POE oil when current molecular seive is used, (2) the effects of POE oils and additives on durability of compressor. Through compressor life test and bench wear test, it was found that inadequate use of POE oils and additives may promote the deteriation of molecular sieve, resulting in decrease of durability of compressor.

  • PDF

Prefix Cuttings for Packet Classification with Fast Updates

  • Han, Weitao;Yi, Peng;Tian, Le
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.4
    • /
    • pp.1442-1462
    • /
    • 2014
  • Packet classification is a key technology of the Internet for routers to classify the arriving packets into different flows according to the predefined rulesets. Previous packet classification algorithms have mainly focused on search speed and memory usage, while overlooking update performance. In this paper, we propose PreCuts, which can drastically improve the update speed. According to the characteristics of IP field, we implement three heuristics to build a 3-layer decision tree. In the first layer, we group the rules with the same highest byte of source and destination IP addresses. For the second layer, we cluster the rules which share the same IP prefix length. Finally, we use the heuristic of information entropy-based bit partition to choose some specific bits of IP prefix to split the ruleset into subsets. The heuristics of PreCuts will not introduce rule duplication and incremental update will not reduce the time and space performance. Using ClassBench, it is shown that compared with BRPS and EffiCuts, the proposed algorithm not only improves the time and space performance, but also greatly increases the update speed.

Modeling of nonlinear response of R/C shear deficient t-beam subjected to cyclic loading

  • Hawileh, R.A.;Abdalla, J.A.;Tanarslan, M.H.
    • Computers and Concrete
    • /
    • v.10 no.4
    • /
    • pp.419-434
    • /
    • 2012
  • This paper presents a finite element (FE) model for predicting the nonlinear response and behavior of a reinforced concrete T-beam deficient in shear under cyclic loading. Cracking loads, failure loads, response hysteresis envelopes and crack patterns were used as bench mark for comparison between experimental and FE results. A parametric study was carried out to predict the optimum combination of the open and close crack shear transfer coefficients (${\beta}_t$ and ${\beta}_c$) of the constitutive material model for concrete. It is concluded that when both shear transfer coefficients are equal to 0.2 the FE results gave the best correlation with the experimental results. The results were also verified on a rectangular shear deficient beam (R-beam) tested under cyclic loading and it is concluded that the variation of section geometry has no effect on the optimum choice of the values of shear transfer coefficients of 0.2. In addition, a parametric study based on the variation of concrete compressive strength, was carried out on the T-beam and it is observed that the variation of concrete compressive strength has little effect on the deflection. Further conclusions and observations were also drawn.