• Title/Summary/Keyword: Quality control device

Search Result 435, Processing Time 0.027 seconds

A Study on AC Servo System for FA using High-performance DSP (고성능 DSP기반의 FA 용 AC서보 시스템에 관한 연구)

  • 최치영;홍선기;김수길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 2004
  • AC servo system has been implemented to FA system and also depends on its quality. Recently with the development of power switching device and DSP which has peripheral devices to control AC servo system, the servo technology has met a new development opportunity. A DSP based AC servo system with a 3-phase PMSM is proposed. The newly produced DSP TMX320F2812-version C which has the performance of fast speed, 150MIPS, and rich peripheral interface is used. Also space vector pulse width modulation (SVPWM) and the digital PI control are implemented to the servo system

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

A Study on Automatic Seam Tracking and Weaving Width Control for Pipe Welding with Narrow Groove (협개선 배관 용접을 위한 용접선 추적 및 위빙 폭 자동 제어에 관한 연구)

  • Moon, Hyeong-Soon;Lee, Seok-Hyoung;Kim, Jong-Jun;Kim, Jong-Cheol
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2013.12a
    • /
    • pp.73-80
    • /
    • 2013
  • From broad point of view, seam tracking has been one of main issues with respect to welding automation. Several attempts have been successful for seam tracking of fixed weaving width. As a solution of the seam tracking methods for varying groove width, the visual sensors such as CCD cameras have been adopted. Although the vision sensing techniques can achieve high accuracy, the weak point is that well-prepared vision sensor environment should be required to obtain high-quality visual measurements which can be easily affected by significant noises in industrial areas. This paper proposed an alternative seam tracking algorithm for narrow groove. A special measurement device for arc voltage, in this study, is developed to enhance the reliability of the measured welding signals. Based on the developed arc sensor algorithm, an automatic weld-width tracking algorithm is also proposed, which is able to predict the weld-position more accurately. The usefulness of the automatic weld-width tracking algorithm was well verified by applying it to gas tungsten arc welding (GTAW).

  • PDF

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극차이에 따른 동작출력 변화에 관한 연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.52-54
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Design and Implement of Terrestrial & Satellite integrated DMB receiver for Personalized Broadcasting Services (개인 휴대형 방송 서비스를 위한 지상파/위성 통합 DMB 수신기 설계 및 구현)

  • Cho, Yong-Hoon;Kim, Won-Yong;Choi, Soon-Pil;Oh, Se-In;Choi, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.289-291
    • /
    • 2007
  • The Digital Multimedia Broadcasting(DMB) system is developed to offer high quality audio-visual multimedia contents to the uses by the various portable terminals in the mobile environment. Integrated complex reception platform is required to receive multimedia broadcasting services transmitted from various transmission media. In this paper, we present the design and implementation technic for providing the both of terrestrial and satellite DMB services simultaneously using the same hardware platform. The implemented complex receiving terminal to accommodate these DMB services simultaneously need composed of it RF module. it baseband module, it complex control module and the complex de-multiplexer module. The complex control module is designed using uClinux operating system. The complex de-multiplexer, which perform the functions of the address decoder and each DMB stream de-multiplexer, is implemented. with FPGA device. The implemented platform is tested in a real environment and its performance is satisfied with required performance criteria.

  • PDF

Nonlinear Moving Picture Editor for Multiple Watermarking (다중 워터마킹을 지원하는 비선형 동영상 편집기)

  • 윤석민;한경섭;정순기
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.2
    • /
    • pp.124-129
    • /
    • 2002
  • Currently, image processing are used widely and have various types of characteristics with the applications of VOD(Video on demand), the web casting services, the video conference systems and virtual realities. Using the scene change, at every time of video image transitions, an editor can classify the video context and also require a function of in(Boxing insertion. Digital watermarking provides a solution to illegal copying of digital contents and has many other useful applications, including web broadcast monitoring, transaction tracking, authentication, copy control and device control. The Purpose of this thesis is to implement of nonlinear moving picture editor for the multiple watermarking. For the effective watermarking performance, this thesis considers the protection of image quality reduction and robustness for hiding information concurrently.

  • PDF

Integrated Operation of Power Conversion Module for DC Distribution System (직류 배전 시스템을 위한 전력 변환 모듈의 통합 운전)

  • Lee, Hee-Jun;Shin, Soo-Choel;Hong, Suk-Jin;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.240-248
    • /
    • 2014
  • It is DC power that Output of renewable energy being recently developed and researched. Also, demand of DC power will expect to proliferate due to increase of digital load. Thus, DC distribution system providing high quality of power and reliability has emerged as a new distribution system. If the conventional distribution systems are substituted by proposed DC distribution system, the output of renewable energy can be connected with distribution systems under minimum power conversion. Therefore, in the event of connection with DC load, it can construct an efficient distribution system. In this paper, the integrated parallel operation of power conversion module for DC distribution system is proposed. Also, this paper proposed modularization of power conversion devices for DC distribution system and power control for parallel operation of large capacity system. DC distribution system consists of three power conversion modules such as AC/DC power conversion module 2 set, ESS module 1 set. DC distribution system controls suitable operation depending on the status of the DC power distribution system and load. Integrated operation of these systems is verified by simulation and experiment results.

A Quality-control Experiment Involving an Optical Televiewer Using a Fractured Borehole Model (균열모형시추공을 이용한 광학영상화검층 품질관리 시험)

  • Jeong, Seungho;Shin, Jehyun;Hwang, Seho;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.17-30
    • /
    • 2020
  • An optical televiewer is a geophysical logging device that produces continuous high-resolution full-azimuth images of a borehole wall using a light-emitting-diode and a complementary metal-oxide semiconductor image sensor to provide valuable information on subsurface discontinuities. Recently, borehole imaging logging has been applied in many fields, including ground subsidence monitoring, rock mass integrity evaluation, stress-induced fracture detection, and glacial annual-layer measurements in polar regions. Widely used commercial borehole imaging logging systems typically have limitations depending on equipment specifications, meaning that it is necessary to clearly verify the scope of applications while maintaining appropriate quality control for various borehole conditions. However, it is difficult to directly check the accuracy, implementation, and reliability for outcomes, as images derived from an optical televiewer constitute in situ data. In this study, we designed and constructed a modular fractured borehole model having similar conditions to a borehole environment to report unprecedented results regarding reliable data acquisition and processing. We investigate sonde magnetometer accuracy, color realization, and fracture resolution, and suggest data processing methods to obtain accurate aperture measurements. The experiment involving the fractured borehole model should enhance not only measurement quality but also interpretations of high-resolution and reliable optical imaging logs.

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

Comparative Study on Biological Technology in Artificial Floating Island: Application of Media and Daphnia to Algal Biomass Control (인공부도의 생물학적 처리 기술 비교 연구: 인공부도의 조류의 저감 효과 개선을 위한 여재와 물벼룩 적용)

  • Jin, Mei-Yan;Chang, Kwang-Hyeon;Kim, Tae-Hoon;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.1
    • /
    • pp.83-91
    • /
    • 2018
  • Media (bio-stone), aquatic macrophytes (Oenanthe javanica) and herbivorous cladoceran (Daphnia similoides) have been used in artificial floating island (AFI) systems for water pollution control. Efficiency in chl-a concentration controlling of AFI was tested using different combinations of each device: G-BD-mixture bio-stone and Daphnia similoides, G-OB-mixture Oenanthe javanica and bio-stone, G-BOD-mixture bio-stone, Oenanthe javanica and Daphnia similoides, and the out-put water quality improvement was compared with G-C-control (no device was applied). We analyzed removal efficiency of chl-a concentration and nutrient concentrations in the artificially eutrophic water in the laboratory experimental facility. The results showed average removal rates of Chlorophyll a, TN and TP for different four groups: 69.24%, 16.61%, -0.61%; 68.39%, 14.11%, 10.52%; 78.30%, 6.69%, 25.09%; 35.42%, -3.47%, -25.18%, respectively. The results have suggested that the mixture of media, plants and zooplankton is the most efficient combination for Chlorophyll a control, while the mixture of macrophytes and bio-stone have better efficiency nutrient control.