• Title/Summary/Keyword: Quality Measurement Method

Search Result 1,469, Processing Time 0.031 seconds

Research on water quality and flow rate measurement by applying GPS electronic Floater standard experimental method when water environmental chemical accidents occur (수환경 화학사고 발생시 GPS 전자부자 표준실험법 적용을 통한 수질-수리 측정에 대한 연구)

  • Lee, Chang Hyun;Nam, Su Han;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.845-853
    • /
    • 2023
  • Recently, along with the increase in chemical accidents, the number of accidents-related disasters has been increasing continuously since 2012, and when looking at the hydrogen fluoride incident which is a representative example of domestic chemical incidents, there is insufficient technology applicable to the incident site. The result was that the damage spread. Therefore, in this paper, we will adapt the water pollution accident response system to a location-based approach, and introduce a measurement method for alternative index tracking using a GPS electronic floater of a location-based index measurement method for real-time response in the water environment when a chemical incident occurs. The research target area is Gumi City, which is the area where the hydrogen fluoride incident occurred, and Gamcheon is selected, and alternative tracking using GPS electronic floater is conducted in the corresponding target area through water quality and flow measurement. As a result, it is possible to measure water quality and flow at the same time in tracker experiments using GPS electronic floater based on the research results, it is believed that using GPS electronic floater will be of great help in disaster response systems for spill incidents in the river.

Dwelling Quality Evaluation of Rural Houses Constructed with Industrialized Wall Structures (공업화 구조 농촌주택의 거주성 평가)

  • 최윤정;윤정숙
    • Journal of the Korean housing association
    • /
    • v.13 no.5
    • /
    • pp.9-20
    • /
    • 2002
  • The purpose of this study are to evaluate the dwelling quality of rural houses constructed with industrialized wall structures(ALC; Autoclaved Light weight Concrete, SRC; Steel Fiber Reinforced Concrete, ST'L; Steel Framed Insulating Panel), and to establish a method of dwelling quality evaluation. The questionnaire survey by mail was done, for investigating the residents' responses to indoor environment, durability, and economic aspect. The respondents are 118 residents living in rural houses constructed with industrialized wall structures. Physical elements of indoor environment(temperature, humidity, air quality, and noise level) were measured in three sample houses, which were selected considering of architectural characteristics. The findings are as follows; 1) As a result of questionnaire survey, residents' responses to dwelling quality are generally positive. 2) As a result of measurement, indoor environments of sample houses are in relatively comfortable condition. 3) As a summary of research, ALC and ST'L are evaluated as recommendable structures for a rural house.

An Approach to Measurement of Water Quality Factors and its Application Using NOAA satellite Data

  • Jang, Dong-Ho;Jo, Gi-Ho;Chi, Kwang-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.363-370
    • /
    • 1999
  • Remotely sensed data is regarded as a potentially effective data source for the measurement of water quality and for the environmental change of water bodies. In this study, we measured the spectral reflectance by using multi-spectral image of low resolution camera(LRC) which will be loaded in the OSMI multi-purpose satellite(KOMPSAT) scheduled to be launched on 1999 to use the data in analyzing water pollution. We also investigated the possibility of extraction of water quality factors in water bodies by using remotely sensed low resolution data such as NOAA/AVHRR. In this study, Shiwha-District and Sang-Sam Lake was set up as the subject areas for the study. In this part of the study, we measured the spectral reflectance of the water surface to analyze the radiance of the water bodies in low resolution spectral band and tried to analyze the water quality factors in water bodies by using radiance feature from another remotely sensed data such as NOAA/AVHRR. As the method of this study, first, we measured the spectral reflectance of the water surface by using SFOV( Single Field of View) to measure the reflectance of water quality analysis from every channel in LRC spectral band(0.4~O.9${\mu}{\textrm}{m}$). Second, we investigated the usefulness of ground truth data and the LRC data by measuring every spectral reflectance of water quality factors. Third, we analyzed water quality factors by using the radiance feature from another remotely sensed data such as NOAA/AVHRR. We carried out ratio process of what we selected Chlorophyll-a and suspended sediments as the first factors of the water quality. The results of the analysis are below. First, the amount of pollutants of Shiwha-Lake has been increasing every you since 1987 by factors of eutrophication. Second, as a result of the reflectance, Chlorophyll-a represented high spectral reflectance mainly around 0.52${\mu}{\textrm}{m}$ of green spectral band, and turbidity represented high spectral reflectance at 0.57${\mu}{\textrm}{m}$. But suspended sediments absorbed high at 0.8${\mu}{\textrm}{m}$. Third, Chlorophyll-a and suspended sediments could have a distribution chart as a result of the water quality analysis by using NOAA/AVHRR data.

  • PDF

Comparison of the Real-time Measurements for PM2.5 and Quality Control Method (PM2.5 자동측정장비 비교 및 정도관리 방안)

  • Park, Mikyung;Park, Jin Su;Jo, Mira;Lee, Yong Hwan;Kim, Hyun Jae;Oh, Jun;Choi, Jin Soo;Ahn, Joon Young;Hong, You Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).

A Study on the Resizable Target Size Estimation Method for Imaging Target Tracking (재설정 가능한 표적 크기 추정 알고리즘 연구)

  • Jung, Yun Sik;Rho, Shin Baek
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.842-848
    • /
    • 2014
  • In this paper, an improved method RMBE (Resizable Model Based target size Estimator) is presented for SDIIR (Strap Down Imaging Infrared) seekers. At the target engaging scenario, the IIR target measurement is separated by various parts. In this case, target object changing is important to accurate target intercept. Therefore, we need robust target size estimator. Our proposed method resize estimated target size with MC-1 (Markov Chain I) for accurate target size estimation. The performance of proposed method is tested at IIR target tracking of target intercept scenario. The experiment results show that the proposed RMBE has improved performance than MBE.

A Study on Standard Testing Method for Type Approval of DSC Using MF/HF (MF/HF용 DSC의 형식검정을 위한 표준 시험방법)

  • 이동식;김기문
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.4
    • /
    • pp.63-82
    • /
    • 1995
  • This paper is a study on standard testing method for type approval of DSC which is the main structure of the terrestrial communication. As authority inspecting offices and producers have no experience for type approval of relative equipments as adapting GMDSS. In this paper, it is to be improved the understanding for type approval ; a system, standard of technic and testing methods, etc and make better quality of relative equipments. Additionally it could help quality and quantity improvement in all radiocommunication parts. Of course, the regulation for type approval had made but most makers didn't know it correctly, so the method of solution have been studied. By result of this study, with comparision and analysis of structure and a condition of efficiency with adapting GMDSS is could help some problems slove in the field and gave testing method of machinery and tools, electrical conditions, came out measurement and did ways standard efficiency.

  • PDF

Low-band Extension of CELP Speech Coder by Recovery of Harmonics (고조파 복원에 의한 CELP 음성 부호화기의 저대역 확장)

  • Park Jin Soo;Choi Mu Yeol;Kim Hyung Soon
    • MALSORI
    • /
    • no.49
    • /
    • pp.63-75
    • /
    • 2004
  • Most existing telephone speech transmitted in current public networks is band-limited to 0.3-3.4 kHz. Compared with wideband speech(0-8 kHz), the narrowband speech lacks low-band (0-0.3 kHz) and high-band(3.4-8 kHz) components of sound. As a result, the speech is characterized by the reduced intelligibility and a muffled quality, and degraded speaker identification. Bandwidth extension is a technique to provide wideband speech quality, which means reconstruction of low-band and high-band components without any additional transmitted information. Our new approach considers to exploit harmonic synthesis method for reconstruction of low-band speech over the CELP coded speech. A spectral distortion measurement and listening test are introduced to assess the proposed method, and the improvement of synthesized speech quality was verified.

  • PDF

Study on the Measurement-Based Packet Loss Rates Assuring for End-to-End Delay-Constrained Traffic Flow (지연 제한 트래픽 흐름에 대한 측정 기반 패킷 손실률 보장에 관한 연구)

  • Kim, Taejoon
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1030-1037
    • /
    • 2017
  • Traffic flows of real-time multimedia services such as Internet phone and IPTV are bounded on the end-to-end delay. Packets violating their delay limits will be dropped at a router because of not useful anymore. Service providers promise the quality of their providing services in terms of SLA(Service Level Agreement), and they, especially, have to guarantee the packet loss rates listed in the SLA. This paper is about a method to guarantee the required packet loss rate of each traffic flow keeping the high network resource utilization as well. In details, it assures the required loss rate by adjusting adaptively the timestamps of packets of the flow according to the difference between the required and measured loss rates in the lossy Weighted Fair Queuing(WFQ) scheduler. The proposed method is expected to be highly applicable because of assuring the packet loss rates regardless of the fluctuations of offered traffic load in terms of quality of services and statistical characteristics.

Signal qualification method for high density disk (고밀도 디스크를 위한 신호 품질 평가 방법)

  • Park Hyun-Soo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.53-57
    • /
    • 2005
  • In order to measure signal quality of optical disc such as CD or DVD, jitter is used traditionally. The signal attained from a disc by optical pick-up is processed by analog circuits. And then, binary signal can be obtained by using proper silcer. After the signal is changed into binary format, jitter is calculated as a time difference between the binary signal and the reference time. Jitter is used to express the signal quality. In this paper, a new method that is able to offer more precise measurement of the signal quality fur high density optical disc than the jitter is proposed. We named it LPSNR (Level Peak Signal to Noise Ratio). The relationship between bER (bit error rate) and LPSNR is shown in the paper.

  • PDF