• Title/Summary/Keyword: Quality Engineer

Search Result 205, Processing Time 0.022 seconds

Development of a Simple In-Situ Data Logger (간단한 현장 데이타 수집장치의 개발에 관한 연구)

  • Yeo, Woo-Kwang;Yoon, Byung-Man;Lee, Jong-Kuk
    • Water for future
    • /
    • v.29 no.2
    • /
    • pp.249-260
    • /
    • 1996
  • There have been easily found a number of examples that misleading or unreasonable measuring data set of physical variables are often produced in the field and the laboratory. The primary reason is that the specific requirements of civil engineers are initially disregarded in designing the experimental apparatus. It results from a lack of mutual understanding and co-operating between the user group and the maker. Therefore, their fundamental knowledge and apprehension become indispensible in order to obtain measuring data with high confidence and good quality In this study it is shortly explained the basic structure and the operation system of the experimental equipments commonly used at the present. A simple measuring set is developed which is quite easy for a general civil engineer to design and operate without any other specialty of mostly electricity electronics. Based upon this requirement, one of data logger named PPDL8 is newly designed by making use of the parallel port in the personal computer, consisting of multi-channels able to measure 8 different point values simultaneously. It can also use many valuable sub-programs existing in PC because the user makes his own programs necessary for measurement, by himself. Of all things, it has a great advantage to increase the applicability of field measurements much larger when adopting the notebook computer to operate with small battery only. In addition this study gives, in fact, the excellent agreements of in-situ field variables by showing their measuring results of temperature, distance and turbidity.

  • PDF

A Study on Optimal Reinforcing Type of Precast Retaining Wall Reinforced by Micropiles (마이크로파일로 보강된 프리캐스트 콘크리트 옹벽의 최적보강형태에 관한 연구)

  • Kim, Hong-Taek;Park, Jun-Yong;Yoo, Chan-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.11
    • /
    • pp.89-99
    • /
    • 2006
  • The PCRW (Precast Concrete Retaining Wall) has many advantages compared with cast in place concrete retaining wall : shorter construction period, excellency of quality and minimum interference with the adjacent structure and traffics. However, shallow foundation type of PCRW, which has comparatively better ground condition, has some disadvantages such as difficulty in transportation and higher cost due to the size of PCRW being expanded by resisting only with self-weight if there is no other supplementary reinforcement. The presented study, in order to complement such disadvantages of PCRW, have applied the micropile method. The micropile method has advantages like low-cost and high-efficiency and does not require huge space, because it can be executed with small size equipment. However, the mechanical behavior characteristics of the PCRW reinforced by micropile, which is installed to improve the reinforcement effect, is not yet clearly identified and there is no suggested standard as to the length, diameter, install angle and install position of micropiles. Hence, this method is yet being designed depend on engineer's experience. In this study, various laboratory model tests as to sliding and overturning were performed in order to identify and present the optimum type of reinforcement and reinforcement effect of the PCRW reinforced by micropiles. In addition, it also executed numerical analysis for the purpose of verifying the optimum type of reinforcement for micropiles based on the results of laboratory model tests. The optimum reinforcement type of micropiles was estimated by model test and numerical analysis. The length of micropiles is 0.4 times wall height and the diameter is 0.04 times wall length.

Comparison of quality changes in brined cabbage with deep sea water salt and a commercial brined cabbage product (해양심층수염 절임배추와 시판 절임배추의 품질변화 비교)

  • Lim, Ji Hoon;Jung, Jee Hee;Kim, Dong Soo;Kim, Young Myoung;Kim, Byoung Mok
    • Food Science and Preservation
    • /
    • v.21 no.5
    • /
    • pp.676-687
    • /
    • 2014
  • This study investigated the quality changes in cabbage brined with deep sea water salt and in a commercial brined cabbage product. The subject cabbages were separated into two groups: those manufactured in the Lab (ML) and the commercial brined cabbage product (CP). Each group had three brining treatments: with sun-dried salt (S, CS), refined salt (R, CR), and deep sea water salt (D, CD). The salinity level of the ML group was 2.1~2.3%, higher than that of the CP group (1.1~1.5%). The total plate count (TPC) was detected as 5.0 log CFU/g with the S, R, and D treatments at Day 7, but the growth rate of the TPC with the CS, CR, and CD treatments was faster than that with the S, R, and D treatments (6.9~7.7 log CFU/g). A lactic acid bacteria (LAB) level of 5.0~6.6 log CFU/g was also detected in the S, R, and D samples, but only 7.0~7.6 log CFU/g was detected in the CP groups at Day 14. The instrumental hardness levels of the cabbage brined with the deep sea water salts (D and CD) were 3,971 g and 3,932.4 g, respectively, which were significantly higher than those of the samples that were salted with sun-dried salt and refined salt (p<0.05). As for the sensory attributes, S, D, and CD maintained their marketability scores until the end of the storage period for all the properties. CD presented the highest total free amino acid (478.9 mg%), glutamic acid (107.0 mg%), citric acid (428 mg%), and sodium (189 ppm) contents.

Modeling and Intelligent Control for Activated Sludge Process (활성슬러지 공정을 위한 모델링과 지능제어의 적용)

  • Cheon, Seong-pyo;Kim, Bongchul;Kim, Sungshin;Kim, Chang-Won;Kim, Sanghyun;Woo, Hae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1905-1919
    • /
    • 2000
  • The main motivation of this research is to develop an intelligent control strategy for Activated Sludge Process (ASP). ASP is a complex and nonlinear dynamic system because of the characteristic of wastewater, the change in influent flow rate, weather conditions, and etc. The mathematical model of ASP also includes uncertainties which are ignored or not considered by process engineer or controller designer. The ASP is generally controlled by a PID controller that consists of fixed proportional, integral, and derivative gain values. The PID gains are adjusted by the expert who has much experience in the ASP. The ASP model based on $Matlab^{(R)}5.3/Simulink^{(R)}3.0$ is developed in this paper. The performance of the model is tested by IWA(International Water Association) and COST(European Cooperation in the field of Scientific and Technical Research) data that include steady-state results during 14 days. The advantage of the developed model is that the user can easily modify or change the controller by the help of the graphical user interface. The ASP model as a typical nonlinear system can be used to simulate and test the proposed controller for an educational purpose. Various control methods are applied to the ASP model and the control results are compared to apply the proposed intelligent control strategy to a real ASP. Three control methods are designed and tested: conventional PID controller, fuzzy logic control approach to modify setpoints, and fuzzy-PID control method. The proposed setpoints changer based on the fuzzy logic shows a better performance and robustness under disturbances. The objective function can be defined and included in the proposed control strategy to improve the effluent water quality and to reduce the operating cost in a real ASP.

  • PDF

Studies on the Effects of Variation Methods of Rotation Irrigation Systems Affecting on the Growth, Yield of Rice Plant and its Optimum Facilities (윤환관개의 방법의 차이가 수도생육 및 수량에 미치는 영향과 그 적정시설에 관한 연구)

  • 이창구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.2 no.5
    • /
    • pp.4-18
    • /
    • 1969
  • This experiment was conducted, making use of the "NONG-RlM 6", a recommended variety of rice for year of 1968. Main purposes of the experiment are to explore possibilities of: a) ways and means of saving irrigation water and, b) overcoming drought at the same time so that an increased yield in rice could be resulted in. Specifically, it was tried to determine the effects of the circulation irrigation method combined with differentiated thickness of lining upon the growth and yield of rice. Some of the major findings are summarized in the following. 1) The different thicknesses show a significant relationship with the weight of 1,000 grains. In the case of 9cm-lined plot, the grain weight is 23.5 grams, the heaviest. Next in order are 3cm-lined plot, 6cm-lined plot, control plot, and wheat straw lined-plot. 2) In rice yield, it is found that there is a considerably moderate significant relationship with both the different thickness of lining and the number of irrigation, as shown in the table. 3) There is little or no difference among different plots in terms of a) physical and chemical properties of solid, b) quality of irrigation water, c) climatic conditions, and rainfalls. 4) It is found that there is a significant relationship between differences in the method of rotation irrigation and the number of ears per hill. The plot irrigated at an interval of 7 days shows 17.4 ears and the plot irrigated at an interval of 6 days, 16.3. 5) In vinyl-treated plots, it is shown that both yield and component element are greatest in the case of the plot with hole of 3$cm/m^2$. Next in order are; the plot with a hole of 2$cm/m^2$; the plot with a hole of 1$cm/m^2$. In the case of the plot with no hole, it is found that both yield and component elements are decreased as compared to the control plot. 6) The irrigation water requirement is measured for the actual irrigation days of 72 which are the number subtracted the days of rainfall of 30 from the total irrigation days of 102. It is found that the irrigation water requirement for the un control plot is 1,590 mm, as compared to 876 mm (44.9% saved) for the 9cm-lined plot, 959mm(39.7% saved) for the 6cm-lined plot, 1,010mm (36% saved) for the 3cm-lined plot, and 1,082mm (32% saved) for the wheat straw lined plot. In the case of the rotation irrigation method, it is found that the water requirement for the plot irrigated at an interval of 8 days is 538mm (65.3% saved), as compared to 617mm (61.1% saved) for the plot irrigated at an interval of 7 days, 672mm (57.7% saved) for the plot irrigated at an interval of 6 days, 746mm (53.0% saved) for the plot irrigated at an interval of 5 days, 890mm (44.0% saved) for to plot irrigated at an interval of 4 days, and 975mm (38.6% saved) for the plot irrigated at an interval of 3 days. 7) The rate of evapo-transpiration is found 2.8 around the end of the month of July, as compared to 2.6 at the begining of August, 3.4 around the end of August, and 2.6 at the begining of September. 8) It is found that the saturaton quantity of 30 mm per day is decreased to 20mm per day through the use of vinyl covering. 9) The husking rate shows 75 per cent which is considered better.

  • PDF