• Title/Summary/Keyword: Quality Control of Concrete

Search Result 455, Processing Time 0.024 seconds

Quality Control Method for the Concrete from Multiple Suppliers (콘크리트 혼합타설시 품질확보 방안)

  • Kim, Kyung-Hoon;Lee, Sang-Hak
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.3
    • /
    • pp.227-234
    • /
    • 2018
  • Concrete mix design controls the various concrete properties such as workability and strength. Fresh concrete requires workability and the hardened concrete requires compressive strength. If using the concrete from different supplier concurrently, the concrete placed can show different properties unlike originally designed. However most of construction sites place the concrete from several companies. One of the predictable problems is whether the ultimate performance of concrete achieves the originally designed performance after placing the concrete from several companies. Therefore this research aims to keep the concrete quality in the above cases. This research has been done through literature review, questionnaire and the verification at the sample construction site. A literature review describes the general characteristics and quality control of concrete and a questionnaire describes the awareness and implementation of Korean Construction Specification(KCS). The production capacity and the delivery capacity of concrete suppliers is smaller than the daily quantity required on the sample site, therefore the placing of the concrete with different mixing ratio is inevitable and it can not keep the KCS. As a conclusion, this research proposed 5 alternatives and one of them has been adopted, i.e. to unify the concrete mix design of multiple concrete suppliers.

Neuro-fuzzy based approach for estimation of concrete compressive strength

  • Xue, Xinhua;Zhou, Hongwei
    • Computers and Concrete
    • /
    • v.21 no.6
    • /
    • pp.697-703
    • /
    • 2018
  • Compressive strength is one of the most important engineering properties of concrete, and testing of the compressive strength of concrete specimens is often costly and time consuming. In order to provide the time for concrete form removal, re-shoring to slab, project scheduling and quality control, it is necessary to predict the concrete strength based upon the early strength data. However, concrete compressive strength is affected by many factors, such as quality of raw materials, water cement ratio, ratio of fine aggregate to coarse aggregate, age of concrete, compaction of concrete, temperature, relative humidity and curing of concrete. The concrete compressive strength is a quite nonlinear function that changes depend on the materials used in the concrete and the time. This paper presents an adaptive neuro-fuzzy inference system (ANFIS) for the prediction of concrete compressive strength. The training of fuzzy system was performed by a hybrid method of gradient descent method and least squares algorithm, and the subtractive clustering algorithm (SCA) was utilized for optimizing the number of fuzzy rules. Experimental data on concrete compressive strength in the literature were used to validate and evaluate the performance of the proposed ANFIS model. Further, predictions from three models (the back propagation neural network model, the statistics model, and the ANFIS model) were compared with the experimental data. The results show that the proposed ANFIS model is a feasible, efficient, and accurate tool for predicting the concrete compressive strength.

A Study on Quality Control of Waterproof Agent and Admixture of Cement for Concrete Surface Treatment (콘크리트 표면처리용 시멘트 액체방수제의 품질관리에 관한 연구)

  • 최은수;곽규성;배기선;오상근;안상덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.181-188
    • /
    • 2000
  • This study deals with the method of test for waterproof agent and admixture of cement, and especially, the effect in bond strength between waterproofing layer and mortar of concrete substrate in building construction. The purpose of this study is that it makes the estimation value of bond strength of concrete wall and anticorrosive when coated waterproof agent and admixture of cement as waterproofing materials for durability performance estimation depend on concrete watertighness.

  • PDF

A Study on the Properties of Ready Mixed Concrete Quality in Site by Statistical Analysis (통계분석에 의한 현장 타설 콘크리트의 품질 특성에 관한 연구)

  • Ji, Suk-Won;Jung, Si-Jin;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.171-180
    • /
    • 2007
  • The quality of ready-mixed concrete(henceforth abbreviated remicon) is influenced by various factors such as ingredient of material, difference of property, mixing ratio, mixing time, mixing error, conditioning of construction, method of curing and temperature, humidity time in transportation. These factors make it hard to confirm the quality of remicon till placing in site. As the quality control in field is very important to ensure the quality of building. Moreover in modern building production, the more important the inquiry of performance improvement, the more important the manufacture and the quality control of remicon. In this study, to examine and analyze the quality of remicon we used slump, air content and compressive strength in 7, 28 days as to remicon which placed during on year. As a result, we found that the slump and air content were satisfied with reference code and the compressive strength was more than the design standard strength so we concluded that the quality control of remicon was to be agreeable.

Influence of Micro-Structural Characteristics of Concrete on Electrical Resistivity (콘크리트의 미세구조 특성이 전기저항에 미치는 영향)

  • Yoon, In-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.122-129
    • /
    • 2013
  • Since electrical resistivity of concrete can be measured in a more rapid and simple way than chloride diffusivity, it should be primarily regular quality control of the electrical resistivity of concrete which provides the basis for indirect of quality control of chloride diffusivity during concrete construction. If this is realized, the electrical resistivity of concrete can be a crucial parameter to establish maintenance strategy for marine concrete structures. The purpose of this study is to develop, design and test a surface electrical resistivity measurement protocol. Microstructural affecting factors such as capillary water, porosity, tourtousity, and so on, on the electrical resistivity of concrete were examined taking into account for mixing proportion properties, and hydration stage. This study can provide a non-destructive approach for durability design of marine concrete. From the relationship between electrical resistivity and chloride diffusivity, it is expected that the result is subsequently used as a calibration curve for an indirect control of the chloride diffusivity based on regular measurements of the electrical resistivity during concrete construction.

A Study Using Rebound Method and Impact Echo Method for the Comparison of the Compressive Strength of Concrete Slab (반발 경도법 및 충격반향기법을 이용한 콘크리트 슬래브의 압축강도 비교에 관한 연구)

  • Hong, Seong-Uk;Cho, Young-Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.3
    • /
    • pp.199-207
    • /
    • 2008
  • As infrastructures are being deteriorated, nondestructive evaluation of existing structures and construction quality control are increasingly demanded. The importance of predicting compressive strength of concrete structure is also gradually increasing in construction industry. The estimation of concrete compressive strength is a critical factor of the construction management and quality control. This study has been conducted using Schmidt hammer test and Impact echo method, which are nondestructive test methods for the comparison of the concrete compressive strength. It is focusing to examine the relationship between compressive strength of concrete and rebound number by Schmidt hammer test result by Impact echo method. It was found that concrete compressive strength and rebound number have a close correlation.

An Experimental Study on the Application of Measuring Method of Water Content for Quality Control of Concrete (콘크리트 품질관리를 위한 단위수량 측정 기법의 적용성에 관한 실험적 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Lee, Do-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2007
  • Recently, the concern on the receipt of poor ready-mixed concrete in the construction field and the durability of concrete has been increased. Based on the such background, a large number of measuring methods of water content for fresh concrete have been developed and enforced in a developed country. In this study, to investigate practicality for quality control of ready-mixed concrete among various water content measurement techniques, microwave range method, air meter method and capacitance measurement method as measuring methods of water content were selected. Then, it was evaluated estimating performance of water content according to the change of binder types, fine aggregate types, absorption ratio, water content and water-binder ratio in series I and II. Also, it was examined influence on error occurrence of water content according to change of properties of used materials in series III. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of water content to quality control of ready-mixed concrete in construction field.

Comparison of Void Content between Cyldrical Concrete Specimen and Concrete Core Specimen Using ASTM C 642 Test Procedure (ASTM C 642 시험방법을 이용한 구조체 코어공시체와 원주형 공시체의 공극률 비교 평가)

  • Son, Joeng Jin;Kim, Ji-Hyun;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.631-640
    • /
    • 2022
  • Recently, construction accidents have occurred due to illegal water addition and insufficient quality control at domestic construction sites. In this study, the void content test method proposed in ASTM C 642 was used to provide a reference guideline for evaluation on the quality control status of cast-in-place structural concrete. For this purpose, simulated structural concrete for coring purpose was prepared in addition to the concrete cylindrical specimens with the same formulation, and the changes in compressive strength, elastic modulus, and void content related to coring were evaluated. According to experimental results, the compressive strength and modulus of elasticity were reduced by coring, which was associated with the generation of microcracks during coring. With respect to void content, the difference in void content between the cylindrical specimen and the cored specimen was up to 1.69%. If this value is used as a correction factor, it is possible to estimate the real void content of the cast-in-place structural concrete. By comparing this with the void content obtained from cylindrical concrete specimens, it is possible to evaluate the quality control status and amount of illegal water addition on the structural concrete.