• 제목/요약/키워드: Quantity Measurement

검색결과 448건 처리시간 0.026초

전달 시간차 방식 초음파 가스 유량계 (Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference)

  • 박상국;황원호
    • 제어로봇시스템학회논문지
    • /
    • 제9권9호
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

수화모델을 이용한 콘크리트의 초기온도 예측에 관한 연구 (The Evaluation of Temperature History in Concrete by Using Cement Hydration Model)

  • 왕소용;조형규;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.253-254
    • /
    • 2012
  • In this study, it carried out measurement experiment Ca(OH)2 and chemically bound water to verify Ca(OH)2 and chemically bound water prediction model out of hydration model of cement incorporating blast furnace slag. It compared and analyzed prediction results using prediction model with measurement results of Ca(OH)2 quantity using thermogravimetric differential temperature analysis and chemically bound water quantity using electronic furnace. It agrees well experiments results with prediction results.

  • PDF

적응 필터를 이용한 관내의 공동진동주파수 추정 (Estimation of Cavity Vibration Frequency in Air Tubes Using Adaptive Filter)

  • 양동성;서성대;남현도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2508-2510
    • /
    • 2001
  • Frequency of cavity vibration in air flowing tube is closely related to a velocity of air. In this research, an instrumentation system to estimate frequency of cavity vibration for measurement of the velocity and quantity of a moving fluid is implemented by using DSP TMS320C32. Measurement of the generated sound wave frequency in cavity is difficult because of environmental noise. Adaptive filters are used to eliminate this noise effectively. The estimated velocity and quantity of a moving fluid by proposed system is compared with the results measured by a standard flow meter.

  • PDF

오염입자의 부착상태가 시각적인 세정효과에 미치는 영향 (State of Stain Particle's ADhesion and Its Influence on Visual Consequence of Soil-Removal)

  • 신영선
    • 대한가정학회지
    • /
    • 제20권2호
    • /
    • pp.45-51
    • /
    • 1982
  • Degree of separation and adhesion of dye and stain particles has been measured usually by the rate of reflection of light. However, it could be proved that the relation between the quantity of stain and the rate of reflection greatly varied with kinds of stain and states of adhesion. For this study, several pieces of cotton and polyester having different states of stain adhesion were prepared by staining them with two kinds of artificial stain different in color: Ferric Oxide and Ferric Oxynate. Every piece went through soilremoval test which employed two surfactants: Anionic LAS and Cationic M2-100. After the operation, relations between quantity of pre-soilremoval stain and rate of reflection were measured, as well as those between quantity of post-soilremoval stain and rate of reflection. Rate of reflection and quantity of stain were not proportional in measurement to the pieces stained with Ferric Oxide and Ferric Oxynate. The consequence was also the same with cotton and polyester. That held true of the fat-stained textile. With the same quantity of stain, rate of reflection varied according to the magnitude of stain particles, and the state of adhesion influenced the magnitude of stain particles a great deal.

  • PDF

신재생에너지 지열을 이용한 열펌프유닛의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Unit Using Geothermal Heat for New Renewable Energy)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.630-636
    • /
    • 2020
  • This paper presents a experimental study on the performance of the heat pump. Uncertainty of measurement means the degree of uncertainty in the measurement. Therefore, it estimates a section where expected value of the measurement might be within a certain confidence level and suggests a range where measured representative value might be incorrect. Uncertainty of measurement is a parameter that shows characteristics of dispersion of measured value that was reasonably estimated from measured quantity. Measurement result of performance experiment is not a true value but estimated value that was estimated reasonably. Therefore, uncertainty of measurement needs to be calculated and presented with the result of measurement.

발사체 추진제 탱크 수위 측정 및 제어 시스템 기초연구 (Fundamental Research on the Measurement and Control System of Level Sensor for Launch Vehicle Propellant Tanks)

  • 신동순;한상엽;조인현;이응신
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.393-396
    • /
    • 2008
  • Propellant consumption control for space launch vehicle can be achieved by propellant utilization system (PUS) and tank depletion system (TDS). In the course of developing new space launch vehicles, the main target of design is on reducing of space launch vehicle weight, which results in increasing both specific impulse and payload weight. The weights of space launch vehicles are generally allocated to structure, propulsion system, and propellants loaded. The quantity of propellants filled in propellant tanks may be estimated with the propellants actually consumed by propulsion system to complete its mission and the propellants left on-board at the time of engine shut-off. To minimize the remaining quantity of propellants on-board the supplying propellants' O/F ratio should be controlled from the certain time before engine shutdown. To control an O/F ratio, a control system, which accurately measures and compares the remainder of propellants in tanks and pipes, should be needed. This paper solely dedicates its contents to explore the merits and demerits of various level sensor, which is one of the important elements for PUS and TDS, and the transmission and control of signals within space launch vehicle.

  • PDF

C-FVM을 이용한 토공장비의 CO2 배출계수에 관한 연구 (A Study on CO2 Emission Factor for Earth-Work Equipment Using C-FVM)

  • 김병수
    • 대한토목학회논문집
    • /
    • 제34권3호
    • /
    • pp.999-1006
    • /
    • 2014
  • 국토해양부에서 2011년 시설물별 탄소배출량 산정가이드라인을 통해 제시한 토공장비의 $CO_2$ 배출계수는 IPCC 탄소배출계수를 활용하여 연료사용량을 기반으로 만들어졌다. 하지만 이 방식은 현장의 다양한 조건을 반영하지 못한다는 단점이 있다. 따라서 이러한 단점을 보완한 새로운 배출계수가 필요하다. 본 연구에서는 토공장비를 대상으로 농도-유속측정(C-FVM)을 이용한 직접측정방식으로 $CO_2$ 배출량을 산정하고, 국토해양부에서 제시한 배출계수와 비교분석 후 토공장비의 새로운 $CO_2$ 배출계수를 제시하고자 한다.

가스온수가열기의 용량에 따른 에너지효율성 비교 연구 (A Comparative Study on the Energy Efficiency due to the Capacity of Gas Boiler)

  • 김성중;우인성
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.229-234
    • /
    • 2015
  • Depending on the living styles, the types of energy consumed by households have changed, and the consumption has increased rapidly. Consequently, those have led to environmental issues, such as exhaustion of energy and the climate changes. As one of solutions to such issues, energy efficiency can be approached. Therefore, in this study, the gas water heater(115S type Rheem products) that made in Germany and obtain hot water using gas as a heat source is selected. a $1.0m^3$ water tank with a 6kW electronic heater is installed and a water temperature and pressure is maintain constantly also thermometer is injected. Two of gas meter, one of pressure regulator and three of time measurement devices are installed in a combustion facility and fuelling facility with a magnet valve so it can observe and record combustion reactions. Quantity of hot water that heated by boiler is recorded using a quantity measurement tank, and have been heated by the boiler have been to record and measure the amount and utilized the data acquired through measurement of all factors that are applied to acquire hot water in order to calculate the use rate of final energy. In conclusion, this researcher drew the economic strong points of the hot water generated by gas.

실제조건에서 기준 밀도계와 가스 분석기에 의한 밀도 측정 결과 비교 (Density Measurement Comparisons of Specific Gravity Meter and Gas Chromatography in the Field)

  • 이강진;허재영;하영철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.90-96
    • /
    • 1999
  • In contracts for sales of natural gas between sellers and buyers, it is not suncient to only measure a volumetric quantity of gas in flowing conditions in metering station. Therefore the measured volumetric quantity must be converted to that of reference conditions. The density of the natural gas required in such a calculation can be measured directly or estimated from the equation of sate or any other experimental methods. The specific gravity meter is the apparatus used to measure the density of fluids under the reference conditions and it can be widely used in industrial areas, especially in massive flow rate natural gas industry. This study has been carried out in an attempt to improve measurement accuracy of natural gas flow rate calculation, providing the adequate installation and proper operation conditions of specific gravity meter. The test results are 1) the density measurement errors in case of using methane and standard gas as calibration gases are smaller than using methane and nitrogen gas, 2) the periodical calibration to maintain accurate density measurements is essential, and 3) the specific gravity meter is sensitive to changes of environmental conditions, especially environmental temperature surrounding the specific gravity meter.

  • PDF

인쇄물의 UCR, GCR 적용에 관한 연구 (A Study on Application of UCR, GCR in Printing)

  • 이철승;구철회
    • 한국인쇄학회지
    • /
    • 제22권2호
    • /
    • pp.83-100
    • /
    • 2004
  • In this paper, the quantity of dot gain in off-set printing is estimated by using the method of UCR(under color removal) and GCR(gray component replacement) and the degree of dot gain is researched through measurement of dot coverage of each color patch at the output film that is variously applied to discretionary quantity of dot gain each line in screen in the printing for the process of color separation and at the offset printing. Also, the best appropriate quantity of dot gain treatment is examined by printing each line in screen for reproduction of colors.

  • PDF