• Title/Summary/Keyword: Quantification II analysis

Search Result 67, Processing Time 0.03 seconds

Development of Landslide Hazard Map Using Environmental Information System: Case on the Gyeongsangbuk-do Province (환경정보시스템을 이용한 산사태 발생위험 예측도 작성: 경상북도를 중심으로)

  • Bae, Min-Ki;Jung, Kyu-Won;Park, Sang-Jun
    • Journal of Environmental Science International
    • /
    • v.18 no.11
    • /
    • pp.1189-1197
    • /
    • 2009
  • The purpose of this research was develop tailored landslide hazard assessment table (LHAT) in Gyeongsangbuk-do Province and propose building strategies on environmental information system to estimate landslide hazard area according to LHAT. To accomplish this purpose, this research investigated factors occurring landslide at 172 landslide occurred sites in 23 city and county of Gyeongsangbuk-do Province and analyzed what factors effected landslide occurrence quantity using the multiple statistics of quantification method(I). The results of analysis, factors affecting landslide occurrence quantity were shown in order of slope position, slope length, bedrock, aspect, forest age, slope form and slope. And results of the development of LHAT for predict mapping of landslide-susceptible area in Gyeongsangbuk-do Province, total score range was divided that 107 under is stable area(IV class), 107~176 is area with little susceptibility to landslide(III class), 177~246 is area with moderate susceptibility to landslide(II class), above 247 area with severe susceptibility to landslide(I class). According to LHAT, this research built landslide attribute database and made 7 digital theme maps at mountainous area located in Goryeong Gun, Seongju-Gun, and Kimcheon-City. The results of prediction on degree of landslide hazard using environmental information system, area with little susceptibility to landslide(III class) occupied 65.56% and severe susceptibility to landslide(I class) occupied 0.51%.

Keratanase II Digestion Accompanied with a Liquid Chromatography/Tandem Mass Spectrometry for Urinary Keratan Sulfate Quantitative Analysis

  • Chuang, Chih-Kuang;Lin, Hsiang-Yu;Wang, Tuen-Jen;Huang, Sung-Fa;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.3 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: Mucopolysaccharidosis IV (MPS IV) is a disease characterized by deficient activity of N-acetylgalactosamine-6-sulfatase (GALNS) causing excessive lysosomal storage of keratan sulfate (KS). The identification of the relevant disaccharide units of KS after keratanase II digestion followed by liquid chromatography/tandem mass spectrometry detection (LC-MS/MS) is validated and applicable for the preliminary diagnosis of MPS IV. Methods: A total of 67 urine samples were collected and analyzed from 11 MPS IV patients comprising 10 MPS IVA and one MPS IVB patients, and 56 normal controls. Urinary glycosaminoglycan was first precipitated by the Alcian blue method followed by a digestion of keratanase II. The protonated species of the digested disaccharide products were detected by using multiple reaction monitoring experiment. Results: One particular disaccharide of KS was selected. The transition mass-to-charge (m/z) of the parent ion and its daughter ion after collision was $462.0{\rightarrow}97.0$, whereas the chondrosine used as an internal standard in this assay was m/z $353.9{\rightarrow}73.0$. The results corresponded well with the two-dimensional electrophoresis method. The quantities of urinary KS were significantly raised in confirmed MPS IV patients when comparing with those of normal controls ($170.2{\pm}81.1$ vs. $4.06{\pm}1.92{\mu}g/mL$). Conclusion: The LC-MS/MS method for MPS IVA determination is specific, sensitive, validated, and applicable for urinary KS quantification. This method can be used not only as a first-line biochemistry examination of MPS IVA, but also as an outcome survey after enzyme replacement therapy.

Rapid Determination of Caffeine in Forensic Aqueous Sample by Dilute and Shoot LC-MS/MS (시료 희석 직접 주입 LC-MS/MS를 이용한 법화학 수용액 시료 중 카페인 신속 분석)

  • Choi, Yun Jeong;Kim, Hee Seung;In, Moon Kyo;Kim, Jin Young
    • YAKHAK HOEJI
    • /
    • v.60 no.3
    • /
    • pp.112-117
    • /
    • 2016
  • A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of caffeine in forensic aqueous sample. The centrifuged sample ($100{\mu}l$) was diluted 50-fold with distilled water. The diluted sample ($400{\mu}l$) was then diluted further with $200{\mu}l$ of 0.1% formic acid solution and $400{\mu}l$ of acetonitrile containing 500 ng of caffeine-(3-methyl-$^{13}C_3$) prior to LC-MS/MS analysis. The mobile phase was composed of 0.1% formic acid in distilled water (A) and acetonitrile (B). Chromatographic separation was performed by using a Zorbax SB-C18 ($100mm{\times}2.1mm$ i.d., $3.5{\mu}m$) column and caffeine was eluted within 1.1 min. Linear least-squares regression with a 1/x weighting factor was used to generate a calibration curve with the coefficients of determination ($r^2=0.9983$). The lower limit of quantification was $25ng/ml$ for the analyte. The process efficiency was 98.6~100.1%. Intra- and inter-day precisions were not more than 2.1% and 1.7%, while intra- and inter-day accuracies were ranged from -6.8 to 4.5%, respectively. The suitability of the method was examined by analyzing unknown forensic aqueous samples.

Quantitative Analysis of Eleven Bioactive Constituents of a Traditional Herbal Medicine, Yeonggyechulgam-tang using, Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • v.23 no.2
    • /
    • pp.84-91
    • /
    • 2017
  • This study proposes a sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry method of efficiently assessing the quality of a traditional herbal medicine called Yeonggyechulgam-tang (YGCGT). The following compounds 1 - 11, namely, liquiritin apioside (1), liquiritin (2), liquiritigene (3), coumarin (4), cinnamic acid (5), cinnamaldehyde (6), glycyrrhizin (7), atractylenolide III (8), atractylenolide II (9), atractylenolide I (10), and pachymic acid (11) were separated on a UPLC BEH $C_{18}$ column ($2.1{\times}100mm$, $1.7{\mu}m$) at a column temperature of $45^{\circ}C$ eluted with a gradient condition of 0.1% (v/v) formic acid in distilled water and acetonitrile. The correlation coefficient of the calibration curve of the eleven constituents was ${\geq}0.9936$. The limits of detection and quantification of the compounds 1 - 11 were 0.06 - 4.73 ng/mL and 0.17-14.20 ng/mL, respectively. Using this analytical method, the compound 11 in lyophilized YGCGT decoction extract was not detected, while the compounds 1 - 10 were detected 0.13-166.43 mg/g.

Quantitative Analysis of Hyangsayukgunja-Tang Using an Ultra-Performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 향사육군자탕의 주요성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.46 no.4
    • /
    • pp.352-364
    • /
    • 2015
  • The aim of this study was to quantitatively analyze for quality assessment of eighteen marker compounds, including homogentisic acid, 3,4-dihydroxybenzaldehyde, spinosin, liquiritin, hesperidin, ginsenoside Rg1, liquiritigenin, ginsenoside Rb1, glycyrrhizin, 6-gingerol, atractylenolide III, honokiol, costunolide, dehydrocostuslactone, atractylenolide II, nootkatone, magnolol, and atractylenolide I, in Hyangsayukgunja-tang using an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer. The column for separation of eighteen marker components were used a UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}$) and kept at $45^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as mobile phase. The flow rate and injection volume were 0.3 mL/min and $2.0{\mu}l$, respectively. The correlation coefficient of all marker compounds was ${\geq}0.9914$, which means good linearity, within the test ranges. The limits of detection and quantification values of the all analytes were in the ranges 0.04-1.11 and 0.13-3.33 ng/mL, respectively. As a result, five compounds, homogentisic acid, 3,4-dihydroxybenzaldehyde, spinosin, liquiritigenin, and atractylenolide I, in this sample were not detected and the amounts of the 13 compounds except for the 5 compounds were $8.10-6736.37{\mu}g/g$ in Hyangsayukgunja-tang extract.

A Study on the Trace Analysis of Germanium in Inorganic Matrices by Differential Pulse Polarography (Differential Pulse Polarography에 의한 무기물 시료 중 Germanium의 미량 분석에 관한 연구)

  • Shin, Ho-Sang;Oh, Yun-Suk;Shin, Hak-Soo
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.253-261
    • /
    • 1996
  • Analytical method for the determination of trace germanium in inorganic matrices by differential pulse polarography(DPP) was studied. The reduction peak of germanium(IV) in perchloric acid solution containing 1, 2, 3-trihydroxy benzene appeared at -0.45V(vs. Ag/AgCl) and the peak current for germanium complex varied linearly with concentration variation. Factors affecting sensitivity and precision for germanium quantification were studied and detection limit under the investigated parameters was 1ng/ml. Inorganic samples were decomposed by fusion with potassium pyrosulfate. Serious interferences of Se(IV), Pb(II), As(III) for the determination of germanium were discussed. Interferences of these elements could be avoided by extraction of germanium from decomposed matrices by $CCl_4$ in 10M HCl solution. The germanium contents of inorganic samples(Pb bf. dust, Cu bf. dust, gneiss, Cu anode slime) were determined by the above method.

  • PDF

Analysis of antibiotic residues in milk from healthy dairy cows treated with bovine mastitis ointment using ultra-performance liquid chromatography coupled with electrospray tandem mass spectrometry

  • Park, Eun-Kee;Ryu, Yong-Jae;Cha, Chun-Nam;Yoo, Chang-Yeul;Kim, Suk;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.4
    • /
    • pp.233-239
    • /
    • 2016
  • This study was conducted to analyze penicillin G (PEG), streptomycin (STR) and neomycin (NEO) residues in milk of healthy lactating cows. Milk samples were collected from all four quarters of 12 dairy cows 2−7 days after intramammary infusions of an ointment containing PEG, STR and NEO once (n = 4; group I) or twice (n = 4, group II) daily. Ultra-performance liquid chromatography coupled with electrospray tandem mass spectrometry was used to determine the antibiotic residues in the samples. The correlation coefficient ($r^2$) of the calibration curves for all antibiotics was > 0.999 and the limits of detection and quantification were $0.002-0.005{\mu}g/mL$ and $0.007-0.02{\mu}g/mL$, respectively. Recovery rates were ranged from 75.5 to 92.3%. In group I, PEG, STR and NEO residues were detected in milk at 2, 3 and 2 days post-treatment, respectively, which were below the maximum residue limit (MRL). In group II, PEG, STR and NEO residues were detected in milk at 2, 3 and 3 days post-treatment, respectively, which were bellow the MRL. These results suggest that a 3-day for milk withdrawal period after the ointment treatment might be sufficient for reduction of the antibiotic residues below the MRL.

Study on the histomorphometry of guided bone regeneration using automated image analysis system (자동 영상분석 계기를 이용한 골 유도재생능력의 분석에 관한 조직계측학적 연구)

  • Kim, T.I.;Ku, Y.;Rhyu, I.C.;Chung, C.P.;Han, S.B.;Choi, S.M.;Son, S.H.
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.771-778
    • /
    • 1996
  • The assessment of alveolar bone changes on dental radiographs to indicate progression of periodontal diseases or healing response to therapy is routine procedure. However, the diagnostic accuracy in detecting small alveolar bone changes is very limited. Recently, guided bone regeneration therapy is popular, but the quantification of new bone is somewhat difficult with conventional evaluation method. To quantificate the amount of new bone, various evaluating methods have been introduced including histomorphometry, radiomorphometry, biochemical analysis, X-ray probe microanalysis, scanning electron microscope backscatter method. In this study, guided bone regeneration using resorbable membrane with & without PDGF-BB is quatificated through histomorphmetry to evaluate the efficacy of histomorphometric analysis. 4 beagle dogs and 8 Sprague-Dawley rats were selected as experimental animals. In beagle dog experiment, $4{\times}4mm$ Class II defects were created in maxillary both second premolars, and biodegradable membrane containing PDGF-BB(experimental group) were covered over one defect, and same membrane without PDGF-BB(control group) were covered over the other defect. At 2 weeks, 5 weeks after surgery, each beagle dogs were sacrificed, and the tissues were treated by undecalcified fixation. In Sprague-Dawley rat experiment, 5mm round defect were created in temporal bone, the same membranes were covered on the defects. At 1 week, 2 weeks after surgery, each rats were sacrificed, and undecalcified fixation were taken. After grinding tissue specimen, we analyse them histomorphometrically using image analysis system. In beagle dog 2 weeks specimens, new bone formation area were $0.03123mm^2$ in experimental group,and $0.03012mm^2$ in control group. At 5 weeks specimens, $0.15324mm^2$ in experimental group, and $0.09123mm^2$ in control group. In Sprague-Dawley rat specimens, new bone fomation area were $0.20448mm^2$ in 1 week experimental group, $0.03604mm^2$ in 1 week control group. At 2 weeks specimens, $0.46349mm^2$ in experimental group, $0.17741mm^2$ in control group. The results indicated that histomorphometric analysis of new bone formation using image analysis system is very effective quantification method to evaluate the efficacy of treatment modalities.

  • PDF

Study of Disclusion Time during Mandibular Eccentric Movement in Myofascial Pain Syndrome Patients by T-Scan II, Computerized Occlusal Analysis System (컴퓨터 교학분석기인 T-Scan II를 이용한 측방운동시 구치부 이개시간에 관한 연구)

  • Shin, Jun-Han;Kwon, Jeong-Seung;Kim, Seong-Taek;Park, Hyung-Uk;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.187-197
    • /
    • 2011
  • Temporomandibular disorders(TMD) is a collective term which is embracing a number of clinical problems that involve the masticatory musculature, the TMJ and associated structures, or both. Myofascial pain, which is a kind of masticatory muscle disorder of TMD, is the sensory, motor, and autonomic symptoms caused by myofascial trigger points. There has been some controversies regarding etiologies of TMD and MFP. Especially the issue of occlusal conditions has been a critical issue for long time. Despite much efforts, the results of studies regarding occlusal conditions were contradictory. These controversies might be mostly due to various factors resulting from the complex nature of TMD, however, inaccurate and inappropriate study design, selection criteria, methodologies also play significant roles. Recently, a computerized occlusal analysis system, T-Scan II which made it possible to reveal quantifiable time data and relative force data for analyzing occlusion, was introduced. Some authorities suggested that the concept of disclusion time and prolonged disclusion time of posterior tooth and MFP are related using T-Scan II. But the previous studies which used T-SCAN II are not reliable for they did not provide accurate diagnostic criteria of MFP. Morever they did not compare with controls, and had many other problems. The purpose of this study was to evaluate the relationship between MFP and prolonged disclusion time of posterior tooth, which is one of the occlusal factors of TMD, by selecting 30 subjects as the study group through strict criteria and comparing them with 38 controls using T-SCAN II, computerized occlusal analysis system. The results, statistically analyzed, are summarized as follows: 1. Cronbach ${\alpha}$ coefficient of repeated measurements of disclusion time was 0.92. 2. There were no statistically significant differences at repeated measured disclusion time of both side between control and study group. 3. There was no statistically significant diffefence in the disclusion time between right and left side. From the results above, we can suggest that there was no relationship between MFP and disclusion time, so irreversible treatments leading to the reduction of disclusion time for treating MFP would not be appropriate. However more controlled, large scaled study, which consider various occlusal factors, and quantification of symptoms using Helkimo index would be necessary in the future.

A Study on Subjective Noise Evaluation of School Area on Aircraft Noise near Airport (공항주변학교의 항공기 소음의 피해의식에 관한 연구)

  • Kim, Gap-Su;Hwang, Jeong-Hun;Bae, Eun-Hye
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.3
    • /
    • pp.51-57
    • /
    • 2010
  • In this study, damages due to the aircraft noise were examined in more than 190 elementary, middle and high schools near the airports in Korea, and the persecutory idea forecast model was established using the quantification theory type II. Via the survey of 1,012 teachers in the schools, a class interference forecast model was established, and the noise characteristics of five areas, four military/civil common-use airports and one shooting range, were examined. The following conclusions were made from the study. WECPNL values in the five military/civil common-use airports showed that all of them were Class 1 or 2 affected areas, which indicated that they had serious aircraft noise problems to be addressed. The most influential factor in the aircraft noise persecutory idea model was the distance between the airport and the school. It showed a positive relationship at a distance of less than 5 km, and a negative relationship at a distance of 10 km or more. The number and time of aircraft noise exposure as well as the types of airports and window structures had strong influences. The forecast model had a correlation ratio of 0.56, which indicates that it is highly appropriate. In the class interference factor analysis, the time and number of aircraft noise exposure were strong influential factors, and the results varied according to the service duration and sex of teachers. This model had a correlation ratio of 0.61, which indicates it is highly appropriate.