• Title/Summary/Keyword: R wave amplitude

Search Result 75, Processing Time 0.025 seconds

PVC Classification by Personalized Abnormal Signal Detection and QRS Pattern Variability (개인별 이상신호 검출과 QRS 패턴 변화에 따른 조기심실수축 분류)

  • Cho, Ik-Sung;Yoon, Jeong-Oh;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1531-1539
    • /
    • 2014
  • Premature ventricular contraction(PVC) is the most common disease among arrhythmia and it may cause serious situations such as ventricular fibrillation and ventricular tachycardia. Nevertheless personalized difference of ECG signal exist, performance degradation occurs because of carrying out diagnosis by general classification rule. In other words, the design of algorithm that exactly detects abnormal signal and classifies PVC by analyzing the persons's physical condition and/or environment and variable QRS pattern is needed. Thus, PVC classification by personalized abnormal signal detection and QRS pattern variability is presented in this paper. For this purpose, we detected R wave through the preprocessing method and subtractive operation method and selected abnormal signal sets. Also, we classified PVC in realtime through QS interval and R wave amplitude. The performance of abnormal beat detection and PVC classification is evaluated by using MIT-BIH arrhythmia database. The achieved scores indicate the average of 98.33% in abnormal beat classification error and 94.46% in PVC classification.

A Study on the Development of R-R Interval Analyzer using Microcomputer (1) (Microcomputer를 이용한 R-R Interval Analyzer 개발에 관한 연구 (1))

  • Lee, Joon-Ha;Choi, Soo-Bong
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.77-80
    • /
    • 1985
  • The R-R interval analyzer was developed to measure the autonomic nervous system function using microcomputer. The system based on 8 bit microcomputer including bandpass filter, R-wave detector and clock generator in order to obtain the mean value, standard deviation, total time, CV value, maximum value and minimum value in the specific view point of R-R interval variation. The pattern of R-R interval change after resting, voluntary standing and deep breathing can be analysed in normal subjects and diabetics with autonomic nervous dysfunction. The amplitude of the R-R interval variation showed sensitive pattern for normal subjects at resting, standing and deep breathing. On the contrary, the periodicities of amplitude for abnormal subjects with autonomic nervous dysfunction showed dull pattern. It was suggested that R-R interval analyzer is a good detection method for dysfunction of autonomic nervous system.

  • PDF

Studies on the Electrocadiogram in Non-human Primates Reared in Korea (國內 飼育 원숭이의 心電圖에 관한 硏究)

  • 서진석;서지민;이버들;송근호;이수진;김덕환;현병화;신남식
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Non-human primates are widely used for experimental animal and raised as companion animal in Korea. To establish the electrocadiogram (ECG) of non-human primates that are domestically raised, the author measured bipolar limb leads and augmented unipolar limb leads, after tiletamine/zolazepam (TZ) injection as sedative agents. The amplitudes of P,Q, R,S and T wave and duration time of P wave, QRS complex, PR and QT interval in each lead of ECG were evaluated in 7 non-human primates at 15 minutes after TZ injection, respectively. The amplitude of P wave in I, II,III, aVR, aVL and aVF leads revealed 0.06$\pm$ 0.05,0.14$\pm$ 0.05, 0.1 $\pm$ 0.05,-0.11 $\pm$ 0.06,-0.04$\pm$ 0.04 and 0.12$\pm$ 0.05 mV respectively. The amplitude of Q wave revealed -0.16$\pm$ 0.15, -0.23$\pm$ 0.18, -0.17$\pm$ 0.13, 0.16$\pm$0.13, 0.04$\pm$ 0.09 and -0.2$\pm$0.13 mV, respectively. The amplitude of R wave revealed 0.56$\pm$0.56, 1.24$\pm$ 0.67, 0.92$\pm$0.33, -0.37$\pm$ 1.14, -0.22$\pm$ 0.47 and 1.12 $\pm$ 0.47 mV, respectively. The amplitude of S wave revealed -0.02$\pm$ 0.08, -0.04$\pm$0.06, -0.06$\pm$0.04, 0.02$\pm$0.04, 0.04$\pm$0.09 and -0.04 $\pm$ 0.06 mV, respectively. The amplitude of T wave revealed -0.01 $\pm$ 0.15,-0.02$\pm$ 0.13, 0.01 $\pm$ 0.08, 0.02$\pm$ 0.12, 0.01 $\pm$ 0.11 and -0.03$\pm$ 0.09 mV, respectively. The duration time of P wave revealed 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.02, 0.05 $\pm$ 0.02, 0.04$\pm$ 0.01 and 0.04$\pm$ 0.01 sec, respectively. The duration time of QRS complex revealed 0.05 $\pm$ 0.02,0.05$\pm$ 0.01, 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.01 and 0.05 $\pm$ 0.01 sec, respectively. The duration time of PR interval revealed 0.08$\pm$ 0.01, 0.07$\pm$0.01,0.08$\pm$ 0.03, 0.08$\pm$0.01, 0.08$\pm$ 0.01 and 0.08$\pm$0.01 sec, respectively. The duration time of QT interval revealed 0.23$\pm$ 0.06, 0.22$\pm$ 0.05, 0.23 $\pm$ 0.06, 0.23$\pm$ 0.06, 0.24$\pm$ 0.05 and 0.22$\pm$ 0.02 sec, respectively. No significant changes were observed in e amplitude of P and T waves. The amplitude of QRS complex in ketamine group was higher than that of TZ group. However, no significant changes were observed in both intra-group and inter-group. There were no significant changes in the duration time of P wave, QRS complex and PR interval obtained from both groups. Also, the duration time of QT interval in TZ group was significantly longer at 30 min.(P< 0.05) an that of 10 minutes after injection. However, significant difference was not found between two groups. The mean cardiac electric axis in ketamine group tended to decrease until 30 min. after injection and then gradually increase. However, mean cardiac electric axis of TZ group was increased until 30 min. after injection and then decreased. But significant differences were not observed between groups. These results suggest that the ECG pattern after TZ injection to non-human primates reared in korea was established. It was also considered that the injection of ketamine and TZ didn't significantly affect on ECG pattern of the non-human primates.

Response of square tension leg platforms to hydrodynamic forces

  • Abou-Rayan, A.M.;Seleemah, Ayman A.;El-Gamal, Amr R.
    • Ocean Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.115-135
    • /
    • 2012
  • The very low natural frequencies of tension leg platforms (TLP's) have raised the concern about the significance of the action of hydrodynamic wave forces on the response of such platforms. In this paper, a numerical study using modified Morison equation was carried out in the time domain to investigate the influence of nonlinearities due to hydrodynamic forces and the coupling effect between surge, sway, heave, roll, pitch and yaw degrees of freedom on the dynamic behavior of TLP's. The stiffness of the TLP was derived from a combination of hydrostatic restoring forces and restoring forces due to cables and the nonlinear equations of motion were solved utilizing Newmark's beta integration scheme. The effect of wave characteristics such as wave period and wave height on the response of TLP's was evaluated. Only uni-directional waves in the surge direction was considered in the analysis. It was found that coupling between various degrees of freedom has insignificant effect on the displacement responses. Moreover, for short wave periods (i.e., less than 10 sec.), the surge response consisted of small amplitude oscillations about a displaced position that is significantly dependent on the wave height; whereas for longer wave periods, the surge response showed high amplitude oscillations about its original position. Also, for short wave periods, a higher mode contribution to the pitch response accompanied by period doubling appeared to take place. For long wave periods, (12.5 and 15 sec.), this higher mode contribution vanished after very few cycles.

Tethers tension force effect in the response of a squared tension leg platform subjected to ocean waves

  • El-gamal, Amr R.;Essa, Ashraf;Ismail, Ayman
    • Ocean Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.327-342
    • /
    • 2014
  • The tension leg platform (TLP) is one of the compliant structures which are generally used for deep water oil exploration. With respect to the horizontal degrees of freedom, it behaves like a floating structure moored by vertical tethers which are pretension due to the excess buoyancy of the platform, whereas with respect to the vertical degrees of freedom, it is stiff and resembles a fixed structure and is not allowed to float freely. In the current study, a numerical study for square TLP using modified Morison equation was carried out in the time domain with water particle kinematics using Airy's linear wave theory to investigate the effect of changing the tether tension force on the stiffness matrix of TLP's, the dynamic behavior of TLP's; and on the fatigue stresses in the cables. The effect was investigated for different parameters of the hydrodynamic forces such as wave periods, and wave heights. The numerical study takes into consideration the effect of coupling between various degrees of freedom. The stiffness of the TLP was derived from a combination of hydrostatic restoring forces and restoring forces due to cables. Nonlinear equation was solved using Newmark's beta integration method. Only uni-directional waves in the surge direction was considered in the analysis. It was found that for short wave periods (i.e., 10 sec.), the surge response consisted of small amplitude oscillations about a displaced position that is significantly dependent on tether tension force, wave height; whereas for longer wave periods, the surge response showed high amplitude oscillations that is significantly dependent on wave height, and that special attention should be given to tethers fatigue because of their high tensile static and dynamic stress.

Voltage Amplitude Control of Square-Wave VSIs with an R-L Load (R-L부하를 가진 구형파 VSI의 전압크기 제어)

  • Kim Kyung-Won;Hong Soon-Chan;Yoo Jong-Gul;Kim Sang-Kyun;Park Chae-Woon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.479-482
    • /
    • 2001
  • This paper proposes a modified $\alpha$ conduction mode for controlling the output voltage magnitude of three-phase square-wave VSIs with an R-L load. From the viewpoint of both power capacity and switching losses, three-phase square-wave inverters are now used in most high power systems. When the square-wave VSI is driven with $\alpha$ conduction mode to control the magnitude of output voltages, interval over than half period is operated with $180^{\circ}$ conduction mode and the other interval with $120^{\circ}$ conduction mode. In $120^{\circ}$ conduction mode operation, two output terminals are connected to DC supply and the third one remains open. The potential of this open terminal will depend on the load characteristics and is unpredictable except the case of pure resistive loads. To cope this problem, we propose the modified α conduction mode.

  • PDF

BATHYMETRIC MODULATION ON WAVE SPECTRA

  • Liu, Cho-Teng;Doong, Dong-Jiing
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.344-347
    • /
    • 2008
  • Ocean surface waves may be modified by ocean current and their observation may be severely distorted if the observer is on a moving platform with changing speed. Tidal current near a sill varies inversely with the water depth, and results spatially inhomogeneous modulation on the surface waves near the sill. For waves propagating upstream, they will encounter stronger current before reaching the sill, and therefore, they will shorten their wavelength with frequency unchanged, increase its amplitude, and it may break if the wave height is larger than 1/7 of the wavelength. These small scale (${\sim}$ 1 km changes is not suitable for satellite radar observation. Spatial distribution of wave-height spectra S(x, y) can not be acquired from wave gauges that are designed for collecting 2-D wave spectra at fixed locations, nor from satellite radar image which is more suitable for observing long swells. Optical images collected from cameras on-board a ship, over high-ground, or onboard an unmanned auto-piloting vehicle (UAV) may have pixel size that is small enough to resolve decimeter-scale short gravity waves. If diffuse sky light is the only source of lighting and it is uniform in camera-viewing directions, then the image intensity is proportional to the surface reflectance R(x, y) of diffuse light, and R is directly related to the surface slope. The slope spectrum and wave-height spectra S(x, y) may then be derived from R(x, y). The results are compared with the in situ measurement of wave spectra over Keelung Sill from a research vessel. The application of this method is for analysis and interpretation of satellite images on studies of current and wave interaction that often require fine scale information of wave-height spectra S(x, y) that changes dynamically with time and space.

  • PDF

Rayleigh-wave Phase Velocities and Spectral Amplitudes Affected by Insertion of an Anomalous Velocity Layer in the Overburden (천부 속도이상층이 레일리파 위상속도 및 수직변위 스펙트럼 진폭에 미치는 영향)

  • Kim, Ki Young;Jung, Jinhoon
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.155-162
    • /
    • 2012
  • The Thomsen-Haskell method was used to determine sensitivities of the Rayleigh-wave phase velocities and spectral amplitude of vertical ground motion to insertion of a single velocity-anomaly layer into overburden underlain by a basement. The reference model comprised a 9-m thick overburden with shear-wave velocity (${\nu}_s$ of 300 m/s above a half-space with ${\nu}_s$ = 1000 m/s. The inserted layer, with a velocity of 150, 225, 375, or 450 m/s and a thickness of 1, 2, or 3 m, was placed at depths increasing from the surface in increments of 1 m. Phase velocities were computed for frequencies of 4 to 30 Hz. For inserted layer models, we placed an anomalous layer with thickness of 1 ~ 3 m, shear-wave velocity of 150 ~ 450 m/s, and at depths of 0 ~ 8 m in the overburden. The frequency range of 8 ~ 20 Hz were the most sensitive to the difference of $C_R$ between the inserted and reference models (${\Delta}C_R$) for h = 1 m and the frequency range got wide as h increased. For all of the models, the spectral amplitudes of the fundamental mode exceeded those of the $1^{st}$-higher mode except at frequencies just above the low-frequency cutoff of the $1^{st}$-higher mode.

Adaptive Detection of Unusual Heartbeat According to R-wave Distortion on ECG Signal (심전도 신호에서 R파 왜곡에 따른 적응적 특이심박 검출)

  • Lee, SeungMin;Ryu, ChunHa;Park, Kil-Houm
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.200-207
    • /
    • 2014
  • Arrhythmia electrocardiogram signal contains a specific unusual heartbeat with abnormal morphology. Because unusual heartbeat is useful for diagnosis and classification of various diseases, such as arrhythmia, detection of unusual heartbeat from the arrhythmic ECG signal is very important. Amplitude and kurtosis at R-peak point and RR interval are characteristics of ECG signal on R-wave. In this paper, we provide a method for detecting unusual heartbeat based on these. Through the value of the attribute deviates more from the average value if unusual heartbeat is more certainly, the proposed method detects unusual heartbeat in order using the mean and standard deviation. From 15 ECG signals of MIT-BIH arrhythmia database which has R-wave distortion, we compare the result of conventional method which uses the fixed threshold value and the result of proposed method. Throughout the experiment, the sensitivity is significantly increased to 97% from 50% using the proposed method.

An SPC-Based Forward-Backward Algorithm for Arrhythmic Beat Detection and Classification

  • Jiang, Bernard C.;Yang, Wen-Hung;Yang, Chi-Yu
    • Industrial Engineering and Management Systems
    • /
    • v.12 no.4
    • /
    • pp.380-388
    • /
    • 2013
  • Large variation in electrocardiogram (ECG) waveforms continues to present challenges in defining R-wave locations in ECG signals. This research presents a procedure to extract the R-wave locations by forward-backward (FB) algorithm and classify the arrhythmic beat conditions by using RR intervals. The FB algorithm shows forward and backward searching rules from QRS onset and eliminates lower-amplitude signals near the baseline using a statistical process control concept. The proposed algorithm was trained the optimal parameters by using MIT-BIH arrhythmia database (MITDB), and it was verified by actual Holter ECG signals from a local hospital. The signals are classified into normal (N) and three arrhythmia beat types including premature ventricular contraction (PVC), ventricular flutter/fibrillation (VF), and second-degree heart block (BII) beat. This work produces 98.54% accuracy in the detection of R-wave location; 98.68% for N beats; 91.17% for PVC beats; and 87.2% for VF beats in the collected Holter ECG signals, and the results are better than what are reported in literature.