• Title/Summary/Keyword: Quantity-per-unit

Search Result 114, Processing Time 0.029 seconds

Analysis of a Double Pipe Heat Exchanger for Waste Solvent Recovery (폐용제 회수용 이중관형 열교환기 특성 해석)

  • 구재현;이재근
    • Resources Recycling
    • /
    • v.9 no.3
    • /
    • pp.13-21
    • /
    • 2000
  • This study describes to analyze the heat transfer characteristics of waste solvent recovery system using a double pipe heat exchanger heating solvent by the hot oil. The solvent recovery system consists of the feeding pump, the double pipe heat exchanger, the vacuum spray chamber, and the condenser. A double pipe heat exchanger consists of the first section to conduct the heating of solvent to the thermal saturated point and the second section to evaporate the saturated solvent. The heat transfer area for vaporization of water, benzene and alkylbenzene was predicted by the heat balance modelling and experimentally measured from the temperature distribution as a function of solvent flow rate and heating temperature. The required heat transfer area for vaporization was increased with increasing solvent flow rates and with decreasing heating temperatures due to decreased quantity of transferred heat per the unit area. Theoretical modelling of the heat transfer area for solvents vaporization in the pipe showed good agreement with experimental results. Results showed to be suitable for the waste solvent recovery using a double pipe heat exchanger.

  • PDF

A Maintenance Model Applying Loss Function Based on the Cpm+ in the Process Mean Shift Problem in Which the Production Volume Decreases (생산량이 감소하는 공정평균이동 문제에서 Cpm+ 기준의 손실함수를 적용한 보전모형)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.1
    • /
    • pp.45-50
    • /
    • 2021
  • Machines and facilities are physically or chemically degenerated by continuous usage. The representative type of the degeneration is the wearing of tools, which results in the process mean shift. According to the increasing wear level, non-conforming products cost and quality loss cost are increasing simultaneously. Therefore, a preventive maintenance is necessary at some point. The problem of determining the maintenance period (or wear limit) which minimizes the total cost is called the 'process mean shift problem'. The total cost includes three items: maintenance cost (or adjustment cost), non-conforming cost due to the non-conforming products, and quality loss cost due to the difference between the process target value and the product characteristic value among the conforming products. In this study, we set the production volume as a decreasing function rather than a constant. Also we treat the process variance as a function to the increasing wear rather than a constant. To the quality loss function, we adopted the Cpm+, which is the left and right asymmetric process capability index based on the process target value. These can more reflect the production site. In this study, we presented a more extensive maintenance model compared to previous studies, by integrating the items mentioned above. The objective equation of this model is the total cost per unit wear. The determining variables are the wear limit and the initial process setting position that minimize the objective equation.

Study on the Impulse Characteristics for applying to the Ultra-wideband Antennas (초광대역 안테나에 적용 가능한 임펄스 특성에 관한 연구)

  • Doojin Lee;Muhun Park
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.362-368
    • /
    • 2023
  • In this paper, we presented the characteristics of the impulse signal which is applicable to the ultra-wideband antennas. In general, the width of the impulse has around sub nano or pico seconds in the time domain, where it corresponds to the wideband in the frequency domain. We confirmed by experiment that the impulse has around 130ps of the pulse width and bandwidth of 4GHz when 10MHz of sine wave excited as an input pulse. The fidelity factor was calculated in the time domain and -10dB bandwidth in the frequency domain was investigated for resistively loaded dipole antennas with different resistance per unit length. The received impulse signal through the wideband antennas is confirmed in the time and frequency domains that received pulse is to be similar to the generated impulse. The fidelity and bandwidth of the quantity value are 0.98 and 3.4GHz, respectively.

Effect of JiaoTeng-Yuan(교등원) on Oxidation Stress Caused by D-galactose in Sprague-Dawley Rats (교등원이 백서의 산화유발을 방어하는 작용에 관한 연구)

  • 이송실;이상재;김광호
    • The Journal of Korean Medicine
    • /
    • v.25 no.2
    • /
    • pp.194-206
    • /
    • 2004
  • Objectives : JiaoTeng-Yuan(교등원) is said to be a prescription for preservation of health in $\ulcorner$HuaTuo.ZhongZangJing (화타.중장경)$\lrcorner$. It is known to have the effect of Bu-Shen (보신: strengthening kidney) and Yi-Shou (익수: prolonging the span of one's life). This study investigates whether JTY is effective on inhibition of oxidation stress. Methods : Sprague-Dawley rats (12-week-old, weight $300{\pm}20g$) were divided into 3 groups. The normal group (n=8) was injected with PBS (1ml/body, s.c) subcutaneously behind the neck. The control group (n=8) was injected with D-galactose (50mg/kg, 1ml PBS/body, s.c) to induce pathological animals. The JTY group was injected with the same treatment as the control group, and fed containing JTY (10%). All groups were treated 1 time per day for 6 weeks. After the rats were sacrificed anti-oxidant enzyme (SOD, CAT, G-px) activity, GSH quantity of RBC and tissue (heart, liver and kidney), and plasma Vit-C quantity were examined. Also, the MDA levels of liver and kidney, lipofuscin of heart and endurance of erythrocyte membrane were measured. Results : In the JTY group, RBC's SOD activity decline was halted by 21 % of the normal level, compared to the control group, G-px activity (unit/g of Hb) increased significantly, compared to the normal group, and the level of Vit-C in plasma increased by 16%. Heart's SOD activity was kept at the same level as that of the normal group; and CAT activity decline was halted by 26%. Kidney's CAT and G-px activities were kept at the same level as that shown in the normal group, implying the existence of a halting effect. Liver also showed a slight halting effect against the decline of anti-oxidant ability, but the effect was not significant (${\alpha}=0.05$). A comparison between the levels of peroxide in SD rats showed that the level of TBARS in plasma increased significantly in the control group and that it was normal in the JTY group. The livers in the JTY group, compared to those in the control group, showed 36% halting effect of the normal level while their kidney's indicated the level significantly lower than the normal level. Heart's lipofuscin increased significantly in the control group, but was alike in both the JTY and the normal groups. Endurance of erythrocyte membrane (%) decreased significantly in the control group while it was kept at the similar level in both the JTY and the normal groups, indicating the halting effect. Conclusions : This study suggests that JTY is effective to defend oxidation stress caused by D-galactose in the animals. It showed that the anti-oxidant ability was maintained and strengthened. On the other hand, it reduced the level of peroxide in animals. In sum, JTY appeared to have the equilibrium normal physiological function in SD rat.

  • PDF

Quantity-based Early Cost Estimation Model for Road Construction Projects (대표물량 기반의 도로공사 설계단계의 개략공사비 예측모델)

  • Kim, Du Yon;Kim, Byungil;Yeo, Donghoon;Han, Seung Heon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3D
    • /
    • pp.373-379
    • /
    • 2009
  • Cost estimation in the early phase enables government to plan public budgeting more efficiently by providing information about construction cost. However, cost estimation in the early phase is difficult to predict because only a little information can be utilized. The cost estimation method now being used by the government is calculated by length of the road multiplied by unit cost per length and shows high error rate because it cannot reflect the unique characteristics of each project. As the project is being proceeded, level of available information also changed. So, reflecting available information of a project is important. This paper divided early phase into two parts : planning phase and early design phase, and developed cost estimation model considering level of available information of each phase. Total 143 cases are utilized to find influencing variables and develop cost estimation model and model validation is done by adopting required accuracy level. This cost estimation model reflecting level of available information can be applied to public budgeting, feasibility test, and comparison between routes.

Calculation of Unit Hydrograph from Discharge Curve, Determination of Sluice Dimension and Tidal Computation for Determination of the Closure curve (단위유량도와 비수갑문 단면 및 방조제 축조곡선 결정을 위한 조속계산)

  • 최귀열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.7 no.1
    • /
    • pp.861-876
    • /
    • 1965
  • During my stay in the Netherlands, I have studied the following, primarily in relation to the Mokpo Yong-san project which had been studied by the NEDECO for a feasibility report. 1. Unit hydrograph at Naju There are many ways to make unit hydrograph, but I want explain here to make unit hydrograph from the- actual run of curve at Naju. A discharge curve made from one rain storm depends on rainfall intensity per houre After finriing hydrograph every two hours, we will get two-hour unit hydrograph to devide each ordinate of the two-hour hydrograph by the rainfall intensity. I have used one storm from June 24 to June 26, 1963, recording a rainfall intensity of average 9. 4 mm per hour for 12 hours. If several rain gage stations had already been established in the catchment area. above Naju prior to this storm, I could have gathered accurate data on rainfall intensity throughout the catchment area. As it was, I used I the automatic rain gage record of the Mokpo I moteorological station to determine the rainfall lntensity. In order. to develop the unit ~Ydrograph at Naju, I subtracted the basic flow from the total runoff flow. I also tried to keed the difference between the calculated discharge amount and the measured discharge less than 1O~ The discharge period. of an unit graph depends on the length of the catchment area. 2. Determination of sluice dimension Acoording to principles of design presently used in our country, a one-day storm with a frequency of 20 years must be discharged in 8 hours. These design criteria are not adequate, and several dams have washed out in the past years. The design of the spillway and sluice dimensions must be based on the maximun peak discharge flowing into the reservoir to avoid crop and structure damages. The total flow into the reservoir is the summation of flow described by the Mokpo hydrograph, the basic flow from all the catchment areas and the rainfall on the reservoir area. To calculate the amount of water discharged through the sluiceCper half hour), the average head during that interval must be known. This can be calculated from the known water level outside the sluiceCdetermined by the tide) and from an estimated water level inside the reservoir at the end of each time interval. The total amount of water discharged through the sluice can be calculated from this average head, the time interval and the cross-sectional area of' the sluice. From the inflow into the .reservoir and the outflow through the sluice gates I calculated the change in the volume of water stored in the reservoir at half-hour intervals. From the stored volume of water and the known storage capacity of the reservoir, I was able to calculate the water level in the reservoir. The Calculated water level in the reservoir must be the same as the estimated water level. Mean stand tide will be adequate to use for determining the sluice dimension because spring tide is worse case and neap tide is best condition for the I result of the calculatio 3. Tidal computation for determination of the closure curve. During the construction of a dam, whether by building up of a succession of horizontael layers or by building in from both sides, the velocity of the water flowinii through the closing gapwill increase, because of the gradual decrease in the cross sectional area of the gap. 1 calculated the . velocities in the closing gap during flood and ebb for the first mentioned method of construction until the cross-sectional area has been reduced to about 25% of the original area, the change in tidal movement within the reservoir being negligible. Up to that point, the increase of the velocity is more or less hyperbolic. During the closing of the last 25 % of the gap, less water can flow out of the reservoir. This causes a rise of the mean water level of the reservoir. The difference in hydraulic head is then no longer negligible and must be taken into account. When, during the course of construction. the submerged weir become a free weir the critical flow occurs. The critical flow is that point, during either ebb or flood, at which the velocity reaches a maximum. When the dam is raised further. the velocity decreases because of the decrease\ulcorner in the height of the water above the weir. The calculation of the currents and velocities for a stage in the closure of the final gap is done in the following manner; Using an average tide with a neglible daily quantity, I estimated the water level on the pustream side of. the dam (inner water level). I determined the current through the gap for each hour by multiplying the storage area by the increment of the rise in water level. The velocity at a given moment can be determined from the calcalated current in m3/sec, and the cross-sectional area at that moment. At the same time from the difference between inner water level and tidal level (outer water level) the velocity can be calculated with the formula $h= \frac{V^2}{2g}$ and must be equal to the velocity detertnined from the current. If there is a difference in velocity, a new estimate of the inner water level must be made and entire procedure should be repeated. When the higher water level is equal to or more than 2/3 times the difference between the lower water level and the crest of the dam, we speak of a "free weir." The flow over the weir is then dependent upon the higher water level and not on the difference between high and low water levels. When the weir is "submerged", that is, the higher water level is less than 2/3 times the difference between the lower water and the crest of the dam, the difference between the high and low levels being decisive. The free weir normally occurs first during ebb, and is due to. the fact that mean level in the estuary is higher than the mean level of . the tide in building dams with barges the maximum velocity in the closing gap may not be more than 3m/sec. As the maximum velocities are higher than this limit we must use other construction methods in closing the gap. This can be done by dump-cars from each side or by using a cable way.e or by using a cable way.

  • PDF

Comparison of Analytical Methods for DEHP Migration from PVC Bags for Blood Storage and Infusion; By Gas Chromatography and UV-vis Spectrophotometry (혈액·수액용 PVC 백에서 용출된 DEHP의 검출 분석 방법 비교; 기체 크로마토그래프와 분광 광도계)

  • Kim, Jung Hwan;Kim, Seong Hun;Choi, Hyeong Ki;Lee, Chang Hyung
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.72-79
    • /
    • 2002
  • Di-(2-ethylhexyl)phthalate (DEHP) may be released from plasticized poly(vinyl chloride) (PVC) articles. In the cases of various methods for the quantitative analysis of migrating DEHP, there are much differences in migrating quantity according to the experimental methods. It is therefore important to make the comparison and analysis between these two results. A study of DEHP migration from blood and infusion bags has been carried out in different methods to evaluate the amount of DEHP migration using gas chromatograph and UV-vis spectrophotometry. Five PVC bags were cut into plane sheets in size of $40{\times}10{\times}0.4mm$, then were immersed in extraction solvent for an hour to release DEHP. It was determined by a gas chromatograph that $23.2{\sim}70.9{\mu}g/mL$ of DEHP was extracted. While extraction solvent was injected into PVC bags which were then placed for an hour to leach DEHP out. It was checked by a UV-vis spectrophotometer that the concentration of DEHP in extraction solvent was $24.8{\sim}41.3{\mu}g/mL$. Two results show different values according to the extraction conditions and experimental methods and the gas chromatographic results were converted into UV-vis spectroscopic results on condition that DEHP would be extracted equally per unit time and unit contact area. It was concluded that DEHP migrating amounts are approximately equal in two analytical methods.

An Analysis of Local Quantity of Carbon Absorption, Fixation and Emission by Using GIS

  • Kim, Hyeon-Tae;Moon, Byeong-Eun;Choi, Eun-Gyu;Kim, Chi-Ho;Ryou, Young-Sun;Kim, Jong-Goo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.1
    • /
    • pp.40-48
    • /
    • 2014
  • Due to increasing greenhouse gas emissions, global warming and abnormal weather phenomena it has become important on a national level to keep a count of greenhouse gases being emitted. We want to take advantage of any selected area, as the basic data for the calculation of greenhouse gas emissions, Forest and Grassland, Paddy fields, and Fields(crops), Greenhouse(crops), Pig farm, Cattle farm, Farm household(populations, agricultural machinery) and Vehicle, the basic building blocks shots with a small amount of per-unit basis, the statistics calculated based on regional carbon emissions through the literature and experimental. Carbon absorption 772,960 ton C/year, amount of fixation 487,477 ton C/year, amount of emission 1,112,607 ton C/year were noted in Gimje-si, and amount of carbon absorption 55,559 ton C/year, amount of fixation 25,864 ton C/year, amount of emissions 58,355 ton C/year in Gongdeok-myeon, respectively. The carbon absorption at Hwangsan-ri is 25,107 ton C/year, fixation 4,301 ton C/year, and emission 20,330 ton C/year respectively. We were able to estimate the amount of carbon according to the specific characteristics of each unit village, then expanding it to a large-scale and comparative analysis, therefore we were able to obtain basic data on the national levels of carbon absorption.

An analysis on the characteristics of regasification system for LNG-FSRU depending on the changes in performance with vaporization and temperature of the heat source (LNG-FSRU용 재기화 시스템의 열원 온도 및 기화성능의 변동에 따른 시스템 특성분석)

  • Lee, Yoon-Ho;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.625-631
    • /
    • 2014
  • In this study, according to increase of thermoelectric power plants that use LNG, LNG-FSRU(Floating-Storage and Regasification Unit) appeared and it is installed on the Topside in order to deliver in a gaseous state to consumers who are in the shore. This study about the study on the characteristics analysis of the system depending on changes in performance with the vaporization and temperature of the heat source. For the characteristics analysis of the system, we devided vaporization method into Ethylene glycol water vaporization method and sea water as a heat source. Then the system that can vaporize 200ton per hour of LNG of $-157.9^{\circ}C$ and 10,400kPa was configured, and according to the temperature of supplied sea water, required minimum flow rate value was calculated. Also in case of using Ethylene glycol Water as a vaporization method, providing for regional and seasonal factors such as decrease of temperature of water. The system is configured by adding a steam boiler of $174.5^{\circ}C$, 775kPa as heat source. The generation amount of the steam required according to the performance of the vaporizer compared to the water temperature changes in the steam boiler and the amount of required evaporative performance due to changes in the quantity of steam and Ethylene glycol Water was confirmed.

A New Locomotor Evaluation System for Mouses Based on Continuous Shooting Images (연속 촬영 이미지를 이용한 Mouse의 운동 능력 평가 시스템)

  • Kwak, Ho-Young;Huh, Jisoon;Lee, Won Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.1
    • /
    • pp.153-161
    • /
    • 2015
  • In this paper, we propose a locomotor evaluation System for mouse based on continuous shooting images. In the field of veterinary medicine and animal studies are subjected to using the mouse for the quality of human life. In particular, during the experiments using the artificially created mice injury, through a variety of scoring and a lot of experiments to measure the extent of recovery from the injury. The traditional method of measuring the quantity of exercise while in this experiment was made of a method for directly observing person. The proposed system performs the continuous shooting per unit of time specified by the movement of the mouse is extracted from a continuous image shooting with the outline of a mouse point cloud. And using the extracted point cloud to extract again the inner contour of the body of the mouse. So using the new point cloud obtained its center, Then, using the center point calculated by accumulating the distance between two points on locomotor evaluation system design and implement to obtain the total distance the mouse moves over a unit of time.