• Title/Summary/Keyword: Quality of movement

Search Result 885, Processing Time 0.023 seconds

An Analysis of Single PPM Quality Innovation's Status using Covariance Structure Model (공분산구조모델에 의한 싱글 PPM 품질혁신 운동 추진현황 분석)

  • Koo, Il-Seob;Kim, Tae-Sung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.4
    • /
    • pp.102-108
    • /
    • 2005
  • Single PPM Quality Innovation Movement is originally developed quality program in Korea for supplier's quality level-up since 1995. The quality target is below the 10ppm(parts per million) in outgoing quality and delivered goods plus field claim. Recently 1,053 companies is received Single PPM Quality Certification from government. This quality program is to realized the anticipated results not only duality level's increasing, but also company's confidence, competitiveness. We were able to obtain participations of 75 questionnaire, and derived statistics by means of SPSS/PC version 10.0. In this study, we find the bottleneck factor for promotion and upgrade S-PPM, and suggest a way out of difficulties.

Influences of Neck and/or Wrist Pain on Hand Grip Strength of Industrial Quality Proofing Workers

  • Wollesen, Bettina;Graf, Julia;Schumacher, Nils;Meyer, Gianluca;Wanstrath, Matthias;Feldhaus, Christian;Luedtke, Kerstin;Mattes, Klaus
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.458-465
    • /
    • 2020
  • Background: The aim of this study was to analyze the interaction between neck and/or wrist pain and hand grip strength (HGS) and to investigate factors (age, sex, neck disorders, and carpal tunnel syndrome) influencing the HGS of industrial quality proofing workers (N = 145). Methods: Standardized questionnaires [Neck Disability Index (NDI), Boston Carpal Tunnel Questionnaire] were used to evaluate existing neck and/or wrist pain. HGS measurements were performed in different wrist positions. Results: Significant differences between participants with and without neck pain were found in different wrist positions, in neutral wrist position right [without neck pain (n = 48) 46.34 (43.39 - 49.30); with neck pain (n = 97) 38.46 (36.20 - 40.72), F(1,144) = 16.82, p < 0.001, ŋp2 = 0.11] and left [without neck pain 44.06 (41.19 - 46.94); with neck pain 37.36 (35.13 - 39.58), F(1,144) = 12.70, p < 0.001, ŋp2 = 0.08]. A significant difference between participants with and without wrist pain was found for neutral wrist position right [without wrist pain (n = 105) 42.53 (40.37 - 44.70); with wrist pain (n = 40) 37.24 (33.56 - 40.91), F(1,144) = 6.41, p = 0.01, ŋp2 = 0.04]. Regression analysis showed significant results especially for steps two (age and weight, NDI) and three (age and weight, NDI, Boston Carpal Tunnel Questionnaire) for neutral position right (R2 = 0.355, R2 = 0.357, respectively). Conclusion: Neck pain has an impact on HGS but should be evaluated in consideration of age and sex.

Coupling Framework of Hair with FLIP Solver for Representing Spray Motion of Liquid in Wet Hair (젖은 헤어에서 분사된 액체의 움직임을 표현하기 위한 FLIP 해법과 헤어의 결합 프레임워크)

  • Kim, Jong-Hyun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.25 no.4
    • /
    • pp.1-8
    • /
    • 2019
  • In this paper, we propose a new framework that can express the detailed movement of liquid sprayed from wet hair or fur. In wet hair, not only the friction and adhesion of the hair but also the movement of the liquid has a distinctive motion compared to the dry hair. However, the recently proposed techniques only considered the contact force and friction of the hair and did not improve the movement of the liquid dispersed in the wet hair. This problem is detrimental to the quality of the result because it does not capture the detailed features expressed in the interaction of hair and liquid. The main point of this paper is to alleviate this problem and improve the quality of the result. As a result, we propose a combining framework that can efficiently express FLIP (Fluid-implicit particle) based fluid simulation and interaction of hair particles. The proposed method expresses the movement of the liquid sprayed in a curved shape which was not expressed in previous studies.

Iguana motion synthesis using soft body simulation (연체 시뮬레이션 기반 이구아나 동작 생성)

  • Moon, Jaeseok;Kwon, Taesoo
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.1
    • /
    • pp.33-38
    • /
    • 2017
  • In this paper, we suggest a method to simulate high-quality iguana animation by using low-quality motion capture data. Iguana motion data captured using a small number of markers cannot express its movement precisely, and even with a realistic skin mesh, it shows unnatural movement because of limited degrees of freedom. In order to solve this problem, we propose to simulate a natural and flexible movement by applying a soft-body simulation technique which models the movement of an iguana according to muscle forces and body's elastic forces. We construct a motion graph from the motion capture data to describe the iguana's various movements, and utilize it to select appropriate movements when the iguana moves. A target point on a terrain is set from the user's input, and a graph path is planned based on it. As a result, the input movement of iguana walking on a flat ground transforms to a movement that is adapted in an online manner to the irregular heights of the terrain. Such a movement is used to calculate the ideal muscle lengths that are needed for soft-body simulation. Lastly, a tetrahedral mesh of the iguana is physically simulated to adapt to various situations by applying a soft-body simulation technique.

Consumer Movements, Consumer Policies, and Firms' Policies for Consumer Satisfaction in Japan (일본의 소비자운동, 소비자정책, 소비자지향적 경영에 관한 소고)

  • 허경옥
    • Journal of the Korean Home Economics Association
    • /
    • v.36 no.3
    • /
    • pp.173-190
    • /
    • 1998
  • This study reviewed both consumer movement and consumer policy of government in Japan. Their evolution since the Second World War will be reviewed and compared multiple periods, after the Second World war till the late 1960s, the period of the 1970s, the period after 1980s. In addition, firms' consumer satisfaction policies were briefly reviewed in order to fully understand consumer protection activities in japan. This study found four major characteristics of consumer protection activities led by both voluntary consumer organizations and government. First, consumer protection policy of government in Japan after the late 1960s was more active than that of consumer movement by consumer organizations. Second, major concerns for consumer protection were variant over time. The major goal in the first stage of period(during the 1960s) was to protect consumer safety from defective and dangerous goods and services, whereas the goal after the late 1970s was extended to cover various areas concerning the quality of life. Those areas refer to the quality of services, the way of sales and marketing, pollution of environment, and the quality of consuming life. Third, this study found that computer networks, aiming at collecting and analyzing the very useful to improve the consuming life of Japanese by providing sufficient consumer information to encourge rational choices of consumers. Forth, a close cooperation between the central and local administrations was crucial for the successful outcome In Japan This paper gives us useful guideline regarding how to improve consumer movement and govemments' policies for protecting consumer in Korea. In addition, other lessons on successful consumer satisfaction policies of Japanese firms may enable Korean firms to shape effective consumer policies of enhancing their competitiveness.

  • PDF

Usefulness of Electrophysiological Tests in Movement Disorders (이상운동 질환에서의 신경생리적 검사법의 유용성)

  • Seo, Man-Wook;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.2
    • /
    • pp.126-146
    • /
    • 1999
  • In clinical neurology various different electrophysiological tests are widely used to demonstrate the unsuspected malfunctioning in the nervous system and to monitor over time the clinical status of patients. In addition clinical neurologists and neurosurgeons take advantage of the intraoperative monitorings to increase the quality of neurosurgical operations in the posterior fossa, in the spinal cord, or in visual pathways. In the field of movement disorders, elecrophysiolgical tests provide neurologists with making accurate differential diagnoses with useful therapeutic stratergies as well as with investigating the pathophysiological machanisms. By using the electromyographic tests it could be possible for us to evaluate the types of blephalospasm, the extent of hemifacial spasm, the level of myoclonus, and the prime muscles of torticollis etc. Sometimes the myographic guidance may be critical for choosing the exact injecting site of botulinum toxin. These several decades various electroencephalographic and evoked potential tests has been utilized in the electrophysiological laboratories to understand the basic pathophysiology of myoclonus, spasticity and other central motor dysfunctions. It could be one of the breakthroughs in the area of behavorial neurology that the brain function can be mapped by the spontaneous or evoked electrical activities of nervous system since the movement related potentials (MRPs) had been studies for several decades. Various reflex tests such as masseter reflex, blink reflex, click evoked vestibulocollic reflex, facial reflex, stretch reflex, flexor reflex, H-reflex, H-reflex recovery curve, vestibular inhibition of H-reflex, reciprocal inhibition, recurrent or Renshaw reflex, Ib inhibition, cutaneous reflex have been also used to understand normal or abnormal physiology in movement disorders. Polysomnography, posturography and gait studies are also applied in clinical neurology in association with with movement disorders which are useful in deciding the treatment regimen.

  • PDF

The Effects of Modified Constraint-Induced Movement Therapy and Bilateral Arm Training on the Upper Extremity Performance of Individuals with Chronic Hemiparetic Stroke (수정된 강제-유도운동치료와 양측성 상지훈련이 만성 뇌졸중 환자의 상지 수행 능력에 미치는 영향)

  • Yang, Sung-Hwa;Lee, Wan-Hee;Lee, Kyoung-Suk
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.5
    • /
    • pp.65-72
    • /
    • 2011
  • Purpose: The intention of this study was to investigate the effects of modified constraint-induced movement therapy (mCIMT) with bilateral arm training (BAT) on the motor performance and daily activity performance of individuals with chronic hemiparetic stroke. Methods: Sixteen subjects one year after stroke participated in this study with a control group; the pretest-posttest method was used. The subjects were randomly allocated into two groups: combination of bilateral arm training and modified constraint-induced movement therapy (n=8), and modified constraint-induced movement therapy (n=8). The mCIMT group received therapy for 90 minutes in 3 sessions per week over a period of 4 weeks. The patients receiving a combination of mCIMT and BAT were treated for the same period and frequency. The results were evaluated using the Fugl-Meyer Assessment, Action Research Arm Test (ARAT), and Motor Activity Log-Amount of Use, and Quality of Movement (MAL-AOU, QOM) assessment tools. Results: The Fugl-Meyer Assessment showed that hand and wrist performance improved significantly more in the mCIMT group than in the Combination group (p<0.05). Result from the ARAT assessment showed greater scores for gross movement in the combined group than in the mCIMT group (p<0.05). The MAL-AOU showed that there was greater improvement in the combined group than in the mCIMT group (p<0.05). Conclusion: The forced use of the more affected side can be important for the enhancement of upper extremity performance for chronic hemiparetic stroke patients during their daily activities.

Analysis and Recognition of Behavioral Response of Selected Insects in Toxic Chemicals for Water Quality Monitoring (수질 모니터링을 위한 유해 물질 유입에 따른 생물체의 행동 반응 분석 및 인식)

  • Kim, Cheol-Ki;Cha, Eui-Young
    • The KIPS Transactions:PartB
    • /
    • v.9B no.5
    • /
    • pp.663-672
    • /
    • 2002
  • In this paper, Using an automatic tracking system, behavior of an aquatic insect, Chironomus sp. (Chironomidae), was observed in semi-natural conditions in response to sub-lethal treament of a carbamate insecticide, carbofuran. The fourth instar larvae were placed in an observation cage $(6cm\times{7cm}\times{2.5cm)}$ at temperature of $18^\circ{C}$ and the light condition of 10 time (light) : 14 time (dark). The tracking system was devised to detect the instant, partial movement of the insect body. Individual movement was traced after the treatment of carbofuran (0.1ppm) for four days 2days : before treatment, 2 days : after treatment). Along with the other irregular behaviors, "ventilation activity", appearing as a shape of "compressed zig-zag", was more frequently observed after the treatment of the insecticide. The activity of the test individuals was also generally depressed after the chemical treatment. In order to detect behavioral changes of the treated specimens, wavelet analysis was implemented to characterize different movement patterns. The extracted parameters based on Discrete Wavelet Transforms (DWT) were subsequently provided to artificial neural networks to be trained to represent different patterns of the movement tracks before and after treatments of the insecticide. This combined model of wavelets and artificial neural networks was able to point out the occurrence of characteristic movement patterns, and could be an alternative tool for automatically detecting presences of toxic chemicals for water quality monitoring. quality monitoring.

Physical properties of thermoplastic material for clear aligners (투명 장치의 열가소성 재료의 올바른 이해)

  • Cha, Jung-Yul
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.542-550
    • /
    • 2016
  • Recent technological advance have greatly expanded the application of invisible orthodontic treatment using clear thermoplastic materials. However, the final outcomes using clear aligner system do not achieve the level of final goal frequently, which results in case refinement, midcourse correction, or fixed orthodontic treatment. Therefore, mechanical properties of thermoplastic materials should be considered to improve the quality of outcomes. The purposes of this special article were to evaluate the force and stress depending on the materials, deflection and thickness of thermoplastic materials and to evaluate the mechanical properties of thermoplastic materials after repeated loading. Thickness and amount of deflection rather than products and materials showed the largest effect on force and stress. In all products, at least 159 gf of force was required for more than 1.0 mm deflection or when materials with 1.0 mm thickness were deflected. Orthodontic forces delivered by thermoplastic materials depend on the materials, thickness, amount of activation, and intra-oral condition. Proper thickness of thermoplastic materials and deflection level of tooth movement should be decided for the efficient and physiologic tooth movement.

  • PDF