• 제목/요약/키워드: Quasi-state

검색결과 502건 처리시간 0.03초

Subsidence estimation of breakwater built on loosely deposited sandy seabed foundation: Elastic model or elasto-plastic model

  • Shen, Jianhua;Wu, Huaicheng;Zhang, Yuting
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권4호
    • /
    • pp.418-428
    • /
    • 2017
  • In offshore area, newly deposited Quaternary loose seabed soils are widely distributed. There are a great number of offshore structures has been built on them in the past, or will be built on them in the future due to the fact that there would be no very dense seabed soil foundation could be chosen at planed sites sometimes. However, loosely deposited seabed foundation would bring great risk to the service ability of offshore structures after construction. Currently, the understanding on wave-induced liquefaction mechanism in loose seabed foundation has been greatly improved; however, the recognition on the consolidation characteristics and settlement estimation of loose seabed foundation under offshore structures is still limited. In this study, taking a semi-coupled numerical model FSSI-CAS 2D as the tool, the consolidation and settlement of loosely deposited sandy seabed foundation under an offshore breakwater is investigated. The advanced soil constitutive model Pastor-Zienkiewics Mark III (PZIII) is used to describe the quasi-static behavior of loose sandy seabed soil. The computational results show that PZIII model is capable of being used for settlement estimation problem of loosely deposited sandy seabed foundation. For loose sandy seabed foundation, elastic deformation is the dominant component in consolidation process. It is suggested that general elastic model is acceptable for subsidence estimation of offshore structures on loose seabed foundation; however, Young's modulus E must be dependent on the confining effective stress, rather than a constant in computation.

탠덤 배치된 FPSO와 셔틀탱커의 비선형 운동 해석 (Nonlinear Motion Analysis of FPSO and Shuttle Tanker in a Tandem Configuration)

  • 임춘규;이호영;신현경
    • 대한조선학회논문집
    • /
    • 제43권5호
    • /
    • pp.560-567
    • /
    • 2006
  • FPSO and shuttle tanker are connected to each other by a mooring hawser and a loading hose through which cargo oil is off-loaded. Even in mild sea-state. environmental loads can cause unstable large drift motions between two vessels in tandem off-loading operations, which may result in collision incidents. Accordingly. the analysis on the relative motion between two vessels due to the environmental loads should be investigated in initial design stage. In this study, the low speed maneuvering equation is employed to simulate nonlinear motions of FPSO and shuttle tanker. Low frequency wave drift forces including hydrodynamic interactions between two vessels are evaluated by near field approaches. Current loads are determined by mathematical model of MMG and wind loads are calculated by employing the wind spectrum according to the guidelines of API-RP2A. Mooring forces produced by turret mooring lines and a flexible hawser are modeled quasi-statically by catenary equations. The effect of environmental loads that affect nonlinear motion is investigated through variation in their magnitudes and the nonlinear motions between FPSO and shuttle tanker are simulated under wave, current and wind in time domain.

Methanol, Ethanol, 2-Propanol 그리고 1-Butanol 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정 및 예측 (The Measurement and Prediction of Flash Point for Binary Mixtures of Methanol, Ethanol, 2-Propanol and 1-Butanol at 101.3 kPa)

  • 오인석;인세진
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.1-6
    • /
    • 2015
  • 인화점은 화재 및 액체의 폭발 위험의 가능성을 결정하는 데 사용되는 가장 중요한 물리적 특성이고, 산업공정에서 안정성 평가시 중요한 연소특성 가운데 하나이다. 따라서 본 연구는 4류 위험물 중 알코올계 혼합물인 {methanol + 1-butanol}, {ethanol + 1-butanol} 그리고 {2-propanol + 1-butanol} 이성분계 101.3 kPa에서 최소인화점을 SETA closed cup flash point tester를 이용하여 측정하였다. 각 이성분계에 대하여 Wilson, NRTL 및 UNIQUAC 파라미터를 이용하여 혼합물에 대한 인화점 예측하고 실험 결과와 비교하였다. 비교결과 모든 예측값과 실험값은 유사한 값을 보였고 편차가 1.14 K 이내의 결과를 보였다.

반응성 이온 식각법에 의해 제작된 탄소나노튜브 전극의 전기화학적 특성 (Electrochemical Properties of Individual Carbon Nanotube Fabricated by Reactive Ion Etching)

  • 황숙현;최현광;김상효;한영문;전민현
    • 한국재료학회지
    • /
    • 제21권2호
    • /
    • pp.89-94
    • /
    • 2011
  • In this work, fabrication and electrochemical analysis of an individual multi-walled carbon nanotube (MWNT) electrode are carried out to confirm the applicability of electrochemical sensing. The reactive ion etching (RIE) process is performed to obtain sensitive MWNT electrodes. In order to characterize the electrochemical properties, an individual MWNT is cut by RIE under oxygen atmosphere into two segments with a small gap: one segment is applied to the working electrode and the other is used as a counter electrode. Electrical contacts are provided by nanolithography to the two MWNT electrodes. Dopamine is specially selected as an analytical molecule for electrochemical detection using the MWNT electrode. Using a quasi-Ag/AgCl reference electrode, which was fabricated by us, the nanoelectrodes are subjected to cyclic voltammetry inside a $2{\mu}L$ droplet of dopamine solution. In the experiment, RIE power is found to be a more effective parameter to cut an individual MWNT and to generate "broken" open state, which shows good electrochemical performance, at the end of the MWNT segments. It is found that the pico-molar level concentration of analytical molecules can be determined by an MWNT electrode. We believe that the MWNT electrode fabricated and treated by RIE has the potential for use in high-sensitivity electrochemical measurement and that the proposed scheme can contribute to device miniaturization.

사업장 근로자의 고혈압 관리를 위한 자가발반사요법의 효과 (Effects of Self-foot Reflexology Shown in Hypertension Workers)

  • 차남현
    • 지역사회간호학회지
    • /
    • 제13권1호
    • /
    • pp.17-29
    • /
    • 2002
  • This study was carried out to investigate the effect of Self-foot reflexology (SFR) on the hypertension of workers. The purpose of the research was to evaluate: levels of knowledge, physical and emotional condition, work stress and fatigue on the hypertension of employees in the workplace. Quasi-experimental study was designed in the setting of a nonequivalent control and experimental Group applied by the pre and post test. The total subjects undertaken in the study were total of 34 employees working in three companies in Seoul. The SFR program was consisted of 6 phases. There were 2 minutes for preparation, 4 minutes for slow down, 26 minutes for base reflex, symptoms of a disease reflex and excretion reflex stimulation. Finally, there was 20 minutes relaxation in a comfortable posture and drinking hot water after blood pressure was checked in the order. This program was running 55 minutes a day everyday three times a week during the entire 8 week course. The finding showed blood pressure was reduced significantly. Moreover, the level of total cholesterol. high and low density lipoprotein cholesterol, depression, work stress, and fatigue were decreased in the study. But, they were not statistically significant except as it related to Group comparisons in time. The level of state anxiety was statistically significant between 2 Groups, but not in the time comparison of both Groups. As a summary of the study results, the SFR program was regarded as contributing to the physical and emotional promotion of employees. It had partially increased body circulations of functional organ related to the SFR sites. And, it improved relaxation of physical and mental condition through energy movement 'Chi'. Therefore, the SFR technique should be considered as an effective skill of a nursing program. Furthermore, it can be newly adopted as a nursing curriculum as a part of alternative treatment. However, it still needed to testify its effects through the review study.

  • PDF

접촉하중을 받는 코팅층이 있는 부재의 응력해석을 위한 부분 모델 방법의 개발 (The Development of Partial Model for Thermo-Mechanical Stress Analyses of Part with Coated Layer under Contact Load)

  • 권영두;김석삼;구남서;박정규
    • Tribology and Lubricants
    • /
    • 제18권3호
    • /
    • pp.194-203
    • /
    • 2002
  • This paper is the first step fur thermo-mechanical stress analyses of part with coated layer under contact load. A lot of coated material is applied in many structures to endure severe situation, like thermal stresses, high temperature gradients, irradiation, impacts by microscopic meteorites, and so on. In this part we are going to apply the FEM to analyze space parts with a coated layer subjected to a contact load thermo-mechanically. Coating layer is very thin in comparision with the structure, therefore it should take more times and behaviors to analyze whole model. In these reason we develop the FEM method of analyzing part with coated layer under contact load using partial model. Steady state temperature distribution of the part is obtained first, and then we apply quasi-static external load on the part. To obtain the final stage of solution, we compute the total solution, and by subtracting the thermal strain from the total ones we get the mechanical strains to compute stresses of the parts. In using the FEM, one has to discretize the model into many sub-domain, finite elements. The method is consisited of two steps. First step is to analyze the whole model with rather coarse meshes. Second step we cut a small region near the loading point, and analyze with very fine meshes. This method is allowable by the Saint-Venant's principle. And then, we finally shall check the therma1 load on the stresses of the space part with coating layer with or without substrate cracks. Then, we predict the actual behaviors of the part used in space.

Identification of progressive collapse pushover based on a kinetic energy criterion

  • Menchel, K.;Massart, T.J.;Bouillard, Ph.
    • Structural Engineering and Mechanics
    • /
    • 제39권3호
    • /
    • pp.427-447
    • /
    • 2011
  • The progressive collapse phenomenon is generally regarded as dynamic. Due to the impracticality of nonlinear dynamic computations for practitioners, an interest arises for the development of equivalent static pushover procedures. The present paper proposes a methodology to identify such a procedure for sudden column removals, using energetic evaluations to determine the pushover loads to apply. In a dynamic context, equality between the cumulated external and internal works indicates a vanishing kinetic energy. If such a state is reached, the structure is sometimes assumed able to withstand the column removal. Approximations of these works can be estimated using a static computation, leading to an estimate of the displacements at the zero kinetic energy configuration. In comparison with other available procedures based on such criteria, the present contribution identifies loading patterns to associate with the zero-kinetic energy criterion to avoid a single-degree-of-freedom idealisation. A parametric study over a family of regular steel structures of varying sizes uses non-linear dynamic computations to assess the proposed pushover loading pattern for the cases of central and lateral ground floor column failure. The identified quasi-static loading schemes are shown to allow detecting nearly all dynamically detected plastic hinges, so that the various beams are provided with sufficient resistance during the design process. A proper accuracy is obtained for the plastic rotations of the most plastified hinges almost independently of the design parameters (loads, geometry, robustness), indicating that the methodology could be extended to provide estimates of the required ductility for the beams, columns, and beam-column connections.

Nd-YAG LASER MICRO WELDING OF STAINLESS WIRE

  • Takatugu, Masaya;Seki, Masanori;Kunimas, Takeshi;Uenishi, Keisuke;Kobayashi, Kojiro F.;Ikeda, Takeshi;Tuboi, Akihiko
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.187-192
    • /
    • 2002
  • Applicability of laser micro welding process to the fabrication of medical devices was investigated. Austenitic stainless steel wire (SUS304) was spot melted and crosswise welded, which is one of the most possible welding process for the fabrication of medical devices, by using a Nd-YAG laser. Effects of welding parameters on the microstructure, tensile strength and corrosion resistance were discussed. In the spot melting, melted metal width decreased with decreasing the input energy and pulse duration. Controlling the laser wave to reduce laser noise which occurred in the early stage of laser irradiation made reasonable welding condition wider in the welding condition of small pulse duration such as 2ms. The microstructure of the melted metal was a cellular dendrite structure and the cell size of the weld metal was about 0.5~3.5 ${\mu}{\textrm}{m}$. Tensile strength increased with the decrease of the melted metal width and reached to a maximum about 660MPa, which is comparable with that for the tempered base metal. Even by immersion test at 318K for 3600ks in quasi biological environment (0.9% NaCl), microstructure of the melted metal and tensile strength hardly changed from those for as melted material. In the crosswise welding, joints morphologies were classified into 3 types by the melting state of lower wire. Fracture load increased with input energy and melted area of lower wire, and reached to a maximum about 80N. However, when input energy was further increased and lower wire was fully melted, fracture load decreased due to the burn out of weld metal.

  • PDF

램 가속기 성능 향상을 위한 예 혼합기 조성비 최적화에 관한 연구 (Premixture Composition Optimization for the Ram Accelerator Performance Enhancement)

  • 전용희;이재우;변영환
    • 한국추진공학회지
    • /
    • 제4권2호
    • /
    • pp.21-30
    • /
    • 2000
  • 본 연구에서는 램 가속기의 성능 향상을 위한 수치최적화를 수행하였다. 일정한 형상과 질량을 가진 탄체를 최초의 속도 $V_o$로부터 목표 속도 $V_e$로 가속시킬 때까지의 최소의 램 가속관 길이를 탐색하는 것을 목표로 하였고 $H_2$, $O_2$, $N_2$로 구성된 예 혼합기의 각 화학종의 몰수를 설계변수로서 채택하였다. 목적함수와 구속조건은 설계 과정에서 선형화 하여 구배법과 SLP기법을 적용하였다. 내부유동은 이차원 비점성 유동을 가정하고 화학반응의 해석은 8단계 7화학종 모델을 적용하였다. 가속관 길이의 결정을 위하여 램 가속관 내부의 유동은 준 정상상태로 가정하고 몇 개의 동일 구간으로 분할하여 각 속도에서의 추력 계수와 가속도를 동시에 구하여 전 속도 영역에 대하여 수치 적분하였다. 본 연구를 통하여 7회의 설계 반복으로 가속관의 길이를 19% 감소시켰다. 본 연구의 결과로부터 다단계, 다 화학종의 램 가속기의 설계최적화 문제에 직접적으로 적용할 수 있음을 확인하였다.

  • PDF

Tuning Photophysical and Electrochemical Properties of Heteroleptic Cationic Iridium(III) Complexes Containing Substituted 2-Phenylquinoxaline and Biimidazole

  • Sengottuvelan, Nallathambi;Seo, Hoe-Joo;Kang, Sung-Kwon;Kim, Young-Inn
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권8호
    • /
    • pp.2309-2314
    • /
    • 2010
  • Design and syntheses of four red phosphorescent heteroleptic cationic iridium(III) complexes containing two substituted phenylquinoxaline (pqx) or benzo[b]thiophen-2-yl-pyridin (btp) main ligands and one 2,2'-biimidazole (H2biim) ancillary ligand are reported: [$(pqx)_2$Ir(biim)]Cl (1), [$(dmpqx)_2$Ir(biim)]Cl (2), [$(dfpqx)_2$Ir(biim)]Cl (3), [$(btp)_2$Ir(biim)]Cl (4). Complex 1 showed a distorted octahedral geometry around the iridium(III) metal ion with cis metallated carbons and trans nitrogen atoms. The absorption, emission and electrochemical properties were systematically evaluated. The complexes exhibited red phosphorescence in the spectral range of 580 to 620 nm with high quantum efficiencies of 0.58 - 0.78 in both solution and solid-state at room temperature depending on the cyclometalated main ligands. The cyclic voltammetry of the complexes (1-3) showed a metal-centered irreversible oxidation in the range of 1.40 to 1.90 V as well as two quasi reversible reduction waves from -1.15 to -1.45 V attributed to the sequential addition of two electrons to the more electron accepting heterocyclic portion of two distinctive cyclometalated main ligands, whereas complex 4 showed a reversible oxidation potential at 1.24 V and irreversible reduction waves at -1.80 V.