• 제목/요약/키워드: Quench Current

검색결과 311건 처리시간 0.022초

Increased impedance by quench at a shield layer of HTS power cable for fault current limiting function

  • Choi, Youngjun;Kim, Dongmin;Cho, Jeonwook;Sim, Kideok;Kim, Sungkyu;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권4호
    • /
    • pp.59-63
    • /
    • 2019
  • To reduce the fault current below the current capacity of a circuit breaker, researches on HTS (High Temperature Superconductor) power cables with fault current limiting (FCL) function are increasing. An FCL HTS power cable transports current with low a impedance during normal operation. Yet, it limits the fault current by an increased inductive or resistive impedance of conducting layer when quench occurs at the FCL HTS power cable by the large fault current. An inductive type FCL HTS power cable uses increased inductive impendence caused by leakage magnetic flux outside the cable core when the quench occurs at a shield layer losing the magnetic shielding effect. Therefore, it has an advantage of less resistive heating than resistive type FCL HTS power cable and temperature increase is suppressed. This paper describes an ideal circuit model for the FCL HTS power cable to investigate the effectiveness of increased inductive impedance when quench occurs at the shield layer. Then, FEM analysis is presented with a simplified model cable composed of various iron yokes to investigate the effect of the shape of yoke on the generation of the inductive impedance.

YBCO coated conductors(CCs)의 안정화재 두께 변화에 따른 quench/recovery 특성 분석에 관한 연구 (Quench/recovery test results of the YBCO coated conductors(CCs) having various stabilizer thicknesses)

  • 권나영;김현성;김광록;김경준;임성우;김혜림;현옥배;이해근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.10-14
    • /
    • 2009
  • Since a stabilizer of YBCO coated conductor (CC) plays a very important role of bypassing over-current and transferring heat generated in the moment of fault, it is one of big issues to determine the material of the stabilizer and its dimension for the high performance of the HTS power application system. Especially, in the case of a superconducting fault current limiter (SFCL), which requires it to react immediately to the occurrence of fault, characteristics of stabilizer are decisive in limiting fault current and recovering superconducting properties during and after quenching. In this paper, the quench / recovery characteristics of YBCO CCs with various thickness of stabilizer were analyzed. The quench/recovery test carried out at 20 $V_{rms}$, 5 cycles (60 Hz) and results showed that as the thickness of the stabilizer decreased, both the final approach temperature and the recovery time decreased.

Operating Properties of Resistive Superconducting fault Current Limiters with Various Pattern Shapes

  • Park, Hyo-Sang
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1286-1291
    • /
    • 2003
  • Quench behavior of resistive superconducting fault current limiters (SFCLS) with various pattern shapes was investigated. The pattern shapes employed were meander, bi-spiral, and spital shapes of identical line width, gap and margin. SFCLS were fabricated from YBCO thin films grown on two-inch diameter Al$_2$O$_3$ substrates under the same conditions. The total length of current limiting paths was the shortest at the spital shape due to its larger useless space. Inductance component of SFCLs with the spiral shape was around two times as high as those of other two shapes. This is not desirable since impedance characteristics of existing power systems can be changed. Resistance rise of current limiting elements was low at a spiral shape before the whole quench completion, which may act as a disadvantage for simultaneous quench in serial connection between current limiting elements, but the temperature tended to have similar values at higher voltages. On the other hand, hi-spital shape was severe at insulation level between current limiting lines. When these aspects were considered, we concluded that a meander shape was appropriate to design for a resistive SFCL based on thin films except the concentration of electric field at edge areas of strip lines.

YBCO film을 이용한 저항형 한류기의 안정적인 동작 조건 (Stabilized operating condition of resistive superconducting fault current limiter using YBCO film)

  • 최효상;현옥배;김혜림;황시돌;김상준
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.133-135
    • /
    • 2000
  • We fabricated resistive super- conducting fault current limiters (SFCL) based on YBCO thin films grown on a 2" diameter $Al_{2}$O_{3} substrate. The minimum quench current of the current minimum quench current of the current limiting element was about 8 $A_{peak}. This SFCL successfully controlled the fault current below 14.3 $A_{peak} at the voltage of 100$V_{rms}, which is otherwise to increase up to 141$A_{peak}. and the quench completion time is less than 3 msec. The temperature of the current limiting element rose to about 200K in 3 cycles after fault. The SFCL showed reproducible characteristics during hundreds times of repeated experiments.ents.

  • PDF

Stability characteristics of DyBCO coated conductor stabilized with stainless steel

  • Dixit, Manglesh;Kim, Tae-Hyung;Oh, Sang-Soo;Song, Kyu-Jeong;Kim, Ho-Min;Park, Kwon-Bae
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.288-289
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. We have experimentally studied the dependence of quench and recovery characteristics of coated conductors on the amplitude of current and duration time. The sample used in the present study is stabilized with stainless steel. Stability tests of 3 cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100 ms, with amplitude up to ~ 6 times of the critical current. The transport current that follows before and after the current pulse was fixed about ~85% the critical current. We analyzed the quench recovery using the current voltage characteristic.

  • PDF

0.7 MJ UPS용 초전도 케이블의 ?치 특성 (Quench Characteristics of the Superconduction Cable for a 0.7 MJ UPS)

  • 류경우;김해종
    • 한국전기전자재료학회논문지
    • /
    • 제11권7호
    • /
    • pp.565-570
    • /
    • 1998
  • Recently a few MJ superconducting magnetic energy storage ($\mu$ SMES) devices become commerci-ally available as one of the energy storage devices for uniterruptible power supply (UPS) systems. For such a ($\mu$ SMES) devics, a few kA class superconducting cables with high current density, high stability and excellent pulse characteristics are required. To acquire data for the superconduction cables related to design and fabrication of a 0.7 MJ $\mu$ SMES device, we tested critical currents and quench characteristics for several winding tensions and various remping rates especially. It is shown from the results that winding tensions have much influence on quench currents of the $\mu$ SMES devices.

  • PDF

초전도 케이블의 퀜치 특성에 대한 계통안전성 제어방식 (Power System Security Control Method for Quench Characteristic of High-Temperature Superconducting Cable)

  • 이근준;황시돌;이정필;김창현;박희철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.375-380
    • /
    • 2004
  • This paper presents the basic quench protection idea for the HTS(High-Temperature Superconducting) cable. In Korea power system, the transfer capability of transmission line is limited by the voltage stability, and HTS cable could be one of the countermeasure to solve the transfer limit as its higher current capacity and lower impedance[1]. However, the quench characteristic of HTS cable makes HTS cable to loss its superconductivity, and therefore change the impedance of the line and power system operating condition dramatically. This pheonominum threats not only HTS cable safety but also power system security, therefore a proper protection scheme and security control counterplan have to be established before HTS cable implementation. In this paper, the quench characteristics of HTS cable for the fault current based on heat balance equation was established and a proper protection method by FCL(Fault Current Limiter) was suggested.

  • PDF

SSC 쌍극자 마그네트의 퀜치 특성에 대한 연구 (Quench Characteristics of SSC Dipole Magnet Prototypes)

  • 나완수;류강식;권영길;조전욱;진홍범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1078-1080
    • /
    • 1993
  • The quench performance and ramp rate sensitivity of eighteen 5-cm-aperature, 15-m-long SSC dipole magnet prototypes are discussed. All the magnets appear to reach a quench plateau near their extrapolated short sample current limit and well in excess of the operating current with very little training. Most of the magnets, however, exibit a dramatic degradation of thier quench current as a function of ramp rate, which for the most part, can be attributed to large cable eddy currents.

  • PDF

스테인레스강 라미네이션된 DyBCO 초전도 선재의 퀜치 특성 (Quench characteristics of stainless steel laminated DyBCO coated conductor)

  • ;김태형;오상수;송규정;김호민;박권배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.1-4
    • /
    • 2005
  • As high temperature superconductor applications became a reality due to increase in coated conductor performance, it is important to understand their stability behavior to design safe electrical power systems. Coated conductors can be stabilized with different metals and alloys for different types of application, to yield excellent electrical, thermal and mechanical performance. We have experimentally studied the dependence of quench and recovery characteristics of stainless steel stabilized coated conductors on the amplitude of current and duration time. Stability test of 3cm long sample were performed in a liquid nitrogen bath cooling condition by applying a short period over current pulses for 50 and 100ms, with amplitude up to ~6 times the critical current. The transport current that flows before and after the current pulse was fixed at about ~80-85% critical current. We analyzed the quench and recovery phenomena of the test sample using the current voltage characteristic.

YBCO film을 이용한 저항형 초전도 한류기의 전류제한 특성 (Current limiting characteristics of the resistive SFCL using YBCO film)

  • 최효삼;김혜림;황시돌;현옥배;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.277-280
    • /
    • 1999
  • We fabricated a resistive superconducting fault current limiter of two stripe meander type based on a YBCO film, and performed current limitation experiments. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. At $0^{\circ}$ fault angle the minimum quench current was $9.6 A_{peak}$(meander line cross section: $5{\times}10^{-6}cm^2$) and the fast quench time was 0.63 msec. The resistance of the limiter continued to increase for three cycles due to heat generation in the gold layer and was stabilized afterwards. At $45^{\circ}$ and $90^{\circ}$ the fast quench time were 0.56 msec and 0.26 msec, respectively. The quench time is believed to be reduced because faults occurred when the current was increasing or was at the peak value. With the limiter we could effectively limit the fault current about 1/5 times right after the fault and about 1/8.5 times three cycles after.

  • PDF