• 제목/요약/키워드: R wave amplitude

검색결과 75건 처리시간 0.025초

관상동맥질환을 진단하기 위한 R파와 T파의 크기에 대한 연구 (R and T Wave Amplitude as a Parameter to Detect Coronary Artery Disease)

  • 임현균;유권규;김진목;김인선;강찬석;박용기
    • Progress in Superconductivity
    • /
    • 제10권1호
    • /
    • pp.6-11
    • /
    • 2008
  • Multi-channel magnetocardiography (MCG) has been proposed to detect ischemic heart disease because its sensitivity is quite high comparing with other conventional diagnostic tools. Especially, current map and magnetic field map of MCG provide crucial information on whether myocardiac muscles maintain the normal conduction pathway. In addition, MCG parameters derived from repolarization are useful to detect coronary artery disease. Recently, there was a study reporting that R- and T- wave amplitude are highly correlated with ischemic heart disease. In this study, we studied R- and T-wave amplitude and their ratio as well as MCG parameters. MCG data from 20 young, 20 age-matched controls, and 20 myocardial infarction (MI) patients were analyzed. As a result, MCG parameters showed significant change in MI patients comparing to those of controls. R- and T-wave amplitude of MI patients showed a feature of severe ischemic heart disease even though it was difficult to find consistent values. Further study is needed to reveal the relations between small T-wave amplitude and coronary artery disease.

  • PDF

QRS 패턴에 의한 QS 간격과 R파의 진폭을 이용한 조기심실수축 분류 (PVC Classification based on QRS Pattern using QS Interval and R Wave Amplitude)

  • 조익성;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.825-832
    • /
    • 2014
  • 조기심실수축 분류를 위한 기존 연구들은 분류의 정확성을 높이기 위해 신경망, 퍼지 이론, SVM 등과 같은 비선형 방법이 주로 사용되어 왔다. 이러한 대부분의 방법들은 P-QRS-T 지점의 정확한 측정을 필요로 하며, 데이터의 가공 및 연산이 복잡하다. 연산의 복잡도를 줄이기 위한 여러 가지 방법들이 제안되어 왔지만, 분류의 정확도가 떨어지는 문제점이 있었다. 또한 PVC는 개인의 특징에 따라 다양한 QRS 패턴이 존재하기 때문에 정확도에 한계가 있다. 따라서 이러한 문제점을 극복하기 위해서는 최소한의 특징점을 추출함으로써 연산의 복잡도를 줄이고, 개인마다 다른 QRS 패턴에 따라 PVC를 정확하게 분류할 수 있는 알고리즘이 필요하다. 따라서 본 연구에서는 QRS 패턴에 따른 QS 간격과 R파 진폭 변화율을 이용한 PVC 분류 방법을 제안한다. 이를 위해 전처리를 통해 잡음이 제거된 심전도 신호에서 R파, RR 간격, QRS 패턴을 추출한다. 이후 그 패턴에 따른 QS 간격과 R파의 진폭 변화율에 따라 PVC를 분류하였다. 제안한 방법의 우수성을 입증하기 위해 PVC가 30개 이상 포함된 MIT-BIH 9개의 레코드를 대상으로 한 R파의 평균 검출율은 99.02%의 성능을 나타내었으며, PVC 부정맥은 각각 93.72%의 평균 분류율을 나타내었다.

ECG 패턴 분석과 템플릿 문턱값을 통한 조기수축 부정맥분류 (Premature Contraction Arrhythmia Classification through ECG Pattern Analysis and Template Threshold)

  • 조익성;조영창;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.437-444
    • /
    • 2016
  • 일반적인 부정맥 분류 방법의 경우 심방 박동 수와 관련한 PP간격, P모양의 다양성과 같은 조건을 이용하는데, 잡음으로 인해 정확한 P파의 검출이 어렵기 때문에 잡음의 영향을 비교적 적게 받는 R파를 이용하는 것이 유리하다. 따라서 본 연구에서는 R파 중심의 ECG(electrocardiography) 패턴 분석과 템플릿 문턱치를 도입하여 조기수축 부정맥 분류 방법을 제안한다. 이를 위해 형태 연산을 통한 전 처리 과정과 차감 동작 기법을 통해 R파를 검출하였다. 이후 RR 간격의 평균 가중치와 변화율을 이용하여 먼저 조기수축 파형의 패턴을 분류하고, R파의 진폭에 대한 템플릿 문턱값을 통해 조기심실수축과 조기심방수축을 분류하는 알고리즘을 개발하였다. 제안한 방법의 우수성을 입증하기 위해 조기 심방과 심실수축이 30개 이상 포함된 MIT-BIH 6개의 레코드를 대상으로 한 R파의 평균 검출율은 99.77%의 성능을 나타내었고, 조기심실수축과 심방수축 부정맥은 각각 94.91%와 95.76%의 평균 분류율을 나타내었다.

Normal Mode Approach to the Stability Analysis of Rossby-Haurwitz Wave

  • Jeong, Hanbyeol;Cheong, Hyeong Bin
    • 한국지구과학회지
    • /
    • 제38권3호
    • /
    • pp.173-181
    • /
    • 2017
  • The stability of the steady Rossby-Haurwitz wave (R-H wave) in the nondivergent barotropic model (NBM) on the sphere was investigated with the normal mode method. The linearized NBM equation with respect to the R-H wave was formulated into the eigenvalue-eigenvector problem consisting of the huge sparse matrix by expanding the variables with the spherical harmonic functions. It was shown that the definite threshold R-H wave amplitude for instability could be obtained by the normal mode method. It was revealed that some unstable modes were stationary, which tend to amplify without the time change of the spatial structure. The maximum growth rate of the most unstable mode turned out to be in almost linear proportion to the R-H wave amplitude. As a whole, the growth rate of the unstable mode was found to increase with the zonal- and total-wavenumber. The most unstable mode turned out to consist of more-than-one zonal wavenumber, and in some cases, the mode exhibited a discontinuity over the local domain of weak or vanishing flow. The normal mode method developed here could be readily extended to the basic state comprised of multiple zonalwavenumber components as far as the same total wavenumber is given.

Influence of Tether Length in the Response Behavior of Square Tension Leg Platform in Regular Waves

  • El-gamal, Amr R.;Essa, Ashraf
    • International Journal of Ocean System Engineering
    • /
    • 제4권1호
    • /
    • pp.19-28
    • /
    • 2014
  • The tension leg platform (TLP) is a vertically moored structure with excess buoyancy. The TLP is regarded as moored structure in horizontal plan, while inherit stiffness of fixed platform in vertical plane. In this paper, a numerical study using modified Morison equation was carried out in the time domain to investigate the influence of nonlinearities due to hydrodynamic forces and the coupling effect between surge, sway, heave, roll, pitch and yaw degrees of freedom on the dynamic behavior of TLP's. The stiffness of the TLP was derived from a combination of hydrostatic restoring forces and restoring forces due to cables and the nonlinear equations of motion were solved utilizing Newmark's beta integration scheme. The effect of tethers length and wave characteristics such as wave period and wave height on the response of TLP's was evaluated. Only uni-directional waves in the surge direction was considered in the analysis. It was found that for short wave periods (i.e. 10 sec.), the surge response consisted of small amplitude oscillations about a displaced position that is significantly dependent on tether length, wave height; whereas for longer wave periods, the surge response showed high amplitude oscillations about that is significantly dependent on tether length.

한반도 동남부의 S파 감쇠 (Attenuation of S wave of the Southeastern Part of the Korean Peninsula)

  • 박동희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.51-57
    • /
    • 2001
  • In order to estimate attenuation characteristics, nonparametric model is used. Evaluation of this model requires suites of average spectral amplitude data as a function of distance without adopting any assumed parametric forms. Values of Quality factor, Q were estimated for individual frequencies by matrix inversion of S wave amplitude spectra for 21 records of 8 small and intermediate earthquakes (2.7$(1/r)^{1/2}$. The best models for 1/Q values were found to be 0.000453+0.001851/f and 0.000451+0.009261/f, respectively. This results can be compared to the conventional functional form of Q=$af^{b}$ and be used to estimate source spectra and site response.

  • PDF

삶은 계란을 섭취한 흰쥐의 심전도 (Electrocardiograms in the Rats Fed Diets with Boiled Eggs)

  • 박병성
    • 한국축산식품학회지
    • /
    • 제21권3호
    • /
    • pp.272-277
    • /
    • 2001
  • Electrocardiograms in rats fed diets with boiled eggs for 30 days was investigated. Amplitudes of P,Q and R waves were not significant differences among treatment groups. Amplitude of S wave in rats fed the diet with 95% boiled eggs was significantly tended to be increased compared with other groups(P<0.05). Amplitude of T wave in the rats fed the diet with 0% boiled eggs showed the highest values, and there were significant difference among treatment groups fed diets with 0% boiled eggs, 25% and 95% boiled eggs (P<0.05). Durations of P and PQ(PR) waves were high in the rats fed diets with 25% and 50% boiled eggs (P<0.05). Duration of QRS complex showed low in the rats fed diet 0% boiled eggs but not significant difference among treatment groups. Duration of QT was high in the rats fed diet with 0% boiled eggs(P<0.05). This result is assumed that electrocardiograms in the rats is not changed to intake the boiled eggs.

  • PDF

파력발전용 수조실의 수면 운동 변화에 대한 실험적 연구 (The Experimental Study about Kinetic Change of Water Surface in the Chambers for Wave Energy Converter)

  • ;문병영;이성범;김광중
    • 한국유체기계학회 논문집
    • /
    • 제17권2호
    • /
    • pp.41-47
    • /
    • 2014
  • Experimental results are given for the vertical motion of water in the water chambers for wave energy converter aligned along the wave propagation direction in order to avoid the impulsive wave forces. This paper mainly focuses on the property of the amplitude of the vertical motion of the water surface in the chambers. The amplification has been investigated by dimensionless parameters of wave period to resonance period ratio of the U-shaped oscillation, $T/T_r$, chamber size to wave length ratio, l/L, water depth to wave length ratio, h/L, amplitude of up-down motion of water particles to draft of the front wall ratio, ${\zeta}/D$. It has been shown that l/L should be less than 0.1 and as $T/T_r$ approaches unity the up-down of the water in the chambers is amplified. Also, the structure of the walls which form th water chambers has been examined roughly. It is deduced that the chambers set on both sides of the hull of a single-point moored floating vessel is preferable to those set along a fixed structure such as breakwaters.

혼합 작동 유체를 이용한 진동 세관형 히트 파이프의 압력 진동과 열전달 특성에 관한 연구 (The Study on Pressure Oscillation and Heat Transfer Characteristics of Oscillating Capillary Tube Heat Pipe Using Mixed Working Fluid)

  • 정현석;김정훈;김주원;김종수
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.318-327
    • /
    • 2002
  • In this paper, heat transfer and pressure oscillation characteristics on oscillating capillary tube heat pipe(OCHP) according to input heat flux, mixture ratio of working fluid and inclination angle were investigated and were compared single working fluid(R-142b) with binary mixture working fluid(R-142b-Ethano1). OCHP was made to serpentine structure of loop type with 10 turns by drilling the channels of length 220mm, width 1.5mm, and depth 1.5mm on the surface of brass plate. In this study, R-l42b and R-l42b-Ethanol were used as working fluids, the charging ratio of working fluids was 40(vol.%), the input heat flux to evaporating section was changed from 0.3W/㎠ to 1.8W/㎠, and mixture ratio of working fluid was R(100%), R(95%)-E(5%), R(90%)-E(10%), and R(85%)-E(15%). From the experimental results, it was found that the effective thermal conductivity of single working fluid was better than that of binary mixture working fluid. But, in case of binary mixture working fluid, critical heat flux was higher than that of single working fluid. And, the higher the mixture ratios of working fluid, the lower heat transfer performance. In case of pressure oscillation, as the inclination angle was lower, pressure wave was more irregular. These phenomena were more serious when the working fluid was binary mixture. Besides, when mixture ratio was higher, saturated pressure was increased, more irregular wave was observed and the mean amplitude was increased. For the same input heat flux, inclination angle and charging ratio, when pressure oscillation has sinusoidal wave, mean amplitude was small, and saturated pressure was low value, the heat transfer was excellent.

Personalized Specific Premature Contraction Arrhythmia Classification Method Based on QRS Features in Smart Healthcare Environments

  • Cho, Ik-Sung
    • 전기전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.212-217
    • /
    • 2021
  • Premature contraction arrhythmia is the most common disease among arrhythmia and it may cause serious situations such as ventricular fibrillation and ventricular tachycardia. Most of arrhythmia clasification methods have been developed with the primary objective of the high detection performance without taking into account the computational complexity. Also, personalized difference of ECG signal exist, performance degradation occurs because of carrying out diagnosis by general classification rule. Therefore it is necessary to design efficient method that classifies arrhythmia by analyzing the persons's physical condition and decreases computational cost by accurately detecting minimal feature point based on only QRS features. We propose method for personalized specific classification of premature contraction arrhythmia based on QRS features in smart healthcare environments. For this purpose, we detected R wave through the preprocessing method and SOM and selected abnormal signal sets.. Also, we developed algorithm to classify premature contraction arrhythmia using QRS pattern, RR interval, threshold for amplitude of R wave. The performance of R wave detection, Premature ventricular contraction classification is evaluated by using of MIT-BIH arrhythmia database that included over 30 PVC(Premature Ventricular Contraction) and PAC(Premature Atrial Contraction). The achieved scores indicate the average of 98.24% in R wave detection and the rate of 97.31% in Premature ventricular contraction classification.