• Title/Summary/Keyword: Quality monitoring

Search Result 3,344, Processing Time 0.028 seconds

A study on BEMS-linked Indoor Air Quality Monitoring Server using Industrial IoT

  • Park, Taejoon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.65-69
    • /
    • 2018
  • In this paper, we propose an interworking architecture for building indoor air quality monitoring server (BEMS) using IIoT (Industrial Internet of Things). The proposed monitoring server adopts IIoT-based standard protocol so that interaction with BEMS installed in existing buildings can be performed easily. It can effectively communicate with indoor air quality measurement sensor installed in the building based on IIoT, Indoor air quality monitoring is possible. We implemented a proposed monitoring server, and confirmed the availability and monitoring of data from sensors in the building.

Water Quality Analysis in Nakdong River Tributaries Using 2012-2016 Monitoring Data (2012-2016년 모니터링 자료를 이용한 낙동강 지류·지천 수질 특성 분석)

  • Son, Younggyu;Na, Seungmin;Im, Tae Hyo;Kim, Sang-hun
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.680-688
    • /
    • 2017
  • Water quality monitoring for flow rates and BOD/COD/T-N/T-P/SS/TOC concentrations has been conducted in Nakdong river tributaries since 2011. In this study concentrations and loading rates of BOD, T-P, and TOC were analyzed to evaluate water quality monitoring stations using accumulated data at 206 tributary monitoring stations in Nakdong river 2012 ~ 2016. Average concentration ranges for 206 monitoring stations were 0.3 ~ 6.4 mg/L, 0.025 ~ 1.562 mg/L, and 0.6 ~ 10.7 mg/L for BOD, T-P, and TOC, respectively. Additionally, average loading rate ranges were 0.96 ~ 46,040 kg/d, 0.087 ~ 1,834 kg/d, and 1.51 ~ 80,425 kg/d for BOD, T-P, and TOC, respectively. Average concentration for BOD, T-P, and TOC at each monitoring station was evaluated using ambient water quality standards of rivers and water quality regulation level for medium-sized management areas. Average loading rate and specific loading rate (loading rate/drainage basin area) for BOD, T-P, and TOC at each monitoring station was considered to evaluate monitoring stations using suggested classification (BOD, TOC: -1, 1 ~ 10, 10 ~ 100, 100 ~ 1,000, and 1,000 ~ kg/d; T-P: -0.1. 0.1 ~ 1, 1 ~ 10, 10 ~ 100, and 100 ~ kg/d) Using results of this study, various water quality status maps were provided, and three evaluation methods were suggested to determine priority monitoring stations in Nakdong river for rational water quality control and tributaries basin management.

The Study of Distributed Disturbance Recording System (분산형 사고파형저장 시스템에 대한 연구)

  • Park, Jong-Chan;Lee, Se-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.30-35
    • /
    • 2008
  • In this paper, the application of power Quality monitoring based on Sampled Value(SV) which is introduced in the IEC61850 International Standard for substation communication are discussed. Firstly, while Merging Unit(MU) is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are encountered. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests less time-critical service compared to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. Lastly, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

A Case Study for Quality Confirmation and Maintenance Monitoring of Tunnel Underpassing the Han River (하저터널 품질확인 및 유지관리 계측 연구)

  • Woo, Jong Tae;Yang, Tae Seon;Koo, Jai Dong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.2
    • /
    • pp.185-194
    • /
    • 1998
  • This paper shows a case study on quality confirmation and maintenance monitoring of the tunnel underpassing the Han River. First of all, when it comes to the quality confirmation, soil investigation techniques and shotcrete core test will be improved. On the construction stages, quality control procedures are needed. Second, on the maintenance monitoring, it is the main tool to control stability and safety of the tunnel structures throughout the construction period. On the geotechnical monitoring instrumentation, some considerations such as installation of monitoring sections in time, immediate base readings, adequate reading frequency, etc - shall be improved.

  • PDF

Proposed Water Quality Monitoring Frequency for Risk Assessment in Korean Rivers and Streams (위해성평가 목적의 하천수 모니터링 빈도 연구: 국내상황을 고려한 적정빈도 제안)

  • Kwak, Jin Il;Yoon, Sung-Ji;Nam, Sun-Hwa;An, Youn-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.473-478
    • /
    • 2012
  • To protect human health and manage increasing hazardous chemicals in stream area, it is necessary to expand water quality hazardous items based on risk assessment with proper monitoring data. Also, it is essential to set up the suitable monitoring frequency to produce reliable exposure data to derive water quality guidelines. However, there has been no harmonized monitoring frequency for risk assessment in both domestic and international monitoring systems. In addition, the monitoring frequency for risk assessment has been selected as 'Research needs' in the International Conference on Deriving Environmental Quality Standards for the Protection of Aquatic Ecosystems (EQSPAE) of 2011. In this study, Cases of UNEP/WHO, EU, European countries, USEPA, ANZECC/ARMCANZ, CCME, Japan, and Korea were analyzed to propose the monitoring frequency for risk assessment. Monitoring frequencies depending on environmental conditions, monitoring object, measurement parameters, and monitoring duration were extensively collected. We observed that a monthly monitoring has been applied at most of organizations including EU, USEPA, and UNEP/WHO. In this study, monitoring frequency of minimum 6 times during 3 years were proposed to conduct the risk assessment based on the current domestic status. However, it is necessary to make agreements among interested parties, and perform additional studies about optimal monitoring frequency to protect the aquatic ecosystem and human health in Korean rivers and streams.

Design of a Water Quality Monitoring Network in the Nakdong River using the Genetic Algorithm (유전자 알고리즘을 이용한 낙동강 유역의 수질 측정망 설계에 관한 연구)

  • Park, Su-Young;Wang, Sookyun;Choi, Jung Hyun;Park, Seok Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.697-704
    • /
    • 2007
  • This study proposes an integrated technique of Genetic Algorishim (GA) and Geographic Information System (GIS) for designing the water quality monitoring networks. To develop solution scheme of the integrated system, fitness functions are defined by the linear combination of five criteria which stand for the operation objectives of water quality monitoring stations. The criteria include representativeness of a river system, compliance with water quality standards, supervision of water use, surveillance of pollution sources and examination of water quality changes. The fitness level is obtained through calculations of the fitness functions and input data from GIS. To find the most appropriate parameters for the problems, the sensitivity analysis is performed for four parameters such as number of generations, population sizes, probability of crossover, and probability of mutation. Using the parameters resulted from the sensitivity analysis, the developed system proposed 110 water quality monitoring stations in the Nakdong River. This study demonstrates that the integrated technique of GA and GIS can be utilized as a decision supporting tool in optimized design for a water quality monitoring network.

Water Quality Monitoring for Corrosion Control in Waterworks System (상수도관망 시스템의 부식제어를 위한 수질모니터링)

  • Lee, Hyun-Dong;Kwak, Phill-Jae;Lee, Ji-Eun;Kim, Yeong-Kwan;Han, Myung-Ho;Park, Young-Suk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.77-87
    • /
    • 2009
  • In existing systems, the best method inhibiting corrosion control in water distribution systems is to reduce water corrosiveness. Water corrosion can be decreased by controlling water quality through simple water treatment in treatment plants. On this research, we study the characteristics of tab water qualities in domestic areas, assessment of corrosive water quality and the method of water quality monitoring. This review presents the method of water quality monitoring which is the most applicable. Monitoring for corrosion control in waterworks system is the most proper method; It can prevent serious accidents economically and reduce civil appeals. Surely we should assess corrosive water quality in tab water, and introduce water treatment methods to control corrosive water quality before monitoring for corrosion. According to a lot of researches, it has been proved that simple water treatments can reduce the pipe corrosion. In this review we should indicate that we do not control of the corrosive water quality due to domestic conditions, we should monitor the water quality basically. Therefore, we recognize how the existing water quality can cause problems on pipeline corrosion, how to deal with it. Then it will be possible to apply water quality monitoring for corrosion control in water distribution system. Monitoring for corrosion control can be expressed by LI index, it is already known in literatures. This review presents more simple method than existing methods than existing ones we expect to apply these methods to SCADA in the future.

Environmental Impact Assessment and Environmental Monitoring in Korea (한국에서의 환경영향평가와 환경측정)

  • Kang, In-Goo;Kim, Myung-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.4 no.3
    • /
    • pp.31-39
    • /
    • 1995
  • Environmental Impact Assessment (EIA) is composed of various procedures, such as screening, scoping, inventory survey, prediction, assessment, alternative assessment, mitigation measures, and post management. Environmental monitoring data for air quality or water quality, etc. is applied in the EIA process, especially in prediction and post management. As an effective tool of environmental monitoring, the remote sensing method, introduced recently, was used in collecting nationwide data concerning ecosystem and land use. This article explains the current monitoring status in Korea. Monitoring factors include air quality, water quality, soil, ocean, odor, noise, and ecosystems. This report explains the organization of the environmental monitoring system managed by the Ministry of Environment in Korea. Furthermore, it shows the environmental criteria and environmental policies applied to EIA in Korea.

  • PDF

A Power Quality Monitoring of The Grid-connected Wind Turbine in Daegwallyeong Test Site (계통 연계 대관령 풍력실증단지에서의 전력 품질 모니터링)

  • Kwon H. J.;Kim K. H.;Jang S. I.;Yoo N. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1513-1515
    • /
    • 2004
  • This paper describe the power quality monitoring results of the grid-connected wind turbine generator in Daegwallyeong Test Site. The power quality monitoring for grid-connected wind turbine generators are important to verify their performance as the grid-connected generators. In order to measure the impacts on the grid of wind turbine generator and evaluate the performance by analyzing electrical parameters, we equipped the power quality monitoring system in the real field of the Daegwallyeong test site. The developed monitoring system gathers information by remote access through the internet. The monitoring results and the detail explanation for the developed wind turbine monitoring system is presented in the study.

  • PDF