• Title/Summary/Keyword: Quality(0) factor

Search Result 2,422, Processing Time 0.036 seconds

Validation of the Thai Version of aWork-related Quality of Life Scale in the Nursing Profession

  • Sirisawasd, Poramate;Chaiear, Naesinee;Johns, Nutjaree Pratheepawanit;Khiewyoo, Jiraporn
    • Safety and Health at Work
    • /
    • v.5 no.2
    • /
    • pp.80-85
    • /
    • 2014
  • Background: Currently available questionnaires for evaluating the quality of worklife do not fully examine every factor related to worklife in all cultures. A tool in Thai is therefore needed for the direct evaluation of the quality of worklife. Our aim was to translate the Work-related Quality of Life Scale-2 (WRQLS-2) into Thai, to assess the validity and reliability of the Thai-translated version, and to examine the tool's accuracy vis-$\grave{a}$-vis nursing in Thailand. Methods: This was a descriptive correlation study. Forward and backward translations were performed to develop a Thai version of the WRQLS. Six nursing experts participated in assessing content validity and 374 registered nurses (RNs) participated in its testing. After a 2-week interval, 67 RNs were retested. Structural validity was examined using principal components analysis. The Cronbach's alpha values were calculated. The respective independent sample t test and intraclass correlation coefficient were used to analyze known-group validity and test-retest reliability. Multistate sampling was used to select 374 RNs from the In- and Outpatient Department of Srinagarind Hospital of the Khon Kaen University (Khon Kaen, Thailand). Results: The content validity index of the scale was 0.97. Principal components analysis resulted in a seven-factor model, which explains 59% of the total variance. The overall Cronbach's alpha value was 0.925, whereas the subscales ranged between 0.67 and 0.82. In the assessment results, the known-group validity was established for the difference between civil servants and university employees [F (7.982, 0.005) and t (3.351; p < 0.05)]. Civil servants apparently had a better quality worklife, compared to university employees. Good test-retest reliability was observed (r = 0.892, p < 0.05). Conclusion: The Thai version of a WRQLS appears to be well validated and practicable for determining the quality of the work-life among nurses in Thailand.

Microwave Dielectric Properties of the $BaO-(Nd,Bi)_2 O_3-TiO_2$$_2$ Ceramic for Mobile Communication Component (이동 통신 부품에 이용되는 $BaO-(Nd,Bi)_2 O_3-TiO_2$계 마이크로파 유전체의 유전 특성)

  • 윤중락;이헌용;김경용;이석원
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.11
    • /
    • pp.947-953
    • /
    • 1998
  • The microwave dielectric properties of X BaO-0.15($Nd_{0.87}Bi_{0.13})_2O_3-(0.85-X)TiO_2 (X=0.14~0.17) and 0.16BaO-0.15(Bi_xNd_{1-x})_2O_3-0.69TiO_2$ (X=0.12~0.15) ceramics sintered at 1320~$1380^{\circ}C$ were investigated. The microwave dielectric properties of X BaO-0.15(Nd_{0.87}Bi_{0.13})_2O_3-(0.85-X)TiO_2$ (X=0.14~0.17) can be controlled effectively by adjusting X content : with increasing X from 0.14 to 0.17 both dielectric constant and temperature coefficient of resonant frequency decreased from 94.6 to 86 and from 22 ppm/^${\circ}C to -7 ppm/^{\circ}C$, respectively, while quality factor increased from 1300 to 1920 (at 4GHz). The microwave dielectric properties of 0.16BaO-0.15(Bi_x/Nd_{1-x2}O_3 -0.69TiO_2$ (X=0.12~0.15) can be controlled effectively by adjusting X content : with increasing X from 0.12 to 0.15 both quality factor and temperature coefficient of resonant frequency decreased from 1920 to 1430 and from 9 ppm/^${\circ}C to -10 ppm/^{\circ}C$, respectively, while dielectric constant increased from 87.5 to 92.6.

  • PDF

Quality Verification for Respiratory Gated Proton Therapy (호흡동조 양성자치료의 Quality Verification)

  • Kim, Eun Sook;Jang, Yo Jong;Park, Ji Yeon;Kang, Dong Yun;Yeom, Doo Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.107-113
    • /
    • 2013
  • Purpose: To verify accuracy of respiratory gated proton therapy by measuring and analyzing proton beam delivered when respiratory gated proton therapy is being performed in our institute. Materials and Methods: The plan data of 3 patients who took respiratory gated proton therapy were used to deliver proton beam from proton therapy system. The manufactured moving phantom was used to apply respiratory gating system to reproduce proton beam which was partially irradiated. The key characteristics of proton beam, range, spreat-out Bragg peak (SOBP) and output factor were measured 5 times and the same categories were measured in the continuous proton beam which was not performed with respiratory gating system. Multi-layer ionization chamber was used to measure range and SOBP, and Scanditronix Wellhofer and farmer chamber was used to measure output factor. Results: The average ranges of 3 patients (A, B, C), who had taken respiratory gated proton therapy or not, were (A) 7.226, 7.230, (B) 12.216, 12.220 and (C) 19.918, 19.920 $g/cm^2$ and average SOBP were (A) 4.950, 4.940, (B) 6.496, 6.512 and (C) 8.486, 8.490 $g/cm^2$. And average output factor were (A) 0.985, 0.984 (B) 1.026, 1.027 and (C) 1.138, 1.136 cGy/MU. The differences of average range were -0.004, -0.004, -0.002 $g/cm^2$, that of SOBP were 0.010, -0.016, -0.004 $g/cm^2$ and that of output factor were 0.001, -0.001, 0.002 cGy/MU. Conclusion: It is observed that the range, SOBP and output factor of proton beam delivered when respiratory gated proton therapy is being performed have the same beam quality with no significant difference compared to the proton beam which was continuously irradiated. Therefore, this study verified the quality of proton beam delivered when respiratory gated proton therapy and confirmed the accuracy of proton therapy using this.

  • PDF

Dielectric and piezoelectric properties of CuO added $(K_{0.5}Na_{0.5})_{0.97}(Nb_{0.96}Sb_{0.04})O_3$ ceramics (CuO첨가에 따른 $(K_{0.5}Na_{0.5})_{0.97}(Nb_{0.96}Sb_{0.04})O_3$세라믹스의 유전 및 압전 특성)

  • Lee, Yu-Hyong;Park, Min-Ho;Noh, Jung-Rae;Yoo, Ju-Hyun;Kim, In-Sung;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.160-161
    • /
    • 2009
  • In this study, in order to develop the lead free piezoelectric ceramics with excellent piezoelectric properties, (Na,K)$NbO_3$ ceramics according to the amount CuO addition were fabricated using a conventional mixed oxide process and their piezoelectric and dielectric characteristics were investigated. At the 0.8mol% CuO added composition, density, electromechanical coupling factor(kp), echanical quality factor(Qm), dielectric constant$(\varepsilon_r$) and piezoelectric constant($d_{33}$) showed the optimum value of $4.459g/cm^3$, 0.469, 540, 410, 69.57pC/N, respectively.

  • PDF

Preparations of $(Zr_{0.08}Sn_{0.2})TiO_4$ Dielectric Powders by Coprecipitation of $(Zr^{4+}, Ti^{4+})-Hydroxides in the Presence of SnO2 Particles (부분 공침법에 의한 $(Zr_{0.08}Sn_{0.2})TiO_4$ 분말합성 및 유전특성)

  • 임경란;장진욱
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.11
    • /
    • pp.1293-1298
    • /
    • 1994
  • (Zr, Sn)TiO4 powders were prepared in 0.05~0.13 ${\mu}{\textrm}{m}$ by coprecipitating (Zr4+, Ti4+)hydroxide on SnO2 particles and followed by calcination at 90$0^{\circ}C$ for 2 h. They sinter to 95% of relative density at 140$0^{\circ}C$ for 2 h. and shows dielectric constant, $\varepsilon$r=37.5 and quality factor, Qxf(GHz)=46,000. With 3 mol% of ZnO it sinters to rel=97.5%, $\varepsilon$r=39 and Qxf(GHz)=40,050 at 135$0^{\circ}C$ for 2 h., but raising sintering temperature to 140$0^{\circ}C$ deteriorates quality factor, relative density and microstructure with developing second phase.

  • PDF

The Effects of Non-Stoichiometry and Sintering Temperature on the Magnetic Properties of Ni-Zn Ferrites (비양론 화학적 조성 및 소결온도가 Ni-Zn Ferrite 의 자기적 성질에 미치는 영향)

  • 박준철;임호빈
    • Journal of the Korean Ceramic Society
    • /
    • v.17 no.2
    • /
    • pp.89-95
    • /
    • 1980
  • The effect of non-stoichimetry and sintering temperature on the magnetic properties of materials in the system $Ni_{0.39}Zn_{0.61}Fe_{2.0+x}O_4$ have been investigated. The value of x used in initial weighing of oxides were varied from -0.04 to -0.12. The value of x, however, appears to be from +0.04 to -0.04 after ferrite powder preparation due to iron pick up during ball mill mixing and grinding. The densities of specimens which were deficientinrion were higher than those with excess ion. Specimens with near stoichiometric composition showed maximum initial permeability an dminimum coercivity whereas high values of quality factor (Q) were observed in iron deficient specimens. The quality factor decreased monotonically with increasing sintering temperature, but the permeability showed maxima with increasing sintering temperature. Thus highest value of figure of merit $\mu$Q was obtained in composition $Ni_{0.39}Zn_{0.61}Fe_{1.98O4}$ sintered at 100$0^{\circ}C$ for 3 hrs. in an air atmosphere.

  • PDF

Effect of CuO and CdO Additions on the Microwave Dielectric Properties of $BiNbO_4$ Ceramics using Mobile Communication (이동 통신용 $BiNbO_4$ 세라믹스의 CuO 및 CdO 첨가량에 따른 고주파 유전 특성)

  • Yun, Jung-Rak;Lee, Heon-Yong;Kim, Gyeong-Yong
    • Korean Journal of Materials Research
    • /
    • v.8 no.11
    • /
    • pp.1043-1047
    • /
    • 1998
  • The effect of CuO and CdO addition on the microwave dielectric properties of $BiNbO_4$, ceramics were investigated. As the content of CdO increased, sintered density and quality factor decreased. With increasing sintering temperature, both the dielectric constant and quality factor increased. In the case of specimen sintered at $960^{\circ}C$ with addition of 0.03 wt% of CuO and CdO, respectively. the microwave dielectric properties obtained were dielectric constant of 41.2, quality factor ($Q{\times}f_0$) of 6,500 (at 5.6GHz), temperature coefficient of resonant frequency of $3ppm^{\circ}C$.

  • PDF

Microwave Dielectric Properties of 0.15BaO-$0.15Sm_2O_3-0.7TiO_2$ Ceramics (0.15BaO-$0.15Sm_2O_3-0.7TiO_2$ 세라믹스의 마이크로파 유전 특성)

  • Lee, Geun-Ill;Park, In-Gil;Lee, Young-Hie;Yoon, Seok-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.185-187
    • /
    • 1993
  • 0.15BaO-$0.15Sm_2O_3-0.7TiO_2$, ceramics were fabricated by mixed-oxide method. Microwave dielectric properties were investigated with sintering temperature and annealing time. In the specimen sintered at 1350[$^{\circ}C$], dielectric constant, quality factor and temperature coefficient of resonant frequency had a good values of 80.19, 2006 (at 4.6851[GHz]), -27.54[ppm/$^{\circ}C$], respectively. Increasing the annealing time, dielectric constant was almost constant and quality factor was increased. Temperature coefficient of resonant frequency was minimum value (-1.28[ppm/$^{\circ}C$]) at 4 [hr] annealed.

  • PDF

Service Quality Dimensions of E-retailing of Islamic Banks and Its Impact on Customer Satisfaction: An Empirical Investigation of Kingdom of Saudi Arabia

  • TABASH, Mosab I.;ALBUGAMI, Moteb A.;SALIM, Mairaj;AKHTAR, Asif
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.3
    • /
    • pp.225-234
    • /
    • 2019
  • The study aims to explore key dimensions of service quality of E-Retailing of Islamic banks in the Kingdom of Saudi Arabia. The convenience sample size consists of 373 respondents who regularly use online Islamic banking facilities in Saudi Arabia was used. For measuring the consumers' perspective, a four-factor E-SERVQUAL scale; namely efficiency, system availability, fulfillment, and privacy was used. Exploratory Factor Analysis and Confirmatory Factor Analysis are used to test the model fitness. Structural equation modelling is utilized to determine the impact of E-service quality dimensions on customers' satisfaction. The results of the study reveal that 1) reliability as a dimension of E-retailing of Islamic banks made a significant impact on customers' overall satisfaction; 2) there is a positive significant relationship between responsiveness and customers' overall satisfaction. One unit increased in responsive leads to 0.763 unit increases in the overall satisfaction of the customer; and 3) ease of use is the most important dimensions of service quality of E-retailing of Islamic banks. One unit increases in Security/ Privacy leads to 0.473 unit increases in overall satisfaction. There is a positive impact of good E-service on customers' satisfaction, but it does not override unsatisfactory performance in other areas.

Piezoelectric and dielectric properties of PMN-PZN ceramics for multilayer piezoelectric transformer with PZN substitution (PZN 치환에 따른 적층 압전변압기용 PMN-PZT 세라믹의 압전 및 유전 특성)

  • Lee, Chang-Bae;Yoo, Ju-Hyun;Paik, Dong-Soo;Im, In-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.59-61
    • /
    • 2005
  • In this paper, in order to develop the low temperature sintering ceramics for multilayer piezoelectric transformer, $Pb[(Mn_{1/3},Nb_{2/3})_{0.07}(Zn_{1/3}Nb_{2/3})_a(Zr_{0.48}Ti_{0.52})_{1-0.07-a}O_3]$ ceramics were manufactured with the variations of PZN from 2 to 14mol% and their dielectric and piezoelectric properties were investigated. Sintering temperature was varied from 910 to $1000^{\circ}C$. At 8mol% PZN substituted specimen sintered at $970^{\circ}C$, electromechanical coupling factor(kp), mechanical quality factor(Qm), dielectric constant and peizoelectric constant($d_{33}$) showed the optimal values of 0.536, 1803, 1551 and 328[pC/N), respectively, for multilayer piezoelectric transformer application.

  • PDF