• 제목/요약/키워드: Qmax

검색결과 50건 처리시간 0.025초

삼각사와 원형사로 제직된 직물의 태, 열적성질 및 광학적 성질의 비교 (Comparison of hand, thermal and optical properties of woven fabrics made of triangular and circular shaped filaments)

  • 심현주;홍경아
    • 감성과학
    • /
    • 제5권3호
    • /
    • pp.47-52
    • /
    • 2002
  • 직물의 태는 손으로 만져 보았을 때 느껴지는 감촉, 육안으로 느껴지는 감각, 그리고 직물의 물리적 역학적 성질 등이 함께 어울어져 이루어지는 것이다. 따라서 본 연구에서는 폴리에스테르 원형사와 삼각사로 제직된 직물의 태와 온/냉감 및 광택도를 측정하였다. 삼각단면사로 제직된 직물이 원형단면사로 제직된 직물보다 더 좋은 태를 보였으며 열전달계수가 크게 나타나 냉감을 느낄 수 있었으며 높은 반사율을 보였다.

  • PDF

기중방전의 방전원별 특성분석 및 패턴분류 (Properties and Classification of Patterns of Air Discharges)

  • 박영국;이광우;장동욱;강성화;정광호;김완수;이용희;임기조
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석 (Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler)

  • 오봉근;김현일;강성화;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제20권10호
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

이온교환법에 의한 탈질소 공정개발의 기초연구(III) - 회분식 반응기에서의 반응속도론- (Basic Study for Development of Denitrogenation Process by Ion Exchange(III) - A kinetic study in the batch reactor -)

  • 채용곤;이동환;김승일;윤태경;홍성수;이민규
    • 한국환경과학회지
    • /
    • 제9권2호
    • /
    • pp.165-171
    • /
    • 2000
  • A kinetic study for anion exchange was performed for commercially available Cl- type anion exchange resin in use to remove nitrate in water. The obtained results from the batch reactor were applied to the Langmuir and Freundlich models. The constants for Lagmuir model were qmax =29.82 and b=0.202, and for Freundlich model were K=5.509 and n=1.772. Langmuir model showed betterfit than Frendlich model for the experimental results. Ion exchange reaction rate was also calculated and the the approximate first-order reaction, rate constant k1 was 0.16 L/mg.hr. Effective diffusion coefficient was obtained in the range from $9.67$\times$10^{-8} cm^2/sec$ for initial concentration change, and from $6.09$\times$10^{-7} to 3.98$\times$10^{-6} cm^2/sec$ for reaction temperature change. Activation energy during the diffusion was calculated as 26 kcal/mol.

  • PDF

태권도복 소재의 성능 및 착용감의 개선을 위한 연구 (A Study on the Improvement in Performances and Wearing Sensation of Textiles for Taekwondo Wears)

  • 전영민;박정희;최정화
    • 한국의류학회지
    • /
    • 제27권1호
    • /
    • pp.134-142
    • /
    • 2003
  • Performances of Taekwondo fabrics were evaluated in respect of fiber component. yarn count, weave structure and wearing comfort. As a beginning step, we investigated the present situation of Taekwondo wears by questionnaire from pro and amateur Taekwondo players. Samples employed in this study were cotton/nylon blend fabric that was newly woven for this study as well as fabrics of current Taekwondo wears for sale in the market. Their fundamental properties measured were such as air permeability, water vapor transport. wickability, absorption rate, Qmax values, thermal conductivity, durability, hand value, and etc. In addition, subjective wearing sensations were evaluated using Taekwondo wears made of those fabrics. From the results of the objective measurement and the subjective wearing test, we estimated the total fitness of fabrics as a Taekwondo wear. From the questionnaire we could see that pro players and amateurs wanted highly absorbing, quick drying, and soft-tough and complained abrasive surfaces and static elasticity of current fabrics. In view of the results so far achieved, nylon blended fabrics newly woven in this study, showed better comfort-related properties from both of the objective and subjective tests. It was also represented that finer yams enhanced water absorption and touch, and fabrics with rough surface such as honeycomb weave was superior in wearing comfort as well as aesthetic appearance.

복합성 요실금과 복압성 요실금의 특성: 하부요로증상과 요역동학 검사결과의 관계 (Characteristics of Mixed Urinary Incontinence and Stress Urinary Incontinence: Relationship between Lower Urinary Tract Symptoms and Urodynamic Parameters)

  • 이지연;송미순
    • Journal of Korean Biological Nursing Science
    • /
    • 제19권2호
    • /
    • pp.60-68
    • /
    • 2017
  • Purpose: The purpose of this study was to analyze the relationship between lower urinary tract symptoms and urodynamic parameters to investigate the characteristics of mixed urinary incontinence (MUI) and stress urinary incontinence (SUI). Methods: The subjects were 318 women with MUI and 128 women with SUI. Data were collected retrospectively from electronic medical records including Bristol Female Lower Urinary Tract Symptoms-Scored Form (BFLUTS-SF), Incontinence Quality of Life Instrument (I-QOL), voiding diaries, and urodynamic parameters. Results: Compared with the SUI group, the MUI group was older and showed lower I-QOL and more severe urinary tract symptoms. The MUI group had more urinary frequency, more nocturia, and a higher urgency score than the SUI group. In the correlation analysis, the greatest difference between the two groups was that urgency was associated with Qmax, maximal cystometric capacity, and detrusor overactivity only in the MUI group (r = -.175, p= .004; r = -.281, p< .001; r= .232, p< .001, respectively). Conclusion: As a result of this study, we propose that a customized management program that emphasizes the control of urgency for the MUI group, and one that effectively strengthens the weak pelvic floor for the SUI group.

활성슬러지 공정에 의한 Acetaldehyde 제조 공장 폐수의 처리 (Treatment of Wastewater from Acetaldehyde Plant by Activated Sludge Process)

  • 서승교;김정호;김영호
    • 한국환경과학회지
    • /
    • 제6권3호
    • /
    • pp.259-265
    • /
    • 1997
  • This study was conducted to Investigate the treatment of wastewater from acetaldehyde manufacturing plant by activated sludge process with Micrococcus roseus AW-6, Micrococcus roseus AW-22, Microbacterium lacticum AW-38 and Mlcrobacterium nae- vaniformans AW-41. The $COD_{Mn}$ and $BOD_5$ of the wastewater were 5, 260mg/L and 6, 452mg/L, respectively. pH was 1.85. The main organic component in the wastewater was acetic acrid which was contained 67, 600mg/L. Optimum dilution time for activated sludge process was shown 10 times. The specific substrate removal rate(BL) was 1.95day-1 and the nonbiodegradable matters(Sn) were 23.2mg/L. Saturation constant (Ks) and mainmum specific growth rate(qmax) were 1, 640mg/L and 2.33day-1, respectively. Sludge yield coefficient(Y) and endogenous respiration coefficient(kd) were 0.28mg MLVSS/mgCOD and 0.02day-1, respectively. $COD_{cr}$ removal efficiency was 91% for 1.95day of hydraulic retention time.

  • PDF

기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류 (Properties and classification of air discharge by Kohonen network)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

양모 복지의 초기열류속최대치($q_{max}$)에 관한 연구(II) -직물 표면 형태 인자와의 상관성을 중심으로 - (A Study on the Initial Maximum Value of Heat Flux, $q_{max}$ of Wool Fabrics (Part II) - The correlation between $q_{max}$ and chracteristic values -)

  • 최석철;정진순;천태일
    • 한국의류학회지
    • /
    • 제15권4호
    • /
    • pp.373-380
    • /
    • 1991
  • In the previous paper, we already discussed about the factor effected upon the initial maximum value of heat flux ($q_{max}$). Thermal conductivity, thermal transmittance and surface air cavity of wool fabrics were examind and their correlation to the $q_{max}$ was also studied In this study, the other factor was examined which had on effect upon the qmaf of an objective measure of warm/cool feeling. It was studied that the qmax correlated to the surface sturucture parameters (compression, friction, smoothness, roughness, thickness and weight). It was concerned to the degree of warm/cool feeling when we touched hand on fabrics. We selected twenty sorts of pure wool woven fabrics for men's fall-winter cloth (all Wool). The conclusions are as follow; 1. There was a good correlation between the $q_{max}$ and the compression property. 2. The surface structure parameters, smoothness and roughness, made various effects on the $q_{max}$, when the samples touched on a thin copper plate. So, there was not a certain correla-tion to the $q_{max}$.

  • PDF

프러시안 블루 고정화에 따른 133Cs의 흡착거동 모델링 (A Study on the Adsorption Kinetics of 133Cs by Different Impregnations of Prussian Blue)

  • 최상선;이우정;윤경재;조연지;이준혁;이순홍
    • 한국안전학회지
    • /
    • 제36권1호
    • /
    • pp.80-85
    • /
    • 2021
  • Radionuclides, particularly radioactive cesium (Cs), are a concern of human health in some nuclear power accidents. It could lead to a high level of intracellular accumulation due to its high radioactivity and long half-life. Therefore, it is imperative to develop a method to remove Cs from wastewater. Herein, we synthesized activated carbon fibers (ACFs) doped with Prussian blue (PB) via in situ methods. We classified samples by their preparation method as either physical (PB-ACF-A) or physicochemical (PB-ACF-B) syntheses for comparison. The PB-ACF-B sample showed a significant surface loss compared to PB-ACF-A but a better 133Cs adsorption capacity. All samples fit well to Langmuir isotherms and the values of qmax were directly correlated to the amount of PB on the surface of the ACFs. Adsorption characteristics were further confirmed by the calculated free energy, enthalpy, and entropy.