• Title/Summary/Keyword: Quadrature detection

Search Result 69, Processing Time 0.046 seconds

Design of QPSK Ultrasonic Transceiver For Underwater Communication (수중 통신을 위한 QPSK 초음파 송수신기의 설계)

  • Cho Nai-Hyun;Kim Duk-Yung;Kim Yong-Deuk;Chung Yun-Mo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.51-59
    • /
    • 2006
  • In this paper, we propose an excellent ultrasonic transceiver system based on a QPSK modulation technique for underwater communication. The transmitter sends a still image at the level of 187dB re $1{\mu}Pa/V@1m$ through a power amplifier by driving an ultrasonic sensor. The receiver performs digital conversion at the 100kHz sampling frequency, demodulation and decoding process for the image sent from the transmitter through the underwater communication. We have shown that the processed image at the receiver is almost the same as the orignal one. The maximum detection distance of the system proposed in this paper is approximately 1.17km. To cope with the difficulties of transmission loss, this paper proposes, implements and analyzes important parameters of sensors and circuits used in the system. Most of the underwater communication has focused on the transmission of audio signal, but this paper suggests an efficient underwater communication system for still image transmission.

FPGA Design and Sync-Word Detection of CATV Down-Link Stream Transmission System (CATV 하향 스트림 적용 시스템에서 동기 검출 방안 및 FPGA 설계)

  • Jung, Ji-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.4
    • /
    • pp.286-294
    • /
    • 2011
  • Cable modems typically are implemented by a forward error correction(FEC) scheme. The ITU-T Recommendation J-38 Annex B specifies using 64- and 256- quadrature amplitude modulation (QAM) and extended RS coding scheme. In implementing the cable modem, there are some problems to fabricate and fitting on FPGA chip. First, many clocks are needed in implementing cable modem because of different code rate and different modulation types. To reduce the number of clocks, we use the two memories, which are different clock speed for reading and writing data. Second, this system lost the bit-synchronization and frame-synchronization in decoder, the system recognize that all data is error. This paper solves the problems by using simple 5-stage registers and unique sync-word. Based on solutions for about problems, the cable modem is fabricated on FPGA chip name as Vertex II pro xc2vp30-5 by Xilinx, and we confirmed the effectiveness of the results.

Doppler Radar System for Long Range Detection of Respiration and Heart Rate (원거리에서 측정 가능한 호흡 및 심박 수 측정을 위한 도플러 레이더 시스템)

  • Lee, Jee-Hoon;Kim, Ki-Beom;Park, Seong-Ook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.418-425
    • /
    • 2014
  • This paper presents a Ku-Band Doppler Radar System to measure respiration and heart rate. It was measured by using simultaneous radar and ECG(Electrocardiogram). Arctangent demodulation without dc offset compensation can be applied to transmitted I/Q(In-phase & Quadrature-phase) signal in order to improve the RMSE(Root Mean Square Error) about 50 %. The power leaked to receiving antenna from the transmitting antenna is always generated because of continuously opening the transceiver of CW(Continuous Wave) Doppler radar. As the output power increase, leakage power has an effect on the SNR(Signal-to-Noise Ratio) of the system. Therefore, in this paper, leakage cancellation technique that adds the signal having the opposite phase of the leakage power to the leakage power was implemented in order to minimize the decline of receiver sensitivity. By applying the leakage cancellation techniques described above, it is possible to measure the heart rate and respiration of the human at a distance of up to 35 m. the heart rate of the measured data at a distance of 35 m accords with the heart rate extracted from the ECG data.

Doppler Radar System for Noncontact Bio-signal measurement (비접촉 방식의 생체 신호 측정을 위한 도플러 레이더 시스템)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.357-359
    • /
    • 2009
  • In this paper, the 2.4GHz doppler radar system consisting of the doppler radar module and a baseband module were designed to detect heartbeat and respiration signal without direct skin contact. A bio-radar system emits continuous RF signal of 2.4GHz toward human chest, and then detects the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from quadrature signal of the doppler radar system are applied to the pre-processing circuit, amplification circuit, and the offset circuit of the baseband module. ECG(electrocardiogram) and reference respiration signals are measured simultaneously to evaluate the doppler radar system. As a result, the respiration signal of doppler radar signal is detected to 1m without complex digital signal processing. The sensitivity and calculated from I/Q respiration signal were $98.29{\pm}1.79%$, $97.11{\pm}2.75%$, respectively, and positive predictivity were $98.11{\pm}1.45%$, $92.21{\pm}10.92%$, respectively. The sensitivity and positive predictivity calculated from phase and magnitude of the doppler radar were $95.17{\pm}5.33%$, $94.99{\pm}5.43%$, respectively. In this paper, we confirmed that noncontact real-time heartbeat and respiration detection using the doppler radar system has the possibility and limitation.

  • PDF

Low Complexity Linear Receiver Implementation of SOQPSK-TG Signal Using the Cross-correlated Trellis-Coded Quadrature Modulation(XTCQM) Technique (SOQPSK-TG 신호의 교차상관 격자부호화 직교변조(XTCQM) 기법을 사용한 저복잡도 선형 수신기 구현)

  • Kim, KyunHoi;Eun, Changsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.3
    • /
    • pp.193-201
    • /
    • 2022
  • SOQPSK-TG is a modulated signal for aircraft telemetry with excellent frequency efficiency and power efficiency. In this paper, the phase waveform of the partial response SOQPSK-TG modulation is linearly approximated and modeled as a full response double duobinary SOQPSK (SOQPSK-DD) signal. And using the XTCQM method and the Laurent decomposition method, the SOQPSK-DD signal was approximated as OQPSK having linear pulse waveforms, and the results of the two methods were proved to be the same. In addition, it was confirmed that the Laurent decomposition waveform of the SOQPSK-DD signal approximates the Laurent decomposition waveform of the original SOQPSK-TG signal. And it was shown that the decision feedback IQ-detector, which applied the Laurent decomposition waveform of SOQPSK-DD to the detection filter, exhibits almost the same performance even with a simpler waveform than before.

A PN-code Acquisition method Using Array Antenna Systems for CDMA2000 1x (CDMA2000 1x용 배열 안테나 시스템에서 PN 동기 획득 방법)

  • Jo, Hee-Nam;Yun, Yu-Suk;Choi, Seung-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.8 s.338
    • /
    • pp.33-40
    • /
    • 2005
  • This paper presents a structure of the searcher using a diversity in array antenna systems operating in the cdma2000 1x signal environments. The new technique exploits the fact that the In-phase and quadrature components of interferers can respectively be viewed as an independent gaussian noise at each antnna element in most practical cdma signal environments. The proposed PN acquisition scheme is a singles-dwell PN acquisition system consisting of two stages, that is, the searching stage and the verification stage. The searching stage independently correlates the receiver multiple signals with PN generator of each antenna element for obtaining the synchronous energy at the entire region. Then, the searching results of each antenna element are non-coherently combinind. The verification stage compares the searching energy with the optimal threshold, which is predesigned in the lock detector, and decides whether the acquisition is successful or fail. In this paper, we analyzed the effect of tile diversity order to determine the mean acquisition time. In general, it is known that the mean acquisition time significantly decrease as the number of antenna elements increases. But, as the diversity order goes up, the enhancement of the performance is saturated. Therefore, to decrease the mean acquisition time of the searcher, we must design the optimal array antenna systems by considering the operating SNR range of the receiver, the probability of detection $P_D$ and that of false alarm $P_{FA}$ . The Performance of the proposed PN acquisition scheme is analyzed in frequency selective Rayleigh fading channels. In this paper, the effect of the number of antenna elements on PN acquisition scheme is shown according to the probability of detection $P_D$ and that of false alarm $P_{FA}$.

Design of a 16-QAM Carrier Recovery Loop for Inmarsat M4 System Receiver (Inmarsat M4 시스템 수신기를 위한 16-QAM Carrier Recovery Loop 설계)

  • Jang, Kyung-Doc;Han, Jung-Su;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.4A
    • /
    • pp.440-449
    • /
    • 2008
  • In this paper, we propose a 16-QAM carrier recovery loop which is suitable for the implementation of Inmarsat M4 system receiver. Because the frequency offset of ${\pm}924\;Hz$ on signal bandwidth 33.6 kHz is recommended in Inmarsat M4 system specification, carrier recovery loop having stable operation in the channel environment with large relative frequency offset is required. the carrier recovery loop which adopts only PLL can't be stable in relatively large frequency offset environment. Therefore, we propose a carrier recovery loop which has stable operation in large relative frequency offset environment for Inmarsat M4 system. The proposed carrier recovery loop employed differential filter-based noncoherent UW detector which is robust to frequency offset, CP-AFC for initial frequency offset acquisition using UW signal, and 16-QAM DD-PLL for phase tracking using data signal to overcome large relative frequency offset and achieve stable carrier recovery performance. Simulation results show that the proposed carrier recovery loop has stable operation and satisfactory performance in large relative frequency offset environment for Inmarsat M4 system.

Design of Carrier Recovery Circuit for High-Order QAM - Part I : Design and Analysis of Phase Detector with Large Frequency Acquisition Range (High-Order QAM에 적합한 반송파 동기회로 설계 - I부. 넓은 주파수 포착범위를 가지는 위상검출기 설계 및 분석)

  • Kim, Ki-Yun;Cho, Byung-Hak;Choi, Hyung-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.4
    • /
    • pp.11-17
    • /
    • 2001
  • In this paper, we propose a polarity decision carrier recovery algorithm for high order QAM(Quadrature Amplitude Modulation), which has robust and large frequency acquisition performance in the high order QAM modem. The proposed polarity decision PD(Phase Detector) output and its variance characteristic are mathematically derived and the simulation results are compared with conventional DD(Decision-Directed) method. While the conventional DD algorithm has linear range of $3.5^{\circ}{\sim}3.5^{\circ}$, the proposed polarity decision PD algorithm has linear range as large as $-36^{\circ}{\sim}36^{\circ}$ at ${\gamma}-17.9$. The conventional DD algorithm can only acquire offsets less than ${\pm}10\;KHz$ in the case of the 256 QAM while an analog front-end circuit generally can reduce the carrier-frequency offset down to only ${\pm}100\;KHz$. Thus, in this case additional AFC or phase detection circuit for carrier recovery is required. But by adopting the proposed polarity decision algorithm, we can find the system can acquire up to ${\pm}300\;KHz$at SNR = 30dB without aided circuit.

  • PDF

Ex Vivo MR Diffusion Coefficient Measurement of Human Gastric Tissue (인체의 위 조직 시료에서 자기공명영상장치를 이용한 확산계수 측정에 대한 기초 연구)

  • Mun Chi-Woong;Choi, Ki-Sueng;Nana Roger;Hu, Xiaoping P.;Yang, Young-Il;Chang Hee-Kyung;Eun, Choong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.203-209
    • /
    • 2006
  • The aim of this study is to investigate the feasibility of ex vivo MR diffusion tensor imaging technique in order to observe the diffusion-contrast characteristics of human gastric tissues. On normal and pathologic gastric tissues, which have been fixed in a polycarbonate plastic tube filled with 10% formalin solution, laboratory made 3D diffusion tensor Turbo FLASH pulse sequence was used to obtain high resolution MR images with voxel size of $0.5{\times}0.5{\times}0.5mm^3\;using\;64{\times}32{\times}32mm^3$ field of view in conjunction with an acquisition matrix of $128{\times}64{\times}64$. Diffusion weighted- gradient pulses were employed with b values of 0 and $600s/mm^2$ in 6 orientations. The sequence was implemented on a clinical 3.0-T MRI scanner(Siemens, Erlangen, Germany) with a home-made quadrature-typed birdcage Tx/Rx rf coil for small specimen. Diffusion tensor values in each pixel were calculated using linear algebra and singular value decomposition(SVD) algorithm. Apparent diffusion coefficient(ADC) and fractional anisotropy(FA) map were also obtained from diffusion tensor data to compare pixel intensities between normal and abnormal gastric tissues. The processing software was developed by authors using Visual C++(Microsoft, WA, U.S.A.) and mathematical/statistical library of GNUwin32(Free Software Foundation). This study shows that 3D diffusion tensor Turbo FLASH sequence is useful to resolve fine micro-structures of gastric tissue and both ADC and FA values in normal gastric tissue are higher than those in abnormal tissue. Authors expect that this study also represents another possibility of gastric carcinoma detection by visualizing diffusion characteristics of proton spins in the gastric tissues.