• Title/Summary/Keyword: R곡선

Search Result 878, Processing Time 0.03 seconds

Study on Heterogeneous Structures and High-Frequency Magnetic Properties Amorphous CoZrNb Thin Films (비정질 CoZrNb 박막의 불균일 구조와 고주파 자기특성에 관한 연구)

  • 정인섭;허재헌
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.31-36
    • /
    • 1991
  • Structural and compositional heterogeneities of sputter deposited, amorphous $Co_{87}Zr_{4}NB_{9}$ thin films were investigated using TEM and EDS with windowless detector. The films deposited with substrate bias and annealed in rotating magnetc field showed two amorphous phases of Co-rich region and (ZrNb)oxide-rich region, and revealed 'ultra-soft' magnetic properties. Revesible bias-responses and overdamped frequency responses, along with small Hc, Hk and Mr/Ms ratio, give the possibility of ultra-soft magnetic behavior fo CoZrNb thin films. We proposed the vortex type magnetization distribution in remanent state which was correlated with the thin film heterogeneity. Then, the ultra-soft characteristics of the compositionally heterogeneous films were explained by the spin vortices that minimized the total magnetostatic and exchange coupling energies.

  • PDF

Calculation of Damping Ratio Using Non-Linear Soil Models and Comparison between Measured and Predicted Data (흙의 비선형 모델을 이용한 감쇠비 산정 및 비교)

  • Lee, Hyoung-Kyu;Bae, Yoon-Shin
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.21-28
    • /
    • 2011
  • Several theoretical soil nonlinear models to predict damping ratio, which is one of the typical dynamic properties of soils, it is impractical to predict damping ratio. The resonant column and torsional shear test(RC-TS) is used to represent the dynamic behavior of soils from intermediate to medium shear strains. A limitation of RC-TS is measure precise shear strain in large strains and the modified equivalent radius($R_{eq}$) was obtained using both modified hyperbolic model and Ramberg-Osgood model. Bonneville clays were tested using RC-TS test to obtain rotation and torque. The measured rotation and torque were then compared with calculated rotation and torque using curve-fitting method. Then, the nonlinear soil model parameters were obtained and the equivalent radius was calculated using the model parameters.

Characterization of A Catalystic Gas Sensor for Measuring Heat Content of Natural Gas (천연가스의 열용량을 측정하기 위한 촉매가스센서의 특징)

  • Lee K. Y.;Maclay G. J.;Stetter J. R.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 1998
  • A low power (below than 300 mW) catalytic bead combusible gas sensor is developed and utilized with a computer controlled sampling system for measuring heat content of natural gas. The heat content of gas is proportional to the change in the energy required to exposure to the sample of combustible gas. The heat content of natural gas samples ranging 36.30 - 39.88 $MJ/m^3$ is measured in the range of approximately $1\%$ error, which is comparable to its nominal heat content. Each gas represents a slightly different curve of sensitivity to sensor temperature. Thus all of the sensitivities are not equal to every temperature. In calibration process the choice of a optimum operating temperature is an important factor that influences the overall performance of the measurement system.

  • PDF

CFD Analysis of EFD-CFD Workshop Case 3 using Commercial and Open Source CFD codes (상용 및 오픈소스 CFD 코드를 이용한 EFD-CFD 워크샵 Case 3 해석)

  • Kim, Jong Rok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.3
    • /
    • pp.241-251
    • /
    • 2017
  • Computational fluid dynamics analysis was performed for the case 3 of the EFD-CFD workshop. Solvers were used for three commercial CFD codes(Star-CCM+, Fluent and CFX) and an open source CFD code(SU2). The grid were generated four types depending on the total cells using commercial grid generation code(Pointwise). Mach number of 0.4 and 0.8, 2 degree angle of attack and Mach number of 0.9, 1 degree angle of attack were calculated. Similar pressure coefficient curve and normal force coefficient were showed from the coarse grid to fine grid of four codes. But there is a difference in the drag coefficient. The position of the shock wave was predicted forward as the discretization order increased in calculations using Star-CCM+ and Fluent. The computation time to converge, Fluent, Star-CCM +, CFX are in order, and SU2 takes much time to converge.

Studies on the Rapid and Competitive Enzyme-linked Immunosorbent Assay for the Detection of Thyroxine (T$_4$) in Human Sera (경쟁적 효소면역측정법을 이용한 환자 혈청 내 Thyroxine (T$_4$)의 검출)

  • Sang-Wook Park;Jong-Bae Kim
    • Biomedical Science Letters
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 1999
  • Thyroxine (3,5,3',5'-L-tetraiodothyronine; T$_4$) is the most commonly measured thyroid hermono for the diagnosis of various thyroid disorders. Although radioimmunoassay (RIA) is still considered as the reference technique for the measurement of T$_4$, it is generally regarded that RIA has its primary disadventages in handling the wastes and controling the human and material resources. Therefore, establishment of enzyme-linked immunosorbent assay (ELISA) has of great significance. To verify the usefulness of our enzyme immunoassay, we have obtained the standard dose response curve of T$_4$ in patient's sera which is inversely proportional to the amount of herseradish peroxidase (HRP) conjugated monoclonal antibody of T$_4$ bound to the wells. The correlation coefficient (r) between the ELISA and chemiluminescent assay was 0.444 (n=38). Thus we have investigated the establishment of rapid and sensitive competitive ELISA assay method for detection of T$_4$ in patient's sera.

  • PDF

Determination of Riboflavin Content in Fishes (어육중의 riboflavin 함량의 측정)

  • SONG Yeong-OK;CHO Deuk-Moon;PYEUN Jae-Hyeung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.3
    • /
    • pp.219-223
    • /
    • 1987
  • A slightly modified method of Rashid and Potts(1980) to determine riboflavin in milk in which lead acetate was used as a precipitant was employed in tile present study to test applicability to determine that of fish as well. The lead acetate method was found to be sensitive, simple, inexpensive and rapid compared to the modified A.O.A.C. method by Cordon et al. (1979). But higher riboflavin values were obtained in this study than those reported so far. The riboflavin contents of 9 white fleshed fishes were in the range of $0.29\~0.48mg$ per 100g fresh sample. Linear regression equation Y=125.70X+0.71 (R=0.9993) was obtained for the calculation of riboflavin content in the white fleshed fish. Y is the concentration of riboflavin in the final solution to be chocked its OD at fluorometer and X is the dial reading of fluorometer. The stability of riboflavin as the freshness changes during icing storage$(at\;0^{\circ}C)$ was studied with file fish. During the initial stage of storage, the riboflavin content was found to by increased by $14\%$, but the difference was not statistically significant (p>0.05). K-value and VBN-value were increased along with storage time, but Proximate composition was not changed significantly during entire storage of 18 days.

  • PDF

Modeling of the driving pattern for energy saving of the railway vehicles (철도차량의 주행에너지 절약을 위한 열차 주행 패턴 모델링)

  • Kim, Jung-Hyun;Kim, Sang-Hoon;Shin, Han-Chul;Lee, Se-Hoon
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.01a
    • /
    • pp.107-108
    • /
    • 2011
  • Since the development of railway technology, the current urban Railway the first train line in the country for safe operation control automatic/unattended operation, automatic train operation equipment available (ATO) on time and reliable operation has introduced. ATO Automatic operation controlled by the value (Target velocity) and the feedback value (Actual velocity) by the error between the backing and braking of the train by repeated low energy efficiency. In this paper, given a fixed distance stations between time operation with minimal energy in the driving characteristics and driving trains are modeled. Therefore, in line 5 real route time sectional drive straight sections for experimental data analysis / draft Section / curved and section of the train on that line is selected according to the changing driving patterns to minimize the energy optimal driving patterns were presented.

  • PDF

Evaluation of the bioequivalence of Sumatriptan in healthy volunteers (이미그란 정 50 mg에 대한 수마트란 정의 생물학적 동등성 평가)

  • Yun, Hwi-Yeol;Baek, In-Hwan;Kwon, Kwang-Il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.15 no.2
    • /
    • pp.160-164
    • /
    • 2005
  • 수마트립탄은 뇌혈관에 분포되어 있는 5-HT1B/1D수용체에 특이적이고 선택적으로 작용하여 뇌혈관 수축 작용을 나타내어 편두통의 치료에 널리 쓰이는 약물이다. 본 연구는 수마트립탄 제제인 이미그란(50 mg tablet, GSK사)을 대조약으로 하여 시험약인 명인 제약의 수마트란 50mg정의 생물학적 동등성 평가를 하기 위해 22명의 건강한 지원자를 모집하였다. 지원자를 두 군으로 나누어 1정씩 투여하였고 $2{\times}2$ 교차시험을 실시하였다. 수마트립탄의 혈장 중의 농도를 정량하기 위하여 발리데이션된 HPLC/FD를 사용하였다. 채혈 시간은 투약 전 및 투약 후 0.5, 1, 1.5, 2, 2.5, 3,4, 5, 7, 9, 12시간에 걸쳐 총 12시점에 걸쳐 시행하였다. 생물학적 동등성을 판정하기 위한 파라미터로 12시간까지의 혈장 중 농도 곡선 하 면적$(AUC_{12hr})$ 최고 혈중 농도$(C_{max})$를 사용하였다. $AUC_{12hr}$의 평균은 $137.87ng{\cdot}ml/hr$(시험약)과 $130.12ng{\cdot}ml/hr$(대조약)으로 나타났다. $C_{max}$의 경우 각 각 29.30 ng/ml(시험약)과 29.25ng/m1(대조약)으로 관찰되었다. $AUC_{12hr}$의 경우 로그변환 한 평균치 차의 90% 신뢰구간이 log0.95-log1.24이었고, $C_{max}$의 경우 log0.90-log1.149로 계산되 어 두 항목 모두 log0.8-log1.25이어야 한다는 식품의 약품 안전청 과 FDA의 기준을 모두 만족시켰다. 이상의 결과를 종합하면 시험약 수마트란 정 50 mg은 대조약 이미그란 정 50 mg에 대하여 생물학적으로 동등한 것으로 판정되었다.

  • PDF

Structural Performance of Beam-Column Connections Using 51 mm Diameter with Different Anchorage Details (51 mm 대구경 철근을 사용한 외부 보-기둥 접합부의 정착상세별 구조성능 평가)

  • Kim, Jung-Yeob;Jung, Hyung-Suk;Chun, Sung-Chul;Kim, In-Ho;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.201-208
    • /
    • 2017
  • In exterior beam-column joints, hooked bars are used for anchorage, but usage of high-strength and large-diameter bars increases, headed bar is preferred for solving steel congestion and difficulty in construction. To investigate the structural performance of headed bars, Six exterior beam-column joints were tested under cyclic loading. Tests parameter were the anchorage methods and concrete strength. The test results indicate that behavior of headed bar specimens shows similar performance with hooked bar specimens. All specimens failed by flexural failure of the beam. Headed bar specimens shows better performance in anchorage and joint shear. All specimens were satisfied the criteria of ACI374.1-05. Test results indicate that use of headed bar in exterior beam column joint is available.

A Study on Physicochemical Characteristics of Hydrogen Gas Explosion (수소가스 폭발의 물리화학적 특성 연구)

  • Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • Hydrogen is considered to be the most important future energy carrier in many applications reducing significantly greenhouse gas emissions, but the explosion safety issues associated with hydrogen applications need to be investigated and fully understood to be applicable as the carrier. The risk associated with a explosion depends on an understanding of the impacts of the explosion, particularly the pressure-time history during the explosion. This work provides the effects of explosion parameters, such as specific heat ratio of burned and unburned gas, equilibrium maximum explosion pressure, and burning velocity, on the pressure-time history with flame growth model. The pressure-time history is dominantly depending on the burning velocity and equilibrium maximum explosion pressure of hydrogen-air mixture. The pressure rise rate increase with the burning velocity and equilibrium maximum explosion pressure. The specific heat ratio of unburned gas has more effect on the final explosion pressure increase rate than initial explosion pressure increase rate. However, the specific heat ratio of burned gas has more influence on initial explosion pressure increase rate. The flame speeds are obtained by fitting the experimental data sets. The flame speeds for hydrogen in air based on our experimental data is very low, making a transition from deflagration to detonation in a confined space unlikely under these conditions.