• Title/Summary/Keyword: Quick test

Search Result 365, Processing Time 0.102 seconds

KSR-III Helium Fill/prepressurization Umbilical Valve Development (KSR-III 헬륨 주입/선가압 엄비리칼 밸브 개발)

  • 정영석;조기주;조인현;오승협
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.164-167
    • /
    • 2003
  • In generally, Gas fill & drain valve is used in filling Gases to tank on high pressure in launcher The valve is quick coupling type and is separated by manual or remote control. In KSR-III, He gas fill & drain valve separated by remote control is used. In this paper, that are explained about the design specification, the test procedure, the autonomous test result and the flight test result.

  • PDF

A Study of the Developement of Washable Panties for Elderly Women of Incontinence Urine (노인여성을 위한 요실금 팬티 개발에 관한 연구)

  • 조진숙;최진희;허은영
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.5
    • /
    • pp.856-867
    • /
    • 2001
  • The purpose of this study was to develop washable panties for elderly women of incontinence urine. We carried out a questionnaire survey in order to find out what are the inconvenience of incontinence. Also we analyse the properties of incontinence panties available in silver market. Then we did wearing test of the existing continence panties to 40 subjects. Having done the wearing test, it was clear that the composit and the size of the absorbing layers must be crucial points of the development of the prototype panty. The prototype was designed to improve absorbing speed as well as capability without sacrificing of wearing comfort. The developed prototype panty went through wearing test and property tests to assure the design. The results are as follows:- 1. Absorbing capability as a whole, quick absorbance at the moment of passing of urine, the touch of the cover layer after quick absorbance and deodorant property were improved than existing incontinence panties. 2. The size and the dimensions of each part, specially absorbing layers at the crotch area, were remarkably improved.

  • PDF

Clinical Analysis of Influenza in Children and Rapid Antigen Detection Test on First Half of the Year 2004 in Busan (2004 상반기 부산 지역에서 유행한 인플루엔자의 임상 역학적 분석 및 인플루엔자 진단에 있어서의 신속 항원 검사법)

  • Choi, So Young;Lee, Na Young;Kim, Sung Mi;Kim, Gil Heun;Jung, Jin Hwa;Choi, Im Jung;Cho, Kyung Soon
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.2
    • /
    • pp.158-169
    • /
    • 2004
  • Purpose : Although influenza is one of the most important cause of acute respiratory tract infections in children, virus isolation is not popular and there are only a few clinical studies on influenza and diagnostic methods. We evaluated the epidemiological and clinical features of influenza in children and rapid antigen detection test(QuickVue influenza test) on fist half of the year 2004 in Busan. Methods : From January 2004 to June 2004, throat swab and nasal secretion were obtained and cultured for the isolation of influenza virus and tested by rapid antigen detection test(QuickVue influenza test) in children with suspected influenza infections. The medical records of patients with influenza virus infection were reviewed retrospectively. Results : Influenza viruses were isolated in 79(17.2%) out of 621 patients examined. Influenza virus was isolated mainly from March to April 2004. The ratio of male and female with influenza virus infection was 1.2 : 1 with median age of 4 years 6month. The most common clinical diagnosis of influenza virus infection was bronchitis. There was no difference between influenza A and B infection in clinical diagnosis and symptoms. All patients recovered without severe complication. The sensitivity obtained for rapid antigen detection test (QuickVue influenza test) was 93.6% and the specificity was 80.2%, the positive predictive value 40.8%, the negative predictive value 98.8%. Conclusion : With rapid antigen detection test, it is possible early detection of influenza in children. reduction in use of antimicrobial agent and early use of antiviral agent.

  • PDF

Development of the Quick Exhaust Valve to Blowing the Intake Filter for the Thermal Power Plant (화력발전소 흡입필터 세정용 급속 배기 밸브의 개발)

  • Jeong, C.S.;Lee, H.U.;Jeong, Y.M.;Lee, C.D.;Yang, S.Y.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.4
    • /
    • pp.548-552
    • /
    • 2010
  • The air suction filter of the power plant decrease the dust and impurities of suction air that reduce the life and efficiency of the boiler. The suction efficiency of the air filter falls with the dust and impurities when the time of use comes to be long. Therefore, the various contaminant of the filter must remove periodically. This paper presents a developed quick exhaust valve to use in the thermo-electric power plant. to removing contaminants on the filter, the blowing is done shortly by air pressure. The Air flowed out to the out side from the inside of the filter. The performance test of the developed valve is done by making a test-bench according to JIS and KS standards. The efficiency is found higher than the existing related valve.

The Performance Improvement of stopping for Induction Motor Using AC Drive (인버터를 이용한 유도전동기 감속 성능 개선)

  • Park, Kyeoung-Hun;Han, Kyung-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.296-297
    • /
    • 2011
  • Many applications involving induction motors that are controlled using variable frequency drives require the ability to stop quickly. These applications include emergency stops, quick stopping of fans, centrifuges, presses, etc. The technique that is widely accepted in the industry for achieving quick stopping makes use of brake resistors in series with a power semiconductor switch. The switch-resistor combination (brake-unit) is applied across the dc bus. The fastest decelerating time achievable depends on the size of the resistors and the switch employed. In this paper, the authors propose a novel method of achieving quick stopping times without the use of any brake-unit. Experimental test results with and without this method on a large inertia motor-load combination show that the proposed stopping method is able to reduce the stopping time significantly compared to normal decelerated stop without the need for a braking unit.

  • PDF

A Study on the Surface Activation and Quick-setting Characteristics of Blast Furnace Slag (Blast furnace slag의 표면 활성화 특성 및 quick-setting 특성에 관한 연구)

  • Lee, Woong-Geol;Song, Yung-Sin;Kang, Hyun-Ju;Choi, Hun;Song, Yong-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.273-274
    • /
    • 2010
  • This study investigated on the early hydration and physical characteristics of blast furnace slag through pH variation. The pH values applied to the experiments were, 12.0 and 13.0 which are the pH values of OPC, and type 3 of pH 14.0 which is a strong alkali condition. A paste and mortar method was used to test blast furnace slag and blast furnace slag containing 2wt% of gypsum. It was found that CAH and CSH phases were formed as key hydrates during the early hydration of blast furnace slag, and ettringites were produced extra during the early hydration of blast furnace slag containing 2wt% of gypsum.

  • PDF

ANALYSIS OF NON-POINT SOURCE POLLUTION LOADING IN A SMALL RURAL WATERSHED USING HIGH SPATIAL RESOLUTION IMAGE

  • Park, Jong-Yoon;Lee, Mi-Seon;Kim, Seong-Joon
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.229-233
    • /
    • 2007
  • This study is to test the applicability of QuickBird image for non-point source pollution assessment. SWAT (Soil and Water Assessment Tool) model was adopted and the model was calibrated for a stream watershed of 255.4 $km^2$ Landsat land use data. For model application with QuickBird image, a precise agricultural land use map of 1.16 $km^2$ area located in the upstream watershed was produced by field investigation. The model was run with the combination of land use and soil map scales (1:5,000, 1:25,000 and 1:50,000). The results were compared and analyzed for the contribution of non-point source pollution by the land use scale and contents.

  • PDF

Mechanical Properties of the Stabilized Sludge (안정화시킨 슬러지의 역학적 특성)

  • 송창섭;권현일
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.599-605
    • /
    • 1999
  • An experimental investigation was carried out to study the feasibility of using the stabilized sludge, as a backfill and cutoff-water materials for embanckment structures. for stabilizing of sludge, hydrated lime and quick lime was used as additive , and a series of tests was performed on the sludge and the stabilized sludge to examine their physical properties, compaction, compressive strength, hydraulic conducivity and consolication characteristics. From the test results, the physical and mechanical properteis of the stabilized sludge weremore improved as compared with the sludge. Especially from the viewpoint of physical porperty , consolidation or settlement and cutoff-water , quick lime is more effective than the hydraged lime as tabilizatio addtivie. But , viewpoint of compaction and shear strength, hydrated lime is more effective than the quick lime as stabilization additive. As a result of this study, it was founded that the stabilized sludge can be developed the backfill and cutoff-water materials , improved the stabilizing method of sludge.

  • PDF

Physical and Mechanical Properties of Waterwaste Sludge and Stabilized Sludge (슬러지 및 안정화시킨 하수 슬러지의 물리적.역학적 특성)

  • 송창섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.6
    • /
    • pp.97-104
    • /
    • 1999
  • An experimental investigation was carried out to study the feasibility of using the stabiliozed sludge, as a backfill and cutoff-water materials for embankment structures. For stabilizing of sludge, hydrated lime and quick lime were used as additive, and a series of tests were performed on the sludge and the stabilized sludge to examine their physical and mechanical properties , compaction, compressive strength, hydraulic conuctivity and consolidation characteristics. From the test results, physical and mechanical properties of the stabilized sludge were improved as compared with the sludge. Especially from the viewpoint of physcial property, consolidation or settlement and cutoff-water, quick lime is more effective than the hydrated lime as a stabilization addtive. But, viewpoint of compaction and shear strength, hydrated lime is more effective than the quick lime as a atabilization additive. As a result of this study, it was found that the stabilized sludge can be developed the backfill and cutoff-water materials, improved the stabilizing method of sludge.

  • PDF

Evaluation of Convection Schemes for Thermal Hydraulic Analysis in a Liquid Metal Reactor (액체금속로 내부 열유동해석을 위한 대류항처리법 평가)

  • Choi Seok-Ki;Kim Seong-O;Kim Eui-Kwang;Eoh Jae-Hyuk;Choi Hoon-Ki
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.64-69
    • /
    • 2002
  • A numerical study has been peformed for evaluation of convection schemes for thermal hydraulic analysis in a liquid metal reactor Four convection schemes, HYBRID, QUICK, SMART and HLPA included in the CFX-4 code are considered. The performances of convection schemes are evaluated by applying them to the five test problems. The accuracy, stability and convergence are tested. It is shown that the HYBRID scheme is too diffusive, and the QUICK scheme exhibits overshoots and undershoots, and the SMART scheme shows convergence oscillations, and the HLPA scheme preserves the boundedness without causing convergence oscillations. The accuracies of SMART, QUICK and HLPA schemes are comparable. Thus, the use of HLPA scheme is highly recommended for thermal hydraulic analysis in a liquid metal reactor.

  • PDF