• Title/Summary/Keyword: Quality time

Search Result 15,751, Processing Time 0.051 seconds

Precision evaluation of the treatment that used coordinates confirmation of couch in case of two forgets adjoined. (Couch의 좌표 확인을 이용한 치료 위치 이동의 정확성 평가)

  • Seo Jeong-min;Jeong Cheon-young;Park Young-hwan;Song Ki-won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.35-40
    • /
    • 2003
  • I. Purpose Confirming an error to be able to break out in a method to move couch manually while operator sees the skin marks on patient in case of curing head who got 2 targets adjoined, so we analyze coordinates price of couch, evaluate reproducibility and precision of change movements between targets. II. Materials and Methods In radiotherapy, for confirming errors in manual movements by operators by exchanging between two targets to treat patient head, we read coordinates price(vertical, longitudinal, lateral three directions of couch) shown on a monitor of LINAC( CL 2100, Varian, USA) in order to evaluate accuracy about the length that moved in time for moving couch manually. After reading movement length of coordinates recorded in three directions of all treatment, we compared distance between targets recorded in RTP(Pinnacle, ADAC, USA) with reading coordinates price of couch, setting actually done the same patient for ten times, coordinates were recorded, treated for evaluating averages and degrees of errors and standard deviations. III. Results In method to confirm skin marks of patient by operators' view and to move couch manually, average standard deviations of movements between two targets are vertical 1.4mm, longitudinal 0.9mm, lateral 2.2mm in each direction. As for the error in straight dimension, it is about 3.6mm averages and 5.1mm maximum. The average of errors in each directions was vertical 1mm, longitudinal 0.7mm, lateral 2.7mm. The greatest error broke out in lateral direction with $25\%$ of all cases ; to exceed an error average. IV. Conclusions If operators moved manually couch for changing target points, errors about 3.6mm average degrees occur. It is important that operators confirm the errors prices of actual couch coordinates for asking a correct movement between the targets adjoined each other ; in case of treatment demanding high precision like 3D conformal therapy or IMRT. Therefore, if we apply couch coordinates confirmation to reproducibility and to precision evaluation of treatment, it's expected that we can execute high-quality radiotherapy.

  • PDF

A Study on the Applicability of Soilremediation Technology for Contaminated Sediment in Agro-livestock Reservoir (농축산저수지 오염퇴적토의 토양정화기술에 대한 적용성 연구)

  • Jung, Jaeyun;Chang, Yoonyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.3
    • /
    • pp.157-181
    • /
    • 2020
  • Sediments from rivers, lakes and marine ports serve as end points for pollutants discharged into the water, and at the same time serve as sources of pollutants that are continuously released into the water. Until now, the contaminated sediments have been landfilled or dumped at sea. Landfilling, however, was expensive and dumping at sea was completely banned due to the London Convention. Therefore, this study applied contaminated sedimentation soil of 'Royal Palace Livestock Complex' as soil purification method. Soil remediation methods were applied to pretreatment, composting, soil washing, electrokinetics, and thermal desorption by selecting overseas application cases and domestically applicable application technologies. As a result of surveying the site for pollutant characteristics, Disolved Oxigen (DO), Suspended Solid (SS), Chemical Oxygen Demand (COD), Total Nitrogen (TN), and Total Phosphorus (TP) exceeded the discharged water quality standard, and especially SS, COD, TN, and TP exceeded the standard several tens to several hundred times. Soil showed high concentrations of copper and zinc, which promote the growth of pig feed, and cadmium exceeded 1 standard of Soil Environment Conservation Act. In the pretreatment technology, hydrocyclone was used for particle size separation, and the fine soil was separated by more than 80%. Composting was performed on organic and Total Petroleum Hydrocarbon (TPH) contaminated soils. TPH was treated within the standard of concern, and E. coli was analyzed to be high in organic matter, and the fertilizer specification was satisfied by applying the optimum composting conditions at 70℃, but the organic matter content was lower than the fertilizer specification. As a result of continuous washing test, Cd has 5 levels of residual material in fine soil. Cu and Zn were mostly composed of ion exchange properties (stage 1), carbonates (stage 2), and iron / manganese oxides (stage 3), which facilitate easy separation of contamination. As a result of applying acid dissolution and multi-stage washing step by step, hydrochloric acid, 1.0M, 1: 3, 200rpm, 60min was analyzed as the optimal washing factor. Most of the contaminated sediments were found to satisfy the Soil Environmental Conservation Act's standards. Therefore, as a result of the applicability test of this study, soil with high heavy metal contamination was used as aggregate by applying soil cleaning after pre-treatment. It was possible to verify that it was efficient to use organic and oil-contaminated soil as compost Maturity after exterminating contaminants and E. coli by applying composting.

Radiotherapy of Metastatic Neck Nodes from an Unknown Primary Site (근원 불명 전이성 경부암의 방사선치료)

  • Park, In-Kyu;Yun, Sang-Mo;Kim, Jae-Cheol
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 1997
  • group($22\%\;vs.\;38\%$, p=0.24). The 5YSRs of 21 patients of primary tumor extension to adjacent sites and the other 13 patients of tonsillar proper site were $28\%\;and\;38\%$, respectively but the difference was not significant statistically(p=0.52) There was a statistically significant difference in 5YSRs between the groups of the Patients who received radiotherapy in less than 61days vs more than 60days($60\%\;vs.\;18\%$, p=0.027). All living Patients without any tumor progression(n=11) had suffered from serious late sequelae such as xerostomia, edentia, dental caries and one patient had the osteoradionecrosis of mandible. On univariate analysis. the duration of radiotherapy and T-stage were the significant prognostic factors affecting 5YSR. On multivariate analysis, also the duration of radiotherapy was the only significant Prognostic factor(p=0.01). Conclusion : There was no survival difference between the radiotherapy alone and with neoadiuvant chemothe groups. Although it was a retrospective study, the role of conventional radiotherapy alone could be effective as the local treatment modality only for the early stage of tonsillar carcinomas. But for the purpose of more improved survivals and better quality of lives of living patients, other altered fractionation such as hyperfractionated radiotherapy with shorter treatment time and smaller fraction size rather than conventional radiotherapy might be beneficial and these prospective studies are needed.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number (3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가)

  • Kim, Dong-Seok;Kim, Seong-Hwan;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this.

  • PDF

Comparison of Blood Glucose Level in Pancreatic Cancer on $^{18}F$-FDG PET (췌장암 환자의 양전자방출단층촬영(PET) 검사 시 혈당치와 영상에 관한 분석)

  • Oh, Shin-Hyun;Lee, Seung-Jae;Park, Hoon-Hee;Park, Yong-Sung;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.65-69
    • /
    • 2011
  • Purpose: Normal pancreas has low uptake rate in $^{18}F$-FDG PET scan. However, it is possible to diagnose malignancy of pancreatic cancer which has high uptake rate. Many studies approve a high prevalence of diabetes in pancreatic cancer and if the blood glucose level (BGL) is over the normal range, FDG uptake will be decreased and there will be inconvenience for patients from the delay time to reduce the high BGL or could cause difficulty to arrange the schedule. Therefore, we studied the relation of BGL and image quality in pancreatic cancer on PET. Materials and Methods: A hundred patients had PET scan. The prevalence of pancreatic cancer and diabetes were evaluated using SPSS ver. 17. The fasting BGL of patients were examined and sorted as diabetes mellitus (DM) group and Non-DM group. For the evaluation, patients were divided into 3 groups (Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L). The ROI was drown on Liver and Lung for the PET imaging analysis. Results: Fifty three male and forty seven female were in the patients. The average age was $60.1{\pm}13.5$. There were 36 patients (male: 22, female: 14, 36%) who had pancreatic cancer with DM. There were 15 patients who showed over 7.0 mmol/L in their fasting BGL and 85 patients who showed under 7.0 mmol/L in their fasting BGL. Among the Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L, there was not a statistical significance (p>0.05). Conclusion: The prevalence of pancreatic cancer was comparatively high in this study. If the fasting BGL was slightly over the normal BGL, we believe it will not give a severe disturbance when the patients have PET scan. Furthermore, the examination schedule doesn't need to change and the inconvenience from the delay of patients preparation will be reduced.

  • PDF

A Study on the Realities of Custom-made Clothing Production in Middle-aged Women's Clothing Firms (중년여성복업체(中年女性服業體)의 맞춤복(服) 생산실태(生産實態) 연구(硏究))

  • Park, Yu-Jeong;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.6 no.2
    • /
    • pp.1-16
    • /
    • 2002
  • The need for ready-to-wear clothing increases as the problem comes to arise from the fit of custommade clothing due to the characteristics of middle-aged women's somatotype. At this point of time, a study on the realities of production of custom-made clothing in middle-aged women's clothing business firms is of very greatly significance. Therefore, this study was intended to identify the problem and improvements through the survey research of production of custom-made clothing in middle-aged women's clothing business firms and further present the plan for development of custom-made clothing business. The questionnaire was framed based on the contents extracted from the preliminary questionnaire research for the pattern section chief of each business firm. Collected data were statistically processed using the SPSS 10.0 Windows program. As a result, the following findings were obtained: 1. The target age of the middle-aged women's clothing business firms ranged from more than 45 years to less than 50 years of age. Clothing business firms much made inroads into the ready-to-wear clothing market largely in the 1980s and the 1990s. Their active entry into the custom-made clothing market occurred in the 1970s and the 1980s. 2. In terms of the clothing production method of middle-aged women's clothing firms, some private boutique and designer brand clothing firms entered the clothing market with a focus on custom-made clothing in the beginning of its organization and introduced the production method of ready-to-wear clothing in accordance with changes in production methods and consumers' needs and wants. National brand clothing firms manufactured clothing with a focus on ready-to-wear clothing from the beginning of its organization, but at last they manufactured both partial custom-made and whole custom-made as the problem arose from ready-to-wear clothing. Seeing that their clothing production showed the ratio readyto-wear to custom-made clothing of 2.58:1. And it was found that the manufacture of ready-to-wear and custom-made clothing took into consideration the great difference in the pattern, size and design plan. The research of the clothing production process showed that whole custom-made and partial custommade were distinguished according to whether or not the sample was presented. 3. The ready-to-wear pattern of middle-aged women's clothing firms were used with a focus on the 'patternmaker-developed pattern' and company-developed pattern'. Most clothing businesses produced clothing in 4 to 5 basic sizes, which is found to be insufficient to complement the physical characteristics of middle-aged women with many specific somatotypes. In the pattern of custom-made clothing, the 'pattern of ready-to-wear were applied' or the 'customized pattern was developed'. Actual measurements were most used as the size of custom-made, and accordingly it is predicted that the level of satisfaction is higher with the fit of custom-made clothing than that of ready-to-wear. The selling place and the head office showed the similar percent as the place for measuring the size of custom-made clothing. Size measurers were mostly the shop master. And it was found that most clothing business firms had a problem when the measured size was applied to the pattern. Accordingly, it is necessary to provide education on size measurement for shop masters. 4. It was found that in the middle-aged women's clothing firms, the pattern correction of the length of sleeve, jacket and slacks occupied the highest percent. Accordingly, it is necessary to provide for the size system to complement the accurate somatotype characteristics of middle-aged women. 5. In custom-made clothing customer management, most firms engaged in customer somatotype management through size management. They provided customers with commodity information by informing them of the sales and event period and practiced human management for customers by maintaining the get-together and friendly relationship. 6. Middle-aged women's clothing businesses responded that it would be necessary to improve the fit of custom-made clothing and complement their pursuit for individuality as the plan to improve its quality. In consequence, it suggests that middle-aged women's clothing businesses should provide middle-aged women with the clothing of better-suited size and refined design. Middle-aged women's clothing businesses responded that it was the most urgent task to form the custom-made clothing manufacturing team as the plan to expand the custom-made clothing market, which is identified as their emphasis on the systematized production of custom-made clothing.

Experiences and Meaning of AP (Advanced Placement) at the Specialized Schools for the Highly Gifted: Through the In-depth Interview with the AP Participants (과학영재학교에서의 AP(Advanced Placement)의 경험과 의미: 대학생이 된 영재학교 졸업생들과의 심층인터뷰를 중심으로)

  • Han, Ki-Soon;Choe, Ho Seong
    • Journal of Gifted/Talented Education
    • /
    • v.24 no.6
    • /
    • pp.1001-1024
    • /
    • 2014
  • The purpose of the study is to explore the experiences and meaning of the AP (Advanced Placement) at the specialized school for the highly gifted through the in-depth interview with 39 college students who had graduated from the specialized schools with the AP experiences. It is expected that the AP will be expanded to the students at the Science High Schools from the year of 2015, however, there has been no study to examine the realities of the AP in-depth especially through the voices of the AP participants. Students have taken 8 required and/or selective courses as AP in average. Students usually start to take AP from the second year of the specialized school for the highly gifted, but some start from the first year through the placement test. Numbers of available AP courses vary by subjects, but relatively more courses open in the areas of math and physics. Students' opinions regarding the AP were quite positive. Specifically, the high quality of the AP class and energetic interaction between student and teacher compared to the college classes were preferred by the students. However, it was controversial whether C+ is enough for the pass condition of the AP. Students were using the shortened time by AP in diverse ways, such as early graduation, double majors, exchange students, individual researches, and so on. Most of all, they tried to search for their career interests through the AP experiences. In closing, the present study provides some advices and future directions for the better AP management, including the improvement of administrative system between schools for the gifted and the universities, and the expansion of the number of university which approves the AP system.

Quality Changes in Oyster Mushrooms during Modified Atmosphere Storage as Affected by Temperatures and Packaging Materials (저장 온도와 포장재에 따른 느타리버섯의 MA 저장 중 품질변화)

  • Choi, Mi-Hee;Kim, Gun-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1079-1085
    • /
    • 2003
  • Modified atmosphere packaging was applied to oyster mushrooms (Pleurotus ostreatus) to study the effect of storage temperatures and packaging materialso. Whole mushrooms (200g) were package with polyethylene film $(PE,\;60{\mu}m\;thickness)$, ethylene vinyl acetate (EVA), or ceramic film (containing 5% zeolite) and stored at 0, 5, 10 and $20^{\circ}C$. Weight loss, color, firmness, gas composition $(O_2,\;CO_2)$ inside the film package and ethanol content in the tissue of MA packaged mushrooms were examined. Mushroom that were packed unwrapped in a conventional hardboard box (2 kg) lost marketability at a very early stage of storage due to weight loss, shrinkage, browning, and spore formation. During storage, film packaging prevented or retarded the deterioration of the mushrooms in the aspects of appearance, texture, and discoloration. Firmness slightly decreased with storage time. Total color difference was much higher in the control than in the film-packaged mushroom and rapidly increased at the early of storage. Correlation analysis showed a high correlation between total color difference and b values. These results were characterized by the reduced respiration rate resulting from elevated carbon dioxide and reduced oxygen levels in the package. At all storage temperatures, ethanol content in the tissue increased slightly at the early part of storage and rose considerably towards the end of the storage period. Ethanol content in the oyster mushrooms was higher in the stipe than in pileus tissues. The shelf life of the oyster mushrooms was about $8{\sim}11$ days at $0^{\circ}C$, about $4{\sim}6$ day at $5^{\circ}C$, about $2{\sim}3$ days at $10^{\circ}C$, and about $1{\sim}2$ days at $20^{\circ}C$.

Application of Low Dose UV-C Irradiation for Shelf-Life Extension of Peach (Prunus persica L. Batsch) (복숭아 저장성 증진을 위한 저선량의 UV-C 조사 효과)

  • Lee, Kyung-Haeng;Park, Jae-Hee;Lee, Yu-Jin;Ban, Ki-Eun;Jang, Joo-Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.26 no.1
    • /
    • pp.85-91
    • /
    • 2013
  • For shelf-life improvement of the domestic peach, a treatment with low dose UV-C (0~3.0 $kJ/m^2$) irradiation was performed and the spoilage rate and changes of physico-chemical and sensory properties of the peach were investigated. Control showed spoilage at day 4, and then 50% of control showed spoilage at day 8. However, samples treated with low dose UV-C showed lower percentage of spoilage than those of control at day 8. Weight changes of control and the samples with UV-C treatment showed no difference during the storage period. There was no difference in pH of samples among the treatments but they were increased by storage time. Hardness of samples was not different among treatments at initial stage of storage after UV-C treatment. However, the hardness of control sample was decreased faster than those of the samples with low dose UV-C treatment after 6 days of storage. No significant changes in lightness, redness and yellowness of the samples by UV-C treatment were observed. The sensory parameters including taste, flavor, and color at initial and during storage period were not different among treatments except for texture and overall acceptance. The scores for texture and overall acceptance of control were decreased faster than those of UV-C treatments during storage. In general, samples treated with low dose UV-C showed higher sensory quality than control.