• Title/Summary/Keyword: Quality Control (QC)

Search Result 179, Processing Time 0.029 seconds

A comparative study for reconstructing a high-quality NDVI time series data derived from MODIS surface reflectance (MODIS 지표 분광반사도 자료를 이용한 고품질 NDVI 시계열 자료 생성의 기법 비교 연구)

  • Lee, Jihye;Kang, Sinkyu;Jang, Keunchang;Hong, Suk Young
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.149-160
    • /
    • 2015
  • A comparative study was conducted for alternative consecutive procedures of detection of cloud-contaminated pixels and gap-filling and smoothing of time-series data to produce high-quality gapless satellite vegetation index (i.e. Normalized Difference Vegetation Index, NDVI). Performances of five alternative methods for detecting cloud contaminations were tested with ground-observed cloudiness data. The data gap was filled with a simple linear interpolation and then, it was applied two alternative smoothing methods (i.e. Savitzky-Golay and Wavelet transform). Moderate resolution imaging spectroradiometer (MODIS) data were used in this study. Among the alternative cloud detection methods, a criterion of MODIS Band 3 reflectance over 10% showed best accuracy with an agreement rate of 85%, which was followed by criteria of MODIS Quality assessment (82%) and Band 3 reflectance over 20% (81%), respectively. In smoothing process, the Savitzky-Golay filter was better performed to retain original NDVI patterns than the wavelet transform. This study demonstrated an operational framework of gapdetection, filling, and smoothing to produce high-quality satellite vegetation index.

Charaeteristics and Applications of the Established Testosterone Immunoassays (Testosterone 면역측정법의 정립 특성과 응용)

  • Lee, Chang-Joo;Lee, Joon-Yeoung;Yoon, Yong-Dal
    • Development and Reproduction
    • /
    • v.5 no.1
    • /
    • pp.59-71
    • /
    • 2001
  • Since the first radioimmunoassay (RIA) was developed in 1970s, many conventional RIAs and non-isotopic immunoassays (NIA) had been developed in which the degree of precision, accuracy, specificity and practicability have progressively increased. Recently ultrasensitive assay method at femtogram to determine testosterone in serum, saliva and feces is required for the study of sexual dysfunctions in male and female, monitoring the psychological stress and conditions, aging process such as menopause and partial androgen deficiency in aging male, the hormonal changes of small experimental animals etc. This review discussed the recentd evelopments of steroid assay methods, based upon the testosterone assay results of authors far 20 years, and the problems associated the assay set-up, the characterizations and applications of the established procedures, and desifls of assay, reliablity criteria, and the practical aspects of assay set-up and application, based upon the data of the authors. The present study demonstrates the general problems methods to be consider in order to set up the highly sensitive assay methods and to increase the assay quality and the necessity of assay quality control program. To improve the assay quality of each laboratory and to compare the assay results in homeland, the national QC programs should be organized.

  • PDF

A study on the Effectivness of Hand-made Paraffin Thyroid Phantom (Paraffin을 이용한 Thyroid Phantom제작에 따른 유용성에 관한 연구)

  • Park, Soung-Ock;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.237-243
    • /
    • 2007
  • Phantoms are very necessary for quality assurance of radio nuclides imaging systems to maintain standards and to ensure reproducibility of test. General quality assurance and instrument quality control are essential in every hospital. The human tissue equivalent materials are aluminum, areryl, water and epoxy..etc. It is very important to select optimum equivalant materials for a phantoms in QC. Especially, paraffin is very similar with human soft tissue in X or Gamma-ray physical characteristics and easy to buy with economically. We made a paraffin thyroid phantom and compare with thyroid areryl phantom, also used commercially in practice. Two small size cold spots(3 and 6 mm diameter) and a hot spot(3 mm diameter) embeded in paraffin phantom. And imaged with $^{99m}TcO_4$ by camera for analysis about spatial resolution and noise at the hot and cold spots. We got some results as below : 1. No difference in counting rate and noise between both arcryl and paraffin thyroid phantoms. 2. The best spatial resolution can be seen 6 cm distance between pinhole collimator and thyroid phantoms(arcryl and paraffin). 3. More optimal spatial resolution could acquired in paraffin thyroid phantom. Paraffin is very similar with human soft tissue in atomic number, density and relative absorbtion function, and can be shaped easily what we wanted. So we can recommendation paraffin as quality assurance phantom because its usefulness, economical benefit and purchasability.

  • PDF

Quantitative Study of CO2 based on Satellite Image for Carbon Budget on Flux Tower Watersheds (플럭스 타워 설치 유역을 대상으로 탄소수지 분석을 위한 위성영상자료기반의 CO2 정량화 연구)

  • Jung, Chung Gil;Lee, Yong Gwan;Kim, Seong Joon;Jang, Cheol Hee
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.3
    • /
    • pp.109-120
    • /
    • 2015
  • Spatial heterogeneous characteristics of solar radiation energy from Climate Change gives rise to energy imbalance in the general ecological system including water resources. This study is to estimate the $CO_2$ flux of South Korea using Terra MODIS image and to assess the reliability of MODIS data from the ground measured $CO_2$ flux by eddy covariance flux tower data at 3 locations (two at mixed forest area and one at rice paddy area). The MODIS Gross Primary Productivity (GPP) product (MOD17A2), 8-day composite at 1-km spatial resolution was adopted for the spatial $CO_2$ flux generation. The MOD17A2 data by noise like cloud and snow in a day were tried to fill by Inverse Distance Weighted (IDW) method from valid pixels and the damping effect of MOD17A2 data were corrected by Quality Control (QC) flag. The MODIS $CO_2$ flux was estimated as the sum of GPP and Re (ecosystem respiration) by Lloyd and Taylor method (1994). The determination coefficient ($R^2$) between MODIS $CO_2$ and flux tower $CO_2$ for 3 years (2011~2013) showed 0.55 and 0.60 in 2 mixed forests and 0.56 in rice paddy respectively. The $CO_2$ flux generally fluctuated showing minus values during summer rainy season (from July to August) and maintaining plus values for other periods. The MODIS $CO_2$ flux can be a useful information for extensive area, for example, as a reliable indicator on ecological circulation system.

Distribution of Airborne Hexavalent Chromium Concentrations in Large Industrial Complexes in Korea

  • Kang, Byung-Wook;Lee, Hak-Sung;Kim, Jong-Ho;Hong, Ji-Hyung;Kim, Rok-Ho;Seo, Young-Kyo;Han, Jin-Seok;Baek, Kyung-Min;Kim, Min-Ji;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.208-216
    • /
    • 2016
  • This paper reports the results of a field evaluation which used sampling and analytical methods to determine the levels of airborne hexavalent chromium Cr(VI) in major industrial complexes in Korea over a seven year period (2007-2013). Cr(VI) concentrations were determined using cellulose filter sampling and ion chromatography analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control (QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of Cr(VI) for the nine industrial complexes in Korea were in the range of 0.09 to $1.40ng/m^3$, which is similar to of the concentrations in other industrial areas around the world. The impacts of Cr(VI) emissions from industrial areas on Cr(VI) concentrations in neighboring-residential areas were considerably low, and the dispersion of Cr(VI) from industrial areas to residential areas was estimated to be 'not-significant'. Cr(VI) levels were not affected by seasonal variation, which suggests that chromium was emitted continuously from the industrial sources throughout the year. The concentration of Cr(VI) measured accounted for 0.7 to 9.4 percent of the total chromium level, which is a low percentage compared to those in other urban areas around the world. This is the first report in an international journal of a field study conducted in Korea to determine the concentration of Cr(VI) in the ambient air of industrial and residential areas.

Experimental studies of validation and stability of Sweet Bee Venom using HPLC (Sweet BV의 조제물 농도분석 및 안정성 확인을 위한 시험적 연구)

  • Kang, Kye-Sung;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.12 no.4
    • /
    • pp.33-50
    • /
    • 2009
  • Objectives : This study was conducted to confirm validation and stability of concentration analysis method of pure melittin (Sweet Bee Venom-Sweet BV) extracted from the bee venom by utilizing protein isolation method of gel filtration. Methods : All experiments were conducted at Biotoxtech, a non-clinical studies authorized institution, under the regulations of Good Laboratory Practice (GLP). Standard solutions of melittin (SIGMA, USA) and test substances were dispensed and were analyzed with HPLC for Sweet BV to secure the validation of analysis. Results : 1. Measurement of system suitability of Sweet BV satisfied criterion of below 3%. 2. Confirming Linearity of Sweet BV in 10-200${\mu}g/m\ell$ solution yielded correlation coefficient (r) of 0.995 and accuracy of 85-115% which satisfy criterion. 3. Measurement of Specificity of Sweet BV didn't yield any substance affecting the peak of test substances, but detected at 21.22min verified as the test substance. 4. Confirming Intra-day of Sweet BV, accuracy and precision of 0.1, 100${\mu}g/m\ell$ were 105.70, 95.81 and 0.66, 0.73, respectively, satisfying both criteria of accuracy (85-115%) and precision (within 10%). 5. To measure Stability in autosampler, all samples used in Intra-day reproducibility sat in the autosampler for five hours and were re-analyzed. Both variability and precision satisfied the criteria. 6. Homogeneity of Sweet BV (0.1, 100${\mu}g/m\ell$) at upper, middle, and lower layers all satisfied the accuracy and precision criteria. 7. Stability of Sweet BV (0.1, 100${\mu}g/m\ell$) at room temperature for four hours and refrigerated for 7 days all satisfied the criterion. 8. For the measurement of Quality control, QC samples measured on the first and eighth day all satisfied accuracy and precision criteria. Conclusion : Above experiment data satisfies validation and stability of concentration analysis method of Sweet BV.

Simultaneous Determination of Doxifluridine and 5-FU in Liver and Intestine Tissue Using LC/MS/MS (LC/MS/MS를 이용한 원숭이 및 비글견의 간 및 장관 조직에서의 Doxifluridine과 대사체 5-FU 동시분석법 개발)

  • Woo, Young-Ah;Kim, Ghee-Hwan;Jeong, Eun-Ju;Kim, Choong-Yong
    • YAKHAK HOEJI
    • /
    • v.52 no.2
    • /
    • pp.93-100
    • /
    • 2008
  • A liquid chromatographic method with tandom spectrometric detection (LC/MS/MS) for the simultaneous determination of doxifluridine and its active metabolite, 5-fluorouracil (5-FU) was developed over the concentration range of $5{\sim}2000$ ng/ml, respectively. Doxifluridine, 5-FU and internal standard, 5-chlorouracil (5-CU), were extracted from liver and intestine tissue via protein precipitation. Acetonitrile was used as the extraction solvent and the supernatant was evaporated and reconstructed in mobile phase. Optimum chromatographic separation was achieved on a Agilent Zorbax $C_{18}$ ($100\;mm{\times}2.1\;mm$, $3.5\;{\mu}m$) column with mobile phase run in isocratic with methanol : water (20 : 80, v/v). The flow rate was 0.2 ml/min with total cycle time of 5 min. The lower limit of quantification was validated at 5.0 ng/ml of liver and intestine tissue, for both doxifluridine and 5-FU, respectively. The intra-day and inter-day precision and accuracy of quality control (QC) samples were <11% coefficient of variation and <7% relative error from theoretical concentration for both analytes. In addition, the special designed stability study was performed, because the metabolism of doxifluridine occurs spontaneously even in ice bath for monkey liver. The stability of doxifluridine in liver and intestine of monkey and beagle dog was compared. It was found that bioanalytical validation could not be performed for the monkey liver; however, beagle dog's liver has relatively low speed of metabolism compared to monkey liver and instead of monkey liver, beagle dog's liver could be used for the validation. Bioanalytical validation could be performed in monkey intestine. Eventually, this developed method for liver and intestine will be useful in support of the toxicokinetic and pharmacokinetic studies of doxifluridine and 5-FU.

Development of a Water Information Data Platform for Integrated Water Resources Management in Seoul (서울시 통합물관리를 위한 물정보 데이터 플랫폼 구축방안)

  • Yoon, Sun Kwon;Choi, Hyeonseok;Cho, Jaepil;Jang, Suk Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.76-76
    • /
    • 2020
  • 국가 물관리일원화 이후, 지방하천 관리에 대한 지자체 역할과 권한이 커지고 있으며, 중앙정부의 물관리 수준에 부합하는 데이터관리 체계구축 및 지속적인 품질관리(Quality Control, QC)와 표준화(Standardization) 기술개발이 요구되고 있다. 지자체의 경우 기존의 행정구역별로 분산 관리해오던 물관리 시스템을 유역단위로 전환할 필요가 있으며, 국가하천 구간과 연계한 종합적인 관리가 필요한 실정이다. 서울시의 물관리 시스템은 자치구별로 산재해 있으며, 관리 주체 및 해당 변수에 따라 제공되는 정보가 다르고 하천유역 단위로 분류되어 있지 않다. 따라서, 서울시와 자치구, 중앙정부 및 관련 기관과의 연계성 있는 정보제공을 위한 데이터 플랫폼 구축 기술개발이 필요한 실정이다. 본 연구에서는, 빅데이터, AI 기술을 활용한 물정보의 품질관리 자동화 기술개발과 지속적인 유지관리 및 표준화 정보제공 시스템 구축 기능을 포함하는 서울시 통합물관리 데이터 플랫폼 구축 목표 모델을 제시하였으며, 서울시 물관리 체계와 관련하여 SWAT 분석을 통한 단계별 사업추진 로드맵을 도출하였다. 분석결과, 서울시 통합물관리 플랫폼 구축을 위해서는 유역별 수량-수질 통합 모니터링 및 모델링 기술개발, 빅데이터 기반 물 정보화 플랫폼 구축 기술개발, 지방하천 유역 거버넌스 구축 및 법제도 정비 방안 마련이 요구되며, 관련하여 주요 이슈(3대 핵심전략, 10개 단위과제)를 도출하여 관련 연구과제를 제안하였다. 마지막으로, 서울시 통합물관리 정책 실현을 위해서는 법제도 마련이 시급하며, 서울시 '통합물관리 기본조례' 제정을 통한 기반을 조성할 필요가 있음을 시사하였다. 또한, 다양한 분야 이해관계자 협의체인 '서울시 통합물관리위원회(가칭)'의 거버넌스를 구성하여 운영하는 것이 현실적이며, 한강유역관리 및 지방하천 관리와 관련한 중추적인 역할 수행과 쟁점 논의 등 합리적 합의가 가능할 것으로 기대한다.

  • PDF

Current Status and Future Direction of the NIMS/KMA Argo Program (국립기상과학원 Argo 사업의 현황 및 추진 방향)

  • Baek-Jo Kim;Hyeong-Jun Jo;KiRyong Kang;Chul-Kyu Lee
    • Atmosphere
    • /
    • v.33 no.5
    • /
    • pp.561-570
    • /
    • 2023
  • In order to improve the predictability of marine high-impacts weather such as typhoon and high waves, the marine observation network is an essential because it could be rapidly changed by strong air-sea interaction. In this regard, the National Institute of Meteorological Sciences, Korea Meteorological Administration (NIMS/KMA) has promoted the Argo float observation program since 2001 to participate in the International Argo program. In this study, current status and future direction of the NIMS/KMA Argo program are presented through the internal meeting and external expert forum. To date, a total of 264 Argo floats have been deployed into the offshore around the Korean Peninsula and the Northwestern Pacific Ocean. The real-time and delayed modes quality control (QC) system of Argo data was developed, and an official regional data assembling center (call-sign 'KM') was run. In 2002, the Argo homepage was established for the systematic management and dissemination of Argo data for domestic and international users. The future goal of the NIMS/KMA Argo program is to improve response to the marine high-impacts weather through a marine environment monitoring and observing system. The promotion strategy for this is divided into four areas: strengthening policy communication, developing observation strategies, promoting utilization research, and activating international cooperation.

Analysis of vitamin B12 in fresh cuts of Korean pork for update of national standard food composition table (국가표준식품성분표 개정을 위한 국내산 돈육의 부위별 비타민 B12 함량 분석)

  • Mun, Geum-Ju;Song, Wonju;Park, Sun-Hye;Jeong, Beom-Gyun;Jung, Gil-Rak;Choi, Kap Seong;Kim, Jin-Hyoung;Choi, Youngmin;Chun, Jiyeon
    • Food Science and Preservation
    • /
    • v.24 no.7
    • /
    • pp.983-991
    • /
    • 2017
  • This study was performed to update the National Standard Food Composition Table (NSFCT) published by Korea Rural Development Administration, especially focusing on vitamin $B_{12}$ for Korean pork. Total 7 primal and 22 retail fresh cuts of Korean pork were analyzed for vitamin $B_{12}$ and the applied immunoaffinity-HPLC was validated. Vitamin $B_{12}$ assay by immunoaffinity-HPLC obtained recoveries over 95% and coefficient variations of precision below about 10%, which met the limits required for validation acceptance. Limits of detection and quantification of immunoaffinity-HPLC were 0.01 and $0.33{\mu}g/100g$, respectively. Quality control chart showed that analysis performance was excellent during the entire of study. Vitamin $B_{12}$ contents of pork cuts significantly varied depending the types of primal and its retail cuts (p<0.05). Belly, Boston butt, rib cuts showed relatively high vitamin $B_{12}$ contents compared to other primal cuts. Vitamin $B_{12}$ content of pork retail cuts were also significantly different within the same primal cuts (p<0.05). Among 22 retail cuts, the highest vitamin $B_{12}$ was observed in Tosisal in belly primal part ($0.98{\mu}g/100g$) while both Aldeungsimsal in loin and Hongdukkaesal in hide leg were the lowest by $0.33{\mu}g/100g$. This study provides reliable vitamin $B_{12}$ data for the Korean pork fresh cuts through standard sampling, method validation and analytical quality control, which would be used for update of Korean NSFCT.