• Title/Summary/Keyword: Quality Control Checklist

Search Result 31, Processing Time 0.029 seconds

A Study on Improving Concrete Quality Control using Customized Checklist (맞춤식 체크리스트를 응용한 콘크리트 품질관리 개선방안)

  • Park Sangmin;Kim Changduk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-62
    • /
    • 2000
  • A concrete element is obtained through multi-steps, and its quality is affected by site conditions and control constituents of procedures. In these regards, in order to assure designed qualities of concrete and associated materials of the element good quality control method is necessary in various procedures. The existing quality control measures do not satisfy the requirements for the quality control activities at each production step. This study provides a more effective checklist for each phase of concrete work, which improves existing quality control checklist through extensive research on current practices and surveys from expertises. This paper also proposes the application of multi-facet codes to develop a customized checklist to improve the efficiency in field practices and the effectiveness in assuring the designed performance of concrete. This study finally provides a more effective checklist for each phase of concrete work by improving usability of the developed project sensitive matric quality control checklist through application experiments on construction project sites.

  • PDF

Improvement of HACCP Verification Checklist in School Foodservices - A Case Study on Cooked Squid with Seasoned Fresh Vegetable - (학교급식 HACCP 검증 체크리스트 개선 - 오징어채소무침을 중심으로 -)

  • Kim, Yang-Sook;Moon, Hye-Kyung;Jeong, Hye-Jin
    • Journal of the Korean Dietetic Association
    • /
    • v.18 no.3
    • /
    • pp.222-233
    • /
    • 2012
  • The purpose of this study was the improvement and modification of the HACCP verification checklist in school foodservices. For this, the HACCP verification checklist was modified on the basis of an existing school foodservice format. The modified checklist was composed of 28 items, including CCPs (critical control points), microbial test, and other components of the HACCP system than CCPs. To confirm the suitability of the modified checklist, comparisons were made based on the microbiological quality of cooked foods, utensils, and number of aerial microbes in the working area. In this study, the applicability of the modified checklist was determined by focusing on cooked squid with seasoned fresh vegetables (Ojingeochaesomoochim). The following results were obtained from 14 schools in Changwon. The checklist scores for maintaining hot foods over $60^{\circ}C$ or serving within 2 hours, microbial tests of drinking water, food contact surfaces and cooking utensils, monitoring tools, and usage of suitable sanitizers were 2 points each (The possible highest score is 2 points). On the contrary, the checklist score for microbial test of cooked foods was the lowest of all the items. The correlation coefficient (r) between the improved checklist and microbiological quality of cooked foods was 0.699 (P<0.01), whereas that between the improved checklist and microbiological quality of cooking utensils was 0.612 (P<0.05). The correlation coefficient between the improved checklist and aerial plate count in the working area was -0.556 (P<0.05). Our results indicate the potential possibility of using the HACCP verification checklist in school foodservices.

Improvement Plan of Quality Control for 3D Geospatial Database (3차원 국토공간정보 품질관리 개선방안에 관한 연구)

  • Seo, Chang-Wan;Choi, Yun-Soo;Kim, Jae-Myeong;Kim, Young-Hak;Kim, Young-Gil
    • Spatial Information Research
    • /
    • v.17 no.2
    • /
    • pp.231-241
    • /
    • 2009
  • Recently, The importance of a quality control for implementing 3D geospatial database has being emphasized to build a 21st century knowledge society and an ubiquitous land. The improvement of 3D geospatial database quality control through establishing an integrated quality control makes data suppliers update data efficiently and users get high quality data. The purpose of this study was to derive the improvement plan of 3D geospatial database quality control through the analyses of the existing 3D geospatial database quality control and case studies. The results of this study are as follows. Firstly, we defined the concept of 3D geospatial database quality control. Secondly, we set the boundary, factors and process of 3D geospatial database quality control through classifying it in detail. Lastly, we drew improvement contents such as the quality control checklist by implementation process according to the improvement plan of 3D geospatial database implementation.

  • PDF

A review of ATP Onboard System's Test procedure (열차방호장치(ATP) 차상설비 시험절차에 대한 고찰)

  • Chang, Seok-Gahk;Kim, Jin-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1163-1168
    • /
    • 2008
  • Automatic Train Protection(ATP) System is developed by ETCS(European Train Control System) CONSORTIUM for unify Europe railway system. ATP system is composed of Eurobalise and EuroATC. Nowadays, Korea construct ATP system in conventional line and new electrical locomotives also install ATP system. It is important to verify quality which form checklist during Factory Acceptance Test at beyond the seas. In this paper, review the process, test item, norm and checklist for the Balise Transmission Module, Compact Antenna Unit, Vehicle Control Unit and Communication Controller at the Plymouth Bombardier and Vasteras enics factory.

  • PDF

Checklist and Design Recommendations for the Interiors of Korean, Eco-healthy Childcare Facilities (우리나라 영유아 보육시설의 친환경 실내를 위한 체크리스트와 디자인안 제안)

  • Chun, Jin Hie
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.105-114
    • /
    • 2010
  • As children are known to touch and chew everything, green cleaning procedures are an important step in preventing children from ingesting harmful toxins. The objectives of this study are to develop a new, self-evaluation checklist and to suggest design recommendations which comply with easy, adaptable, economical ways to improve the eco-friendly indoor environment of Korean childcare facilities. The information compiled during this study was collected through literature review and internet surveys1) from July, 2009 to February, 2010. The results of this study show that the current Korean childcare accreditation system and practices emphasize clean building interiors, policies for sanitation and cleanliness, and control of humidity and lighting. On the other hand, the information provided by green-building rating systems from GBCC, LEED, and GBTool offers additional and comparative details regarding indoor environment quality and standards regarding the IAQ performance and management plan, ventilation and thermal comfort systems, views from windows, acoustics, and lighting. In conclusion, this document provides an appropriate and easy-to-follow, self-evaluation checklist composed of eight criteria and 51 practical items. This study also provides the design recommendations composed of 27 practical ideas focusing on interior elements. Both the checklist and design recommendations I have suggested can be a post-occupancy tool for evaluating eco-healthy facility standards as well as tips for continuing to maintain eco-healthy childcare facilities.

Quality Improvement in the Trauma Intensive Care Unit Using a Rounding Checklist: The Implementation Results

  • Chang, Ye Rim;Chang, Sung Wook;Kim, Dong Hun;Yun, Jeongseok;Yun, Jung Ho;Lee, Seok Won;Jo, Han Cheol;Choi, Seok Ho
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.113-119
    • /
    • 2017
  • Purpose: Despite the numerous protocols and evidence-based guidelines that have been published, application of the therapeutics to eligible patients is limited in clinical settings. Therefore, a rounding checklist was developed to reduce errors of omission and the implementation results were evaluated. Methods: A checklist consisting of 12 components (feeding, analgesia, sedation, thromboembolic prophylaxis, head elevation, stress ulcer prevention, glucose control, pressure sore prevention, removal of catheter, endotracheal tube and respiration, delirium monitoring, and infection control) was recorded by assigned nurses and then scored by the staff for traumatized, critically ill patients who were admitted in the trauma intensive care unit (ICU) of Dankook University Hospital for more than 2 days. A total of 170 patients (950 sheets) between April and October 2016 were divided into 3 periods (period 1, April to June; period 2, July to August; and period 3, September to October) for the analysis. Questionnaires regarding the satisfaction of the nurses were conducted twice during this implementation period. Results: Record omission rates decreased across periods 1, 2, and 3 (19.9%, 12.7%, and 4.2%, respectively). The overall clinical application rate of the checklist increased from 90.1% in period 1 to 93.8% in period 3. Among 776 (81.7%) scored sheets, the rates of full compliance were 30.2%, 46.2%, and 45.1% for periods 1, 2, and 3, respectively. The overall mean score of the questionnaire regarding satisfaction also increased from 61.7 to 67.6 points out of 100 points from period 1 to 3. Conclusions: An ICU rounding checklist could be an effective tool for minimizing the omission of preventative measures and evidence-based therapy for traumatized, critically-ill patients without overburdening nurses. The clinical outcomes of the ICU checklist will be evaluated and reported at an early date.

Quality Assessment Tools and Reporting Standards in Nursing Research (간호연구 질 평가 도구 및 보고지침 고찰)

  • Kim, Kyunghee;Kim, Joo Hyun;Lim, Kyung-Choon;Lee, Kyung-Sook;Jeong, Jae-Sim;Choe, Myoung-Ae;Chae, Young Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.3
    • /
    • pp.221-230
    • /
    • 2012
  • Purpose: Quality of nursing research should be evaluated before it is applied as an evidence for evidence-based nursing practice. This study attempted to analyze and to compare tools for the quality assessment and reporting standards of nursing research using CONSORT and STROBE checklist by types of research design. Methods: We searched the tools for quality assessment in nursing research based on the National Evidence-based Healthcare Collaborating Agency (NECA) publication. Then, we analysed and compared the tools for quality evaluation by types of research design. Results: According to the analysis using CONSORT checklist, ROB shows coherence in 17 items, Jadad shows coherence in 3 items, SIGN (for RCT) shows coherence in 26 items, and Downs & Black shows coherence in 24 items. According to the analysis using STROBE checklist, MINORS shows coherence in 25 items, NOS shows coherence in 21 items, SIGN (for Cohort studies & Case-control studies) shows coherence in 29 items, and RoBANS shows coherence in 21 items. Conclusion: Based on our analysis, we recommend that nursing researchers should report according to the reporting standards of tools for quality evaluation. We hope that our analysis can be helpful to develop evidence-based nursing.

Improvement of the Checklist for Residential Housing's Crime Prevention Accreditation Assessment (주거시설에 대한 CPTED 평가인증 기준 개선방안 연구)

  • Park, Hyeon-Ho;Kim, Kang-Il;Cho, Joon-Tag
    • Korean Security Journal
    • /
    • no.55
    • /
    • pp.117-141
    • /
    • 2018
  • Police crime statistics report that residential housing such as apartment, low rise, detached houses is the second most vulnerable to crime, which is closely followed by the number of street crimes. Also residential houses are often exposed to quality-of-life crime, e.g burglary. It threatens the basic human rights of house residents in terms of safety and comfort within the urban living environment. This study examines related precedent studies regarding the vulnerability of residential housing including studios, multi-family housing from the viewpoint of crime prevention through environment design(CPTED), extracted the elements and items suitable for the safety of residential facilities and the certification evaluation indicators and check items to be the basis for the checklist are derived. Based on these evaluation indicators and inspection items, we conducted on-site surveys of residential facilities in three areas of Seoul, Yongin and Asan, and the final draft of the checklist was revised based on the results of the field survey. There are 43 items on the 7 fields of evaluation in the final version of checklist, 11 items in the management and operation, 20 items in the surveillance, 7 items in the access control, 1 item in the territoriality, 2 items in the activity support, and 2 items in the security and safety facilities. In addition, various points of interest were added to allow the administrator of the residential facility to earn points for special measures taken for safety. This checklist can be appropriately modified and utilized in consideration of the characteristics of each facility. Korean national police agency has CPOs to check the residential facilities in their jurisdiction using checklists and to certify excellent facilities with high level of safety.

Effects of Tai Chi Self-help Program on Glucose Control, Cardiovascular Risks, and Quality of Life in Type II Diabetic Patients (제 2유형 당뇨환자를 위한 타이치 자조프로그램이 혈당조절, 심혈관 위험효소, 삶의 질에 미치는 효과)

  • Song, Rha-Yun;Lee, Eun-Ok;Bae, Sang-Cheol;Ahn, You-Hern;Lam, Paul;Lee, In-Ok
    • Journal of muscle and joint health
    • /
    • v.14 no.1
    • /
    • pp.13-25
    • /
    • 2007
  • Purpose: The purpose of the study was to identify the effects of Tai Chi self-help program on glucose control, cardiovascular risks, and quality of life in patients with type II diabetes. Method: The study subjects were 95 adults with type II diabetes recruited from five primary health centers and one outpatient clinic. The Tai chi self-help program was provided twice a week for 6 months. Outcome measures included blood glucose(HbA1c), cardiovascular risk checklist, and quality of life(SF36). Result: At the completion of 6-month program, HbA1c for Tai Chi group dropped from 6.79 to 6.59 without significant group differences. However, cardiovascular risk scores for Tai Chi group has been significantly reduced compared to the control group. In 6 months, quality of life (SF36) was significantly better for Tai Chi group especially in the areas of physical and social functioning. Conclusion: Tai Chi self-help program applied for type 2 diabetes patients has been partially effective to control cardiovascular risk factors, and some dimensions of quality of life. Tai Chi self-help program can be safely and easily applicable to primary care centers for diabetic patients and other people with chronic disease for their symptom management, and health promotion.

  • PDF

Quality Control Program and Its Results of Korean Society for Cytopathologists (대한세포병리학회 정도관리 현황 및 결과)

  • Lee, Hye-Kyung;Kim, Sung-Nam;Khang, Shin-Kwang;Kang, Chang-Suk;Yoon, Hye-Kyoung
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.2
    • /
    • pp.65-71
    • /
    • 2008
  • In Korea, the quality control(QC) program forcytopathology was introduced in 1995. The program consists of a checklist for the cytolopathology departments, analysis data on all the participating institutions' QC data, including the annual data on cytologic examinations, the distribution of the gynecological cytologic diagnoses, as based on The Bethesda System 2001, and the data on cytologic-histolgical correlation of the gynecological field, and an evaluation for diagnostic accuracy. The diagnostic accuracy program has been performed 3 times per year with using gynecological, body fluid and fine needle aspiration cytologic slides. We report here on the institutional QC data and the evaluation for diagnostic accuracy since 2004, and also on the new strategy for quality control and assurance in the cytologic field. The diagnostic accuracy results of both the participating institutions and the QC committee were as follows; Category 0 and A: about 94%, Category B: 4-5%, Category C: less than 2%. As a whole, the cytologic daignostic accuracy is relatively satisfactory. In 2008, on site evaluation for pathology and cytology laboratories, as based on the "Quality Assurance Program for Pathology Services" is now going on, and a new method using virtual slides or image files for determining the diagnostic accuracy will be performed in November 2008.