• 제목/요약/키워드: Quench characteristics

검색결과 220건 처리시간 0.026초

2차 권선의 연결방법에 따른 변압기형 초전도 한류기의 특성 (Characteristics of Transformer-Type SFCL according to the Connecting Methods of Secondary Coils)

  • 조용선;박형민;정수복;최효상
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2078-2083
    • /
    • 2007
  • We have analyzed operating characteristics of transformer-type superconducting fault current limiter (SFCL) according to the serial or parallel connections of secondary coils with $YBa_2Cu_3O_7$ (YBCO) thin films. The turn ratio between the primary and secondary coils was 63:21. Transformer-type SFCL using a transformer with secondary winding of serial or parallel coils could reduce the unbalanced quench caused by differences of the critical current density between YBCO thin films. We found that transformer-type SFCL having serial or parallel connections induced simultaneous quench between the superconducting units. The limiting current in the transformer-type SFCL with a parallel connection was lowered to 30 % compared to the SFCL with a serial connection. In the meantime, when the currents generated in the superconducting units were similar, the voltage value in the parallel connection was 60 % as low as that in the serial connection. However, the voltage generated in the primary winding was some higher. In conclusion, we found that transformer-type SFCL with parallel connection of secondary coils was more effective in fault current limiting characteristics and in the reduction of the consumption power for superconducting units compared to those of the transformer-type SFCL with serial connection of secondary coils.

Current and voltage loading tests off resistive SFCL

  • 최효상;현옥배;김혜림;황시돌;박권배
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.241-246
    • /
    • 2002
  • We have performed the current and voltage loading tests of resistive superconducting fault current limiters (SFCLS) based on $YBa_2$$Cu_3$$O_{7}$(YBCO) films with the diameter of 2 inch. The SFCL consists of meander-type YBCO stripes covered with 200 nm Au layer grown in situ for current shunt and heat dispersion at hot spots. The minimum quench current of an SFCL unit was about 25 Apeak. Seven SFCL units were connected in parallel fur the current load ing tests at power source of 100 $V_{rms}$ $/2,000A_{rms}$. This SFCL units had maximum limiting current of 170 Apeak during the fault instant and then successfully controlled the fault current below 100 Apeak within 1~2 msec after short circuit. Increased short current also reduced the quench completion time with little change of current limiting characterization. We connected six SFCL units in series fur the voltage loading tests at power source of $1,200 V_{rms}$/170 $A_{rms}$ at this time. The shunt resistors were inserted into each SFCL unit to eliminate power imbalance originated from serial connection of SFCL units. Each SFCL unit was quenched simultaneously during the fault condition. The current increased up to 40 $A_{peak}$ and decreased to 14 $A_{peak}$ after 3 cycles. Quench was completed within 1 msec after the fault. We confirmed operating characteristics of 140 kVA($120 A_{rms}$ $\times$ 1,200 $V_{rms}$) SFCL and presented the manufacturing possibility of 3.3 kV SFCL using 4 inch YBCO films.BCO films.lms.

  • PDF

Transient Fault Current Limiting Characteristics of a Transformer Type SFCL Using an Additional Magnetically Coupled Circuit

  • Lim, Seung-Taek;Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권1호
    • /
    • pp.42-45
    • /
    • 2017
  • In this paper, a transformer type SFCL (superconducting fault current limiter) using an additional magnetically coupled circuit was suggested. Its transient fault current limiting characteristics, due to the winding direction of additional coupled circuit, were analyzed through fault current limiting tests. The suggested transformer type SFCL was composed of the primary winding, and one secondary winding wound on the same iron core together with an additional magnetically coupled circuit. That circuit consists of the other secondary winding together with the other SC (superconducting) element connected in parallel with its other secondary winding. As one of the effective design parameters to affect the transient fault current of the SFCL, the fault current limiting tests of the suggested SFCL were carried out considering the winding direction of its additional coupled circuit. It was confirmed that, through the analysis on the fault current tests of the SFCL, the quench sequence of two SC elements comprising the suggested SFCL could be adjusted by the winding direction of the additional coupled circuit.

$1{\times}3$ 행렬구조를 갖는 매트릭스형 초전도 한류기의 자장유무에 따른 퀜치특성 분석 (Analysis on the Quench Characteristics According to Magnetic Field of the Matrix-Type SFCL with $1{\times}3$ Matrix Structure)

  • 오금곤;조용선;최효상
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.343-348
    • /
    • 2008
  • We investigated the quench characteristics accordance with increase of turns and applied voltage of matrix-type superconducting fault current limiter (SFCL) with $1{\times}3$ matrixes. The matrix-type SFCL consists of the trigger part to apply magnetic field and the current-limiting part to limit fault current. The fault current limiting characteristics according to the increase of magnetic field and applied voltage were nearly same. This is because the application of magnetic field has not an affect on total impedance of SFCL. When number of turns of reactor increased, the voltage difference between two superconducting units in the current-limiting part according was decreased. The resistance difference generated in two superconducting units also was decreased. Therefore, we confirmed that the differences of critical behaviors between superconducting units by application of magnetic field were decreased. By this results, we could be decided the optimum number of turns of reactor to apply magnetic field.

2세대 초전도 선 안정화 층 구조변화가 비저항 특성에 미치는 영향 (Effect of Structure Change in Second-Generation Superconducting Wire Stabilization Layer on Resistivity Characteristics)

  • 반상재;두호익;정현기;두승규;양성채
    • 한국전기전자재료학회논문지
    • /
    • 제35권2호
    • /
    • pp.172-177
    • /
    • 2022
  • The quench voltage of the second-generation superconducting wire is affected by the resistivity characteristics of the stabilization layer. The specific resistance of the stabilization layer can be changed by the deposition process using RF magnetron sputtering. In this paper, a thin film made of a homogeneous material (Ag) and a dissimilar material (Cu) was deposited on the stabilization layer of the second-generation superconducting wire through RF magnetron sputtering. We found that the specific resistance was reduced by increasing the thickness of the stabilization layer. The reduction in the resistivity of the stabilization layer led to a decrease in the quench voltage of the second-generation superconducting wire. We suggest that various characteristic changes of the second-generation superconducting wire can be expected through the successful change in the resistivity of the stabilization layer of the proposed deposition process.

스테인레스 안정화 층을 갖는 YBCO Coated Conductor의 전류 제한 특성에 관한 연구 (Study on current limiting characteristics of YBCO coated conductor with stainless steel stabilizer layer)

  • 두호익;김민주;두승규;김용진;이동혁;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.365-366
    • /
    • 2009
  • This study researched into the manufacture of current-limit module of using YBCO coated conductor. Regarding over-current of exceeding the critical current, the quench characteristics were researched according to the stabilizing layer through tendency in resistance, which is generated in conductor, by applying over-current to YBCO coated conductors, which have stabilizing layer. YBCO coated conductors, which were used in experiment, include one kind such as the conductor, which used stainless as the stabilizing layer. The critical current is 70 A. And, the critical temperature is with 90 K. First of all, the quench generation was researched under over-current of exceeding the critical current by using this YBCO coated conductors. The tendency of a rise in the detected voltage according to the applied current was measured. And, the tendency of a rise in resistance through voltage-current curve was measured. As a result, the point of time in thermal quench of conductor, which has stainless as the stabilizing layer, could be confirmed to be fast.

  • PDF

YBCO 박막을 이용한 배전급 저항형 초전도 한류기 (Resistive Superconducting Fault Current Limiters for Distribution systems using YBCO thin films)

  • 이방욱;박권배;강종성;김호민;오일성;심정욱;현옥배
    • Progress in Superconductivity
    • /
    • 제7권2호
    • /
    • pp.114-119
    • /
    • 2006
  • High critical current density, high n value, multiple faults endurances, and fast recovery characteristics of YBCO thin films are very attractive characteristics for developing resistive type superconducting fault current limiters. But due to the limited current and voltage ratings of one YBCO module, it is needed to construct series and parallel module connections for high capacity electric networks. Especially for distribution network, more than 30 units should be connected in series to meet voltage level. So in order to construct distribution-level superconducting fault current limiter, simultaneous quench in one YBCO thin films should be realized, and furthermore, quench should be occurred in all fault current limiting units equally to avoid local heating and failures. In this paper, we proposed optimum design of YBCO thin films for fault current limiting module and technical method using shunt resistor to achieve simultaneous quench between multi current limiting units. From the analytical and the experimental results, optimal current path and thickness of shunt material was determined for YBCO thin films and shunt resistor between modules was developed. Finally, 14 kV one phase resistive fault current limiter using multi YBCO thin films was constructed and it was possible to get satisfactory test results.

  • PDF

IGCC 합성가스 급속 냉각시스템의 운전 압력에 따른 열유동 및 입자 거동 특성 연구 (Effect of Operating Pressure on the Heat Transfer and Particle Flow Characteristics in the Syngas Quench System of an IGCC Process)

  • 박상빈;양주향;오준호;예인수;류창국;박성구
    • 한국수소및신에너지학회논문집
    • /
    • 제25권1호
    • /
    • pp.97-104
    • /
    • 2014
  • In a coal gasifier for IGCC, hot syngas leaving the gasifier at about 1550oC is rapidly quenched by cold syngas recycled from the gas cleaning process. This study investigated the flow and heat transfer characteristics in the gas quench system of a commercial IGCC process plant under different operating pressures. As the operating pressure increased from 30 bar to 50 bar, the reduced gas velocity shortened the hot syngas core. The hot fly slag particles were retained within the core more effectively, and the heat transfer became more intensive around the hot gas core under higher pressures. Despite the high particle concentrations, the wall erosion by particle impaction was estimated not significant. However, large particles became more stagnant in the transfer duct due to the reduced gas velocity and drag force under higher pressures.

Au/YBCO 박막 meander line의 퀜치회복에 대한 분석 (Analysis on quench recovery of Au/YBCO thin film mender lines)

  • 김혜림;최효상;임해용;김인선;현옥배
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.92-94
    • /
    • 2001
  • We investigated quench recovery characteristics of Au/YBCO thin film meander lines. YB$a_{2}$$Cu_{3}$ $O_{7}$films were coated in-situ with a gold layer and patterned into 2 mm wide meander lines by photolithography. The limiters were tested with simulated fault currents at various source voltages. Resistance decreased first slowly and then rapidly to zero. Resistance vs. time curves for different source voltages fell on top of each other when translated horizontally. The slowly varying portion of data fell on straight lines of a slope on a semi-log scale at all source voltages. A heat balance equation reflecting heat loss from meander lines to surroundings explains these results quantitatively.

  • PDF

리액터의 권선수에 따른 매트릭스형 한류기 최적화 설계 (Optimal Design of Matrix-type SFCLs According to Turn Number of Reactors)

  • 정동철
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1944-1947
    • /
    • 2012
  • In this work, we investigated quench characteristics of matrix-type superconducting fault current limiters (MFCLs) according to the turn number of reactors. The reactors used in MFCLs apply magnetic field to superconducting elements within reactors when fault currents surge into MFCL systems. It makes the fast and simultaneous quenches between superconducting elements. Also reactors decrease the fault power burden of superconducting elements by bypassing the partial fault currents to itself, when quench occurs. These structure proposed in this work can be expected to achieve much more current limiting capacity even though it uses less superconductors compared with other type SFCLs. Three reactors were made by Bakelite. These reactors with the turn number of 190, 380 and 570, had the length of 270 mm and diameter of 80 mm. We reported experimental results, including fault currents, fault voltages and resistance in superconducting elements according to the turn number of reactors. We confirmed that experimental results will be useful in next future plan for the real power grid.