• Title/Summary/Keyword: R&D capacity

Search Result 885, Processing Time 0.031 seconds

Adsorption Characteristics of Toluene Vapor According to Pore Size Distribution of Activated Carbon (활성탄의 세공분포에 따른 Toluene Vapor의 흡착특성)

  • Lee Song-Woo;Kwon Jun-Ho;Kang Jeong-Hwa;Na Young-Soo;An Chang-Doeuk;Yoon Young-Sam;Song Seung-Koo
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.695-699
    • /
    • 2006
  • This study is to investigate the relationship between pore structures of activated carbons and adsorption characteristics of toluene vapor using dynamic adsorption method. The surface areas of below $10{\AA}$ in the pore diameter of activated carbons used in this experiment were in the range of 72 -93 % of total cumulative surface area and the toluene vapor equilibrium adsorption capacities were in the range of 350 - 390mg/g. Activated carbons having larger toluene adsorption capacity than the compared activated carbons had relatively pores in the pore diameter range of $7-10{\AA}$. Linear relationship between equilibrium adsorption capacity and cumulative sur- face area was in the diameter range of over $7{\AA}$. It was thought that toluene vapor was relatively well adsorbed on surfaces of pores of over $7{\AA}$.

Structural Analysis on A Steel Roof LNG Storage Tank (강재 지붕형 LNG 저장탱크 구조안전성평가)

  • Lee, Seung-Rim;Park, Jang-Sik;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.40-44
    • /
    • 2009
  • This is a comparative structural analysis for a steel roof LNG storage tank that has some advantages relatively in designing larger scale tanks and construction cost, etc. compared with a conventional concrete roof LNG storage tank as the capacity of LNG storage tanks is bigger. Structural analysis was performed on a 200,000$k{\ell}$ steel roof LNG storage tank and a concrete of the same capacity in condition of three critical load combination cases, a normal operation, a LNG spillage and seismic case by using finite element method. And comparative structural safety evaluation was carried out by using strength ratio in places of concrete wall, foundation and roof with a quantitative method.

  • PDF

A Study on Cooling Characteristics of Ground Source Heat Pump with Variation of Water Switching and Refrigerant Switching Methods (수절환 및 냉매절환방식에 따른 지열히트펌프의 냉방특성에 관한 연구)

  • Cha, Dong-An;Kwon, Oh-Kyung;Park, Cha-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.605-611
    • /
    • 2012
  • The objective of this study is to investigate the influence of the cooling performance for a water-to-water 10 RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The cooling capacity and refrigerant mass flow rate of the heat pump increased with increasing ground heat source temperature. But COP of the heat pump decreased with increasing ground heat source temperature. As a result, the water switching method with counter flow, compared to a refrigerant switching method, improves the cooling capacity and COP by approximately 6~9% in average, respectively.

The Surface Modification of Electrode with Solid Electrolyte Interphase for Hybrid Supercapacitor

  • Choi, Min-Geun;Kang, Soo-Bin;Yoon, Jung Rag;Lee, Byung Gwan;Jeong, Dae-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1102-1106
    • /
    • 2015
  • A hybrid supercapacitor (HS) is an energy storage device used to enhance the low weight energy density (Wh/kg) of a supercapacitor. On the other hand, a sudden decrease in capacity has been pointed out as a reliability problem after many charge/discharge cycles. The reliability problem of a HS affects the early aging process. In this study, the capacity performance of a HS was observed after charge/discharge. For detailed analysis of the initial charge/discharge cycles, the charge and discharge curve was measured at a low current density. In addition, a solid electrolyte interphase (SEI) layer was confirmed after the charge/discharge. A HC composed of a lithium titanate (LTO) anode and active carbon cathode was used. The charge/discharge efficiency of the first cycle was lower than the late cycles and the charge/discharge rate was also lower. This behavior was induced by SEI layer formation, which consumed Li ions in the LTO lattice. The formation of a SEI layer after the charge/discharge cycles was confirmed using a range of analysis techniques.

A Study on Developing Competency Model of Techno Leadership (기술리더십 역량모델 개발에 관한 연구 : IT기업 사례를 중심으로)

  • Park, Bum Joo;Lee, Hae Jun;Shin, Wan Seon
    • Korean Management Science Review
    • /
    • v.32 no.2
    • /
    • pp.1-14
    • /
    • 2015
  • The importance of technical innovation is increasing gradually in accordance with the life cycle of technology being shortened and the convergence being accelerate. This thesis aims to present the Framework of Competency Model of Techno Leadership capable of utilizing in promoting R&D (Research and Development) Leaders systematically by the technology based enterprise. The characteristic of core behavior necessary for Techno Leaders has been sorted out through the literature investigation and the analysis course of meaning, etc., the competency model of Techno Leadership has been deducted by analyzing the relation with MOT (Management of Technology) capacity being common skill of task necessary for Techno Leaders and the characteristic of behavior based on this through the questionnaire survey. The possibility of application in the field as well has been verified by applying the developed competency model in the actual field of enterprise. The competency model of techno Leadership developed in this research may be utilized in the direction establishment for the promotion of Techno Leadership in the enterprise or laboratory, especially, if would be effective to self-diagnose the core competency necessary for R&D manpower to be grown as the Techno leader in the IT oriented enterprise and to establish the improvement direction.

Comparison of Performance Characteristics in the Chevron Type Plate Heat Exchanger with Performance Correlation (성능 예측 상관식에 따른 쉐브론 형태 판형 열교환기 성능 특성 비교)

  • Bae, Kyung-Jin;An, Sung-Kuk;Cho, Hyun-Uk;Nam, Sang-Chul;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.535-542
    • /
    • 2011
  • The performance of a plate heat exchanger for using liquid solution in the absorption chiller-heater was analyzed. The model was developed by using the various performance prediction correlations. The performance characteristics of the plate heat exchanger with the mass flow rate ratio was verified by using experimental data. To investigate performance of plate heat exchanger with geometry variables, the chevron angle, corrugated wave length, and corrugation depth were changed. As a result, the capacity of Kim and Martin correlation models was similar with the experimental data, and the capacity difference was less than 2%. Besides, the pressure drop of Marin correlation model showed a similar variation with experimental data, and the difference of pressure drop was less than 1.5 kPa.

Design of High-Performance Lambda Network Based on DRS Model (DRS 모델에 기반한 고성능 람다 네트워크의 설계)

  • Noh, Min-Ki;Ahn, Sung-Jin
    • The Journal of Korean Association of Computer Education
    • /
    • v.12 no.2
    • /
    • pp.77-86
    • /
    • 2009
  • Large-scale applications, that needs large-capacity R&D resources and realtime data transmission, have demanded more stable and high-performance network environment than current Internet environments. Recently, global R&D networks have focuses on utilizing Lambda networking technologies and resource reservation systems to be satisfied with various applications' requirements. In this paper, we modify the existing DRS (Dynamic Right-Sizing) model to reflect various advantages in terms of the stability and high-capacity of Lambda network. In addition, we suggest the design methodology of high-performance Lambda network, which can integrate NRPS (Network Resource Provisioning System) into our modified DRS model.

  • PDF

Super Resolution Readout in Near Field Optical Data Storage System (근접장 광 기록 재생 시스템에서의 초해상 재생 현상 확인)

  • Lee, Jin-Kyung;Jeong, An-Sik;Shin, Jong-Hyun;Kim, Joo-Ho;Lee, Kyung-Geun;Kim, Joong-Gon;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Super-resolution near-field structure (super-RENS) technology and solid immersion lens (SIL) based near-field (NF) technology have been expected as promising approaches to increase data capacity or areal density of optical disc. Super-RENS technology has been studied until now using mainly numerical aperture (NA) of 0.85 far-field optical system and possibility of tangential data density increment have been presented. NF technology has been studied with NA over 1 and presented demonstration of removable performance. To achieve much higher density, approach to increase NA of super-RENS by NF technology (Near-Field Super-Resolution, NFSR) can be a candidate and we think this technology would be advantageous compared to wavelength reduction or much higher NA increment of NF technology or much smaller effective optical spot size reduction of far-field super-resolution technology. In this paper we present readout result of ROM media having monotone pits using NF optical system with wavelength of 405nm and NA of 1.84 surface type SIL. GeSbTe material was used for super resolution active layer and pit length is 37.5nm which is shorter than resolution limit 55nm. We present the feasibility of NFSR technology by confirming the CNR threshold according to readout power (Pr) and CNR 33dB over threshold Pr.

  • PDF

Elemental Mercury Adsorption Behaviors of Chemically Modified Activated Carbons

  • Kim, Byung-Joo;Bae, Kyong-Min;An, Kay-Hyeok;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1321-1326
    • /
    • 2011
  • In this work, the effects of different surface functional groups on the elemental mercury adsorption of porous carbons modified by chemical treatments were investigated. The surface properties of the treated carbons were observed by Boehm's titration and X-ray photoelectron spectroscopy (XPS). It was found that the textural properties, including specific surface area and pore structures, slightly decreased after the treatments, while the oxygen content of the ACs was predominantly enhanced. Elemental mercury adsorption behaviors of the acidtreated ACs were found to be four or three times better than those of non-treated ACs or base-treated ACs, respectively. This result indicates that the different compositions of surface functional groups can lead to the high elemental mercury adsorption capacity of the ACs. In case of the acid-treated ACs, the $R_{C=O}/R_{C-O}$ and $R_{COOH}/R_{C-O}$ showed higher values than those of other samples, indicating that there is a considerable relationship between mercury adsorption and surface functional groups on the ACs.

Performance Characteristics of a Vapor Injection Heat Pump System with Different Sub-cooler Capacity (과냉각 열교환기 용량 변화에 따른 인젝션 히트펌프의 성능 특성)

  • Choi, Jong Min;Park, Yong-Jung;Kang, Shin-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.3
    • /
    • pp.17-23
    • /
    • 2014
  • One major breakthrough in the field of heating, ventilation and air conditioning has been the development of heat pumps. Heat pump systems offer economic alternatives for recovering heat from different sources for use in various industrial, commercial and residential applications. In recent years, the heat pump has been tipped to have a very good potential for hot water production. This paper investigated the performance of a vapor injection heat pump with the variation of sub-cooler capacity at heating mode. The heating capacity of the vapor injection heat pump slightly increased with an increment of sub-cooler capacity, while COP didn't increase continuously. The 20% capacity of sub-cooler comparing with system capacity could be used as a standard to select sub-cooler capacity.