• 제목/요약/키워드: Quality Measurement Method

Search Result 1,471, Processing Time 0.035 seconds

NDIR Multi-Gas Measurement System for Air Quality based on Wireless Sensor Network (무선센서네트워크 기반 공기질 측정을 위한 비분산적외선 복합가스측정시스템)

  • Paik, Seung Hyun;Lee, Jun Yeong;Jung, Sang Woo;Park, Hong Bae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.5
    • /
    • pp.299-304
    • /
    • 2016
  • As public interest in air quality and environment problem is increasing, many researches are being carried out the gas measurement system. Especially, Non-dispersive infrared (NDIR) measurements using Beer-Lambert gas sensing principle with very high selectivity and long life time are noted for reliable method. It is possible to detect various gases such as carbon dioxide (CO2), carbon monoxide (CO), and nitrogen dioxide (NO2), but many researches are mostly concentrated on CO2 sensor. The multi-gas measuring instrument is high price and unwieldy, therefore it is not suitable for wide area required numerous instrument. So we study the NDIR multi-gas measurement system for air quality based on wireless sensor network, and experiment the realized measurement system.

Time Synchronization of the Monitoring Data for the VoIP User Assessment of Voice Quality Measurement (인터넷전화 이용자 체감품질 측정을 위한 측정데이터 간의 시간동기화)

  • Kweon Tae-Hoon;Hwang Hyae-Jeong;Lee Seog-Ki;Song Han-Chun;Won Seung-Young
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.4
    • /
    • pp.227-236
    • /
    • 2005
  • We study, in terms of VoIP user assessment of voice quality, the synchronization of measurement system is important. Commonly the synchronization system uses NTP(Network Time Protocol) or GPS(Global Positioning System), these synchronization method has time error of distance, system overhead of data processing, and system specialized clock error. we propose and implement the synchronization method to correct time error between two measurement system in the internet. So the time synchronization of systems can get time error, then user assessment of voice quality become reliable.

  • PDF

A Study of Subjective Speech Quality Measurement in VoIP (VoIP 음질의 주관적 평가에 관한 연구)

  • 강영도;강진석;최연성;김장형
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.2
    • /
    • pp.279-287
    • /
    • 2001
  • In this paper, we discuss the scale of subjective speech quality measurement over VoIP(Voice over IP) network which is a component of broadband networks. Objective parameters of multimedia services like PSNR or jitter can easily measured and defined, but these factors are not easily meet the user's perceptual recognition. We suggest the speech quality measurement scale through the subjective measurement for end-to-end speech quality composed of sender-side quality, transmission quality, receiver-side quality, which provide the degree of correctness of representation of speaker, the degree of impairment caused by various factors, the degree of recognition of processed speech, respectively. Also, we examined the proposed method and verify it's availability.

  • PDF

Optimization Methodology of Quality Measurement of Digital Correlator (디지털 상관기 성능 측정의 최적화 기법)

  • Yeom, Jae-Hwan;Jeong, Goo-Young;Roh, Duk-Gyoo;Oh, Se-Jin;Kim, Kwang-Dong;Lee, Chang-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.371-372
    • /
    • 2006
  • In this paper, we propose a method that measures quality of digital correlator. Quality of digital correlator in field of image composition of radio astronomy have as important position for acquisition of radio wave image with high precision. Digital correlator should have wide bandwidth and high precision to study on deep space. Digital correlator, therefore, should be designed to have high speed processing and high precision. But, real time measurement of quality of digital correlator using acquisition data is difficult to compare accuracy of result because digital correlator should process a large quantity of data with high speed. Measurement method of quality, also, has intricate implementation of experiment equipment. this paper present methods that compose experiment equipment without external installation easily and verify quality of digital correlator perfectly.

  • PDF

Estimations of Measurement System Variability and PTR under Non-normal Measurement Error (비정규 측정오차의 경우 측정시스템 변동과 PTR 추정)

  • Chang, Mu-Seong;Kim, Sang-Boo
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2006.11a
    • /
    • pp.199-204
    • /
    • 2006
  • ANOVA is widely used for measurement system analysis. It assumes that the measurement error is normally distributed, which may not be seen in some industrial cases. In this study, the estimates of the measurement system variability and PTR (precision-to-tolerance ratio) are obtained by using weighted standard deviation for the case where the measurement error is non-normally distributed. The Standard Bootstrap method is used for estimating confidence intervals of measurement system variability and PTR. The point and confidence interval estimates for the cases with normally distributed measurement error are compared to those with non-normally distributed measurement errors through computer simulation.

  • PDF

A Study on the Quality Characteristics of Leather Shoe Adhesives(I) -Ladies' Leather-shoe- (구두용 접착제의 품질 특성에 관한 연구(I) -여성 가죽구두-)

  • 서교택;이상신
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.54
    • /
    • pp.137-144
    • /
    • 2000
  • The chloroprene adhesive for ladies' shoe-making applied by the cementing method in KS G 3116 has been evaluated.. For the quality test of adhesive for pump whole cut vamp using chloroprene adhesive, general property and adhesion strength were measured and duration for environmental exposure was tested. Also, a list of experiments for field application was prepared. In case of adhesion-strength measurement,, the KS G 3116 method of peel strength at end of toe was found to be reasonable by measurement through a whole length, toe to heel seat on feather edge.

  • PDF

A Study on Measurement Method of Audio Playback Time for Standardization of Wireless Earphone Quality (무선이어폰 품질 표준화를 위한 오디오 재생 시간 측정법에 관한 연구)

  • HAN, Munhwan;Jeong, Inho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.141-151
    • /
    • 2022
  • Wireless earphones are products that are consumed together with smart devices (mobile phones, etc), and there is no twisting and convenience compared to general earphones. However, due to the lack of information on the quality of wireless earphones, consumers tend to purchase products based on brand awareness, and manufacturers deliver information to consumers based on different standards for each product due to the lack of standards for measurement methods for quality evaluation. In particular, the playback time of wireless earphones is a factor that can directly affect consumers' purchases, so it is necessary to prepare a standardized test method to properly measure it. This paper introduces the current status of wireless earphones and related standard trends, and proposes a method for measuring the audio playback time of wireless earphones developed through this. In addition, this measurement method will be proposed as an international standard (IEC) after being established as the national standard, the Korean Industrial Standard (KS).

Finite Element Analysis of Nonlinear Behavior of a Column Type Sensing Element for Load Cell According to Design Parameters (기둥형 로드셀 감지부의 설계변수에 따른 비선형 거동해석)

  • Lee, Chun-Yeol;Gang, Dae-Im
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.6 s.177
    • /
    • pp.1540-1546
    • /
    • 2000
  • Recently, force measurement systems are commonly used in many industrial fields and the precision of the measurement system is getting more important as the industry needs more precise tools and in struments to make high quality products. However, a high precision force measurement system is hard to make unless we know precisely the causes, quality and quantity of measurement errors in advance. In this work, many possible mechanical causes of measurement errors are reviewed including ratio of length to diameter of sensing part, radius of contact area, radius of bearing part, ratio of material properties and change of boundary conditions. Also, the measurement errors are analyzed by nonlinear finite element method and the nonlinear behavior of the errors are investigated. The results can be used to design force measurement systems and expected to be very useful especially for compact type load cells.

Quality Measurement Process Management Using Defect Data of Embedded SW (Embedded SW의 품질 측정 프로세스 관리 방법에 관한 연구)

  • Park, Bok-Nam
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.713-721
    • /
    • 2003
  • The time to market and productivity of embedded system needs a quality measurement process management of embedded software. But, defect management without preemptive analysis or prediction is not useful for quality measurement process management. This subject is focused on the defect that is one of the most important attributes of software measure in the process. Defining of defect attribute and quality measurement process management is according to understanding of embedded sw characteristics and defect data. So, this study contributes to propose the good method of the quantitative based on defect management in the test phase of sw lifecycle.

  • PDF

Efficiency Study of Measurement Method by Flow Duration (유황별 유속측정 방법에 따른 유효성 연구)

  • Ham, Sang In;Lee, Jeong Hwan;Kim, Dae Young;Ha, Don Woo;Kim, Yoon Soo;Jung, Kang-Young;Lee, Yeong Jae;Kim, Gyeong Hyeon;Kim, Young Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.462-469
    • /
    • 2018
  • There are differences in method and cycle of flow rate survey depending on purpose of the operating department. To verify and use results of flow data according to the purpose, flow data of the directly measured and tele monitoring system were compared to verify validity. Flow measurement in the Ministry of Environment is aimed at setting up a standard flow of target water quality for water quality management and securing flow data of low and normal water level seasons for water quality evaluation. In this study, correlation analysis result ($R^2$) of same time zone data by direct measurement and tele monitoring system (TMS) at Seombon D point, a unit watershed of Seomjin river, for six years ('10 ~ '15) according to implementation of Total Daily Maximum Load (TDML) was wading 0.716, boating 0.962 and on bridge 0.943, and effectiveness of measurement method was verified by characteristics of flow duration as a season of dry and low-water; normal and high water are appropriate for wading, boating, and on bridge respectively. Results revealed it is reasonable to use directly measured results using the wading and boating method for low water level and dry seasons, and TMS data for rainy seasons. It can be used important data for future policy decisions.