• Title/Summary/Keyword: Quality Measurement Method

Search Result 1,475, Processing Time 0.028 seconds

Signal qualification method for high density disk (고밀도 디스크를 위한 신호 품질 평가 방법)

  • Park Hyun-Soo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.53-57
    • /
    • 2005
  • In order to measure signal quality of optical disc such as CD or DVD, jitter is used traditionally. The signal attained from a disc by optical pick-up is processed by analog circuits. And then, binary signal can be obtained by using proper silcer. After the signal is changed into binary format, jitter is calculated as a time difference between the binary signal and the reference time. Jitter is used to express the signal quality. In this paper, a new method that is able to offer more precise measurement of the signal quality fur high density optical disc than the jitter is proposed. We named it LPSNR (Level Peak Signal to Noise Ratio). The relationship between bER (bit error rate) and LPSNR is shown in the paper.

  • PDF

The Color Reproduction Property Evaluation of Domestic Offset Prints (II) - Using Colorimetric Method - (국산 오프셋 인쇄물의 색재현 특성에 대한 평가(II) - 색차 측정법에 의한 평가 -)

  • Kim, Jin-Young;Kang, Sang-Hoon
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.24 no.1
    • /
    • pp.45-57
    • /
    • 2006
  • Offset lithography is the most widely used printing process in domestic printing industry, but there are no industry-wide specifications for press control to assure consistent quality across printing plants. As printing becomes more of a commodity and less of an art, it is necessary to develop a print quality specification standard suitable for Korea offset printing field. This study aims to contribute to improving the quality of domestic offset color prints by comparative study on color reproduction properties of 2 kinds of domestic process color ink composed of C(cyan), M(magenta), Y(yellow) and K(black) and of 3 kinds of domestic coated paper, using colorimetric color measurement method.

  • PDF

Practical Measurement on Education Outcome Through Multi-Evaluations (다면적 평가를 통한 교육성과 평가도구 개발 및 분석연구)

  • Baik, Ran
    • Journal of Engineering Education Research
    • /
    • v.15 no.6
    • /
    • pp.98-102
    • /
    • 2012
  • This paper diagnose subjects and measures the learning ability of students based on the goal of developing an assessment tool for education productivity based on multi-aspect evaluation conducted by ICEE at Honam University. Furthermore, develop an assessment tool for education productivity that provides a motive to bring detailed improvements in teaching methods through the diagnosis. In addition, a method for compensating the issues and improving the quality of subject is suggested to develop learning ability of students through applying the assessment tool. An integrated operated system of CQI is desired to be built along with quality improvement of education through measuring academic quality by studying the methods for enhancing academic and learning ability achievement from analysis of the curriculum provided in the "ABEEK program". Through this study the current state of education productivity is presented through analyzing the difference between students who participated in the "ABEEK program" and who did not participate, and operating a comparison between the student's comprehension on their majors and liberal arts by the multi-aspect evaluation that has been conducted for 2 years.

The Color Reproduction Property Evaluation of Domestic Offset Prints (I) - Using Densitometric Method - (국산 오프셋 인쇄물의 색재현 특성에 대한 평가(I) - 광학농도 측정법에 의한 평가 -)

  • Kim, Jin-Young;Kang, Sang-Hoon
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.23 no.2
    • /
    • pp.77-92
    • /
    • 2005
  • Offset lithography is the most widely used printing process in domestic printing industry, but there are no industry-wide specifications for press control to assure consistent quality across printing plants. As printing becomes more of a commodity and less of an art, it is necessary to develop a print quality specification standard suitable for Korea offset printing field. This study aims to contribute to improving the quality of domestic offset color prints by comparative study on color reproduction properties of 3 kinds of domestic process color ink composed of C(cyan), M(magenta), Y(yellow), and K(black), and of 3 kinds of domestic coated paper, using densitometric color measurement method.

  • PDF

Uncertainty Evaluation of the Analysis of 11-Nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol in Human Urine by GC/MS (GC/MS를 이용한 소변 중 대마 대사체 분석의 측정불확도 평가)

  • Kim, Jin-Young;Jeong, Jae-Chul;Suh, Sung-Ill;Suh, Yong-Jun;Lee, Jeong-Jik;Kim, Jong-Sang;In, Moon-Kyo
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.480-487
    • /
    • 2008
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH), the major metabolite of ${\Delta}^9$-tetrahydrocannabinol, in urine sample by solid-phase extraction (SPE) and GC/MS detection. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day and inter-person validation were performed using statistical analysis of several indicative factors. Measurement uncertainty associated with target analyte in real forensic samples was estimated using quality control (QC) data. Traceability of measurement was established through traceable standards, calibrated volumetric glassware and volume measuring device. The major factors of contribution to combined standard uncertainty, were calibration linearity, inter-day repeatability and inter-person reproducibility, while those associated with preparation of analytical standards and sampling volume were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method was 12.05% for THCCOOH.

Optimization of Contaminated Land Investigation based on Different Fitness-for-Purpose Criteria (조사목적별 기준에 부합하는 오염부지 조사방법의 최적화 방안에 관한 연구)

  • Jong-Chun Lee;Michael H. Ramsey
    • Economic and Environmental Geology
    • /
    • v.36 no.3
    • /
    • pp.191-200
    • /
    • 2003
  • Investigations on the contaminated lands due to heavy metals from mining activities or hydrocarbons from oil spillage for example, should be planned based on specific fitness-for-purpose criteria(FFP criteria). A FFP criterion is site specific or varies with situation, based on which not only the data quality but also the decision quality can be determined. The limiting factors on the qualities can be, for example, the total budget for the investigation, regulatory guidance or expert's subjective fitness-for-purpose criterion. This paper deals with planning of investigation methods that can satisfy each suggested FFP criterion based on economic factors and the data quality. To this aim, a probabilistic loss function was applied to derive the cost effective investigation method that balances the measurement uncertainty, which estimates the degree of the data quality, with the decision quality. In addition, investigation planning methods when the objectives of investigations do not lie in the classification of the land but simply in producing the estimation of the mean concentration of the contaminant at the site(e.g. for the use in risk assessment), were also suggested. Furthermore, the efficient allocation of resources between sampling and analysis was also devised. These methods were applied to the two contaminated sites in the UK to test the validity of each method.

The realtime measurement of burrs on sheet metal using the semiconductor laser (반도체 레이저를 이용한 박판 버의 실시간 측정)

  • 홍남표;신홍규;김헌영;김병희
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.107-110
    • /
    • 2003
  • The sheet metal shearing process is normally used in the precision elements such as semi-conductor components. In precision elements, burrs usually reduce the quality of machined parts and cause interference, jamming and misalignment during assembly procedures and because of their sharpness, they can be safety hazard to personnel. Furthermore, not only burrs are hard to predict and avoid, but also deburring, the process of removing burrs, is time-consuming and costly. In order to get the burr-free parts, therefore, we developed the precise burr measuring system using the laser. Using the X-Y precious table, we used vertical measuring method. Through the laser measurement system, we gain the minute analog signal, so this signal was amplified by the electric circuit. Finally, we gained the realtime burr data using A/D converter, PC. By introducing the novel laser measuring method which employing vertical measurement mechanism, we could get fast and precious burr data. Through the experiments, the accuracy of the developed system is proved. The burr height measured during the punching process can be used for automatic deburring and in-situ aligning.

  • PDF

MEASUREMENT OF $^{235}U$ ENRICHMENT USING THE SEMI-PEAK-RATIO TECHNIQUE WITH CdZnTe GAMMA-RAY DETECTOR

  • Ha, J.H.;Ko, W.I.;Lee, S.Y.;Song, D.Y.;Kim, H.D.;Yang, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.275-279
    • /
    • 2001
  • In uranium enrichment plants and nuclear fuel fabrication facilities, exact measurement of fissile isotope enrichment of uranium is required for material accounting in international safeguards inspection as well as process quality control. The purpose of this study was to develop a simple measurement system which can portably be used at nuclear fuel fabrication plants especially dealing with low enriched uranium. For this purpose, a small size CZT (CdZnTe) detector was used, and the detector performance in low uranium gamma/X -rays energy range was investigated by use of various enriched uranium oxide samples. New enrichment measurement technique and analysis method for low enriched uranium oxide, so-called, 'semi-peak ratio technique' was developed. The newly developed method was considered as an alternative technique for the low enrichment and would be useful to account nuclear material in safeguarding activity at nuclear fuel fabrication facility.

  • PDF

A Technique to Improve the Readability of Ancient Inscription by Using Optical Triangulation Measurement Principle (광삼각법 측정 원리를 이용한 금석문 가독성 향상 방법)

  • Lee, Geun-Ho;Ko, Sun-Woo;Choi, Won-Ho
    • Journal of Information Technology Services
    • /
    • v.11 no.sup
    • /
    • pp.103-111
    • /
    • 2012
  • In epigraph field to study ancient scripts, alternative readability improvement technologies have been developed to replace existing rubbing method which has low resolution and causes surface pollution of heritages from the viewpoints of extraction process and used materials. Recently many methods which are based on analysis of pixel data for extracting outlines of the specific image have been developed with advancement of image processing techniques. But these methods are not applicable and the results are not satisfied in the damaged inscriptions which are weathered by wind and rain for a long time and in the narrowed one. In this paper laser scanning techniques which uses optical triangulation measurement principle are developed to minimize scanning error. The proposed techniques are consisted of 3 parts:(1) the understanding of optical triangulation measurement principle to find scanning guideline (2) determinations of points interval, scanning distance and scanning angle to guarantee scanning data quality (3) identification of valid point data area which will be used in registration process. The proposed character identification method contributed in decoding an ancient inscription on SeukBingGo in Kyungju.

Accuracy improvement of respiration rate based on photo-plethysmography by enhancing motion artifact (광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상)

  • Huh, Young-Jung;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.447-453
    • /
    • 2008
  • Respiration rate is one of the important vital signs. Photo-plethysmography (PPG) measurement especially on a finger has been widely used in pulse oximetry and also used in estimating respiration rate. It is well known that PPG contains respiration-induced intensity variation (RIIV) signal. However, the accuracy of finger PPG method has been controversial. We introduced a new technique of enhancing motion artifact by respiration. This was achieved simply by measuring PPG on the thorax. We examined the accuracy of these two PPG methods by comparing with two existing methods based on thoracic volume and nostril temperature changes. PPG sensing on finger tip, which is the most common site of measurement, produced 6.1 % error. On the other hand, our method of PPG sensing on the thorax achieved 0.4 % error which was a significant improvement. Finger PPG is sensitive to motion artifact and it is difficult to recover fully small respiratory signal buried in waveform dominated by absorption due to blood volume changes. Thorax PPG is poor to represent blood volumes changes since it contains substantial motion artifact due to respiration. Ironically, this inferior quality ensures higher accuracy in terms of respiration measurement. Extreme low-cost and small-sized LED/silicon detector and non-constrained reflection measurement provide a great candidate for respiration estimation in ubiquitous or personal health monitoring.