• 제목/요약/키워드: Quantitative parameters

검색결과 1,130건 처리시간 0.033초

뇌 PET 영상 정량화 및 파라메터영상 구성을 위한 선형분석기법 (Linearized Methods for Quantitative Analysis and Parametric Mapping of Brain PET)

  • 김수진;이재성
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권2호
    • /
    • pp.78-84
    • /
    • 2007
  • Quantitative analysis of dynamic brain PET data using a tracer kinetic modeling has played important roles in the investigation of functional and molecular basis of various brain diseases. Parametric imaging of the kinetic parameters (voxel-wise representation of the estimated parameters) has several advantages over the conventional approaches using region of interest (ROI). Therefore, several strategies have been suggested to generate the parametric images with a minimal bias and variability in the parameter estimation. In this paper, we will review the several approaches for parametric imaging with linearized methods which include graphical analysis and mulilinear regression analysis.

경계선 검출 성능에 영향을 주는 변수 변화에 따른 경계선 검출 알고리듬 성능의 정량적인 평가 방법 (A Method for Quantitative Performance Evaluation of Edge Detection Algorithms Depending on Chosen Parameters that Influence the Performance of Edge Detection)

  • 양희성;김유호;한정현;이은석;이준호
    • 한국통신학회논문지
    • /
    • 제25권6B호
    • /
    • pp.993-1001
    • /
    • 2000
  • This research features a method that quantitatively evaluates the performance of edge detection algorithms. Contrary to conventional methods that evaluate the performance of edge detection as a function of the amount of noise added to he input image, the proposed method is capable of assessing the performance of edge detection algorithms based on chosen parameters that influence the performance of edge detection. We have proposed a quantitative measure, called average performance index, that compares the average performance of different edge detection algorithms. We have applied the method to the commonly used edge detectors, Sobel, LOG(Laplacian of Gaussian), and Canny edge detectors for noisy images that contain straight line edges and curved line edges. Two kinds of noises i.e, Gaussian and impulse noises, are used. Experimental results show that our method of quantitatively evaluating the performance of edge detection algorithms can facilitate the selection of the optimal dge detection algorithm for a given task.

  • PDF

Dynamic fracture instability in brittle materials: Insights from DEM simulations

  • Kou, Miaomiao;Han, Dongchen;Xiao, Congcong;Wang, Yunteng
    • Structural Engineering and Mechanics
    • /
    • 제71권1호
    • /
    • pp.65-75
    • /
    • 2019
  • In this article, the dynamic fracture instability characteristics, including dynamic crack propagation and crack branching, in PMMA brittle solids under dynamic loading are investigated using the discrete element method (DEM) simulations. The microscopic parameters in DEM are first calibrated using the comparison with the previous experimental results not only in the field of qualitative analysis, but also in the field of quantitative analysis. The calibrating process illustrates that the selected microscopic parameters in DEM are suitable to effectively and accurately simulate dynamic fracture process in PMMA brittle solids subjected to dynamic loads. The typical dynamic fracture behaviors of solids under dynamic loading are then reproduced by DEM. Compared with the previous experimental and numerical results, the present numerical results are in good agreement with the existing ones not only in the field of qualitative analysis, but also in the field of quantitative analysis. Furthermore, effects of dynamic loading magnitude, offset distance of the initial crack and initial crack length on dynamic fracture behaviors are numerically discussed.

단일광자방출 전산화단층촬영상에서 재구성 필터에 의한 정량화 오차에 관한 연구 (A Study on the Quantification Error due to the Reconstruction Filters in Single Photon Emission Computed Tomography(SPECT))

  • 곽철은;정준기
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권1호
    • /
    • pp.43-48
    • /
    • 1991
  • As the computerized methods and equipments In nuclear medicine imaging increases, quantitative information is needed on the single photon emission computed tomographic Images as well as on the conventional nuclear medicine images. In this paper, the authors investigated the effect of several clinician - friendly reconstrution filters on the resultant transverse slices of backprojected Profiles of radioisotope distribution from the Quantitative point of view, and reduced the filter parameters such as cutoff frequency and order of filter which are neces mary to minimize the quantification error using computer-generated phantoms.

  • PDF

병원 종합관리 시스템

  • 조규달
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권1호
    • /
    • pp.51-54
    • /
    • 1982
  • As the computerized methods and equipments in nuclear medicine imaging increases, quantitative information is needed on the single photon emission computed tomographic images as well as on the conventional nuclear medicine images. In this paper, the authors investigated the effect of several clinician - friendly reconstrution filters on the resultant transverse slices of backprojected profiles of radioisotope distribution from the quantitative point of view, and reduced the filter Parameters such as cutoff frequency and order of filter which are necessary to minimize the quantification error using computer -generated phantoms.

  • PDF

Rubbing Process Evaluation Method for The LCD Panel

  • Honoki, Hideyuki;Sakai, Kaoru;Kawabe, Shun'Ichi;Nakasu, Nobuaki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.115-117
    • /
    • 2002
  • In order to realize a stable rubbing process for the liquid crystal panel, the authors investigated the quantitative evaluation method of rubbing process uniformity. The proposed method focuses on the relationship between the image quality of the LCD panel for gray scale images and the rubbing uniformity. The proposed method indicates rubbing uniformity using quantitative parameters of spots and hairlines on the LCD panel.

  • PDF

Cone-beam computed tomography texture analysis can help differentiate odontogenic and non-odontogenic maxillary sinusitis

  • Andre Luiz Ferreira Costa;Karolina Aparecida Castilho Fardim;Isabela Teixeira Ribeiro;Maria Aparecida Neves Jardini;Paulo Henrique Braz-Silva;Kaan Orhan;Sergio Lucio Pereira de Castro Lopes
    • Imaging Science in Dentistry
    • /
    • 제53권1호
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: This study aimed to assess texture analysis(TA) of cone-beam computed tomography (CBCT) images as a quantitative tool for the differential diagnosis of odontogenic and non-odontogenic maxillary sinusitis(OS and NOS, respectively). Materials and Methods: CBCT images of 40 patients diagnosed with OS (N=20) and NOS (N=20) were evaluated. The gray level co-occurrence (GLCM) matrix parameters, and gray level run length matrix texture (GLRLM) parameters were extracted using manually placed regions of interest on lesion images. Seven texture parameters were calculated using GLCM and 4 parameters using GLRLM. The Mann-Whitney test was used for comparisons between the groups, and the Levene test was performed to confirm the homogeneity of variance (α=5%). Results: The results showed statistically significant differences(P<0.05) between the OS and NOS patients regarding 3 TA parameters. NOS patients presented higher values for contrast, while OS patients presented higher values for correlation and inverse difference moment. Greater textural homogeneity was observed in the OS patients than in the NOS patients, with statistically significant differences in standard deviations between the groups for correlation, sum of squares, sum of entropy, and entropy. Conclusion: TA enabled quantitative differentiation between OS and NOS on CBCT images by using the parameters of contrast, correlation, and inverse difference moment.

Biochemical Performance and Quantitative Assessment of F1 Hybrid of Two Ecoraces of Tropical Tasar Silkworm Antheraea Mylitta Drury (Lepidoptera: Saturniidae)

  • Lokesh, Gangadharaiah;Tirkey, Sushma Rani;Srivastava, Ashok Kumar;Kar, Prasant Kumar;Sinha, Manoj Kumar
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제26권2호
    • /
    • pp.67-73
    • /
    • 2013
  • Antheraea mylitta Drury is basically a crossbreeding species, as such it seems to be potentially a good material for the exploitation of heterosis. In the present study F1 hybrid of wild ecorace Laria (L) and semi-domestic Daba (D) was raised and evaluated for various quantitative traits and biochemical parameters during larval stage. Improved fecundity ($+18{\pm}1.8%$ and higher egg hatching rate ($+10.96{\pm}1.3%$) was recorded in the F1hybrid ($L{\times}D$). Biochemical parameters studied in the hemolymph, midgut and fatbody of the larva showed significantly higher (P<0.05) total proteins and carbohydrate concentration besides digestive enzyme activity. Correspondingly SDS-PAGE revealed more number of protein bands in the hemolymph sample of F1s, ranging between 29 kDa to 66 kDa compared to parental lines. The present study demonstrates the positive heterosis effect in the F1 hybrid of Laria ${\times}$ Daba. Biochemical analysis indicates that, there is possibilities of exploitation of hybrids with specific parents targeted for desirable commercial traits (silk yield and fecundity). Moreover, most of these biochemical parameters can be used as markers to analyze the genetic improvement in the tasar silkworms.