• Title/Summary/Keyword: Quantitative and Objective

Search Result 1,520, Processing Time 0.027 seconds

Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging

  • Ji Young Choi;Jihye Yun;Subin Heo;Dong Wook Kim;Sang Hyun Choi;Jiyoung Yoon;Kyuwon Kim;Kee Wook Jung;Seung-Jae Myung
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1093-1101
    • /
    • 2023
  • Objective: Cine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from cine MRI and evaluate its performance in a population with varying degrees of small bowel motility. Materials and Methods: A total of 174 participants (28.5 ± 7.6 years; 135 males) underwent a 22-second-long cine MRI sequence (2-dimensional balanced turbo-field echo; 0.5 seconds per image) approximately 5 minutes after being intravenously administered 10 mg of scopolamine-N-butyl bromide to deliberately create diverse degrees of small bowel motility. In a manually segmented area of the small bowel, motility was automatically quantified using a nonrigid registration and calculated as a quantitative motility score. The mean value (MV) of motility grades visually assessed by two radiologists was used as a reference standard. The quantitative motility score's correlation (Spearman's ρ) with the reference standard and performance (area under the receiver operating characteristics curve [AUROC], sensitivity, and specificity) for diagnosing adynamic small bowel (MV of 1) were evaluated. Results: For the MV of the quantitative motility scores at grades 1, 1.5, 2, 2.5, and 3, the mean ± standard deviation values were 0.019 ± 0.003, 0.027 ± 0.010, 0.033 ± 0.008, 0.032 ± 0.009, and 0.043 ± 0.013, respectively. There was a significant positive correlation between the quantitative motility score and the MV (ρ = 0.531, P < 0.001). The AUROC value for diagnosing a MV of 1 (i.e., adynamic small bowel) was 0.953 (95% confidence interval, 0.923-0.984). Moreover, the optimal cutoff for the quantitative motility score was 0.024, with a sensitivity of 100% (15/15) and specificity of 89.9% (143/159). Conclusion: The quantitative motility score calculated from a cine MRI enables diagnosis of an adynamic small bowel, and potentially discerns various degrees of bowel motility.

Objective and Quantitative Evaluation of Image Quality Using Fuzzy Integral: Phantom Study (퍼지적분을 이용한 영상품질의 객관적이고 정량적 평가: 팬톰 연구)

  • Kim, Sung-Hyun;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.201-208
    • /
    • 2008
  • Physical evaluations provide the basis for an objective and quantitative analysis of the image quality. Nonetheless, there are limitations in using physical evaluations to judge the utility of the image quality if the observer's subjectivity plays a key role despite its imprecise and variable nature. This study proposes a new method for objective and quantitative evaluation of image quality to compensate for the demerits of both physical and subjective image quality and combine the merits of them. The images of chest phantom were acquired from four digital radiography systems on clinic sites. The physical image quality was derived from an image analysis algorithm in terms of the contrast-to-noise ratio (CNR) of the low-contrast objects in three regions (lung, heart, and diaphragm) of a digital chest phantom radiograph. For image analysis, various image processing techniques were used such as segmentation, and registration, etc. The subjective image quality was assessed by the ability of the human observer to detect low-contrast objects. Fuzzy integral was used to integrate them. The findings of this study showed that the physical evaluation did not agree with the subjective evaluation. The system with the better performance in physical measurement showed the worse result in subjective evaluation compared to the other system. The proposed protocol is an integral evaluation method of image quality, which includes the properties of both physical and subjective measurement. It may be used as a useful tool in image evaluation of various modalities.

  • PDF

Literature Review on One.Handed Manual Material Handling (한손 수동물자취급에 관한 문헌 조사)

  • Mo, Seung-Min;Kwag, Jong-Seon;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.5
    • /
    • pp.819-829
    • /
    • 2010
  • By referring thirty-seven previous studies on manual material handling (MMH), this paper analyzed guidelines and main factors of one-handed tasks. The previous studies concerned main factors of distance, weight, frequency, posture, gender, age, training, direction of force, height of the force exerted, and object shape and size. Based on these factors, the criteria used to understand one-handed tasks were objective measures of maximum strength, reaction force, etc., psychophysical measures of maximum acceptable frequency and weight, etc., and physiological measures of oxygen uptake, heart rate, electromyography, etc. An allowance threshold model regarding quantitative and objective fatigue and workload would be suggested for future research. This study would be expected that it serve to establish and Korean recommendations of one-handed tasks.

The Standard Thesis of Objectivity Condition Evaluation for Infrastructure(Retaining Walls) (옹벽 시설물의 객관적인 상태평가 기준정립)

  • 이종영;신창건;장범수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.06a
    • /
    • pp.3.1-11
    • /
    • 2003
  • Recently the problems related to the failure of the retaining wall structure has become great concern since the damage to the properties and human losses have occurred in the rainy season. However, a detail guideline on safety inspection and appropriate diagnosis on the retaining wall structure have not yet proposed and therefore, the inspection process and results are mainly dependant upon the engineers. The objective of this study is to propose objective and quantitative evaluation method for the condition based on the damage shapes and material types. In this purpose, composing materials of retaining wall are divided Into concrete, gabion, stone and reinforced earth, and then the evaluation items and method are suggested on the basis of the materials and structural characteristics of the retaining wall.

  • PDF

Comparison of Outlines by Image Analysis for Derivation of Objective Validation Results: "Ito Hirobumi's Characters on the Foundation Stone" of the Main Building of Bank of Korea (이미지 분석법을 활용한 형상정보의 비교와 객관적 검증결과의 도출사례: 한국은행 본관 정초석 '이토 히로부미 글씨'의 검증)

  • Yoo, Woo Sik
    • Journal of Conservation Science
    • /
    • v.36 no.6
    • /
    • pp.511-518
    • /
    • 2020
  • There have been reports that the "jeongcho (定礎)" letters of the foundation stone at the historical site No. 280 of the "Main Building of the Bank of Korea in Seoul" were written by Prince Ito Hirobumi (伊藤博文), the first Resident-General of Japan in Korea. An on-site investigation by an advisory group consisting of three experts in calligraphy; revealed that the two characters of '定礎' inscribed on the foundation stone are the characteristics of Ito Hirobumi's handwriting, judging from the writing style and habits observed in the collections of the Central Library of Hamamatsu City, Japan. It was reported that his writing was confirmed by the experts, but no basis was provided. To provide more objective and quantitative supporting data, rather than qualitative judgment based on feeling, it is necessary to present the basis for judgment through quantitative image comparison results through image analysis. In this paper, using image analysis software, Ito Hirobumi's calligraphy writing and the inscribed characters of the foundation stone were compared and analyzed to confirm the contents of the press release. The character comparison process and character area measurement results are a good example showing that if objective judgment basis data are needed in a similar situation, an objective judgment basis can be prepared through quantification using image analysis.

A study on the evaluation of electronic security systems using the AHP (AHP를 이용한 전자경비 시스템의 평가에 관한 연구)

  • 정호원;강인배
    • Korean Management Science Review
    • /
    • v.13 no.2
    • /
    • pp.49-59
    • /
    • 1996
  • The use of advanced electronic security system is growing quickly to protect properties and life. However, customers cannot select appropriate configuration of the system because there are no objective evaluation methods to measure the security ability of the system. Furthermore, the system suppliers cannot propose quantitative value of security ability of the system. This study suggests an objective evaluation and selection method that customers and suppliers can use to base his or her decision when choosing the most appropriate configuration of the system. Our method identifies 6 characteristics and 20 sub- characteristics of the electronic security system, calculates their weights, and decides the best configuration. We use AHP (Analytic Hierarchy Process) to assign the weights of characteristics. Finally, this paper gives an example to compare four alternative configurations of the system.

  • PDF

Review on Subjective and Objective Assessments of Ride Comfort, Handling and Steering Feeling (승차감과 조종성능의 정량·정성 지표 상관성 연구 리뷰)

  • Kim, Hyungjun;Han, Jihyuck;Yang, Ji Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.59-66
    • /
    • 2016
  • The evaluations of ride comfort, handling, and steering feeling have been known as one of the dominant factors for vehicle performance assessment. However, those factors have not been analyzed in-depth in conjunction with general ride and handling design parameters. Thus, we have surveyed some previous studies dealing with subjective parameters and quantitative design parameters. We expect this paper provides some guidance to the future research on the field.

COMPARATIVE STUDY ON PANEER MAKING FROM BUFFALO AND COW MILK

  • Masud, T.;Athar, I.H.;Shah, M.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.3
    • /
    • pp.563-565
    • /
    • 1992
  • The objective of this study is to compare the qualitative and quantitative properties of paneer prepared from buffalo and cow milk. Paneer from buffalo milk had higher total solids as compared to cow. Moreover significant differences were recorded in fat and protein contents among tested samples of milk, cheese and whey respectively. The results of the organoleptic evaluations showed that paneer made from cow milk was liked more as compared to buffalo.

A Study on the Quantitative Human Visual Preference with PDP and LCD

  • Lee, Hwal-Ly;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1143-1146
    • /
    • 2007
  • We carried out the human visual evaluation on PDPs and LCDs to clarify the viewer preference and the related physical and physiological factors. In the subjective evaluation, the impression test using the semantic differential method was carried out. In the objective evaluation, the eye motion tracking system was used. Our study showed that considering the real usage, the optimum display for viewers was that which showed more soft and smooth image without blurring.

  • PDF

Quantitative Analysis of Thyroid Blood Flow and Static Imaging in the Differential Diagnosis of Thyroid Nodules

  • Song, Li-Ping;Zhang, Wen-Hong;Xiang, Yang;Zhao, Na
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6331-6335
    • /
    • 2013
  • Objective:To evaluate the performance of combined quantitative analysis of thyroid blood flow and static imaging data in the differential diagnosis of thyroid nodules. Method: Thyroid blood flow and static imaging were performed in 165 patients with thyroid nodules. Patients were divided into a benign thyroid nodule group (BTN, n=135) and a malignant thyroid nodule group (MTN, n=30) based on the results of post-surgical pathologic examination. Carotid artery thyroid transit times (CTTT), perfusion ratio of thyroid nodule blood/thyroid blood (TNB/TB), and perfusion ratio of thyroid nodule blood/carotid artery blood (TNB/CAB) were measured using thyroid blood flow imaging. The ratios between thyroid nodule and ipsilateral submandibular gland (TN/SG) and thyroid nodule and normal thyroid tissue (TN/T) were measured from thyroid static imaging. The differences between the BTN and MTN groups were compared. Results: 1) CTTT was markedly lower in the MTN group than the BTN group, the difference being statistically significant. 2) TNB/TB and TNB/CAB were both significantly higher in MTN than BTN groups. 3) TN/T was significantly lower in MTN group than BTN group. 4) TN/SG was lower in MTN group than BTN group, but the difference was not statistically significant. 5) Using the combination of CTTT and TN/T, the sensitivity, specificity and accuracy were 93.1%, 95.3% and 94.9% respectively for the diagnosis of MTN. Using the combination of CTTT, TNB/TB and TN/T, the sensitivity, specificity and accuracy changed to 89.7%, 100%, and 98.1% respectively. 6) Correlation analysis demonstrated a significant correlation between TN/T and TNB/TB (r=-0.384, P=0.036) and TNB/CAB (r=-0.466, P=0.009) in the MTN group. Conclusion: The combination of quantitative markers from thyroid blood flow and thyroid static imaging had high specificity and accuracy in differential diagnosis of benign and malignant thyroid nodules, thus providing an important imaging diagnostic approach.