• Title/Summary/Keyword: Quantitative CT

검색결과 339건 처리시간 0.02초

전산화단층영상을 이용한 복부 지방 계측법에서 호흡운동이 비만도 측정에 미치는 영향 (Obesity Estimation of Abdominal Fat by Using Computed Tomography : Influence of Breathing Motion on The Fat Measurement)

  • 성열훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권1호
    • /
    • pp.8-14
    • /
    • 2012
  • The purpose of this study was to evaluate how much effect to accuracy when measuring abdominal fat by Computed Tomography (CT) under different respiration movements. The study volunteer composed of 66 normal adults ($50.4{\pm}11.2$ years, 33 males, 33 females). We measured their obesity by using Broca index, body mass index (BMI) and CT and have investigated the correlation. The CT scanning for the obesity measurement have done in two ways, one was done in stopping breath after exhaling and the other was holding a breath after inhaling. The results showed no statistically significant difference among the three measuring techniques. And, the error in two ways of inhaling and exhaling was showed 24.2% of volunteers. The two ways of respiration movements made different result in visceral fat area (P = 0.044), subcutaneous fat area (P = 0.636) and abdominal obesity value (P = 0.012). This study demonstrates that the two ways of respiration movements when scanning CT makes change in accuracy in visceral fat area, and in abdominal obesity quantitative measure. Therefore, our study suggests that CT should take twice in two ways while a patient stops breath after exhaling and holds a breath after inhaling when measuring abdominal obesity using CT equipments.

환자 대장 CT 프로파일을 이용한 전자적 장세척 방법 (An Electronic Colon Cleansing Method using a Patient Colon CT Profile)

  • 김한별;김동성
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제35권8호
    • /
    • pp.493-500
    • /
    • 2008
  • 가상 대장 내시경을 위해서 환자 대장 CT 프로파일을 이용한 전자적 장세척 방법을 제안한다. 제안된 방법은 관강 영역을 cubic seeded region growing(SRG) 방법을 이용하여 추출하고, 이에 인접한 tagged material(TM)을 제거한다. TM의 경계에서 Air-TM의 partial volume(PV) 효과로 발생한 찌꺼기를 제거하고, TM-soft tissue(ST)의 PVE에 의해서 제거된 ST는 환자 CT 프로파일을 이용해서 복원한다. 제안된 방법을 16명의 가상 내시경 환자 CT 데이타에 적용해서 임상의의 주관적인 평가와 computer-aided diagnosis(CAD)의 정량적 평가에서 매우 고무적인 결과를 획득했다.

PET/CT 팬텀의 3D 프린팅 소재 적용 가능성 평가 (Evaluation of the Applicability of PET/CT Phantom as a 3D Printing Material)

  • 이주영;김지현;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.423-431
    • /
    • 2022
  • The purpose of this study is to present objective information in applying 3D printing technology for PET/CT (Positron Emission Tomography/Computed Tomography) performance evaluation and use it as a basic research that can be applied to various purposes in the future. Phantoms were manufactured with step wedge of ABS(Acrylonitrile Butadiene Styrene) and ACR(Acrylic acid) material. The counts for each ROI(Region of Interest) were analyzed through image acquisition in PET/CT. And the variation rate of counts and CNR(Contrast Noise Ratio) was evaluated. In the counts analysis, the effect of thickness occurred. In addition, in the variation rate analysis, the thickness setting of steps wedge 4 to 5 levels should be considered first. These results minimize quantitative and qualitative changes in the phantom manufactured based on 3D printing, and enable more stable PET/CT performance evaluation. Based on 3D printing in PET/CT, various phantoms are expected to be produced in the future. If the characteristics of each material are considered and applied through the basic research such as this research, the result of the phantom manufactured through 3D printing can be more meaningful and will be used in a wide range.

Effects of Cardiovascular Training on Interleukin-6 in Stroke Patients: a Systematic Review and Meta-analysis of Randomized Controlled Trials

  • Jeong Keun Song;Ju Hui Moon
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권2호
    • /
    • pp.115-122
    • /
    • 2023
  • Objective: A previous study reported that cardiovascular training (CT) decreased interleukin-6 (IL-6), a pro-inflammatory cytokine with bidirectional effects. However, because of conflicting results of increasing and decreasing IL-6 levels in stroke patients, it is essential to clarify the effects of CT on IL-6 levels in this population. Therefore, this review aimed to investigate the effects of CT on IL-6 levels in stroke patients through a meta-analysis of randomized controlled trials (RCTs), synthesizing and analyzing the effects qualitatively and quantitatively. Design: A systematic review and meta-analysis of randomized controlled trials. Methods: In this review, conducted in April 2023, electronic databases (Web of Science, CINAHL, Embase, MEDLINE, Google Scholar) were searched to ascertain the effects of CT on IL-6 levels in stroke patients. For qualitative evaluation, ReVMan, provided by the Cochrane Group, was used, and for quantitative evaluation, a random-effects model and SMD (Standardized Mean Difference) were used. Results: Three RCTs measured IL-6 in 117 patients with stroke. The experimental group to which CT was applied showed no significant change compared to the control group.The result of analysis using the random effect model is SMD=-0.23; 95% confidence interval, -0.66 to 0.20. Conclusions: CT does not affect IL-6 levels in stroke patients. These results suggest that CT can be applied regardless of its positive or negative effect on IL-6 levels in stroke patients.

Fatty Liver 환자의 컴퓨터단층촬영 영상을 이용한 질감특징분석 (Texture Feature analysis using Computed Tomography Imaging in Fatty Liver Disease Patients)

  • 박형후;박지군;최일홍;강상식;노시철;정봉재
    • 한국방사선학회논문지
    • /
    • 제10권2호
    • /
    • pp.81-87
    • /
    • 2016
  • 본 실험에서 제안된 질감특징분석 알고리즘은 지방간 환자의 CT영상을 이용하여 정상영상과 질환영상으로 구분하여, 정상 간 CT영상과 지방간 CT영상을 생성하고 제안된 질감특징분석을 이용한 컴퓨터보조 진단 시스템에 적용하여 6개의 파라메타로 정량적 분석을 통해 지방간 CT영상의 질환 인식률을 도출하고 평가하였다. 결과로 지방간 CT영상 30증례 중에서 각각의 파라메타별 질감특징 값에 대한 인식률은 평균 밝기의 경우 100%, 엔트로피의 경우 96.67%, 왜곡도의 경우 93.33%로 높게 나타났고, 평탄도의 경우 83.33%, 균일도의 경우 86.67%, 평균대조도의 경우 80%로 다소 낮은 질환 인식률을 보였다. 따라서 본 연구의 결과를 바탕으로 의료영상의 컴퓨터보조진단 시스템으로 발전된 프로그램을 구현한다면 지방간 CT영상의 질환부위 자동검출 및 정량적 진단이 가능해 컴퓨터보조진단 자료로서 활용이 가능할 것으로 판단되며 최종판독에서 객관성, 정확성, 판독시간 단축에 유용하게 사용 될 것으로 사료된다.

PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향 (The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media)

  • 안샤론;박훈희;박민수;오신현;이승재;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.77-81
    • /
    • 2009
  • PET/CT (Positron Emission Tomography/ Computed Tomography)의 PET은 생체의 생리, 화학적인 정보를 정량적으로 영상화할 수 있지만 해부학적인 구조를 명확히 나타내는 데에는 한계를 가지고 있어 PET에 CT를 접목시켜 해상력을 높임은 물론, CT 데이터를 감쇠보정에 이용하여 촬영시간도 단축시키고 잡음제거 측면에서도 우수함을 나타내고 있다. 또한 CT 검사 시 조영제를 사용함으로써 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 용이하여 조영제의 사용이 증가하고 있는 추세이다. 하지만 조영제를 사용한 경우 CT 영상의 보정에 따라 PET/CT 영상에서 표준화섭취계수(Standardized Uptake Value: SUV)에 영향을 미치기 때문에 본 연구에서는 조영제 보정에 따라 표준화섭취계수(SUV)에 미치는 정도를 평가하였다. 2008년 4월에서 7월 사이에 본원에서 PET/CT검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 환자 30명을 대상으로 (남: 20, 여: 10, 연령범위: 연령범위 27세~72세, 평균나이 49.6세) 후향적 조사를 하였다. 장비는 DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하였다. 검사자에게 $^{18}F$-FDG 370~555 MBq를 몸무게에 따라 주사하였으며, 1시간 정도의 안정된 자세를 취한 후 검사를 시행하였다. CT촬영은 140 kV, 210 mA로 설정하였으며 CT 검사에 사용되는 조영제의 양은 환자 몸무게 1 kg당 2 cc를 주입하였다. 검사 후 최초 획득 데이터(raw data)를 이용하여 조영제 영향을 보정한 CT데이터와 보정을 하지 않은 CT데이터로 감쇠보정을 하여 영상을 얻었으며 각 영상의 간, 심장, 폐에 관심영역(Region of Interest: ROI)를 그려 SUV를 측정하여 비교하였다. SUV를 측정한 결과 조영제 보정을 한 영상의 표준화섭취계수(SUV)가 줄어듦을 알 수 있었다. 조영제에 대한 영향이 거의 없는 폐에서는 수치적인 변화가 거의 나타나지 않았으며 통계적으로도 유의하지 않았다. 비교적 혈류가 풍부한 간과 심장에서 조영제 보정으로 인한 표준화 섭취계수(SUV) 값이 수치적인 차이를 보였으나 간에서만 통계적으로 유의했다. PET/CT 검사에서 조영제의 사용으로 인하여 검사하고자 하는 부위의 대조도를 증강시켜 진단의 효율성을 높이고 있지만 이로 인하여 표준화섭취계수(SUV)의 증가가 일어난다. 따라서 조영제를 사용한 CT로 감쇠보정을 할 경우에 조영제의 영향에 대한 보정을 해주어 고해상력의 해부학적 영상뿐만 아니라 신뢰를 할 수 있는 반정량적 방법으로 진단적 가치를 더욱 높일 수 있을 것이며 다른 장기에 대해서도 추가적인 연구가 필요하다고 생각된다.

  • PDF

Prediction of Pulmonary Function in Patients with Chronic Obstructive Pulmonary Disease: Correlation with Quantitative CT Parameters

  • Hyun Jung Koo;Sang Min Lee;Joon Beom Seo;Sang Min Lee;Namkug Kim;Sang Young Oh;Jae Seung Lee;Yeon-Mok Oh
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.683-692
    • /
    • 2019
  • Objective: We aimed to evaluate correlations between computed tomography (CT) parameters and pulmonary function test (PFT) parameters according to disease severity in patients with chronic obstructive pulmonary disease (COPD), and to determine whether CT parameters can be used to predict PFT indices. Materials and Methods: A total of 370 patients with COPD were grouped based on disease severity according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) I-IV criteria. Emphysema index (EI), air-trapping index, and airway parameters such as the square root of wall area of a hypothetical airway with an internal perimeter of 10 mm (Pi10) were measured using automatic segmentation software. Clinical characteristics including PFT results and quantitative CT parameters according to GOLD criteria were compared using ANOVA. The correlations between CT parameters and PFT indices, including the ratio of forced expiratory volume in one second to forced vital capacity (FEV1/FVC) and FEV1, were assessed. To evaluate whether CT parameters can be used to predict PFT indices, multiple linear regression analyses were performed for all patients, Group 1 (GOLD I and II), and Group 2 (GOLD III and IV). Results: Pulmonary function deteriorated with increase in disease severity according to the GOLD criteria (p < 0.001). Parenchymal attenuation parameters were significantly worse in patients with higher GOLD stages (P < 0.001), and Pi10 was highest for patients with GOLD III (4.41 ± 0.94 mm). Airway parameters were nonlinearly correlated with PFT results, and Pi10 demonstrated mild correlation with FEV1/FVC in patients with GOLD II and III (r = 0.16, p = 0.06 and r = 0.21, p = 0.04, respectively). Parenchymal attenuation parameters, airway parameters, EI, and Pi10 were identified as predictors of FEV1/FVC for the entire study sample and for Group 1 (R2 = 0.38 and 0.22, respectively; p < 0.001). However, only parenchymal attenuation parameter, EI, was identified as a predictor of FEV1/FVC for Group 2 (R2 = 0.37, p < 0.001). Similar results were obtained for FEV1. Conclusion: Airway and parenchymal attenuation parameters are independent predictors of pulmonary function in patients with mild COPD, whereas parenchymal attenuation parameters are dominant independent predictors of pulmonary function in patients with severe COPD.

Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method

  • Pamela Sung;Jeong Min Lee;Ijin Joo;Sanghyup Lee;Tae-Hyung Kim;Balaji Ganeshan
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.558-568
    • /
    • 2019
  • Objective: To evaluate whether computed tomography (CT) reconstruction algorithms affect the CT texture features of the liver parenchyma. Materials and Methods: This retrospective study comprised 58 patients (normal liver, n = 34; chronic liver disease [CLD], n = 24) who underwent liver CT scans using a single CT scanner. All CT images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR) (iDOSE4), and model-based IR (IMR). On arterial phase (AP) and portal venous phase (PVP) CT imaging, quantitative texture analysis of the liver parenchyma using a single-slice region of interest was performed at the level of the hepatic hilum using a filtration-histogram statistic-based method with different filter values. Texture features were compared among the three reconstruction methods and between normal livers and those from CLD patients. Additionally, we evaluated the inter- and intra-observer reliability of the CT texture analysis by calculating intraclass correlation coefficients (ICCs). Results: IR techniques affect various CT texture features of the liver parenchyma. In particular, model-based IR frequently showed significant differences compared to FBP or hybrid IR on both AP and PVP CT imaging. Significant variation in entropy was observed between the three reconstruction algorithms on PVP imaging (p < 0.05). Comparison between normal livers and those from CLD patients revealed that AP images depend more strongly on the reconstruction method used than PVP images. For both inter- and intra-observer reliability, ICCs were acceptable (> 0.75) for CT imaging without filtration. Conclusion: CT texture features of the liver parenchyma evaluated using the filtration-histogram method were significantly affected by the CT reconstruction algorithm used.

CT와 $^{68}Ge$ 감쇠보정 $^{18}F-FDG$ PET 영상의 정량적 비교: 측정감쇠보정대 분할감쇠보정 (Quantitative Comparisons between CT and $^{68}Ge$ Transmission Attenuation Corrected $^{18}F-FDG$ PET Images: Measured Attenuation Correction vs. Segmented Attenuation Correction)

  • 최준영;우상근;최용;최연성;이경한;김병태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권1호
    • /
    • pp.49-53
    • /
    • 2007
  • 목적: CT를 사용한 측정감쇠보정(measured attenuation correction; CT-MAC) PET 영상은 $^{68}Ge$을 사용한 분할감쇠보정(segmented attenuation correction; Ge-SAC) PET 영상보다 섭취값이 높은 것으로 알려져 있다. 이 연구에서는 정상인과 암으로 진단된 또는 암이 의심되는 환자를 대상으로 $^{18}F-FDG$ PET을 시행하고, 감쇠보정방법을 달리하여 각각 4가지 PET 영상을 얻고 이를 서로 정량적으로 비교하였다. 대상 및 방법: 5명의 정상인(남:여=4:1; 평균나이, $29.4{\pm}2.5$세)과 35명의 환자(남17, 여18; 평균나이 $52.7{\pm}15.2$세)를 대상으로 $^{18}F-FDG$ PET을 시행하였다. 먼저, CT 영상(140 KeV, 80 mAs)을 얻은 뒤 방출영상(5 min/bed)과 $^{68}Ge$ 투과영상(3 min/bed)을 차례로 얻었다. Ordered subsets expectation maximization (28 subsets, 2 iterations) 영상재구성법과 CT-MAC, CT-SAC, Ge-MAC, Ge-SAC의 4가지 감쇠보정방법을 사용하여 4가지 PET 영상을 얻었다. 정상인군에서는 대표적인 정상조직의, 환자군에서는 비정상적인 섭취를 보이는 병소의 SUV를 구하고, 이를 서로 비교 하였다. 결과: 정상인 군에서 CT-MAC 사용하여 감쇠보정한 PET 영상의 18개 정상조직의 SUV는 나머지 3가지 종류의 PET 영상에 비하여 모두 유의하게 높았다($3.1%{\sim}4.1%$; p<0.001). 환자군에서는 총 145개 병소의 국소 FDG 섭취증가 병변이 발견되었다. CT-MAC 사용한 PET 영상의 SUV 값은 나머지 3가지 PET 영상에 비하여 모두 유의하게 높았다($2.4%{\sim}5.1%$; p<0.001). Ge-MAC 사용한 PET 영상의 SUV 값은 CT-SAC와 Ge-SAC 사용한 PET 영상에 비하여 유의하게 높았다(p<0.001). 그러나, CT-SAC와 Ge-SAC PET 영상사이의 SUV에는 유의한 차이가 없었다. 폐병변에서는 감쇠보정방법사이에 섭취값이 유의한 차이가 없는 반면, 뼈병변에서는 이러한 차이가 가장 컸다($3.8%{\sim}9.6%$; p<0.01). 결론: $^{18}F-FDG$ PET 영상에서 섭취값은 CT-MAC로 감쇠보정을 했을 때에 가장 높다. CT 감쇠보정 및 MAC 사용, 2가지 모두가 이 차이에 기여했을 것이며, 이 중 MAC 사용이 더 크게 작용한 것으로 보인다. 감쇠보정방법이 다른 PET 영상들사이의 섭취값을 비교할 때는 이러한 차이를 고려해야 할 것이다.

관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교 (Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease)

  • 공은정;조인호;천경아;원규장;이형우;박종선;신동구;김영조;심봉섭
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권5호
    • /
    • pp.354-361
    • /
    • 2008
  • 목적: 암모니아의 심근섭취는 심근의 관류나 생존능 및 대사에 관계되어 있으며, N-13 암모니아 PET은 심근의 허혈을 진단하는 데에 유용한 것으로 알려져 있다. 그러나, 아데노신을 이용한 약물부하 심근관류 검사로 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT 검사를 비교한 연구는 없었다. 이 연구에서는 관상동맥질환이 의심되는 환자에게서 아데노신 약물부하로 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT를 시행하여 두 검사의 차이를 비교분석하여 N-13 암모니아 PET/CT의 임상 유용성을 알아보았다. 대상 및 방법: 관상동맥질환이 의심되는 환자 중 Tc-99m 세스타미비 SPECT와 N-13 암모니아 PET/CT를 동시에 시행할 수 있었고, 검사 1주일 이내 관상동맥조영술을 시행하였던 17명의 환자(남자:13명, 평균연령 $63{\pm}11$세)를 대상으로 하였다. 아데노신약물 부하 후 N-13 암모니아 PET/CT와 Tc-99m 세스타미비를 검사하여 육안 분석과 정량분석을 실시하였다. 결과: 관상동맥조영술에서 50% 이상의 협착이 확인된 관상동맥의 진단에 대한 민감도와 특이도는 N-13 암모니아 PET/CT는 91%와 89%로, Tc-99m세스타미비 SPECT는 65%와 82%로 각각 나타났다. 또한 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT는 전체에 238분절 중 65%인 154분절에서 동일한 결과를 보였으며, N-13 암모니아 PET/CT는 Tc-99m 세스타미비 SPECT에서 비가역적인 관류결손을 보였던 병변 중 54%에 대하여 가역적인 관류결손을 나타내었다. 협착혈관이 관장하는 심근부위에 해당하는 110개의 분절에 대하여 부하기와 휴식기의 계수를 N-13 암모니아 PET/CT와 Tc-99m세스타미비 SPECT에서 각각 비교하였을 때, 부하기의 비교에서는, 두 검사간에 유의한 차이를 보이지 않았으나, 휴식기에서는 N-13 암모니아 PET/CT의 계수가 Tc-99m세스타미비 SPECT의 계수보다 높았으며 (p<0.01), 휴식기와 부하기의 계수의 차이도 N-13 암모니아 PET/CT가 Tc-99m 세스타미비 SPECT보다 큰 것으로 나타났다(p<0.01). 결론: N-13 암모니아 PET/CT는 Tc-99m 세스타미비 SPECT보다 관상동맥질환의 진단이 정확하고, 가역적인 관류결손을 보인 분절의 수가 많으며, 휴식-부하 관류차이도 현저하여, 관상동맥질환의 정확한 진단과 함께 심근의 허혈이나 생존능을 더욱 잘 반영하는 것으로 사료된다.