• 제목/요약/키워드: Quantitative visualization

검색결과 213건 처리시간 0.026초

화상 분석을 통한 선박 방오도료의 성능 평가 (Image Analysis Method for the Performance Evaluation of Marine Antifouling Coatings)

  • 박현;전호환;이인원
    • 한국가시화정보학회지
    • /
    • 제11권2호
    • /
    • pp.18-26
    • /
    • 2013
  • An accurate and reliable performance evaluation technique is indispensable for the development of marine antifouling coatings. The existing standard practice is however, based on the visual observation of biofouling settlement area, which is prone to the subjective judgment of the inspector. In spite of the above mentioned importance, a systematic and objective fouling evaluation technique has not yet been introduced. In this study, a novel quantitative antifouling performance evaluation method for marine antifouling paints is devised based on the image analysis of panel immersion test results. The present image analysis method is to quantify settlement area for each fouling category by distinctive color. The fouling categories are set as unfouled, biofilm, green algae, brown algae, calcareous animal and spongy animal with specific HSL (Hue, Saturation, Lightness) color ranges. In order to assess the effectiveness of the proposed method, static immersion tests for three antifouling coatings were undertaken for two years.

형광, 산란광 동시 촬열법을 이용한 가솔린 분무의 거동에 관한 연구 (Visualization of Gasoline Sprays Via a Simultaneous Inaging of Fluorescence and Scattering Lights)

  • 원영호
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.167-174
    • /
    • 1997
  • The penetration depth and the size distribution of the droplets of fuel sprays are important in the operation of spark-ignition MPI engines. A fluorescence/scattering image technique for droplet sizing was applied to measure th edroplet size distribution in non-evaporating gasoline sprays. The fluorescence and scattering lights were imaged simultaneously by the two-dimensional visualization system composed of a laser sheet, a doubling prism, optical filters, and a CCD camera. Quantitative droplet size distributions were extracted from evaluating the ratio of the two light densities. The mean droplet size measured by the fluorescence/scattering technique was compared with the result obtained by the enlarged photographs of droplets. The fluorescence/scattering image technique also gives the useful information of the characteristics of droplet impingement in a inclined wall.

  • PDF

소형 가솔린 가시화엔진의 내부유동 특성연구 (Characterization of In-Cylinder Flow of a Small Gasoline Optical Engine)

  • 김종선;정경석;정인석;조경국
    • 한국자동차공학회논문집
    • /
    • 제3권6호
    • /
    • pp.87-95
    • /
    • 1995
  • A commercial DOHC four valve engine was modified to make a single-cylinder optical model engine with replaceable head. Three kinds of head were used to generate swirl, tumble, and combined swirl/tumble motion. Schlieren visualization technique was applied to characterize the in-cylinder flow qualitatively. Particle Image velocimetry has been developed and applied for the quantitative flow measurements. Axial and tangential flow motion inside the cylinder has been characterized. The swirl/tumble port shows beneficial results in terms of turbulence generation for the initial flame propagation and mean swirl motion for the overall flame propagation.

  • PDF

미세 생체유동 해석을 위한 첨단 유동가시화기법 (Advanced Flow Visualization Techniques for Diagnosing Microscale Biofluid Flows)

  • 이상준
    • 대한기계학회논문집B
    • /
    • 제33권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Recently microscale biofluid flows have been receiving large attention in various research areas. However, most conventional imaging techniques are unsatisfactory due to difficulties encountered in the visualization of microscale biological flows. Recent advances in optics and digital image processing techniques have made it possible to develop several advanced micro-PIV/PTV techniques. They can be used to get quantitative velocity field information of various biofluid flows from visualized images of tracer particles. In this paper, as new advanced micro-PIV techniques suitable for biofluid flow analysis, the basic principle and typical applications of the time-resolved micro-PIV and X-ray micro-PIV methods are explained. As a 3D velocity field measurement technique for measuring microscale flows, holographic micro-PTV method is introduced. These advanced PIV/PTV techniques can be used to reveal the basic physics of various microscale biological flows and will play an important role in visualizing veiled biofluid flow phenomena, for which conventional methods have many difficulties to analyze.

Holographic tomography: hardware and software solutions for 3D quantitative biomedical imaging (Invited paper)

  • Kus, Arkadiusz;Krauze, Wojciech;Makowski, Piotr L.;Kujawinska, Malgorzata
    • ETRI Journal
    • /
    • 제41권1호
    • /
    • pp.61-72
    • /
    • 2019
  • In this paper, we demonstrate the current concepts in holographic tomography (HT) realized within limited angular range with illumination scanning. The presented solutions are based on the work performed at Warsaw University of Technology in Poland and put in context with the state of the art in HT. Along with the theoretical framework for HT, the optimum reconstruction process and data visualization are described in detail. The paper is concluded with the description of hardware configuration and the visualization of tomographic reconstruction, which is calculated using a provided processing path.

튜브 직경에 따른 과냉각 유동 내 단일 기포 응축의 영향 (Effect of a Tube Diameter on Single Bubble Condensation in Subcooled Flow)

  • 이선엽;;이재화
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.47-56
    • /
    • 2023
  • Bubble condensation, which involves the interaction of bubbles within the subcooled liquid flow, plays an important role in the effective control of thermal devices. In this study, numerical simulations are performed using a VOF (Volume of Fluid) model to investigate the effect of tube diameter on bubble condensation. As the tube diameter decreases, condensation bubbles persist for a long time and disappear at a higher position. It is observed that for small tube diameters, the heat transfer coefficients of condensation bubbles, which is a quantitative parameter of condensation rate, are smaller than those for large tube diameters. When the tube diameter is small, the subcooled liquid around the condensing bubble is locally participated in the condensation of the bubble to fill the reduced volume of the bubble due to the generation of a backflow in the narrow space between the bubble and the wall, so that the heat transfer coefficient decreases.

입자영상유속계에 의한 기포붐의 Plume 거동특성에 관한 연구 (A Study on Plume Movement Characteristics of Bubble Boom by PIV)

  • 조대환;오병주;이영호
    • 해양환경안전학회지
    • /
    • 제6권1호
    • /
    • pp.69-76
    • /
    • 2000
  • Bubble boom may be a good alternative for the prevention of oil spill pollution due to its easy deployment and clean post-process tasks. The present work is focused on the experimental investigation of air bubble movement for the bubble boom by visualization and quantitative PIV measurements. Bubble plume was generated by adjusting the pressure of pressure vessel ranging 6.7 kpa to 14.7 kpa. The results showed at lower inlet velocity and higher supply air flow rate that bubble boom maintained its containing capability reasonably well up to the maximum containing limit.

  • PDF

PIV를 이용한 평행평판 내의 혼합대류의 정량적 가시화 (A Quantitative Visualization of Mixed Convection in Parallel Plates Using PIV)

  • 박일용;배대석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.509-515
    • /
    • 2004
  • The PIV(Particle Image Velocimetry) with liquid crystal tracers is used for visualizing and analysis of the mixed convection in the parallel plates with the upper part cooled and the lower part heated. It is found that the flow pattern of mixed convection in the parallel plates can be classified into three patterns which was affected by Reynolds number. Also, the periodic nature is confirmed, and visualized in experiment.

Flow separator가 부착된 수직벽 후류유동의 실험적 연구 (Experimental study of vertical fence wake with flow separator)

  • 최영호;김형범
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.68-72
    • /
    • 2006
  • Vertical fence has the coherent flow structure in front of the fence. In the present study, the wake change due to the flow separator in front of the vertical fence was experimentally investigated. Quantitative method was applied to study the separated shear flow field. The results show the flow separator changes the downstream shear flow and alters the curvature of separated shear layer As the freestream velocity increased, the reattachment length also increased.

  • PDF

Optimizing the reconstruction filter in cone-beam CT to improve periodontal ligament space visualization: An in vitro study

  • Houno, Yuuki;Hishikawa, Toshimitsu;Gotoh, Ken-ichi;Naitoh, Munetaka;Mitani, Akio;Noguchi, Toshihide;Ariji, Eiichiro;Kodera, Yoshie
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.199-207
    • /
    • 2017
  • Purpose: Evaluation of alveolar bone is important in the diagnosis of dental diseases. The periodontal ligament space is difficult to clearly depict in cone-beam computed tomography images because the reconstruction filter conditions during image processing cause image blurring, resulting in decreased spatial resolution. We examined different reconstruction filters to assess their ability to improve spatial resolution and allow for a clearer visualization of the periodontal ligament space. Materials and Methods: Cone-beam computed tomography projections of 2 skull phantoms were reconstructed using 6 reconstruction conditions and then compared using the Thurstone paired comparison method. Physical evaluations, including the modulation transfer function and the Wiener spectrum, as well as an assessment of space visibility, were undertaken using experimental phantoms. Results: Image reconstruction using a modified Shepp-Logan filter resulted in better sensory, physical, and quantitative evaluations. The reconstruction conditions substantially improved the spatial resolution and visualization of the periodontal ligament space. The difference in sensitivity was obtained by altering the reconstruction filter. Conclusion: Modifying the characteristics of a reconstruction filter can generate significant improvement in assessments of the periodontal ligament space. A high-frequency enhancement filter improves the visualization of thin structures and will be useful when accurate assessment of the periodontal ligament space is necessary.